1000 resultados para Nurse–patient ratio


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the first part of direct numerical simulation (DNS) of double-diffusive convection in a slim rectangular enclosure with horizontal temperature and concentration gradients. We consider the case with the thermal Rayleigh number of 10^5, the Pradtle number of 1, the Lewis number of 2, the buoyancy ratio of composition to temperature being in the range of [0,1], and height-to-width aspect ration of 4. A new 7th order upwind compact scheme was developed for approximation of convective terms, and a three-stage third-order Runge-Kutta method was employed for time advancement. Our DNS suggests that with the buoyancy ratio increasing form 0 to 1, the flow of transition is a complex series changing fromthe steady to periodic, chaotic, periodic, quasi-periodic, and finally back to periodic. There are two types of periodic flow, one is simple periodic flow with single fundamental frequency (FF), and another is complex periodic flow with multiple FFs. This process is illustrated by using time-velocity histories, Fourier frequency spectrum analysis and the phase-space rajectories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sex-ratio of Clarias gariepinus in Opa Reservoir was 2:1 (male/female). The fecundity of C. gariepinus in Opa reservoir ranged between 1,567 and 650,625 egg. The fish species had extended spawning period which probably spreads the risk of predation on the eggs. The population of the fish species could be improved by stocking with the female breeders

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The motion of a single Brownian particle of arbitrary size through a dilute colloidal dispersion of neutrally buoyant bath spheres of another characteristic size in a Newtonian solvent is examined in two contexts. First, the particle in question, the probe particle, is subject to a constant applied external force drawing it through the suspension as a simple model for active and nonlinear microrheology. The strength of the applied external force, normalized by the restoring forces of Brownian motion, is the Péclet number, Pe. This dimensionless quantity describes how strongly the probe is upsetting the equilibrium distribution of the bath particles. The mean motion and fluctuations in the probe position are related to interpreted quantities of an effective viscosity of the suspension. These interpreted quantities are calculated to first order in the volume fraction of bath particles and are intimately tied to the spatial distribution, or microstructure, of bath particles relative to the probe. For weak Pe, the disturbance to the equilibrium microstructure is dipolar in nature, with accumulation and depletion regions on the front and rear faces of the probe, respectively. With increasing applied force, the accumulation region compresses to form a thin boundary layer whose thickness scales with the inverse of Pe. The depletion region lengthens to form a trailing wake. The magnitude of the microstructural disturbance is found to grow with increasing bath particle size -- small bath particles in the solvent resemble a continuum with effective microviscosity given by Einstein's viscosity correction for a dilute dispersion of spheres. Large bath particles readily advect toward the minimum approach distance possible between the probe and bath particle, and the probe and bath particle pair rotating as a doublet is the primary mechanism by which the probe particle is able to move past; this is a process that slows the motion of the probe by a factor of the size ratio. The intrinsic microviscosity is found to force thin at low Péclet number due to decreasing contributions from Brownian motion, and force thicken at high Péclet number due to the increasing influence of the configuration-averaged reduction in the probe's hydrodynamic self mobility. Nonmonotonicity at finite sizes is evident in the limiting high-Pe intrinsic microviscosity plateau as a function of bath-to-probe particle size ratio. The intrinsic microviscosity is found to grow with the size ratio for very small probes even at large-but-finite Péclet numbers. However, even a small repulsive interparticle potential, that excludes lubrication interactions, can reduce this intrinsic microviscosity back to an order one quantity. The results of this active microrheology study are compared to previous theoretical studies of falling-ball and towed-ball rheometry and sedimentation and diffusion in polydisperse suspensions, and the singular limit of full hydrodynamic interactions is noted.

Second, the probe particle in question is no longer subject to a constant applied external force. Rather, the particle is considered to be a catalytically-active motor, consuming the bath reactant particles on its reactive face while passively colliding with reactant particles on its inert face. By creating an asymmetric distribution of reactant about its surface, the motor is able to diffusiophoretically propel itself with some mean velocity. The effects of finite size of the solute are examined on the leading order diffusive microstructure of reactant about the motor. Brownian and interparticle contributions to the motor velocity are computed for several interparticle interaction potential lengths and finite reactant-to-motor particle size ratios, with the dimensionless motor velocity increasing with decreasing motor size. A discussion on Brownian rotation frames the context in which these results could be applicable, and future directions are proposed which properly incorporate reactant advection at high motor velocities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a necessary condition for the validity of the present value model, the price-dividend ratio must be stationary. However, significant market episodes seem to provide evidence of prices significantly drifting apart from dividends while other episodes show prices anchoring back to dividends. This paper investigates the stationarity of this ratio in the context of a Markov- switching model à la Hamilton (1989) where an asymmetric speed of adjustment towards a unique attractor is introduced. A three-regime model displays the best regime identification and reveals that the first part of the 90’s boom (1985-1995) and the post-war period are characterized by a stationary state featuring a slow reverting process to a relatively high attractor. Interestingly, the latter part of the 90’s boom (1996-2000), characterized by a growing price-dividend ratio, is entirely attributed to a stationary regime featuring a highly reverting process to the attractor. Finally, the post-Lehman Brothers episode of the subprime crisis can be classified into a temporary nonstationary regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under coronal conditions, the steady state rate-equations are used to calculate the inter-stage line ratios between Li-like Is(2)2p(P-2(3/2))-> 1s(2)2s -> ((2) S-1/2) and He-like 1s2p (P-1(1))-> 1s(2) (S-1(0)) transitions for Ti in the electronic temperature ranges from 0.1 keV to 20 keV. The results show that the. temperature sensitivities are higher at the electronic temperature less than 5000 eV and the temperature sensitivities will decrease with the increase of electronic temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundamental studies of magnetic alignment of highly anisotropic mesostructures can enable the clean-room-free fabrication of flexible, array-based solar and electronic devices, in which preferential orientation of nano- or microwire-type objects is desired. In this study, ensembles of 100 micron long Si microwires with ferromagnetic Ni and Co coatings are oriented vertically in the presence of magnetic fields. The degree of vertical alignment and threshold field strength depend on geometric factors, such as microwire length and ferromagnetic coating thickness, as well as interfacial interactions, which are modulated by varying solvent and substrate surface chemistry. Microwire ensembles with vertical alignment over 97% within 10 degrees of normal, as measured by X-ray diffraction, are achieved over square cm scale areas and set into flexible polymer films. A force balance model has been developed as a predictive tool for magnetic alignment, incorporating magnetic torque and empirically derived surface adhesion parameters. As supported by these calculations, microwires are shown to detach from the surface and align vertically in the presence of magnetic fields on the order of 100 gauss. Microwires aligned in this manner are set into a polydimethylsiloxane film where they retain their vertical alignment after the field has been removed and can subsequently be used as a flexible solar absorber layer. Finally, these microwires arrays can be protected for use in electrochemical cells by the conformal deposition of a graphene layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilization of the heavy isotope of nitrogen as a tracer has found numerous applications in soil biology. It allows better definition of different stages of the nitrogen cycle, in particular the immobilization-mineralization cycle. In this work, the authors report the results of calculations of natural isotope ratios of nitrogen in samples of water, soil and vegetation prevailing in Dombes and discuss the possibilities of errors and coefficients of fractionation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a united theory that describes the two-center recording system by taking scattering noise into account. The temporal evolution of the signal-to-noise ratio in doubly doped photorefractive crystals is described based on jointly solving material equations and coupled-wave equations with the fourth-order Runge-Kutta method. Roles of microcosmic optical parameters of dopants on the signal-to-noise ratio are discussed in detail. The theoretical results can confirm and predict experimental results. (c) 2005 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When noises considerations are made, nonredundant arrays (NRAs) are endowed with many advantages which other arrays e.g., uniformly redundant arrays (URAs) do not possess in applications of coded aperture imaging. However, lower aperture opening ratio limits the applications of NRA in practice. In this paper, we present a computer searching method based on a global optimization algorithm named DIRECT to design NRAs. Compared with the existing NRAs e.g., Golay's NRAs, which are well known and widely used in various applications, NRAs found by our method have higher aperture opening ratio and auto correlation compression ratio. These advantages make our aperture arrays be very useful for practical applications especially for which of aperture size are limited. Here, we also present some aperture arrays we found. These aperture arrays have an interesting property that they belong to both NRA and URA. (C) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A deep binary silicon grating as high-extinction-ratio reflective polarizing beam splitter (PBS) at the wavelength of 1550 nm is presented. The design is based on the phenomenon of total internal reflection (TIR) by using the rigorous coupled wave analysis (RCWA). The extinction ratio of the rectangular PBS grating can reach 2.5×105 with the optimum grating period of 397 nm and groove depth of 1.092 μm. The effciencies of TM-polarized wave in the 0th order and TE-polarized wave in the −1st order can both reach unity at the Littrow angle. Holographic recording technology and inductively coupled plasma (ICP) etching could be used to fabricate the silicon PBS grating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EU]Lan honen helburu nagusia,Gipuzkoako udalen finantza kaudimena aztertzeaz gain, beraien arteko konparaketa bat egin ahal izatea zen. Beste modu batera esanda,egoera hobeagoan dauden udalak nortzuk diren identifikatu ahal izatea. Hasi aurretik bagenekien, ordea, udal baten finantza kaudimena ez dagoela faktore bat edo biren arabera soilik, eta gauza asko subjektiboak direla ere bai. Gainera, eragina duten baldintza guztiak kontuan hartzea ere zaila da. Kasu honetan, 9-10 adierazle aukeratu dira, ondoren udal bakoitzak besteekin konparatuz adierazle horretan lortutako zenbatekoa 1etik 10erako puntuazio batekin baloratu da, eta azkenik, udaletxe guztien ranking bat osatu da. Ondorengo lerroetan ikus daiteke ranking honen testuingurua,erabilitako metodologia eta egindako kalkuluen ondorio nagusiak ere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of the geographic and bathymetric distribution of Penaeus duorarum and, particularly P. d. notialis off Côte d'Ivoire and in its whole distribution area leads to the definition of the adult ecological requirements (temperature, salinity, grain size and sediment composition, organic matter) and the importance of the thermocline in the bathmetric distribution. The population structure study shows: (1) variations of size with depth, (2) variations of sex ratio, with size, depth and seasons.