926 resultados para Newborn Infant
Resumo:
OBJECTIVE:: Report of a 16q24.1 deletion in a premature newborn, demonstrating the usefulness of array-based comparative genomic hybridization in persistent pulmonary hypertension of the newborn and multiple congenital malformations. DESIGN:: Descriptive case report. SETTING:: Genetic department and neonatal intensive care unit of a tertiary care children's hospital. INTERVENTIONS:: None. PATIENT:: We report the case of a preterm male infant, born at 26 wks of gestation. A cardiac malformation and bilateral hydronephrosis were diagnosed at 19 wks of gestation. Karyotype analysis was normal, and a 22q11.2 microdeletion was excluded by fluorescence in situ hybridization analysis. A cesarean section was performed due to fetal distress. The patient developed persistent pulmonary hypertension unresponsive to mechanical ventilation and nitric oxide treatment and expired at 16 hrs of life. MEASUREMENTS AND MAIN RESULTS:: An autopsy revealed partial atrioventricular canal malformation and showed bilateral dilation of the renal pelvocaliceal system with bilateral ureteral stenosis and annular pancreas. Array-based comparative genomic hybridization analysis (Agilent oligoNT 44K, Agilent Technologies, Santa Clara, CA) showed an interstitial microdeletion encompassing the forkhead box gene cluster in 16q24.1. Review of the pulmonary microscopic examination showed the characteristic features of alveolar capillary dysplasia with misalignment of pulmonary veins. Some features were less prominent due to the gestational age. CONCLUSIONS:: Our review of the literature shows that alveolar capillary dysplasia with misalignment of pulmonary veins is rare but probably underreported. Prematurity is not a usual presentation, and histologic features are difficult to interpret. In our case, array-based comparative genomic hybridization revealed a 16q24.1 deletion, leading to the final diagnosis of alveolar capillary dysplasia with misalignment of pulmonary veins. It emphasizes the usefulness of array-based comparative genomic hybridization analysis as a diagnostic tool with implications for both prognosis and management decisions in newborns with refractory persistent pulmonary hypertension and multiple congenital malformations.
Resumo:
OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.
Resumo:
We evaluated a new combined sensor for monitoring transcutaneous carbon dioxide tension (PtcCO2) and oxygen tension (PtcO2) in 20 critically ill newborn infants. Arterial oxygen tension (PaO2) ranged from 16 to 126 torr and arterial carbon dioxide tension (PaCO2) from 14 to 72 torr. Linear correlation analysis (100 paired values) of PtcO2 versus PaO2 showed an r value of 0.75 with a regression equation of PtcO2 = 8.59 + 0.905 (PaO2), while PtcCO2 versus PaCO2 revealed a correlation coefficient of r = 0.89 with an equation of PtcCO2 = 2.53 + 1.06 (PaCO2). The bias between PaO2 and PtcO2 was -2.8 with a precision of +/- 16.0 torr (range, -87 to +48 torr). The bias between PaCO2 and PtcCO2 was -5.1 with a precision of +/- 7.3 torr (range, -34 to +8 torr). The transcutaneous sensor detected 83% of hypoxia (PaO2 less than 45 torr), 75% of hyperoxia (PaO2 greater than 90 torr), 45% of hypocapnia (PaCO2 less than 35 torr), and 96% of hypercapnia (PaCO2 greater than 45 torr). We conclude that the reliability of the combined transcutaneous PO2 and PCO2 monitor in sick neonates is good for detecting hypercapnia, fair for hypoxia and hyperoxia, but poor for hypocapnia. It is an improvement in that it spares available skin surface and requires less handling, but it appears to be slightly less accurate than the single electrodes.
Resumo:
This study examined the interrelatedness of mother-infant and father-infant relationships as they develop over the first 4 months postpartum as well as the dynamics used by the couple to balance these relationships. First-time mother-father couples (n = 18) were interviewed separately at 1, 6, and 16 weeks postpartum using the Parent-Infant Relationship Interview. The data were analyzed using in-depth qualitative strategies. The parents' core themes of their early family relationships ranged from an undifferentiated unit at 1 week, to being a highly disorganized unit at 6 weeks, to a more integrated unit at 16 weeks. These results suggest that one should be thinking of early family relationships and parenting in terms of "messy processes" out of which new ways of being together are created. This disorganization plays a fundamental role in the establishment of early family relationships and warrants further empirical and clinical attention.
Resumo:
BACKGROUND: Newborn screening (NBS) for Cystic Fibrosis (CF) has been introduced in many countries, but there is no ideal protocol suitable for all countries. This retrospective study was conducted to evaluate whether the planned two step CF NBS with immunoreactive trypsinogen (IRT) and 7 CFTR mutations would have detected all clinically diagnosed children with CF in Switzerland. METHODS: IRT was measured using AutoDELFIA Neonatal IRT-Kit in stored NBS cards. RESULTS: Between 2006 and 2009, 66 children with CF were reported, 4 of which were excluded for various reasons (born in another country, NBS at 6 months, no informed consent). 98% (61/62) had significantly higher IRT compared to matched control group. There was one false negative IRT result in an asymptomatic child with atypical CF (normal pancreatic function and sweat test). CONCLUSIONS: All children but one with atypical CF would have been detected with the planned two step protocol.
Resumo:
In our area, varicella is a frequent and essentially benign childhood disease. In contrast, the disease course is likely to be more severe or complicated in the adult, particularly so in the pregnant woman. There is a definite risk of congenital varicella syndrome when the chickenpox occurs during the first 20 weeks of pregnancy. This syndrome predominantly affects the skin, the subcutaneous tissue, muscles and bones, as well as the central nervous system, and can bring about major functional sequellae. In case of chickenpox occurring at the very end of pregnancy, transplacental transfer of the virus may result in a perinatal varicella disease. We propose a approach of each of these different situations.
Resumo:
A female newborn is reported with dextrocardia and a partial trisomy 20q, derived from a t(2;20) paternal translocation. The most discriminating findings of the condition include brachycephaly, bulging forehead, deep set eyes, short nose, large ears, dimpled chin, short neck and a heart defect. Previously reported patients with this rare chromosomal anomaly are reviewed.
Resumo:
Rotaviruses are the major cause of severe diarrhea in infants and young children worldwide. Due to their restricted site of replication, i.e., mature enterocytes, local intestinal antibodies have been proposed to play a major role in protective immunity. Whether secretory immunoglobulin A (IgA) antibodies alone can provide protection against rotavirus diarrhea has not been fully established. To address this question, a library of IgA monoclonal antibodies (MAbs) previously developed against different proteins of rhesus rotavirus was used. A murine hybridoma "backpack tumor" model was established to examine if a single MAb secreted onto mucosal surfaces via the normal epithelial transport pathway was capable of protecting mice against diarrhea upon oral challenge with rotavirus. Of several IgA and IgG MAbs directed against VP8 and VP6 of rotavirus, only IgA VP8 MAbs (four of four) were found to protect newborn mice from diarrhea. An IgG MAb recognizing the same epitope as one of the IgA MAbs tested failed to protect mice from diarrhea. We also investigated if antibodies could be transcytosed in a biologically active form from the basolateral domain to the apical domain through filter-grown Madin-Darby canine kidney (MDCK) cells expressing the polymeric immunoglobulin receptor. Only IgA antibodies with VP8 specificity (four of four) neutralized apically administered virus. The results support the hypothesis that secretory IgA antibodies play a major role in preventing rotavirus diarrhea. Furthermore, the results show that the in vivo and in vitro methods described are useful tools for exploring the mechanisms of viral mucosal immunity.
Resumo:
It has been suggested that determination of the neutrophil elastase alpha1-proteinase inhibitor complex (E-alpha1PI) improves the diagnosis of bacterial infection in newborns. We evaluated the use of E-alpha1PI measurements in 143 newborns, consecutively admitted to a tertiary intensive care unit, employing a new random access assay and a sampling procedure that minimises post-collection artefacts. The 95% range for noninfected newborns was 20-110 microg/l up to the 5th day of life and 20-85 microg/l thereafter. The sensitivity as to the diagnosis of culture-proven bloodstream infection was 80% for E-alpha1PI, 86% for the immature to total neutrophil ratio, 64% for C-reactive protein and 37% for the total white blood cell count. The corresponding specificity amounted to 97%, 85%, 85% and 86%, respectively. E-alpha1PI increases preceded elevations of C-reactive protein by 18 h. Like C-reactive protein, E-alpha1PI levels did not distinguish between bloodstream infection and non-bacterial inflammatory responses. Results of E-alpha1PI became available within 1 h of collection and usually 2-3 h before manual leucocyte counts. CONCLUSION: Determination of neutrophil elastase alpha1-proteinase inhibitor levels yields diagnostic advantages comparable to those of manual differential counts but provide faster turnaround times.
Resumo:
To determine the separate and interactive effects of fetal inflammation and neonatal hyperoxia on the developing lung, we hypothesized that: 1) antenatal endotoxin (ETX) causes sustained abnormalities of infant lung structure; and 2) postnatal hyperoxia augments the adverse effects of antenatal ETX on infant lung growth. Escherichia coli ETX or saline (SA) was injected into amniotic sacs in pregnant Sprague-Dawley rats at 20 days of gestation. Pups were delivered 2 days later and raised in room air (RA) or moderate hyperoxia (O₂, 80% O₂ at Denver's altitude, ∼65% O₂ at sea level) from birth through 14 days of age. Heart and lung tissues were harvested for measurements. Intra-amniotic ETX caused right ventricular hypertrophy (RVH) and decreased lung vascular endothelial growth factor (VEGF) and VEGF receptor-2 (VEGFR-2) protein contents at birth. In ETX-exposed rats (ETX-RA), alveolarization and vessel density were decreased, pulmonary vascular wall thickness percentage was increased, and RVH was persistent throughout the study period compared with controls (SA-RA). After antenatal ETX, moderate hyperoxia increased lung VEGF and VEGFR-2 protein contents in ETX-O₂ rats and improved their alveolar and vascular structure and RVH compared with ETX-RA rats. In contrast, severe hyperoxia (≥95% O₂ at Denver's altitude) further reduced lung vessel density after intra-amniotic ETX exposure. We conclude that intra-amniotic ETX induces fetal pulmonary hypertension and causes persistent abnormalities of lung structure with sustained pulmonary hypertension in infant rats. Moreover, moderate postnatal hyperoxia after antenatal ETX restores lung growth and prevents pulmonary hypertension during infancy.
Resumo:
We analyzed Brazil`s efforts in reducing child mortality, improving maternal and child health, and reducing socioeconomic and regional inequalities from 1990 through 2007. We compiled and reanalyzed data from several sources, including vital statistics and population-based surveys. We also explored the roles of broad socioeconomic and demographic changes and the introduction of health sector and other reform measures in explaining the improvements observed. Our findings provide compelling evidence that pro-active measures to reduce health disparities accompanied by socioeconomic progress can result in measurable improvements in the health of children and mothers in a relatively short interval. Our analysis of Brazil`s successes and remaining challenges to reach and surpass Millennium Development Goals 4 and 5 can provide important lessons for other low- and middle-income countries. (Am J Public Health. 2010;100:1877-1889. doi:10.2105/AJPH.2010.196816)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJECTIVE: To evaluate the effects of 2 different doses of exogenous surfactant on pulmonary mechanics and on the regularity of pulmonary parenchyma inflation in newborn rabbits. METHOD: Newborn rabbits were submitted to tracheostomy and randomized into 4 study groups: the Control group did not receive any material inside the trachea; the MEC group was instilled with meconium, without surfactant treatment; the S100 and S200 groups were instilled with meconium and were treated with 100 and 200 mg/kg of exogenous surfactant (produced by Instituto Butantan) respectively. Animals from the 4 groups were mechanically ventilated during a 25-minute period. Dynamic compliance, ventilatory pressure, tidal volume, and maximum lung volume (P-V curve) were evaluated. Histological analysis was conducted using the mean linear intercept (Lm), and the lung tissue distortion index (SDI) was derived from the standard deviation of the means of the Lm. One-way analysis of variance was used with a = 0.05. RESULTS: After 25 minutes of ventilation, dynamic compliance (mL/cm H2O.kg) was 0.87 +/- 0.07 (Control); 0.49 +/- 0.04 (MEC*); 0.67 +/- 0.06 (S100); and 0.67 +/- 0.08 (S200), and ventilatory pressure (cm H2O) was 9.0 +/- 0.9 (Control); 16.5 +/- 1.7 (MEC*); 12.4 +/- 1.1 (S100); and 12.1 +/- 1.5 (S200). Both treated groups had lower Lm values and more homogeneity in the lung parenchyma compared to the MEC group: SDI = 7.5 +/- 1.9 (Control); 11.3 +/- 2.5 (MEC*), 5.8 +/- 1.9 (S100); and 6.7 +/- 1.7 (S200) (*P < 0.05 versus all the other groups). CONCLUSIONS: Animals treated with surfactant showed significant improvement in pulmonary mechanics and more regularity of the lung parenchyma in comparison to untreated animals. There was no difference in results after treatment with either of the doses used.
Resumo:
Congenital epulis (CE) of the newborn is a rare benign soft tissue tumor that presents at birth. It occurs usually as a single mass with various sizes, although some multiple lesions have also been reported. The lesion is more common in female neonates and normally affects the maxillary alveolar ridge. Rare recurrence and no malignant alteration have also been reported. This condition may interfere with respiration, feeding or adequate closure of the mouth. A decisive diagnosis is made by histopathologic analysis as other newborn lesions can be incorrectly diagnosed as CE. This article presents a case report of a female infant who presented a fibrotic mass in the primary lateral incisor and canine region of the maxillary alveolar ridge. The lesion was not causing feeding or respiratory problems. After a watchful waiting procedure and no spontaneous regression, the lesion was excised under local anesthesia and confirmed by histopathologic analysis as CE.