950 resultados para Network load
Resumo:
The cost and limited flexibility of traditional approaches to 11kV network reinforcement threatens to constrain the uptake of low carbon technologies. Ofgem has released £500m of funding for DNOs to trial innovative techniques and share the learning with the rest of the industry. One of the techniques under study is the addition of Energy Storage at key substations to the network to help with peak load lopping. This paper looks in detail at the sizing algorithm for use in the assessment of alternatives to traditional reinforcement and investigates a method of sizing a battery for use on a Network taking into account load growth, capacity fade and battery lifecycle issues. A further complication to the analysis is the method of operation of the battery system and how this affects the Depth of Discharge (DoD). The proposed method is being trialled on an area of 11kV network in Milton Keynes Central area and the simulation results are presented in this paper.
Resumo:
Dynamic asset rating is one of a number of techniques that could be used to facilitate low carbon electricity network operation. This paper focusses on distribution level transformer dynamic rating under this context. The models available for use with dynamic asset rating are discussed and compared using measured load and weather conditions from a trial Network area within Milton Keynes. The paper then uses the most appropriate model to investigate, through simulation, the potential gains in dynamic rating compared to static rating under two transformer cooling methods to understand the potential gain to the Network Operator.
Resumo:
Since privatisation, maintenance of DNO LV feeder maximum demand information has gradually demised in some Utility Areas, and it is postulated that lack of knowledge about 11kV and LV electrical networks is resulting in a less economical and energy efficient Network as a whole. In an attempt to quantify the negative impact, this paper examines ten postulated new connection scenarios for a set of real LV load readings, in order to find the difference in design solutions when LV load readings were and were not known. The load profiles of the substations were examined in order to explore the utilisation profile. It was found that in 70% of the scenarios explored, significant cost differences were found. These cost differences varied by an average of 1000%, between schemes designed with and without load readings. Obviously, over designing a system and therefore operating more, underutilised transformers becomes less financially beneficial and less energy efficient. The paper concludes that new connection design is improved in terms of cost when carried out based on known LV load information and enhances the case for regular maximum feeder demand information and/or metering of LV feeders. © 2013 IEEE.
Resumo:
This paper looks at how automatic load transfer may be used as a possible planning tool to help deliver faster connections for customers. A trial on an area of overhead line Network is presented to show how improvements in % feeder utilisation may be realised by changing the location of the open point. The reported Network data is compared to calculated data under two different configurations over a two week trial period. The results show that ALT open point determination in the presence of generation is different from a load only circuit and that the open points may not be fixed with time. Looking at improvements in Network headroom may not be conducive to other improvements in the network such as loss reduction or improving voltage profiles.
Resumo:
The purpose of this study was to analyze the network performance by observing the effect of varying network size and data link rate on one of the most commonly found network configurations. Computer networks have been growing explosively. Networking is used in every aspect of business, including advertising, production, shipping, planning, billing, and accounting. Communication takes place through networks that form the basis of transfer of information. The number and type of components may vary from network to network depending on several factors such as requirement and actual physical placement of the networks. There is no fixed size of the networks and they can be very small consisting of say five to six nodes or very large consisting of over two thousand nodes. The varying network sizes make it very important to study the network performance so as to be able to predict the functioning and the suitability of the network. The findings demonstrated that the network performance parameters such as global delay, load, router processor utilization, router processor delay, etc. are affected. The findings demonstrated that the network performance parameters such as global delay, load, router processor utilization, router processor delay, etc. are affected significantly due to the increase in the size of the network and that there exists a correlation between the various parameters and the size of the network. These variations are not only dependent on the magnitude of the change in the actual physical area of the network but also on the data link rate used to connect the various components of the network.
Resumo:
With the growing commercial importance of the Internet and the development of new real-time, connection-oriented services like IP-telephony and electronic commerce resilience is becoming a key issue in the design of TP-based networks. Two emerging technologies, which can accomplish the task of efficient information transfer, are Multiprotocol Label Switching (MPLS) and Differentiated Services. A main benefit of MPLS is the ability to introduce traffic-engineering concepts due to its connection-oriented characteristic. With MPLS it is possible to assign different paths for packets through the network. Differentiated services divides traffic into different classes and treat them differently, especially when there is a shortage of network resources. In this thesis, a framework was proposed to integrate the above two technologies and its performance in providing load balancing and improving QoS was evaluated. Simulation and analysis of this framework demonstrated that the combination of MPLS and Differentiated services is a powerful tool for QoS provisioning in IP networks.
Resumo:
Automatic load transfer (ALT) on the 11 kV network is the process by which circuit breakers on the network are switched to form open points in order to feed load from different primary substations. Some of the potential benefits that may be gained from dynamically using ALT include maximising utilisation of existing assets, voltage regulation and reduced losses. One of the key issues, that has yet to be properly addressed in published research, is how to validate that the modelled benefits really exist. On an 11 kV distribution network where the load is continually changing and the load on each distribution substation is unlikely to be monitored - reduction in losses from moving the normally open point is particularly difficult to prove. This study proposes a method to overcome this problem and uses measured primary feeder data from two parts of the Western Power Distribution 11 kV Network under different configurations. The process of choosing the different configurations is based on a heuristic modelling method of locating minimum voltages to help reduce losses.
Resumo:
The energy consumption by ICT (Information and Communication Technology) equipment is rapidly increasing which causes a significant economic and environmental problem. At present, the network infrastructure is becoming a large portion of the energy footprint in ICT. Thus the concept of energy efficient or green networking has been introduced. Now one of the main concerns of network industry is to minimize energy consumption of network infrastructure because of the potential economic benefits, ethical responsibility, and its environmental impact. In this paper, the energy management strategies to reduce the energy consumed by network switches in LAN (Local Area Network) have been developed. According to the lifecycle assessment of network switches, during usage phase, the highest amount of energy consumed. The study considers bandwidth, link load and traffic matrixes as input parameters which have the highest contribution in energy footprint of network switches during usage phase and energy consumption as output. Then with the objective of reducing energy usage of network infrastructure, the feasibility of putting Ethernet switches hibernate or sleep mode was investigated. After that, the network topology was reorganized using clustering method based on the spectral approach for putting network switches to hibernate or switched off mode considering the time and communications among them. Experimental results show the interest of this approach in terms of energy consumption
Resumo:
Two trends are emerging from modern electric power systems: the growth of renewable (e.g., solar and wind) generation, and the integration of information technologies and advanced power electronics. The former introduces large, rapid, and random fluctuations in power supply, demand, frequency, and voltage, which become a major challenge for real-time operation of power systems. The latter creates a tremendous number of controllable intelligent endpoints such as smart buildings and appliances, electric vehicles, energy storage devices, and power electronic devices that can sense, compute, communicate, and actuate. Most of these endpoints are distributed on the load side of power systems, in contrast to traditional control resources such as centralized bulk generators. This thesis focuses on controlling power systems in real time, using these load side resources. Specifically, it studies two problems.
(1) Distributed load-side frequency control: We establish a mathematical framework to design distributed frequency control algorithms for flexible electric loads. In this framework, we formulate a category of optimization problems, called optimal load control (OLC), to incorporate the goals of frequency control, such as balancing power supply and demand, restoring frequency to its nominal value, restoring inter-area power flows, etc., in a way that minimizes total disutility for the loads to participate in frequency control by deviating from their nominal power usage. By exploiting distributed algorithms to solve OLC and analyzing convergence of these algorithms, we design distributed load-side controllers and prove stability of closed-loop power systems governed by these controllers. This general framework is adapted and applied to different types of power systems described by different models, or to achieve different levels of control goals under different operation scenarios. We first consider a dynamically coherent power system which can be equivalently modeled with a single synchronous machine. We then extend our framework to a multi-machine power network, where we consider primary and secondary frequency controls, linear and nonlinear power flow models, and the interactions between generator dynamics and load control.
(2) Two-timescale voltage control: The voltage of a power distribution system must be maintained closely around its nominal value in real time, even in the presence of highly volatile power supply or demand. For this purpose, we jointly control two types of reactive power sources: a capacitor operating at a slow timescale, and a power electronic device, such as a smart inverter or a D-STATCOM, operating at a fast timescale. Their control actions are solved from optimal power flow problems at two timescales. Specifically, the slow-timescale problem is a chance-constrained optimization, which minimizes power loss and regulates the voltage at the current time instant while limiting the probability of future voltage violations due to stochastic changes in power supply or demand. This control framework forms the basis of an optimal sizing problem, which determines the installation capacities of the control devices by minimizing the sum of power loss and capital cost. We develop computationally efficient heuristics to solve the optimal sizing problem and implement real-time control. Numerical experiments show that the proposed sizing and control schemes significantly improve the reliability of voltage control with a moderate increase in cost.
Resumo:
The current infrastructure as a service (IaaS) cloud systems, allow users to load their own virtual machines. However, most of these systems do not provide users with an automatic mechanism to load a network topology of virtual machines. In order to specify and implement the network topology, we use software switches and routers as network elements. Before running a group of virtual machines, the user needs to set up the system once to specify a network topology of virtual machines. Then, given the user’s request for running a specific topology, our system loads the appropriate virtual machines (VMs) and also runs separated VMs as software switches and routers. Furthermore, we have developed a manager that handles physical hardware failure situations. This system has been designed in order to allow users to use the system without knowing all the internal technical details.
Resumo:
This paper presents a methodology to forecast the hourly and daily consumption in households. The methodology was validated for households in Lisbon region, Portugal. The paper shows that the forecast tool allows obtaining satisfactory results for forecasting. Models of demand response allow the support of consumer’s decision in exchange for an economic benefit by the redefinition of load profile or changing the appliance consumption period. It is also in the interest of electric utilities to take advantage of these changes, particularly when consumers have an action on the demand-side management or production. Producers need to understand the load profile of households that are connected to a smart grid, to promote a better use of energy, as well as optimize the use of micro-generation from renewable sources, not only to delivering to the network but also in self-consumption.
Resumo:
This paper presents a methodology for short-term load forecasting based on genetic algorithm feature selection and artificial neural network modeling. A feed forward artificial neural network is used to model the 24-h ahead load based on past consumption, weather and stock index data. A genetic algorithm is used in order to find the best subset of variables for modeling. Three data sets of different geographical locations, encompassing areas of different dimensions with distinct load profiles are used in order to evaluate the methodology. The developed approach was found to generate models achieving a minimum mean average percentage error under 2 %. The feature selection algorithm was able to significantly reduce the number of used features and increase the accuracy of the models.