928 resultados para Metrics (Quantitative assessment).


Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Diabetics have a significantly higher percentage of sperm with nuclear DNA (nDNA) fragmentation and increased levels of advanced glycation end products (AGEs), in their testis, epididymis and sperm. As the receptor for AGEs (RAGE) is important to oxidative stress and cell dysfunction, we hypothesise, that it may be involved in sperm nDNA damage. METHODS: Immunohistochemistry was performed to determine the presence of RAGE in the human testis and epididymis. A comparison of the receptor's incidence and localisation on sperm from 10 diabetic and 11 non-diabetic men was conducted by blind semi-quantitative assessment of the immunostaining. ELISA analysis ascertained RAGE levels in seminal plasma and sperm from 21 diabetic and 31 non-diabetic subjects. Dual labelling immunolocalisation was employed to evaluate RAGE's precise location on the sperm head. RESULTS: RAGE was found throughout the testis, caput epididymis, particularly the principle cells apical region, and on sperm acrosomes. The number of sperm displaying RAGE and the overall protein amount found in sperm and seminal plasma were significantly higher in samples from diabetic men (p

Relevância:

80.00% 80.00%

Publicador:

Resumo:

14C wiggle-match dating (WMD) of peat deposits uses the non-linear relationship between 14C age and calendar age to match the shape of a sequence of closely spaced peat 14C dates with the 14C calibration curve. A numerical approach to WMD enables the quantitative assessment of various possible wiggle-match solutions and of calendar year confidence intervals for sequences of 14C dates. We assess the assumptions, advantages, and limitations of the method. Several case-studies show that WMD results in more precise chronologies than when individual 14C dates are calibrated. WMD is most successful during periods with major excursions in the 14C calibration curve (e.g., in one case WMD could narrow down confidence intervals from 230 to 36 yr).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Twenty-four shed-reared lambs were each infected orally with 250 metacercariae of Fasciola hepatica, using either the triclabendazole (TCBZ)-sensitive Cullompton isolate or the TCBZ-resistant Sligo isolate. Twelve weeks after infection the lambs were treated with TCBZ (10 mg/kg) or with the experimental fasciolicide, Compound Alpha (Cpd alpha), a benzimidazole derivative of TCBZ (15 mg/kg). The lambs were euthanised 48,72 and 96 h after TCBZ treatment, or 24, 48 and 72 h after Cpd a treatment, and flukes were collected from the liver and/or gall bladder of each animal. Untreated animals harbouring 12-week infections were euthanised 24 h after administration of anthelmintic to the treatment groups, and the untreated flukes provided control material. A semi-quantitative assessment of the degree of histological change induced by the two drugs after different times of exposure was achieved by scoring the intensity of three well-defined lesions that developed in the testes and uteri of a representative sample of flukes from each lamb. In general, it was found that in those tissues where active meiosis and/or mitosis occurred (testis, ovary, and vitelline follicles), there was progressive loss of cell content due to apparent failure of cell division to keep pace with expulsion of the mature or effete products. Further, actively dividing cell types tended to become individualised, rounded and condensed, characteristic of apoptotic cell death. Protein synthetic activity was apparently inhibited in the Mehlis' secretory cells. In the uterus, where successful formation of shelled eggs represents the culmination of a complex sequence of cytokinetic, cytological and synthetic activity involving the vitelline follicles, the ovary and the Mehlis' gland, histological evidence indicating failure of ovigenesis was evident from 24 h post-treatment onwards. The development of these lesions may be related to the known antitubulin activity of the benzimidazole class of anthelmintics, to the induction of apoptosis in cells where mitosis or meiosis has aborted due to failure of spindle formation, and to drug-induced inhibition of protein synthesis. The semi-quantitative findings indicated that Cpd a is slightly less efficacious than TCBZ itself in causing histological damage to the reproductive structures of TCBZ-sensitive flukes, and that, like TCBZ, it caused no histological damage in flukes of the TCBZ-resistant isolate. This study illustrates the potential utility of histological techniques for conveniently screening representative samples of flukes in field trials designed to validate instances of drug resistance or to test the efficacy of new products against known drug-resistant and drug-susceptible fluke isolates. It also provides reference criteria for drug-induced histopathological changes in fluke reproductive structures which may aid interpretation of TEM findings. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We aimed to develop a clinically relevant delayed union/non-union fracture model to evaluate a cell therapy intervention repair strategy. Histology, three-dimensional (3D) micro-computed tomography (micro-CT) imaging and mechanical testing were utilized to develop an analytical protocol for qualitative and quantitative assessment of fracture repair. An open femoral diaphyseal osteotomy, combined with periosteal diathermy and endosteal excision, was held in compression by a four pin unilateral external fixator. Three delayed union/non-union fracture groups established at 6 weeks-(a) a control group, (b) a cell therapy group, and (c) a group receiving phosphate-buffered saline (PBS) injection alone-were examined subsequently at 8 and 14 weeks. The histological response was combined fibrous and cartilaginous non-unions in groups A and B with fibrous non-unions in group C. Mineralized callus volume/total volume percentage showed no statistically significant differences between groups. Endosteal calcified tissue volume/endosteal tissue volume, at the center of the fracture site, displayed statistically significant differences between 8 and 14 weeks for cell and PBS intervention groups but not for the control group. The percentage load to failure was significantly lower in the control and cell treatment groups than in the PBS alone group. High-resolution micro-CT imaging provides a powerful tool to augment characterization of repair in delayed union/non-union fractures together with outcomes such as histology and mechanical strength measurement. Accurate, nondestructive, 3D identification of mineralization progression in repairing fractures is enabled in the presence or absence of intervention strategies. (c) 2007 Orthopaedic Research Society.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A qualitative analysis of the cationic profile of bovine and ovine biles and of bovine, ovine and rat liver flukes has been carried out by DC are emission spectrography. A quantitative assessment of the concentrations of Na+, K+, Ca2+ and Mg2+ ions in bovine, ovine and rat flukes has been determined by atomic absorption spectrophotometry. The levels of these ions in bovine and ovine bile samples have also been assessed and compared with those of Hedon-Heig saline. The ionic composition of the two biles is similar and the concentration of each ion is greater than that in Hedon-Heig saline. Despite the similarity in biles, ion levels in bovine flukes are generally higher than those in ovine flukes. Ion levels in rat flukes are different again but show closer similarity to those in bovine, not ovine, flukes. The results are discussed in relation to the proposed operation of the osmoregulatory system in the fluke.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Micro-mechanical analysis of polymeric composites provides a powerful means for the quantitative assessment of their bulk behavior. In this paper we describe a robust finite element model (FEM) for the micro-structural modeling of the behavior of particulate filled polymer composites under external loads. The developed model is applied to simulate stress distribution in polymer composites containing particulate fillers. Quantitative information about the magnitude and location of maximum stress concentrations obtained from these simulations is used to predict the dominant failure and crack growth mechanisms in these composites. The model predictions are compared with the available experimental data and also with the values found using other methods reported in the literature. These comparisons show the range of the validity of the developed model and its predictive potential.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background

Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR.Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment of macular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO.

Objectives

To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists after DR is detected. In the update of this review we also aimed to assess whether OCT might be considered the new reference standard for detecting DMO.

Search methods

We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1990 to June 2013), BIOSIS Previews (January 1969 to June 2013), MEDION and the Aggressive Research Intelligence Facility database (ARIF). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 25 June 2013. We checked bibliographies of relevant studies for additional references.

Selection Criteria

We selected studies that assessed the diagnostic accuracy of any OCT model for detecting DMO or CSMO in patients with DR who were referred to eye clinics. Diabetic macular oedema and CSMO were diagnosed by means of fundus biomicroscopy by ophthalmologists or stereophotography by ophthalmologists or other trained personnel.

Data collection and analysis

Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data using random-effects hierarchical sROC meta-analysis models.

Main results

We included 10 studies (830 participants, 1387 eyes), published between 1998 and 2012. Prevalence of CSMO was 19% to 65% (median 50%) in nine studies with CSMO as the target condition. Study quality was often unclear or at high risk of bias for QUADAS 2 items, specifically regarding study population selection and the exclusion of participants with poor quality images. Applicablity was unclear in all studies since professionals referring patients and results of prior testing were not reported. There was a specific 'unit of analysis' issue because both eyes of the majority of participants were included in the analyses as if they were independent.In nine studies providing data on CSMO (759 participants, 1303 eyes), pooled sensitivity was 0.78 (95% confidence interval (CI) 0.72 to 0.83) and specificity was 0.86 (95% CI 0.76 to 0.93). The median central retinal thickness cut-off we selected for data extraction was 250 µm (range 230 µm to 300 µm). Central CSMO was the target condition in all but two studies and thus our results cannot be applied to non-central CSMO.Data from three studies reporting accuracy for detection of DMO (180 participants, 343 eyes) were not pooled. Sensitivities and specificities were about 0.80 in two studies and were both 1.00 in the third study.Since this review was conceived, the role of OCT has changed and has become a key ingredient of decision-making at all levels of ophthalmic care in this field. Moreover, disagreements between OCT and fundus examination are informative, especially false positives which are referred to as subclinical DMO and are at higher risk of developing clinical CSMO.

Authors' conclusions

Using retinal thickness thresholds lower than 300 µm and ophthalmologist's fundus assessment as reference standard, central retinal thickness measured with OCT was not sufficiently accurate to diagnose the central type of CSMO in patients with DR referred to retina clinics. However, at least OCT false positives are generally cases of subclinical DMO that cannot be detected clinically but still suffer from increased risk of disease progression. Therefore, the increasing availability of OCT devices, together with their precision and the ability to inform on retinal layer structure, now make OCT widely recognised as the new reference standard for assessment of DMO, even in some screening settings. Thus, this review will not be updated further.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two arsenic- and heavy metal-contaminated mine-spoil sites, at Carrock Fell, Cumbria and Devon Great Consols Mine, Devon, were found to support populations of the earthworms Lumbricus rubellus Hoffmeister and Dendrodrilus rubidus (Savigny). L. rubellus and D. rubidus collected from the Devon site and an uncontaminated site were kept for 28 days in uncontaminated soil and in soil containing sodium arsenate (494 mg As kg-1). The state of the specimens was recorded every 7 days using a semi-quantitative assessment of earthworm health (condition index, C. I.). The C. I. remained high for all specimens except those of L. rubellus and D. rubidus from uncontaminated sites, which displayed 60 and 10% mortality, respectively. L. rubellus collected from the Carrock Fell site, and L. rubellus and D. rubidus from an uncontaminated site, burrowed as rapidly into soil containing up to 1235 mg As kg-1 in the form of sodium arsenate as into uncontaminated soil when placed on the soil surface. When earthworms were allowed a choice between uncontaminated soil and soil contaminated with sodium arsenate in concentrations of up to 1235 mg As kg-1, the threshold concentration for avoidance of contaminated soil was lower for L. rubellus and D. rubidus from uncontaminated soil than for specimens from contaminated soil. There was no significant effect of pH on soil discrimination. The LC50 concentration of As for L. rubellus from Devon Great Consols was significantly higher (P < 0.001) than for L. rubellus from the uncontaminated site: 1510 and 96 mg As kg-1, respectively. © 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente trabalho teve por objectivo global o estudo e desenvolvimento de sensores baseados em fibra óptica polimérica. O crescimento da tecnologia polimérica nos últimos anos permitiu a introdução deste tipo de fibras ópticas na área das telecomunicações e no desenvolvimento de sensores. As vantagens associadas à metrologia óptica com fibra polimérica têm vindo a atrair as atenções da comunidade científica dado que permitem o desenvolvimento de sistemas de baixo-custo ou custo competitivo face às tecnologias convencionais. Dada a actualidade do tema proposto, descreve-se, numa primeira fase, a tecnologia em fibra óptica polimérica existente no mercado e o estado de arte de sensores em fibra óptica polimérica. Segue-se a descrição de dois tipos de sensores baseados em modulação de intensidade. Projectou-se um sensor extrínseco capaz de avaliar a quantidade de luz dispersa e absorvida por partículas suspensas num líquido. Foi efectuada a caracterização do sensor quanto à concentração de partículas suspensas, tamanho e reflectividade. O sensor foi testado no âmbito da monitorização ambiental, designadamente, na análise de turbidez em amostras de sedimentos recolhidos em áreas ardidas. O sistema desenvolvido foi comparado com um sistema comercial. Um sensor intrínseco, baseado no polimento lateral de fibra óptica polimérica, foi analisado analiticamente. O modelo teórico avalia o sensor em diferentes condições de macroencurvamento e de índice de refracção do meio envolvente. O modelo teórico foi validado positivamente através de resultados experimentais. Foi avaliada a sensibilidade à temperatura e os conhecimentos adquiridos foram aplicados no desenvolvimento de um sistema capaz de monitorizar a cura de diferentes materiais. É ainda apresentada uma técnica para melhorar a sensibilidade do sensor de curvatura através da aplicação de um revestimento na zona sensível. A dependência na curvatura da potência transmitida por uma fibra óptica polida lateralmente serviu de base ao desenvolvimento de uma joelheira e de uma cotoveleira instrumentada, capazes de avaliar quantitativamente o movimento articular. A necessidade de portabilidade levou ao desenvolvimento de um sistema sem fios para aquisição e transmissão de dados. Espera-se que os protótipos desenvolvidos venham a ter um impacto significativo em sistemas futuros aplicados à medicina física e reabilitação.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Water-soluble organic matter (WSOM) from atmospheric particles comprises a complex array of molecular structures that play an important role on the physic-chemical properties of atmospheric particles and, therefore, are linked to several global-relevant atmospheric processes which impact the climate and public health. Due to the large variety of sources and formation processes, adequate knowledge on WSOM composition and its effects on the properties of atmospheric aerosol are still limited. Therefore, this thesis aims at providing new insights on the molecular composition of WSOM from fine atmospheric aerosols typical of an urban area (Aveiro, Portugal). In a first step, adsorption phenomena of semivolatile organic compounds on quartz fibre filters employed in the collection of atmospheric aerosols were assessed. Afterwards, atmospheric aerosol samples were collected during fifteen months, on a weekly basis. A mass balance of aerosol samples was performed in order to set the relative contribution of elemental carbon, WSOM and water-insoluble organic matter to the aerosol mass collected at the urban area of Aveiro, with a special focus on the assessment of the influence of different meteorological conditions. In order to assess the chemical complexity of the WSOM from urban aerosols, their structural characteristics were studied by means of Fourier transform infrared infrared - Attenuated Total Reflectance (FTIR-ATR) and solid-state cross polarization with magic angle spinning 13C nuclear magnetic resonance (CPMAS 13C NMR) spectroscopies, as well as their elemental composition. The structural characterization of aerosol WSOM samples collected in the urban area highlighted a highly complex mixture of functional groups. It was concluded that aliphatic and aromatic structures, hydroxyl groups and carboxyl groups are characteristic to all samples. The semi-quantitative assessment of the CPMAS 13C NMR data showed different distributions of the various functional groups between the aerosol samples collected at different seasons. Moreover, the presence of signals typical of lignin-derived structures in both CPMAS 13C NMR and FTIR-ATR spectra of the WSOM samples from the colder seasons, highlights the major contribution of biomass burning processes in domestic fireplaces, during low temperature conditions, into the bulk chemical properties of WSOM from urban aerosols. A comprehensive two-dimensional liquid chromatography (LC x LC) method, on-line coupled to a diode array, fluorescence, and evaporative light scattering detectors, was employed for resolving the chemical heterogeneity of the aerosol WSOM samples and, simultaneously, to map the hydrophobicity versus the molecular weight distribution of the samples. The LC x LC method employed a mixed-mode hydrophilic interaction column operating under aqueous reversed phase mode in the first dimension, and a size-exclusion column in the second dimension, which was found to be useful for separating the aerosol WSOM samples into various fractions with distinct molecular weight and hydrophobic features. The estimative of the average molecular weight (Mw) distribution of the urban aerosol WSOM samples ranged from 48 to 942 Da and from 45 to 1241 Da in terms of UV absorption and fluorescence detection, respectively. Findings suggest that smaller Mw group fractions seem to be related to a more hydrophobic nature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica Perfil de Manutenção e Produção

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertation to obtain the degree of Doctor in Electrical and Computer Engineering, specialization of Collaborative Networks

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Para garantir que um equipamento opere com segurança e fiabilidade durante o seu ciclo de vida, desde a sua instalação ao desmantelamento, devem ser realizadas inspeções e/ou monitorizações que, dependendo dos dados recolhidos, podem implicar avaliações Fitness- For-Service (FFS) que definirão a necessidade de reparação ou alteração do equipamento ou das condições processuais. A combinação de inspeção ou monitorização com os melhores procedimentos e técnicas de avaliação atuais fazem sobressair insuficiências dos procedimentos mais antigos. Usando métodos mais avançados de avaliação, validados e suportados através de uma vasta experiência de campo, pode-se agora avaliar defeitos nos ativos (equipamentos) e determinar a adequação ao serviço com uma análise FFS. As análises FFS tornaram-se cada vez mais aceites em toda a indústria ao longo dos últimos anos. A norma API 579 - 1/ASME FFS-1: 2007 fornece diretrizes para avaliar os tipos de danos que afetam os equipamentos processuais e a norma API RP 571: 2011 descreve os mecanismos de degradação que afetam os equipamentos nas petroquímicas e refinarias, que incluem os danos por corrosão, desalinhamentos, deformações plásticas, laminações, fissuras, entre outros. Este trabalho consiste na análise de Integridade Estrutural de uma Flare Industrial que surgiu da necessidade real de análise do equipamento no âmbito da atividade profissional do candidato. O estudo realizado a nível profissional é de grande abrangência, incluindo a inspeção do equipamento, identificação da falha ou dano, recolha e registo de dados, definição de estratégia de atuação e seleção de técnicas de avaliação da condição para posterior alteração, reparação ou desmantelamento. Na presente dissertação de mestrado em Engenharia Mecânica, Ramo Construções Mecânicas, pretende-se efetuar o estudo aprofundado de uma das etapas de projeto, nomeadamente estudar a causa, avaliar a falha e implicações estruturais ou processuais devido à degradação interior do riser de uma flare, com base numa análise FFS, assumindo a operabilidade em segurança e garantindo resolutas condições de funcionamento. A presente análise FFS tem como finalidade validar ou não a integridade atual (avaliação técnica quantitativa) de modo a conhecer se o item em questão é seguro e confiável para continuar a operar em condições específicas durante um período de tempo determinado, tendo em consideração as condições verificadas no ato de inspeção e especificações de projeto, segundo os itens de verificação de segurança estabelecidos na norma EN 1990:2002/A1:2005/AC:2010 e com base na norma API 579-1/ASME FFS-1: 2007. No âmbito do presente trabalho foram realizadas as seguintes tarefas: - Identificar e analisar os mecanismos de degradação com base na norma API RP 571: 2011, face às condições processuais e geométricas que o equipamento em análise está sujeito de modo a perceber a evolução da degradação estrutural e quais as implicações na sua longevidade. - Avaliar e propor soluções de reparação e ou alterações processuais e ou geométricas do equipamento em análise de modo a permitir a continuidade em funcionamento sem afetar as condições de segurança e por conseguinte minimizar ou evitar o elevado custo económico associado a um novo equipamento e tempo de paragem processual. - Assumir limites estruturais face às condições processuais e ações externas ou adjacentes. - Garantir a segurança e qualidade da vida humana ou meio que o rodeia, do equipamento, das instalações, das infraestruturas envolventes e evitar o colapso económico, quer por motivos processuais, quer indeminizações ou agravamento do prémio do seguro. Verificou-se que os resultados serão a base para as alterações inerentes, tais como reforço estrutural, alteração da geometria do defletor, ajuste no tensionamento dos cabos e controlo da espessura mínima, de modo a alargar o período de vida útil da flare com segurança.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Following the European Commission’s 2009 Recommendation on the Regulatory Treatment of Fixed and Mobile Termination Rates in the EU, the Portuguese regulatory authority (ANACOM) decided to reduce termination prices in mobile networks to their long-run incremental cost (LRIC). Nevertheless, no serious quantitative assessment of the potential effects of this decision was carried out. In this paper, we adapt and calibrate the Harbord and Hoernig (2014) model of the UK mobile telephony market to the Portuguese reality, and simulate the likely impact on consumer surplus, profits and welfare of four different regulatory approaches: pure LRIC, reciprocal termination charges with fixed networks, “bill & keep”, and asymmetric termination rates. Our results show that reducing MTRs does increase social welfare, profits and consumer surplus in the fixed market, but mobile subscribers are seriously harmed by this decision.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Infrared thermography is a non-invasive technique that measures mid to long-wave infrared radiation emanating from all objects and converts this to temperature. As an imaging technique, the value of modern infrared thermography is its ability to produce a digitized image or high speed video rendering a thermal map of the scene in false colour. Since temperature is an important environmental parameter influencing animal physiology and metabolic heat production an energetically expensive process, measuring temperature and energy exchange in animals is critical to understanding physiology, especially under field conditions. As a non-contact approach, infrared thermography provides a non-invasive complement to physiological data gathering. One caveat, however, is that only surface temperatures are measured, which guides much research to those thermal events occurring at the skin and insulating regions of the body. As an imaging technique, infrared thermal imaging is also subject to certain uncertainties that require physical modeling, which is typically done via built-in software approaches. Infrared thermal imaging has enabled different insights into the comparative physiology of phenomena ranging from thermogenesis, peripheral blood flow adjustments, evaporative cooling, and to respiratory physiology. In this review, I provide background and guidelines for the use of thermal imaging, primarily aimed at field physiologists and biologists interested in thermal biology. I also discuss some of the better known approaches and discoveries revealed from using thermal imaging with the objective of encouraging more quantitative assessment.