959 resultados para Malpositioned implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to investigate the healing, integration, and maintenance of autogenous onlay bone grafts and implant osseointegration either loaded in the early or the delayed stages. Materials and Methods: A total of 5 male clogs received bilateral blocks of onlay bone grafts harvested from the contralateral alveolar ridge of the mandible. On one side, the bone block was secured by 3 dental implants (3.5 mm x 13.0 mm, Osseospeed; Astra Tech AB, Molndal, Sweden). Two implants at the extremities of the graft were loaded 2 clays after installation by abutment connection and prosthesis (simultaneous implant placement group); the implant in the middle remained unloaded and served as the control. On the other side, the block was fixed with 2 fixation screws inserted in the extremities of the graft. Four weeks later, the fixation screws were replaced with 3 dental implants. The loading procedure (delayed implant placement group) was performed 2 clays later, as described for the simultaneous implant placement sites. The animals were sacrificed 12 weeks after the grafting procedure. Implant stability was measured through resonance frequency analysis. The bone volume and density were assessed on computed tomography. The bone to implant contact and bone area in a region of interest were evaluated on histologic slides. Results: The implant stability quotient showed statistical significance in favor of the delayed loaded grafts (P=.001). The bone-to-implant contact (P=.008) and bone area in a region of interest (P=0.005) were significantly greater in the delayed group. Nevertheless, no difference was found in terms of graft volume and density between the early loaded and delayed-loaded approaches. Conclusions: The protocol in which the implant and bone graft were given delayed loading allows for effective quality of implant osseointegration and stabilization, with healing and remodeling occurring in areas near the implant resulting in denser bone architecture. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Sing 68:825-832, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Physical and bioceramic incorporation surface treatments at the nanometer scale showed higher means of bone-to-implant contact (BIC) and torque values compared with surface topography at the micrometer scale; however, the literature concerning the effect of nanometer scale parameters is sparse. Purpose: The aim of this study was to evaluate the influence of two different implant surfaces on the percentage bone-to-implant contact (BIC%) and bone osteocyte density in the human posterior maxilla after 2 months of unloaded healing. Materials and Methods: The implants utilized presented dual acid-etched (DAE) surface and a bioceramic molecular impregnated treatment (Ossean(R), Intra-Lock International, Boca Raton, FL, USA) serving as control and test, respectively. Ten subjects (59 1 9 years of age) received two implants (one of each surface) during conventional implant surgery in the posterior maxilla. After the non-loaded period of 2 months, the implants and the surrounding tissue were removed by means of a trephine and were non-decalcified processed for ground sectioning and analysis of BIC%, bone density in threaded area (BA%), and osteocyte index (Oi). Results: Two DAE implants were found to be clinically unstable at time of retrieval. Histometric evaluation showed significantly higher BIC% and Oi for the test compared to the control surface (p < .05), and that BA% was not significantly different between groups. Wilcoxon matched pairs test was used to compare the differences of histomorphometric variables between implant surfaces. The significance test was conducted at a 5% level of significance. Conclusion: The histological data suggest that the bioceramic molecular impregnated surface-treated implants positively modulated bone healing at early implantation times compared to the DAE surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Recent studies in animals have shown pronounced resorption of buccal bone plate after immediate implantation. The sectioning of experimental material for histologic evaluation of the bone plates could provide valuable information about the possible effect of bone exposure in periodontal and implant surgeries. Methods: Twenty-four incisors were collected from dogs. After decalcification, the blocks were immersed in paraffin and bucco-lingual histologic sections were examined under light microscope. Some sections were reserved for immunohistochemical analysis. Results: The bone density, the width of the bone plates, and the percentage of vessels presented in the periodontal ligament and periosteum were analyzed in the buccal and lingual bone plates, which were divided corono-apically into thirds. The buccal bone plates showed statistically higher bone density compared to the lingual bone plates in the coronal thirds. The width of both bone plates increased from the coronal to the apical third, but all the buccal thirds were significantly thinner compared to the lingual thirds. No statistically significant differences were found between the bone plates for the percentage of area occupied by the blood vessels in the periodontal ligament or periosteum. Conclusion: It is reasonable to conclude that the higher bone density, represented by the lower number of marrow spaces, in association with the thinner aspect of the buccal bone plates made them more fragile to absorb compared to the lingual bone plates, especially during mucoperiosteal procedures. J Periodontol 2017;82:872-877.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent clinical studies, contamination of the inner parts of dental implants through bacterial penetration along the implant components has been observed. The aim of the present in-vitro study was to investigate leakage of Fusobacterium. nucleatum through the interface between implants and premachined or cast abutments. Both premachined (n = 10) and cast (n = 10) implant abutment assemblies were inoculated with 3.0 mu L of microbial inoculum. The assemblies were completely immersed in 5.0 mL of tryptic soy broth culture medium to observe leakage at the implant-abutment interface after 14 days of anaerobic incubation. Bacterial growth in the medium, indicative of microbial leakage, was found only in 1 out of 9 samples (11.1%) in each group. Both premachined and cast abutments connected to external hexagonal implants provide low percentages of bacterial leakage through the interface in in vitro unloaded conditions if the manufacturer`s instructions and casting procedures are properly followed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the biodimensional anatomical expander-implant system (BEIS) is a reliable technique, little information has been available regarding outcome following nipple-areola sparing mastectomy (NSM). To perform the resection of glandular tissue, while improving the surgical access and maintaining the nipple-areola vascularization we have developed a new approach for NSM based on the double concentric periareolar incision (DCPI). The purpose of this study is to analyze the feasibility, surgical planning and its outcome following NSM. 18 patients underwent NSM reconstructions. Mean time of follow-up was 29 months. The technique was indicated in patients with small/moderate volume breasts. Flap complications were evaluated and information on aesthetic results and patient satisfaction were collected. 83.3% had tumors measuring 2 cm or less (T1) and 72.1% were stage 0 and 1. All patients presented peripherally tumors located (at least 5 cm from the nipple). Skin complications occurred in 11.1%. One patient (5.5%) presented small skin necrosis and a wound dehiscence was observed in one patient (5.5%). The aesthetic result was good/very good in 94.4 percent and the majority of patients were very satisfied/satisfied. No local recurrences were observed. All complications except one were treated by a conservative approach. DCPI-BEIS is a simple and reliable technique for NSM reconstruction. The success depends on patient selection, coordinated planning with the oncologic surgeon and careful intra-operative and post-operative management. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study evaluated the effects of diclofenac sodium and meloxicam on peri-implant bone healing. Methods: Thirty male rats were divided into three groups: the control group (CG) received no drug; the diclofenac sodium group (DSG) received 1.07 mg/kg twice a day for 5 days; and the meloxicam group (MG) received 0.2 mg/kg daily for 5 days. A screw-shaped titanium implant was placed in the tibia. Fluorochromes, oxytetracycline (OxT), calcein (CA), and alizarin (AL), were injected at 7, 14, and 21 days, respectively, after implantation, and the animals were sacrificed 28 days after implant placement. The percentages of OxT-, CA-, and AL-labeled bone as well as the percentages of bone-to-implant contact (BIC), cortical bone area (CBA), and trabecular bone area (TBA) within the implant threads were evaluated. Results: Bone healing was delayed in the DSG during the first 14 days after implant placement (OxT-labeled bone: DSG: 5.3% +/- 7.3% versus CG: 13.2% +/- 9.8%, P= 0.002, and versus MG: 14.4% +/- 13.1%, P = 0.05). The percentages of BIC (DSG: 49.6% +/- 21.9%; MG: 67.1% +/- 22.8%; and CG: 68.1% +/- 22.8%) and CBA (DSG: 63.7% +/- 21.2%; MG: 82.7% +/- 12.4%; CG: 84.9% +/- 10.6%) were lower in the DSG compared to the MG and CG (P<0.001). The percentage of TBA was significantly greater in the DSG compared to the MG and CG (DSG: 36.3% +/- 21.2% versus MG: 17.3% +/- 12.7% and versus CG: 15.1% +/- 10.6%; P<0.001). Conclusion: Diclofenac sodium seemed to delay peri-implant bone healing and to decrease BIC, whereas meloxicam had no negative effect on peri-implant bone healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systemic inflammation after augmentation mammaplasty with modern silicone implants is not currently recognized. In a prospective controlled study, C-reactive protein and other variables were monitored, aiming to test this hypothesis in a young cohort of patients. Females (18-30 years old, BMI = 18.5-30 kg/m(2), N = 52) were consecutively recruited for breast implant (n = 24, Group I) and for abdominal liposuction (n = 28, Group II/Controls). Patients were interviewed at baseline and followed until 6 months after operation. Variables included demographic and clinical information, surgical outcome, inflammatory markers and autoantibodies. Operations were well tolerated, without surgical or infectious complications. Mean prosthesis size was 258 +/- A 21 ml (range = 220-280) and mean aspirate of liposuction was 1972 +/- A 499 ml (range = 1200-3000). Preoperative, 2-month, and 6-month C-reactive protein concentrations for breast implant patients were 1.3 +/- A 1.2, 4.8 +/- A 3.0, and 4.3 +/- A 6.4 mg/l and for liposuction 3.5 +/- A 2.7, 3.5 +/- A 2.1, and 2.2 +/- A 2.2 mg/l, respectively. Change at 2 months was significant (p = 0.001). Autoantibody investigation failed to reveal remarkable aberrations, except for anticardiolipin elevation, which was nearly symmetrical in the two groups. C-reactive protein levels increased after operation and correlated with proinflammatory and procoagulatory indices. A mild increase in anticardiolipin IgM occurred but differences between populations were lacking. Despite excellent cosmetic outcomes and lack of complications, acute phase reaction could signal ongoing immunogenicity of silicone and long-term monitoring is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The best way to study compensatory lung growth (CLG) is in a transplant without rejection. Since immunosuppressive drugs may influence CLG, it is better to not use them. Therefore we studied CLG in a reimplant of only one lobe after its removal. The objective was to compare lobar transplant CLG with CLG after lobectomy.Methods. Forty eight dogs were distributed in three groups: G1 = control, G2 = left cranial lobectomy, and G3 = left pneumonectomy with reimplantation of the caudal lobe. Five months after surgery the animals underwent lung scintigraphy and were sacrificed for morphometric study.Results. There was no correlation between scintigraphy and lung mass or lung volume. There was both mass and residual volume CLG in the operated groups, both contralateral and ipsilateral to surgery. There was no compensation for total lung capacity or compliance in the remaining caudal lobe (G2) or the reimplanted caudal lobe (G3) at 5 months after surgery. There was more damage in the reimplanted lobe. As previous studies have shown that CLG starts with increased mass and residual volume and compliance is compensated later. This study seemed to document the beginning of CLG, with lung compliance being the limiting factor of CLG at 5 months.Conclusion. There was CLG in both the reimplanted lobe and the contralateral lung, but compliance was still reduced. CLG was similar in both groups, but in the implanted lobe compliance was more prejudiced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito do laser de baixa intensidade sobre a contração da pseudocápsula que ocorre ao redor de implantes de silicone. MÉTODOS: 60 ratos machos divididos em dois grupos receberam implante de silicone. Grupo I: implante no subcutâneo da região dorsal, sem tratamento após a cirurgia; Grupo II: animais receberam sete sessões de irradiação com laser de baixa intensidade após o implante. Trinta, 60 e 180 dias após a cirurgia, foi feita a tonometria dos implantes, em seguida, os animais foram sacrificados, removendo-se o material de estudo que foi preparado para exame histológico, avaliando-se morfometricamente a espessura da pseudocápsula e a reação inflamatória. A análise estatistica pela técnica da Análise de Variância e Teste de Tukey (P<0.0 5). RESULTADOS: Pressões significativamente menores foram encontradas nos animais do grupo Grupo II. O estudo histológico não mostrou diferença significativa entre os grupos, destacando-se apenas maior quantidade de vasos intumescidos no Grupo II. A espessura da pseudocápsula foi menor no Grupo II. CONCLUSÃO: O laser de baixa intensidade altera o processo de reparação tecidual ao redor dos implantes, sugerindo que o mesmo possa ser útil para a modelação das contraturas que se estabelecem ao redor dos implantes de silicone.