956 resultados para MODIFIED HODGE TEST


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electrochemical SO2 sensor worked at the fixed potential and prepared with Nafion membrane as the solid electrolyte was studied. It v as observed that after Nafion membrane, was treated with H2SO4, the water-preserving ability of the membrane was increased. In turn, the performance of the sensor became stable. After lifetime test for 4 months, the performance of the sensor deceased slightly, Thus this kind of sensor may become a gas sensor for the practical application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A bench scale reaction test for methane aromatization in the absence of an added oxidant was performed and its reaction result evaluated based on the carbon balance of the system. The result was compared with those obtained from the micro-reaction test to ensure the accuracy of the internal standard analyzing method employed in this paper. The catalytic performances of modified Mo/HZSM-5 catalysts were examined. It was found that pre-treatment by steam on HZSM-5 weakened the serious deposition of coke, and pre-impregnation of n-ethyl silicate on HZSM-5 could improve the conversion of CH4, but had little effect on coke formation. A low temperature activation procedure including pre-reduction of the catalyst with methane prevents the zeolite lattice from being seriously destroyed by high valence state Mo species when the Mo loading is high. It was suggested that Mo2C species detected by XRD spectra was the active phase for CH4 aromatization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thatcher, Rhys, et al., 'A modified TRIMP to quantify the in-season training load of team sport players', Journal of Sport Sciences, (2007) 25(6) pp.629-634 RAE2008

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The method described here cannot fully replace the analysis of large columns by small test columns (microcolumns). The procedure, however, is suitable for speeding up the determination of adsorption parameters of dye onto the adsorbent and for speeding up the initial screening of a large adsorbent collection that can be tedious if a several adsorbents and adsorption conditions must be tested. The performance of methylene blue (MB), a basic dye, Cibacron reactive black (RB) and Cibacron reactive yellow (RY) was predicted in this way and the influence of initial dye concentration and other adsorption conditions on the adsorption behaviour were demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses a number of checks that should be carried out to ensure that the kinetic and spectroscopic measurements made using a DRIFTS cell are meaningful. The observations reported here demonstrate how an appropriately modified commercial DRIFTS cell can provide pertinent kinetic information about both gaseous products and the related surface intermediates. The oxidation of CO with 02 was used as a test to assess the catalyst bed bypass by the reaction mixture. Full CO conversion was obtained after the light-off temperature in the case of the modified cell, contrary to the case of the original cell, for which 80% of the reaction mixture bypassed the catalyst bed. The water-gas shift reaction over a Pt/CeO2 catalyst was used as a model reaction to further characterize the behavior of the cell under reaction conditions. The catalyst bed was shown not to be a dead-zone and was purged in essentially the same time as that needed to purge the cell. The reaction chamber globally operated in a quasi plug-flow mode and the gas composition in the thin catalyst bed appears to be homogeneous when operated under differential conditions. The production of the gas-phase reaction product CO2 could be simultaneously followed both by mass spectrometry and DRIFTS, both techniques leading to identical results. Various IR bands integration methods were discussed to allow a precise and accurate determination of the surface concentration of adsorbates during isotopic exchange. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we extend the heterogeneous panel data stationarity test of Hadri [Econometrics Journal, Vol. 3 (2000) pp. 148–161] to the cases where breaks are taken into account. Four models with different patterns of breaks under the null hypothesis are specified. Two of the models have been already proposed by Carrion-i-Silvestre et al.[Econometrics Journal,Vol. 8 (2005) pp. 159–175]. The moments of the statistics corresponding to the four models are derived in closed form via characteristic functions.We also provide the exact moments of a modified statistic that do not asymptotically depend on the location of the break point under the null hypothesis. The cases where the break point is unknown are also considered. For the model with breaks in the level and no time trend and for the model with breaks in the level and in the time trend, Carrion-i-Silvestre et al. [Econometrics Journal, Vol. 8 (2005) pp. 159–175]showed that the number of breaks and their positions may be allowed to differ acrossindividuals for cases with known and unknown breaks. Their results can easily be extended to the proposed modified statistic. The asymptotic distributions of all the statistics proposed are derived under the null hypothesis and are shown to be normally distributed. We show by simulations that our suggested tests have in general good performance in finite samples except the modified test. In an empirical application to the consumer prices of 22 OECD countries during the period from 1953 to 2003, we found evidence of stationarity once a structural break and cross-sectional dependence are accommodated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A set of cylindrical porous titanium test samples were produced using the three-dimensional printing and sintering method with samples sintered at 900 °C, 1000 °C, 1100 °C, 1200 °C or 1300 °C. Following compression testing, it was apparent that the stress-strain curves were similar in shape to the curves that represent cellular solids. This is despite a relative density twice as high as what is considered the threshold for defining a cellular solid. As final sintering temperature increased, the compressive behaviour developed from being elastic-brittle to elastic-plastic and while Young's modulus remained fairly constant in the region of 1.5 GPa, there was a corresponding increase in 0.2% proof stress of approximately 40-80 MPa. The cellular solid model consists of two equations that predict Young's modulus and yield or proof stress. By fitting to experimental data and consideration of porous morphology, appropriate changes to the geometry constants allow modification of the current models to predict with better accuracy the behaviour of porous materials with higher relative densities (lower porosity).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Lung clearance index (LCI) derived from sulfur hexafluoride (SF6) multiple breath washout (MBW) is a sensitive measure of lung disease in people with cystic fibrosis (CF). However, it can be time-consuming, limiting its use clinically. Aim: To compare the repeatability, sensitivity and test duration of LCI derived from washout to 1/30th (LCI1/30), 1/20th (LCI1/20) and 1/10th (LCI1/10) to ‘standard’ LCI derived from washout to 1/40th initial concentration (LCI1/40). Methods: Triplicate MBW test results from 30 clinically stable people with CF and 30 healthy controls were analysed retrospectively. MBW tests were performed using 0.2% SF6 and a modified Innocor device. All LCI end points were calculated using SimpleWashout software. Repeatability was assessed using coefficient of variation (CV%). The proportion of people with CF with and without abnormal LCI and forced expiratory volume in 1 s (FEV1) % predicted was compared. Receiver operating characteristic (ROC) curve statistics were calculated. Test duration of all LCI end points was compared using paired t tests. Results: In people with CF, LCI1/40 CV% (p=0.16), LCI1/30 CV%, (p=0.53), LCI1/20 CV% (p=0.14) and LCI1/10 CV% (p=0.25) was not significantly different to controls. The sensitivity of LCI1/40, LCI1/30 and LCI1/20 to the presence of CF was equal (67%). The sensitivity of LCI1/10 and FEV1% predicted was lower (53% and 47% respectively). Area under the ROC curve (95% CI) for LCI1/40, LCI1/30, LCI1/20, LCI1/10 and FEV1% predicted was 0.89 (0.80 to 0.97), 0.87 (0.77 to 0.96), 0.87 (0.78 to 0.96), 0.83 (0.72 to 0.94) and 0.73 (0.60 to 0.86), respectively. Test duration of LCI1/30, LCI1/20 and LCI1/10 was significantly shorter compared with the test duration of LCI1/40 in people with CF (p<0.0001) equating to a 5%, 9% and 15% time saving, respectively. Conclusions: In this study, LCI1/20 was a repeatable and sensitive measure with equal diagnostic performance to LCI1/40. LCI1/20 was shorter, potentially offering a more feasible research and clinical measure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Primary angle-closure glaucoma (PACG) is a major cause of visual morbidity in East Asia. Dark-room provocative test (DRPT) has been used to determine which narrow angles have the risk to develop angle closure. However, the accuracy of DRPT might be altered because that after emerging from the dark room, the configuration of the angle is affected by the light of the slit-lamp and the appositionally closed angle reopens. The aim of this study was to examine the pupillary diameter in different light conditions and use it as a parameter to assess the accuracy of dark-room provocative test. METHODS: Patients with suspected primary angle-closure glaucoma undergoing DRPT were recruited. The anterior chamber angle was examined by anterior segment optical coherence tomography under the following conditions: (1) in standard room illumination; (2) after short-term dark-adaptation and (3) after DRPT. Mean values of pupil size and numbers of appositionally closed angle under different conditions were compared. RESULTS: A total of 47 eyes of 47 patients were analyzed. The pupil size after DRPT was smaller than that after short-term dark-adaptation (P < 0.001) and smaller than that in standard room illumination (P = 0.026). The numbers of appositionally closed angles after short-term dark-adaptation were significantly larger than those after DRPT (P < 0.001). There was no significant difference between the numbers of appositionally closed angles in standard room illumination and after DRPT (P = 0.157). CONCLUSIONS: Constriction of pupil size immediately after prolonged dark room provocative test may lead to change in the angle configuration, which may lead to false negative results. We suggest a modified protocol of recording intraocular pressure immediately after DRPT and performing gonioscopy following short-term dark adaptation to improve the accuracy of angle closure assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de mestrado em Química Tecnológica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2016

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A modified chlorophyll fluorescence technique was evaluated as a rapid diagnostic test of the susceptibility of wheat cultivars to chlorotoluron. Two winter wheat cultivars (Maris Huntsman and Mercia) exhibited differential response to the herbicide. All of the parameters of chlorophyll fluorescence examined were strongly influenced by herbicide concentration. Additionally, the procedure adopted here for the examination of winter wheat cultivar sensitivity to herbicide indicated that the area above the fluorescence induction curve and the ratio F-V/F-M are appropriate chlorophyll fluorescence parameters for detection of differential herbicide response between wheat cultivars. The potential use of this technique as an alternative to traditional methods of screening new winter wheat cultivars for their response to photosynthetic inhibitor herbicide is demonstrated here.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional seemingly unrelated estimation of the almost ideal demand system is shown to lead to small sample bias and distortions in the size of a Wald test for symmetry and homogeneity when the data are co-integrated. A fully modified estimator is developed in an attempt to remedy these problems. It is shown that this estimator reduces the small sample bias but fails to eliminate the size distortion.. Bootstrapping is shown to be ineffective as a method of removing small sample bias in both the conventional and fully modified estimators. Bootstrapping is effective, however, as a method of removing. size distortion and performs equally well in this respect with both estimators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The International Citicoline Trial in acUte Stroke is a sequential phase III study of the use of the drug citicoline in the treatment of acute ischaemic stroke, which was initiated in 2006 in 56 treatment centres. The primary objective of the trial is to demonstrate improved recovery of patients randomized to citicoline relative to those randomized to placebo after 12 weeks of follow-up. The primary analysis will take the form of a global test combining the dichotomized results of assessments on three well-established scales: the Barthel Index, the modified Rankin scale and the National Institutes of Health Stroke Scale. This approach was previously used in the analysis of the influential National Institute of Neurological Disorders and Stroke trial of recombinant tissue plasminogen activator in stroke. The purpose of this paper is to describe how this trial was designed, and in particular how the simultaneous objectives of taking into account three assessment scales, performing a series of interim analyses and conducting treatment allocation and adjusting the analyses to account for prognostic factors, including more than 50 treatment centres, were addressed. Copyright (C) 2008 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A modified chlorophyll fluorescence technique was evaluated as a rapid diagnostic test of the susceptibility of wheat cultivars to chlorotoluron. Two winter wheat cultivars (Maris Huntsman and Mercia) exhibited differential response to the herbicide. All of the parameters of chlorophyll fluorescence examined were strongly influenced by herbicide concentration. Additionally, the procedure adopted here for the examination of winter wheat cultivar sensitivity to herbicide indicated that the area above the fluorescence induction curve and the ratio F-V/F-M are appropriate chlorophyll fluorescence parameters for detection of differential herbicide response between wheat cultivars. The potential use of this technique as an alternative to traditional methods of screening new winter wheat cultivars for their response to photosynthetic inhibitor herbicide is demonstrated here.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Performance analysis has been used for many applications including providing feedback to coaches and players, media applications, scoring of sports performance and scientific research into sports performance. The current study has used performance analysis to generate knowledge relating to the demands of netball competition which has been used in the development of a Netball Specific Fitness Test (NSFT). A modified version of the Bloomfield movement classification was used to provide a detailed analysis of player movement during netball competition. This was considered during a needs analysis when proposing the structure of the NSFT. A series of pilot versions were tested during an evolutionary prototyping process that resulted in the final version of the NSFT, which was found to be representative of movement in netball competition and it distinguished between recreational club players and players of university first team level or above. The test is incremental and involves forward, backward and sideways movement, jumping, lunging, turning and choice reaction.