952 resultados para M2-m3 Loop
Resumo:
Motivated by the dark matter and the baryon asymmetry problems, we analyze a complex singlet extension of the Standard Model with a Z(2) symmetry (which provides a dark matter candidate). After a detailed two-loop calculation of the renormalization group equations for the new scalar sector, we study the radiative stability of the model up to a high energy scale (with the constraint that the 126 GeV Higgs boson found at the LHC is in the spectrum) and find it requires the existence of a new scalar state mixing with the Higgs with a mass larger than 140 GeV. This bound is not very sensitive to the cutoff scale as long as the latter is larger than 10(10) GeV. We then include all experimental and observational constraints/measurements from collider data, from dark matter direct detection experiments, and from the Planck satellite and in addition force stability at least up to the grand unified theory scale, to find that the lower bound is raised to about 170 GeV, while the dark matter particle must be heavier than about 50 GeV.
Resumo:
Nesta dissertação pretendeu-se estudar a viabilidade do uso de eletrodiálise com membranas bipolares (BM) na recuperação de ácido clorídrico e de hidróxido de sódio a partir de um efluente industrial que contém 1.4 mol/L de cloreto de sódio. Estas membranas mostraram ser uma ferramenta eficiente para a produção de ácidos e bases a partir do respetivo sal. Foi feita uma seleção de diferentes membranas bipolares (Neosepta, Fumatech e PCA) e aniónicas (PC-SA e PC-ACID 60) na tentativa de encontrar a combinação mais adequada para o tratamento do efluente. Dependendo do critério, o melhor arranjo de membranas é o uso de PC-ACID 60 (membrana aniónica), PC-SK (membrana catiónica) e membranas bipolares do tipo Neosepta para maior pureza dos produtos; membranas bipolares Fumatech para maior eficiência de dessalinização e membranas bipolares PCA para um maior grau de dessalinização. Tecnologicamente foi possível obter uma dessalinização de 99.8% em quatro horas de funcionamento em modo batch com recirculação de todas as correntes. Independentemente da combinação usada é recomendável que o processo seja parado quando a densidade de corrente deixa de ser máxima, 781 A/m2. Assim é possível evitar o aumento de impurezas nos produtos, contra difusão, descida instantânea do pH e uma dessalinização pouco eficiente. A nível piloto o principal fornecedor de membranas e unidade de tratamento “stack” é a marca alemã PCA. Sendo assim realizaram-se ensaios de repetibilidade, contra difusão, avaliação económica e upscaling utilizando as membranas bipolares PCA. A nível económico estudou-se o uso de dois tipos de unidades de tratamento; EDQ 380 e EDQ 1600, para diferentes níveis de dessalinização (50, 75 e 80%). Tendo em conta a otimização económica, é recomendável uma dessalinização máxima de 80%, uma vez que a eficiência de processo a este ponto é de 40%. A aplicação do método com a unidade EDQ 1600 para uma dessalinização de 50% é a mais vantajosa economicamente, com custos de 16 €/m3 de efluente tratado ou 0,78 €/kg Cl- removido. O número de unidades necessárias é 4 posicionados em série.
Resumo:
A presente dissertação tem como principal propósito avaliar o desempenho energético e a qualidade do ar interior do edifício principal do Parque Biológico de Vila Nova de Gaia (PBG). Para esse efeito, este estudo relaciona os termos definidos na legislação nacional em vigor até à presente data, e referentes a esta área de atuação, em particular, os presentes no SCE, RSECE, RCCTE e RSECE-QAI. Para avaliar o desempenho energético, procedeu-se numa primeira fase ao processo de auditoria no local e posteriormente à realização de uma simulação dinâmica detalhada, cuja modelação do edifício foi feita com recurso ao software DesignBuilder. Após a validação do modelo simulado, por verificação do desvio entre os consumos energéticos registados nas faturas e os calculados na simulação, igual a 5,97%, foi possível efetuar a desagregação dos consumos em percentagem pelos diferentes tipos de utilizações. Foi também possível determinar os IEE real e nominal, correspondendo a 29,9 e 41.3 kgep/m2.ano, respetivamente, constatando-se através dos mesmos que o edifício ficaria dispensado de implementar um plano de racionalização energética (PRE) e que a classe energética a atribuir é a C. Contudo, foram apresentadas algumas medidas de poupança de energia, de modo a melhorar a eficiência energética do edifício e reduzir a fatura associada. Destas destacam-se duas propostas, a primeira propõe a alteração do sistema de iluminação interior e exterior do edifício, conduzindo a uma redução no consumo de eletricidade de 47,5 MWh/ano, com um período de retorno de investimento de 3,5 anos. A segunda está relacionada com a alteração do sistema de produção de água quente para o aquecimento central, através do incremento de uma caldeira a lenha ao sistema atual, que prevê uma redução de 50 MWh no consumo de gás natural e um período de retorno de investimento de cerca de 4 anos. Na análise realizada à qualidade do ar interior (QAI), os parâmetros quantificados foram os exigidos legalmente, excetuando os microbiológicos. Deste modo, para os parâmetros físicos, temperatura e humidade relativa, obtiveram-se os resultados médios de 19,7ºC e 66,9%, respetivamente, ligeiramente abaixo do previsto na legislação (20,0ºC no período em que foi feita a medição, inverno). No que diz respeito aos parâmetros químicos, os valores médios registados para as concentrações de dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCHO), partículas em suspensão (PM10) e radão, foram iguais a 580 ppm, 0,2 ppm, 0,06 ppm, 0,01 ppm, 0,07 mg/m3 e 196 Bq/m3, respetivamente, verificando-se que estão abaixo dos valores máximos de referência presentes no regulamento (984 ppm, 10,7 ppm, 0,10 ppm, 0,08 ppm, 0,15 mg/m3 e 400 Bq/m3). No entanto, o parâmetro relativo aos compostos orgânicos voláteis (COV) teve um valor médio igual a 0,84 ppm, bastante acima do valor máximo de referência (0,26 ppm). Neste caso, terá que ser realizada uma nova série de medições utilizando meios cromatográficos, para avaliar qual(ais) são o(s) agente(s) poluidor(es), de modo a eliminar ou atenuar as fontes de emissão.
Resumo:
The loop-mediated isothermal amplification method (LAMP) is a recently developed molecular technique that amplifies nucleic acid under isothermal conditions. For malaria diagnosis, 150 blood samples from consecutive febrile malaria patients, and healthy subjects were screened in Thailand. Each sample was diagnosed by LAMP, microscopy and nested polymerase chain reaction (nPCR), using nPCR as the gold standard. Malaria LAMP was performed using Plasmodiumgenus and Plasmodium falciparum specific assays in parallel. For the genus Plasmodium, microscopy showed a sensitivity and specificity of 100%, while LAMP presented 99% of sensitivity and 93% of specificity. For P. falciparum, microscopy had a sensitivity of 95%, and LAMP of 90%, regarding the specificity; and microscopy presented 93% and LAMP 97% of specificity. The results of the genus-specific LAMP technique were highly consistent with those of nPCR and the sensitivity of P. falciparum detection was only marginally lower.
Resumo:
RESUMO: Introdução: A relação cinemática entre as articulações do CAO apresenta grande importância na função do MS, e é por isso cada vez mais investigada e descrita. O posicionamento da omoplata ganha um importante papel para compreender as DCAO. É indiscutível o importante papel da omoplata na dinâmica do MS, bem como o posicionamento escapular como parâmetro clínico de disfunção do CAO. Todos estes factores criam a necessidade de desenvolver instrumentos de avaliação da posição da articulação ET. A grande maioria dos testes de avaliação, restringem a sua avaliação às disfunções da articulação GU, não integrando uma avaliação mais dinâmica e interactiva que respeite os pressupostos teóricos inerentes ao REU. È importante também que os métodos de avaliação sejam de fácil aplicabilidade clínica e que avaliem fidedignamente e com validade os outcomes. Objectivos: Contribuir para o desenvolvimento de uma metodologia de avaliação da omoplata em diferentes amplitudes do MS, através do estudo da validade concorrente, da fidedignidade intra e inter-observador. Metodologia: A amostra foi constituída por 20 elementos seleccionados por conveniência, entre o corpo de discentes da ESS-IPS, sem história de disfunção do CAO. Foi realizada uma análise cinemática ao MS de cada sujeito, usando um aparelho de análise por varrimento electromagnético, o FOB. Em cada sujeito foram ainda medidas, as distâncias escapulares em estudo, usando a fita métrica. Cada método de medição foi constituído por dois momento (teste e reteste), em cada momento, as medidas eram recolhidas por dois investigadores distintos. Resultados e Discussão: Foram considerados como positivos os resultados que se apresentassem acima do limiar de 0,5, que classifica uma correlação como moderada a excelente. Os resultados da validade mostram que para o investigador 1 nas medidas M1e M2 apenas houve correlação com valores excelentes a moderados até aos 30º de elevação do MS. Já para M3 apenas aos 30º no plano da omoplata essa mesma correlação não tem valores próximos do cutpoint. Em M4 nenhum valor tem correlação significativa com os valores do FOB, chegando mesmo a haver correlação negativa para os 120º no plano da omoplata. Em M5 apenas os 0º mostram valores correlacionais excelentes a moderados. Para o investigador 2, em M1 e M2 á semelhança do investigador 1, só existem valores de correlação significativos até aos 30º de elevação do MS. Já para M3 todos os valores mostram excelente a moderada correlação á excepção dos 120º no plano frontal. Em M4 este investigador apresenta maus resultados. Já em M5 os valores de correlação são moderados aos 0º e aos 90º. No que diz respeitos aos resultados dos CCI intra-observador,podemos afirmar que foi em M5 que estes valores mais se aproximaram do cut point. M1 e M2 são as medidas onde se encontram resultados menos satisfatórios. É aos 60º que existem valores mais satisfatórios, seguidos pelos 0º e 30º, quando nos aproximamos de graus mais elevados, como 90º e 120º, estes valores tendem a baixar. Quanto á fidedignidade inter-observador para M1 apenas aos 90º e aos 120º houve valores de correlação abaixo do cutpoint. Em M2, só os 60º do plano sagital não teve valores acima do cutpoint, em M3 apenas os 30º plano sagital não obtiveram valores acima do cut-point, o mesmo acontece para M3 aos 30º plano da omoplata e em M5 aos 30º e 120º no plano frontal. Conclusão: Os resultados deste estudo indicam que a metodologia em causa apresenta elevado grau de fidedignidade inter-observador, já no que toca é fidedignidade intra-observador o grau de semelhança não é tão elevado. Também o erro associado á medida não ultrapassou 1,5cm, sendo considerado baixo. Na validade concorrente concluímos que é aos 0º que a metodologia se torna uma opção válida na aferição das distâncias medidas com uma boa a excelente concordância com o FOB. As medidas consideradas como opções válidas, nas diferentes amplitudes, podem funcionar como parâmetros clínicos de caracterização do posicionamento da omoplata, podendo vir a contribuir ainda para a caracterização da orientação da mesma.-------------------- ABSTRACT:Introduction: The kinematic relationship between the joints of the CAO has great importance in the function of MS, which is why more and more investigated and described. The positioning of the blade gets an important role in understanding the DCAO. There is no doubt the important role of the scapula in the dynamics of MS as well as the positioning of scapular dysfunction as a clinical parameter of the CAO. All these factors create the need to develop tools for evaluating the place of articulation ET. Most assessment tests, restrict its assessment to GU joint disorders, not incorporating a more dynamic and interactive way that respects the theoretical assumptions inherent in the REU. It is also important that the methods are easy to apply clinical and reliably to assess the validity and outcomes. Objectives: To contribute to the development of a methodology for evaluating the scapula in different ranges of MS, through the study of concurrent validity, reliability of intra-and inter-observer. Methodology: The sample consisted of 20 selected elements for convenience, between the body of students of IPS-ESS with no history of dysfunction of the CAO. We performed a kinematic analysis of each subject to MS, using a scanning device for electromagnetic analysis, the FOB. In each subject were also measured, the scapular distances under study, using tape measure. Each method of measuring the time consisted of two (test and retest), in each moment, the measures were collected by two different investigators. Results and Discussion: We considered as positive results that were above the threshold of 0.5, which ranks as a moderate to excellent correlation. The results show that the validity for the researcher in an action M1e M2 was only correlated with moderate to excellent values up to 30º of elevation of the MS. As for M3 only to 30º in the plane of the scapula has the same correlation values near the cutpoint. M4 has no value in correlation with the values of the FOB, and even negative correlation to 120 ° in the plane of the scapula. In M5 show only the values 0 ° correlational excellent to moderate. For investigator 2 in M1 and M2 will be like an investigator, there are only significant correlation values up to 30º of elevation of the MS. As for M3 all the values show excellent correlation to moderate with the exception of 120 ° in the frontal plane. In this researcher M4 has bad results. M5 already in the correlation values are moderate to 0º and 90 º. Regarding the results of ICC intra-observer, we can say that M5 was that these values come closest to the cut point. M1 and M2 are measures which are less than satisfactory results. At 60 ° there are more satisfactory values, followed by 0º and 30º, when we approached the highest levels, such as 90 ° and 120 °, these values tend to decrease. The inter-observer reliability for M1 only to 90 º and 120 ºcorrelation values were below the cutpoint. In M2, only 60 of the sagital plane did not have values above the cutpoint in M3 only 30º sagital plane did not obtain values above the cut-point, the same goes for M3 at 30 ° plane of the scapula and M5 at 30 º and 120 º in frontal plane. Conclusion: The results of this study indicate that the methodology in question has a high degree of inter-observer reliability, as far as intra-observer reliability is the degree of similarity is not as high. Also the error of measure did not exceed 1.5 cm, and is considered low. In concurrent validity conclude that it is at 0 ° the methodology becomes a valid option for the measurement of distances measured with a good to excellent agreement with the FOB. The measures considered as valid options in different amplitudes, can function as clinical parameters to characterize the positioning of the shoulder blade and could further contribute to the characterization of the orientation of the same.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Avaliar a microbiota intestinal de indivíduos que sofreram acidente ocupacional com materiais biológicos e receberam anti-retrovirais foi o objetivo deste estudo. O grupo de estudo constou de 23 indivíduos com idade entre 18-45 anos, sendo 13 doadores de sangue e 10 que sofreram acidente ocupacional. Foram avaliados a microbiota intestinal, antropometria e exames laboratoriais pré, pós e 30 dias após o término da medicação. Zidovudina mais lamivudina foi utilizada em 70% dos indivíduos associado ao nelfinavir, 20% ao efavirenz e 10% ao ritonavir. As alterações nutricionais e dietéticas-laboratoriais e de microbiota intestinal foram analisadas em três momentos. M1: até dois dias do início da profilaxia; M2: no último dia da profilaxia e M3: 30 dias após o término da profilaxia. Náuseas, vômitos e diarréia estiveram presentes em 50% no segundo momento do estudo. Sobrepeso em 70%, desnutrição e eutrofia em 10%, dos indivíduos, não se modificaram durante o estudo. Transaminases, triglicérides, LDL-colesterol se elevaram no segundo momento e normalizaram 30 dias após término da medicação. Houve redução significativa dos Lactobacillus, Bifidobacterium e Bacteróides nos três momentos. Uso de anti-retrovirais provocou impacto significativo na microbiota intestinal dos indivíduos, sem recuperação em 30 dias.
Resumo:
O sector automóvel tem um papel importante na sociedade actual, sendo um dos motores do crescimento económico de vários países. Mas aliado ao seu desenvolvimento, estão problemas ambientais com grande relevância actual, como as emissões de poluentes atmosféricos pelo uso dos veículos. Contudo, não é apenas a fase de uso do automóvel que está ligada a impactos ambientais, sendo importante avaliar as restantes fases do ciclo de vida. Para o panorama nacional, os estudos neste sector não se encontram muito desenvolvidos. O objectivo da presente dissertação passa pela avaliação do desempenho ambiental do sector dos veículos ligeiros de passageiros em Portugal, estabelecendo uma comparação entre as várias tecnologias automóveis que o compõem, mediante o uso da metodologia de análise de ciclo de vida (ACV). O desempenho ambiental dos veículos foi traduzido segundo a metodologia de avaliação de impactes EcoBlok. Para o ano de 2013 um veículo médio português consumiu 11,8 m3 de água, utilizou 2,8 t eq. de recursos, ocupou 54 m2 eq. de solo, emitiu 3,4 t de CO2 eq e 150 kg de NOx eq para a atmosfera, emitiu 600 kg de N eq. para a água e o solo, e gerou 3,5 mg de dioxinas e furanos. Com a introdução de mais veículos eléctricos a baterias na frota perspectivam-se reduções ao nível do consumo de recursos, de emissões de gases com efeito de estufa e de poluição do ar. No entanto, para o consumo de água, uso do solo, emissões para o solo e água e formação de dioxinas e furanos prevêem-se aumentos. A fase de manufactura, que é diluída ao longo da vida útil do veículo, é responsável por mais de metade dos impactos ambientais gerados ao nível do uso do solo, da poluição da água e do solo e da formação de dioxinas e furanos. Por sua vez, a fase de uso do veículo é determinante nos impactes sobre a poluição do ar e emissões de gases com efeito de estufa, sendo responsável por mais de 80% dos resultados. As conclusões retiradas com a realização desta dissertação são úteis, na medida em que podem auxiliar o desenvolvimento de políticas de incentivos para a mudança de comportamentos da população face aos transportes. Por outro lado, permite perceber que as tecnologias menos poluentes têm ainda um longo caminho a percorrer para que se tornem, globalmente, a melhor alternativa de mobilidade face às tecnologias convencionais.
Resumo:
O presente trabalho visou o estudo comparativo de 6 métodos propostos para a determinação da densidade básica em madeira e ainda, o efeito de 3 dimensões dos corpos de prova nos métodos. Para tal empregou-se distintamente cerne e alburno da espécie Hymenaea cobaril L. (jatobá) em corpos de provas nas dimensões 2 x 2 x 1 com (D1), 2 x 2 x 3 com (D2) e 2 x 2 x 5 cm (D3). Os métodos analisados foram: a) método de imersão-baseado na variação do peso do líquido (M1); b) o método de medição direta do volume por paquímetro (M2); c) método de imersão-baseado na variação do peso da amostra (M3); d) método de medição direta do volume por cilindro graduado-corpo de prova imerso em areia (M4); e) método de máximo teor de umidade (M5) e f) método de medição direta do volume for cilindro graduado-corpo de prova imperso em água (M6). Os métodos M1, M3 e M5 foram os mais precisos, de melhores repetibilidades, iguais estatisticamente e que não sofreram influência das dimensões influenciaram significativamente os métodos M2, M4 e M6, que foram os menos precisos.
Resumo:
A distribuição da biomassa e da área absorvente do sistema radicular da pupunheira (Bactris gasipaes)foram estudadas num latossolo amarelo, textura argilosa, perto de Manaus, Amazonas, Brasil. Aproximadamente 80% da biomassa se encontrava no horizonte Ap, da qual 90% se encontrava dentro da área de projeção da copa. A biomassa total estimada pesou 72 kg, excluindo-se a massa logo abaixo do estipe. A área superficial das raízes aumentou significativamente conforme se afastava do estipe, devido a proporção cada vez maior de raízes terciárias e quartenárias, embora sua abundância por m3 diminuiu de forma similar à biomassa. A área superficial total estimada chegou a 545 m2, da qual se supõe que 50% é ativa na absorção de nutrientes. Supõe-se ainda que existam raízes absorventes até 8-9 m do estipe das plantas. Recomenda-se que a adubação seja feita dentro e logo fora da projeção da copa.
Resumo:
Mesenchymal stem cells (MSCs) are considered to be â â immunologically privileged.â â In a previous work when human adipose tissue-derived stem cells (hASCs) subcutaneously implanted in mice we did not identify an adverse host response1. Recently, it was shown that tissue regeneration could benefit from the polarization of M2 macrophages subpopulations 2. In this study we hypothesised that undifferentiated hASCs and derived osteoblasts and chondrocytes are able to switch murine bone marrow-derived macrophages (mBMMÃ s) into M2 phenotype, aiding tissue regeneration. Murine BMMÃ s were plated in direct contact with undifferentiated and osteo or chondro-differentiated hASCs for 4 h, 10 h, 24 h and 72 h. The cytokine profile was analysed by qRT-PCR and the surface markers were detected by flow cytometry. The direct interaction of both cell types was observed by time lapse microscopy. The results showed that mBMMÃ s polarized after contacting tissue culture polystyrene. This M2 phenotype was maintained along the experiment in direct contact with both undifferentiated and osteo or chondro-differentiated hASCs. This was confirmed by the expression of IL-1, IL-10, IL-4, TNF-a and IFN-g (genetic profile) and surface markers (CD206 + + , CD336 + + , MHC II + and CD86 + + ) detection. These data suggest the potential of hASCs in contemporary xenogenic tissue engineering and regenerative medicine strategies, as well as host immune system modulation in autoimmune diseases.
Resumo:
Esta pesquisa foi realizada na Floresta Nacional do Tapajós, Pará, e foram avaliados os custos e rendimentos de quatro diferentes Métodos de corte de cipós na condução do manejo florestal, visando à produção de madeira em toras. Cada método foi conduzido numa área de 96 ha e a metodologia consistiu em cortar os cipós em torno de todas as árvores comerciais e potencialmente comerciais (Método M1-Individual), apenas na área de ocorrência de árvores comerciais e potencialmente comerciais (Método M2-Zoneado), em torno de todas as árvores comerciais e potencialmente comerciais e na direção de queda (Método M3-direção de queda) e apenas em torno das árvores comerciais destinadas à primeira colheita (Método M4). Em todas as variáveis analisadas os métodos utilizados diferiram estatisticamente. O método M4, com o menor custo (6,35 US$) e maior rendimento (2,07 ha/hora) é considerado o melhor desta pesquisa. Neste método, a população de cipós é parcialmente preservada, mantendo, assim, sua importante função ecológica na floresta.
Resumo:
OBJECTIVE: To evaluate the effects of diet and medication, either isolated or associated, on serum levels of uric acid in patients with hyperuricemia. METHODS: We studied patients from the Hypertension Unit of the University of Goias who had hyperuricemia (men > or = 8.5mg/dL and women > or = 7.5mg/dL). We divided the patients into three groups: G1 (low purine diet), G2 (low purine diet + medication), and G3 (medication only). Patients received allopurinol, 150mg/day titrated up to 300mg/dL when necessary. Patients were evaluated with regards to their lifestyles (diet, smoking, physical, activity, alcohol consumption), uric acid, blood pressure, use of medication, body mass index, cholesterol, and triglyceride. Follow-up took place in weeks 0 (M1), 6 (M2), 12 (M3) during the intervention and in week 36(M4) after the study was completed. RESULTS: Fifty-five patients participated in the study, 31 women, mean age 54.4±10.6 years, body mass index 28.6±3.9kg/m². A similar reduction (p<0.001) in uric acid levels occurred in the three intervention groups. In week 36 (M4), after 24 weeks without intervention, a tendency toward elevation of uricemia was noted in G2 and G3, and a continuous drop in uricemia was noted in G1. No significant modifications were observed in the other variables analyzed. CONCLUSION: Considering the cost x benefit relationship, a diet low in purine should be the 1st therapeutic option for controlling hyperuricemia in patients with similar characteristic to the ones presented in this study.
Resumo:
OBJETIVO: Avaliar os efeitos da clonidina sobre a freqüência cardíaca (FC), pressão arterial (PA) e sedação de pacientes submetidos à cineangiocoronariografia. MÉTODOS: Um ensaio clínico prospectivo, duplo cego, randomizado, controlado, foi realizado com 62 pacientes submetidos a cineangiocoronariografias eletivas, divididos em dois grupos: grupo clonidina que utilizou 0,8 µg/kg desta droga, e o grupo controle que utilizou solução fisiológica a 0,9%. A sedação foi avaliada com base na escala de Ramsay e o consumo de meperidina 0,04 mg/kg que foi utilizada nos pacientes que apresentaram agitação ou ansiedade durante o procedimento. A PA invasiva, a FC e o escore de sedação, de acordo com a escala de Ramsay, foram analisados a cada 5 minutos e quatro diferentes momentos foram considerados para avaliação: M1- inicio do exame; M2- 5 minutos após o início do exame; M3- mediana do tempo do exame e M4 - final do exame. RESULTADOS: O grupo clonidina apresentou maior estabilidade da PA e FC e eficácia na sedação, enquanto o grupo controle apresentou um maior consumo de meperidina (p<0,05). Na análise estatística, para inferência das variáveis contínuas foi utilizado o teste T ou Mann-Whitney e chi2 ou Teste Exato de Fisher para as variáveis categóricas. CONCLUSÃO: Este trabalho mostrou que, nos pacientes submetidos à cineangiocoronariografia, a utilização da clonidina foi eficaz tanto no controle da PA e FC quanto em proporcionar uma sedação consciente.
Resumo:
FUNDAMENTO: As cardiopatias são doenças de alta prevalência, sendo a cardite reumática uma doença de grande relevância em países em desenvolvimento. As alterações em câmaras cardíacas esquerdas se associam à disfunção endotelial, com aumento dos níveis de endotelina-1 (ET-1) e consequências sobre a circulação pulmonar, muitas vezes determinando a hipertensão pulmonar (HP). No entanto, a presença de ET-1 e seus receptores na própria valva mitral, promovendo alterações vasculares pulmonares e aumentando a deformação valvar reumática, ainda é um assunto não abordado na literatura. OBJETIVO: Determinar, mediante técnicas moleculares, a expressão dos genes da endotelina e dos seus receptores em valvas mitrais reumáticas. MÉTODOS: 27 pacientes submetidos à troca valvar mitral tiveram seu tecido valvar analisado, a fim de determinar a presença de genes de ET-1 e seus receptores A e B. Foram feitas análises histológica e molecular das valvas (divididas em fragmentos M1, M2 e M3) e colhidos dados clínicos e epidemiológicos dos pacientes. Foram divididos em três grupos: valvopatia mitral, mitroaórtica e pacientes reoperados. RESULTADOS: O estudo mostrou a manifestação do gene da ET-1 em 40,7% dos espécimes e de seu receptor A em todas as amostras, com manifestação minoritária do gene do receptor B (22,2%). CONCLUSÃO: Todos os pacientes expressaram a presença do gene do receptor A. Não houve diferença estatística quanto à gravidade da doença, expressa em classe funcional, e aos subgrupos estudados (valvopatas mitrais, mitroaórticos e pacientes reoperados), ou quanto à expressão dos genes da ET-1 e seus receptores entre os subgrupos estudados (valvopatas mitrais, mitroaórticos e pacientes reoperados).