965 resultados para LED light calibration system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The periodic spectroscopic events in eta Carinae are now well established and occur near the periastron passage of two massive stars in a very eccentric orbit. Several mechanisms have been proposed to explain the variations of different spectral features, such as an eclipse by the wind-wind collision (WWC) boundary, a shell ejection from the primary star or accretion of its wind onto the secondary. All of them have problems explaining all the observed phenomena. To better understand the nature of the cyclic events, we performed a dense monitoring of eta Carinae with five Southern telescopes during the 2009 low-excitation event, resulting in a set of data of unprecedented quality and sampling. The intrinsic luminosity of the He II lambda 4686 emission line (L similar to 310 L-circle dot) just before periastron reveals the presence of a very luminous transient source of extreme UV radiation emitted in the WWC region. Clumps in the primary's wind probably explain the flare-like behavior of both the X-ray and He II lambda 4686 light curves. After a short-lived minimum, He II lambda 4686 emission rises again to a new maximum, when X-rays are still absent or very weak. We interpret this as a collapse of the WWC onto the "surface" of the secondary star, switching off the hard X-ray source and diminishing the WWC shock cone. The recovery from this state is controlled by the momentum balance between the secondary's wind and the clumps in the primary's wind.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aiming to compare the effect of different light sources for dental bleaching on vascular permeability of dental pulps, forty-eight incisors were used. The bleaching agent (35% hydrogen peroxide) was activated by halogen light; LED (Light Emitting Diode) or LED, followed by laser phototherapy (LPT) (lambda = 780 nm; 3 J/cm(2)). After the bleaching procedures, the animals received an intra-arterial dye injection and one hour later were sacrificed. The teeth were diaphanized and photographed. The amount of blue stain content of each dental pulp was quantified using a computer imaging program. The data was statistically compared (p <= 0.05). The results showed a significant higher (p <= 0.01) dye content in the groups bleached with halogen light, compared with the control, LED and LED plus LPT groups. Thus, tooth bleaching activated by LED or LED plus LPT induces lesser resulted in increased vascular permeability than halogen light.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A complete census of planetary systems around a volume-limited sample of solar-type stars (FGK dwarfs) in the Solar neighborhood (d a parts per thousand currency signaEuro parts per thousand 15 pc) with uniform sensitivity down to Earth-mass planets within their Habitable Zones out to several AUs would be a major milestone in extrasolar planets astrophysics. This fundamental goal can be achieved with a mission concept such as NEAT-the Nearby Earth Astrometric Telescope. NEAT is designed to carry out space-borne extremely-high-precision astrometric measurements at the 0.05 mu as (1 sigma) accuracy level, sufficient to detect dynamical effects due to orbiting planets of mass even lower than Earth's around the nearest stars. Such a survey mission would provide the actual planetary masses and the full orbital geometry for all the components of the detected planetary systems down to the Earth-mass limit. The NEAT performance limits can be achieved by carrying out differential astrometry between the targets and a set of suitable reference stars in the field. The NEAT instrument design consists of an off-axis parabola single-mirror telescope (D = 1 m), a detector with a large field of view located 40 m away from the telescope and made of 8 small movable CCDs located around a fixed central CCD, and an interferometric calibration system monitoring dynamical Young's fringes originating from metrology fibers located at the primary mirror. The mission profile is driven by the fact that the two main modules of the payload, the telescope and the focal plane, must be located 40 m away leading to the choice of a formation flying option as the reference mission, and of a deployable boom option as an alternative choice. The proposed mission architecture relies on the use of two satellites, of about 700 kg each, operating at L2 for 5 years, flying in formation and offering a capability of more than 20,000 reconfigurations. The two satellites will be launched in a stacked configuration using a Soyuz ST launch vehicle. The NEAT primary science program will encompass an astrometric survey of our 200 closest F-, G- and K-type stellar neighbors, with an average of 50 visits each distributed over the nominal mission duration. The main survey operation will use approximately 70% of the mission lifetime. The remaining 30% of NEAT observing time might be allocated, for example, to improve the characterization of the architecture of selected planetary systems around nearby targets of specific interest (low-mass stars, young stars, etc.) discovered by Gaia, ground-based high-precision radial-velocity surveys, and other programs. With its exquisite, surgical astrometric precision, NEAT holds the promise to provide the first thorough census for Earth-mass planets around stars in the immediate vicinity of our Sun.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of photodynamic therapy (PDT) for the disinfection of complete dentures. Biofilm samples were collected from dentures of 60 denture users who were randomly divided into four experimental groups (n = 15 each): subjects whose maxillary dentures were sprayed with 50 and 100 mg/l of PhotogemA (R) suspension (groups P50S and P100S) and patients whose maxillary dentures were treated with 50 and 100 mg/l of PhotogemA (R) gel (groups P50G and P100G). Dentures with photosensitizers were left in the dark for 30 min (pre-irradiation time) and then irradiated with blue LED light at 37.5 J/cm(2) (26 min). Denture samples were taken with sterile cotton swab before (left side surfaces) and after (right side surfaces) PDT. All microbial material was diluted and plated on selective media for Candida spp., Staphylococcus mutans spp., streptococci and a non-selective media. After incubation (48 h/37A degrees C), the number of colony-forming units (cfu/ml) was counted. Microorganisms grown on selective media were identified using biochemical methods before and after PDT. The data were submitted to McNemar and Kruskal-Wallis tests (alpha = 0.05). No growth after PDT was observed in 60, 53, 47, and 40% of dentures from P100G, P50G, P100S, and P50S groups, respectively. When evidence of microorganisms' growth was observed, PDT regimens eliminated over 90% of microorganisms on dentures. This clinical study showed that PDT was effective for disinfecting dentures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aiming to compare the effect of different light sources for dental bleaching on vascular permeability of dental pulps, forty-eight incisors were used. The bleaching agent (35 % hydrogen peroxide) was activated by halogen light; LED (Light Emitting Diode) or LED, followed by laser phototherapy (LPT) (λ = 780 nm; 3 J/cm²). After the bleaching procedures, the animals received an intra-arterial dye injection and one hour later were sacrificed. The teeth were diaphanized and photographed. The amount of blue stain content of each dental pulp was quantified using a computer imaging program. The data was statistically compared (p < 0.05). The results showed a significant higher (p < 0.01) dye content in the groups bleached with halogen light, compared with the control, LED and LED plus LPT groups. Thus, tooth bleaching activated by LED or LED plus LPT induces lesser resulted in increased vascular permeability than halogen light.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The patterning of photoactive purple membrane (PM) films onto electronic substrates to create a biologically based light detection device was investigated. This research is part of a larger collaborative effort to develop a miniaturized toxin detection platform. This platform will utilize PM films containing the photoactive protein bacteriorhodopsin to convert light energy to electrical energy. Following an effort to pattern PM films using focused ion beam machining, the photolithography based bacteriorhodopsin patterning technique (PBBPT) was developed. This technique utilizes conventional photolithography techniques to pattern oriented PM films onto flat substrates. After the basic patterning process was developed, studies were conducted that confirmed the photoelectric functionality of the PM films after patterning. Several process variables were studied and optimized in order to increase the pattern quality of the PM films. Optical microscopy, scanning electron microscopy, and interferometric microscopy were used to evaluate the PM films produced by the patterning technique. Patterned PM films with lateral dimensions of 15 μm have been demonstrated using this technique. Unlike other patterning techniques, the PBBPT uses standard photolithographic processes that make its integration with conventional semiconductor fabrication feasible. The final effort of this research involved integrating PM films patterned using the PBBPT with PMOS transistors. An indirect integration of PM films with PMOS transistors was successfully demonstrated. This indirect integration used the voltage produced by a patterned PM film under light exposure to modulate the gate of a PMOS transistor, activating the transistor. Following this success, a study investigating how this PM based light detection system responded to variations in light intensity supplied to the PM film. This work provides a successful proof of concept for a portion of the toxin detection platform currently under development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nitric oxide has the potential to greatly improve intravascular measurements by locally inhibiting thrombus formation and dilating blood vessels. pH, the partial pressure of oxygen, and the partial pressure of carbon dioxide are three arterial blood parameters that are of interest to clinicians in the intensive care unit that can benefit from an intravascular sensor. This work explores fabrication of absorbance and fluorescence based pH sensing chemistry, the sensing chemistries' compatibility with nitric oxide, and a controllable nitric oxide releasing polymer. The pH sensing chemistries utilized various substrates, dyes, and methods of immobilization. Absorbance sensing chemistries used sol-gels, fumed silica particles, mesoporous silicon oxide, bromocresol purple, phenol red, bromocresol green, physical entrapment, molecular interactions, and covalent linking. Covalently linking the dyes to fumed silica particles and mesoporous silicon oxide eliminated leaching in the absorbance sensing chemistries. The structures of the absorbance dyes investigated were similar and bromocresol green in a sol-gel was tested for compatibility with nitric oxide. Nitric oxide did not interfere with the use of bromocresol green in a pH sensor. Investigated fluorescence sensing chemistries utilized silica optical fibers, poly(allylamine) hydrogel, SNARF-1, molecular interactions, and covalent linking. SNARF-1 covalently linked to a modified poly(allylamine) hydrogel was tested in the presence of nitric oxide and showed no interference from the nitric oxide. Nitric oxide release was controlled through the modulation of a light source that cleaved the bond between the nitric oxide and a sulfur atom in the donor. The nitric oxide donor in this work is S-nitroso-N-acetyl-D-penicillamine which was covalently linked to a silicone rubber made from polydimethylsiloxane. It is shown that the surface flux of nitric oxide released from the polymer films can be increased and decreased by increasing and decreasing the output power of the LED light source. In summary, an optical pH sensing chemistry was developed that eliminated the chronic problem of leaching of the indicator dye and showed no reactivity to nitric oxide released, thereby facilitating the development of a functional, reliable intravascular sensor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on three identical maxillary acrylic resin models, with a palatally displaced right lateral incisor. The transfer trays for the indirect bonding of the lingual brackets were constructed in certified laboratories. Each model was mounted on the orthodontic measurement and simulation system and ten 0.013 inch CuNiTi wires were used for each bracket type. The wire was ligated with elastomerics and each measurement was repeated once after re-ligation. The labiopalatal forces and the moments in the sagittal plane were recorded on the right lateral incisor. One-way analysis of variance and post hoc Scheffe pairwise comparisons were used to assess the effect on bracket type on the generated forces and moments. The magnitude of forces ranged from 1.62, 1.27, and 1.81 N for the STb, conventional, and Incognito brackets, respectively; the corresponding moments were 2.01, 1.45, and 2.19 N mm, respectively. Bracket type was a significant predictor of the generated forces (P < 0.001) and moments (P < 0.001). The produced forces were different among all three bracket types, whereas the generated moments differed between conventional and lingual brackets but not between lingual brackets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To investigate the composition and the microstructural and mechanical characterization of three different types of lingual brackets. MATERIALS AND METHODS Incognito™ (3M Unitek), In-Ovation L (DENTSPLY GAC) and STb™ (Light Lingual System, ORMCO) lingual brackets were studied under the scanning electron microscope employing backscattered electron imaging and their elemental composition was analysed by energy-dispersive X-ray microanalysis. Additionally, Vickers hardness was assessed using a universal hardness-testing machine, and the indentation modulus was measured according to instrumented indentation test. Two-way analysis of variance was conducted employing bracket type and location (base and wing) as discriminating variable. Significant differences among groups were allocated by post hoc Student-Newman-Keuls multiple comparison analysis at 95% level of significance. RESULTS Three different phases were identified for Incognito and In-Ovation L bracket based on mean atomic number contrast. On the contrary, STb did not show mean atomic contrast areas and thus it is recognized as a single phase. Incognito is a one-piece bracket with the same structure in wing and base regions. Incognito consists mainly of noble metals while In-Ovation L and STb show similar formulations of ferrous alloys in wing and base regions. No significant differences were found between ferrous brackets in hardness and modulus values, but there were significant differences between wing and base regions. Incognito illustrated intermediate values with significant differences from base and wing values of ferrous brackets. CONCLUSIONS/IMPLICATIONS Significant differences exist in microstructure, elemental composition, and mechanical properties among the brackets tested; these might have a series of clinical implications during mechanotherapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En este proyecto se estudian y analizan las diferentes técnicas de procesado digital de señal aplicadas a acelerómetros. Se hace uso de una tarjeta de prototipado, basada en DSP, para realizar las diferentes pruebas. El proyecto se basa, principalmente, en realizar filtrado digital en señales provenientes de un acelerómetro en concreto, el 1201F, cuyo campo de aplicación es básicamente la automoción. Una vez estudiadas la teoría de procesado y las características de los filtros, diseñamos una aplicación basándonos sobre todo en el entorno en el que se desarrollaría una aplicación de este tipo. A lo largo del diseño, se explican las diferentes fases: diseño por ordenador (Matlab), diseño de los filtros en el DSP (C), pruebas sobre el DSP sin el acelerómetro, calibración del acelerómetro, pruebas finales sobre el acelerómetro... Las herramientas utilizadas son: la plataforma Kit de evaluación 21-161N de Analog Devices (equipado con el entorno de desarrollo Visual DSP 4.5++), el acelerómetro 1201F, el sistema de calibración de acelerómetros CS-18-LF de Spektra y los programas software MATLAB 7.5 y CoolEditPRO 2.0. Se realizan únicamente filtros IIR de 2º orden, de todos los tipos (Butterworth, Chebyshev I y II y Elípticos). Realizamos filtros de banda estrecha, paso-banda y banda eliminada, de varios tipos, dentro del fondo de escala que permite el acelerómetro. Una vez realizadas todas las pruebas, tanto simulaciones como físicas, se seleccionan los filtros que presentan un mejor funcionamiento y se analizan para obtener conclusiones. Como se dispone de un entorno adecuado para ello, se combinan los filtros entre sí de varias maneras, para obtener filtros de mayor orden (estructura paralelo). De esta forma, a partir de filtros paso-banda, podemos obtener otras configuraciones que nos darán mayor flexibilidad. El objetivo de este proyecto no se basa sólo en obtener buenos resultados en el filtrado, sino también de aprovechar las facilidades del entorno y las herramientas de las que disponemos para realizar el diseño más eficiente posible. In this project, we study and analize digital signal processing in order to design an accelerometer-based application. We use a hardware card of evaluation, based on DSP, to make different tests. This project is based in design digital filters for an automotion application. The accelerometer type is 1201F. First, we study digital processing theory and main parameters of real filters, to make a design based on the application environment. Along the application, we comment all the different steps: computer design (Matlab), filter design on the DSP (C language), simulation test on the DSP without the accelerometer, accelerometer calibration, final tests on the accelerometer... Hardware and software tools used are: Kit of Evaluation 21-161-N, based on DSP, of Analog Devices (equiped with software development tool Visual DSP 4.5++), 1201-F accelerometer, CS-18-LF calibration system of SPEKTRA and software tools MATLAB 7.5 and CoolEditPRO 2.0. We only perform 2nd orden IIR filters, all-type : Butterworth, Chebyshev I and II and Ellyptics. We perform bandpass and stopband filters, with very narrow band, taking advantage of the accelerometer's full scale. Once all the evidence, both simulations and physical, are finished, filters having better performance and analyzed and selected to draw conclusions. As there is a suitable environment for it, the filters are combined together in different ways to obtain higher order filters (parallel structure). Thus, from band-pass filters, we can obtain many configurations that will give us greater flexibility. The purpose of this project is not only based on good results in filtering, but also to exploit the facilities of the environment and the available tools to make the most efficient design possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo in vivo, internacional, randomizado e duplo cedo foi avaliar comparativamente a efetividade e o pH de diferentes géis clareadores na técnica de clareamento em consultório, com e sem o emprego de fonte de luz híbrida em função do grau de alteração de cor, sensibilidade e manutenção do tratamento ao longo de 12 meses de acompanhamento. Foram selecionados 48 voluntários de acordo com os critérios de inclusão e exclusão. Os pacientes foram divididos, de forma randomizada, em 4 grupos de 12 participantes cada, onde: Grupo EXP10 5 aplicações do gel de peróxido de hidrogênio a 10% (Gel Experimental DMC Equipamentos) e ativação de luz híbrida de LED (violeta)/Laser (Experimental DMC Equipamentos) com 7′ e 30″ por aplicação, com tempo total de 37′30; Grupo LP15 5 aplicações do gel de peróxido de hidrogênio 15% (Lase Peroxide Lite DMC Equipamentos) seguindo mesmo protocolo do grupo EXP10; Grupo TB35LH 3 aplicações do gel de peróxido de hidrogênio a 35% (Total Blanc Office - DFL) e ativação de luz híbrida de LED (azul)/Laser (Whitening Lase II DMC Equipamentos) de 7′ e 30″ por aplicação, com tempo total de 22′30″; Grupo TB35 3 aplicações do gel de peróxido de hidrogênio a 35% (Total Blanc Office - DFL) sem ativação com fonte de luz, totalizando 45″. A determinação dos valores de pH foi realizada com o peagômetro digital (Sentron Model 1001, Sentron) nos tempos inicial e após o término do protocolo clareador. A aferição da cor foi feita com espectofotômetro VITA Easyshade antes do clareamento, após 24 horas, 1 semana, 1, 6 e 12 meses. A sensibilidade dentária e grau de satisfação dos pacientes foram avaliados por meio do questionário VAS e IPS antes, imediatamente após o clareamento, 24 horas e uma semana após. Os resultados da alteração do pH receberam tratamento estatístico pela ANOVA e teste de Bonferroni a 0,05%. Os resultados indicaram que o pH aumentou do momento inicial para o final para todos os protocolos. Não houve diferenças significativas entre os protocolos TB35 e TB35LH em nenhum dos momentos, e o pH médio do grupo EXP10 foi maior em comparação aos outros três grupos nos dois momentos avaliados. Os resultados do ΔE receberam tratamento estatístico pela ANOVA e teste de Bonferroni a 0,05%. Os resultados indicaram que não houve diferença significativa entre os grupos LP15, TB35 e TB35LH. O ΔE médio observado após 24 horas foi estatisticamente maior que para os outros tempos (inicial, 1 semana, 1 mês, 6 e 12 meses). Para análise da sensibilidade foi construído um modelo linear misto e atribuídos postos (ranks) aos valores de Δ e teste de Bonferroni a 0,05% para comparações pareadas. Não houve diferença nos valores da sensibilidade imediatamente e 24 horas após o tratamento, com relação ao momento inicial. Houve diferença significativa entre Δ1 e Δ3 indicando que a sensação de dor após uma semana do tratamento foi menor do que as observadas nos instantes imediato e após 24 horas. Para os resultados de satisfação foi construído um modelo linear misto e atribuídos postos (ranks) e o Método de Bonferroni (0,05%) foi utilizado para as comparações pareadas do efeito de tempo. Os resultados indicam queda nos níveis de satisfação entre os períodos imediato e um ano e entre os períodos 24 horas e um ano. Todos os géis clareadores apresentaram mínima variação do pH nos tempos avaliados, entretanto houve um aumento do pH da primeira para a última aplicação em todos os grupos estudados e o grupo EXP10 apresentou os maiores valores de pH seguido do LP15, TB35LH e TB35 apresentaram os valores mais baixos de pH. Os grupos LP15, TB35 e TB35LH apresentaram menor variação da cor ao longo de 12 meses de acompanhamento. O efeito do protocolo clareador não influenciou a sensibilidade dos pacientes e após uma semana a sensibilidade retornaram aos níveis normais. O nível de satisfação dos pacientes foi significativo em relação ao tempo e não aos protocolos clareadores, os pacientes do grupo TB35 mostraram-se mais insatisfeitos ao longo da pesquisa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O carcinoma epidermóide bucal (CEC) é uma neoplasia maligna com alta morbidade e mortalidade e de difícil tratamento. O tratamento convencional para o CEC inclui cirurgia e radioterapia, seguida ou não de quimioterapia. Apesar de serem amplamente difundidos, esses tratamentos podem ser ineficazes para alguns CECs resistentes. A terapia fotodinâmica (PDT) oncológica tem sido utilizada para o tratamento adjuvante do CEC bucal, principalmente nos casos menos invasivos e que necessitam de redução do tumor para a ressecção cirúrgica. Contudo, semelhantemente aos tratamentos convencionais, a PDT pode também induzir o aparecimento de populações celulares resistentes, fato já descrito para carcinoma cutâneo, adenocarcinoma de cólon e adenocarcinoma mamário. A hipótese de que células de CEC bucal possam desenvolver resistência à PDT ainda não foi testada. Portanto, o objetivo deste trabalho foi verificar se células de CEC bucal (SCC9) desenvolvem resistência a ciclos repetidos de PDT mediada pelo ácido 5- aminolevulínico (5-ALA-PDT) e avaliar se nesse processo ocorre modificação da expressão de marcadores relacionados a sobrevivência celular (NF?B, Bcl-2, iNOS, mTOR e Akt). Foi utilizada linhagem de células de CEC bucal (SCC9), submetida às seguintes condições: 1) Controle - células cultivadas sem nenhum tratamento; 2) ALA - células incubadas com 5-ALA (1mM durante 4 horas); 3) LED - tratadas com iluminação LED (630nm, 5,86J/cm2, 22,5J, 150mW, 150s); 4) PDT - tratadas com 5- ALA-PDT, com os protocolos do grupo ALA e LED combinados, gerando dose letal de 90%. Inicialmente foi realizado somente um ciclo de PDT, sendo avaliada a viabilidade celular em todos os grupos após 24, 48, 72 e 120h da irradiação. Também foi realizado ensaio de detecção da fragmentação de DNA (TUNEL) e análise por imunofluorescência da expressão das proteínas NF?B, Bcl-2, iNOS, pmTOR e pAkt nas células viáveis. Como resultado desse primeiro tratamento com 5-ALA-PDT, observou-se que as células sobreviventes ao tratamento apresentaram intensa marcação para pmTOR e exibiram potencial de crescimento durante o período analisado. Após esses ensaios, as células que sobreviveram a essa primeira sessão foram coletadas, replaqueadas e novamente cultivadas, sendo então submetidas a novo ciclo de 5-ALA-PDT. Esse processo foi realizado 5 vezes, variando-se a intensidade de irradiação à medida que se observava aumento na viabilidade celular. As populações celulares que exibiram viabilidade 1,5 vezes maior do que a detectada no primeiro ciclo PDT foram consideradas resistentes ao tratamento. Os mesmos marcadores analisados no primeiro ciclo de PDT foram novamente avaliados nas populações resistentes. Foram obtidas quatro populações celulares resistentes, com viabilidade de até 4,6 vezes maior do que a do primeiro ciclo de PDT e irradiação com LED que variou de 5,86 a 9,38J/cm2. A população mais resistente apresentou ainda menor intensidade de protoporfirina IX, maior capacidade de migração e modificação na morfologia nuclear. As populações resistentes testadas exibiram aumento na expressão de pNF?B, iNOS, pmTOR e pAkt, mas não da proteína anti-apoptótica Bcl- 2. Ensaio in vivo foi também conduzido em ratos, nos quais CEC bucal foi quimicamente induzido e tratado ou não com 5-ALA-PDT. Houve intensa expressão imuno-histoquímica das proteínas pNF?B, Bcl-2, iNOS, pmTOR e pAkt em relação ao controle não tratado, nas células adjacentes à área de necrose provocada pela PDT. Concluiu-se que as células de CEC bucal tratadas com 5-ALA-PDT a uma dose de 90% de letalidade desenvolveram viabilidade crescente após ciclos repetidos do tratamento, bem como exibiram superexpressão de proteínas relacionadas à sobrevivência celular, tanto in vitro quanto in vivo. Esses fatos, aliados à maior capacidade de migração, sugerem a aquisição de fenótipo de resistência à 5-ALAPDT. Esse aspecto deve ser cuidadosamente considerado no momento da instituição dessa terapia para os CECs bucais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O trabalho aborda o estudo e o desenvolvimento de um interferômetro sensor de alta tensão, baseado em célula Pockels (modulador eletro-óptico) na topologia reflexiva (\"double pass\") e que é parte integrante de um Transformador de Potencial Óptico (TPO), que utiliza sistema interferométrico de luz branca (WLI-White Light Interferometry), que está sendo desenvolvido pelo grupo do Laboratório de Sensores Ópticos (LSO) do PEA-EPUSP, e é capaz de medir diretamente tensões presentes em sistema elétrico de potência (SEP) classe 69kVRMS. Para desenvolver o tema proposto foi feita uma revisão da literatura baseada em livros, artigos e teses para identificar topologias em moduladores eletro-ópticos transmissiva (\"single pass\") e reflexiva (\"double pass\") para definir o tipo de modulador mais adequado para a aplicação em questão. A partir dos estudos e implementações realizadas, verificou-se um enorme potencial para o desenvolvimento e aplicação da topologia \"double pass\" no sensor interferométrico da célula de alta tensão do TPO. A topologia mostrou-se vantajosa em relação aos protótipos dos TPOs desenvolvidos anteriormente, a partir de características tais como: a facilidade de recurso de alinhamento do feixe de luz, construção e reprodução relacionados ao cristal eletro-óptico, diminuição do número de componentes ópticos volumétricos e aumento da rigidez dielétrica da célula sensora. Simulações computacionais foram realizadas mediante a aplicação do método dos elementos finitos (MEF) que contribuíram para o auxílio do projeto da célula sensora, particularmente, para estimativa do valor da voltagem de meia onda, V?, parâmetro importante para o projeto do TPO. Um protótipo do TPO com célula sensora de alta tensão reflexiva foi implementado e testado no laboratório de alta tensão do IEEUSP a partir de ensaios com tensões nominais de 69kVrms a 60Hz e máxima de 140kVrms a 60 Hz. Como resultado deste trabalho, amplia-se o conhecimento e domínio das técnicas de construção de interferômetros sensores de alta tensão na topologia reflexiva aplicadas a TPOs.