875 resultados para Intrusion Detection Systems
Resumo:
Chromatography combined with several different detection systems is one of the more used and better performing analytical tools. Chromatography with tandem mass spectrometric detection gives highly selective and sensitive analyses and permits obtaining structural information about the analites and about their molar masses. Due to these characteristics, this analytical technique is very efficient when used to detect substances at trace levels in complex matrices. In this paper we review instrumental and technical aspects of chromatography-tandem mass spectrometry and the state of the art of the technique as it is applied to analysis of toxic substances in food.
Resumo:
Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC.
Resumo:
Tässä työssä tutkittiin Stora Enso Oyj:n Heinolan Flutingtehtaan voimalaitos- ja jätevesien seuranta-analyysimenetelmien kehittämistä. Käytössä olevia menetelmiä vertailtiin vaihtoehtoisiin uusiin menetelmiin, jotka perustuvat erotustekniikoihin ja automaatioon. Flutingtehtaalla nykyisin käytössä olevat analyysimenetelmät perustuvat suurelta osin standardimäärityksiin, joissa käytetään pääasiassa titrausta. Määritykset vievät paljon aikaa, koska titraukset toteutetaan manuaalisesti. Titrausten päätepisteet tulkitaan esim. indikaattorin värinmuutoksella ja saostamalla, joten määritysten tarkkuus vaihtelee. Kokeellisessa osassa Flutingtehtaan puhtaista voimalaitosvesistä yhdistetty sekoitenäyte analysoitiin kahdella ionikromatografilla, liekkiatomiabsorptiospektrometrillä ja kapillaarielektroforeesilla. Yksittäisiä näytteitä ei tutkittu. Lisäksi vesilaboratoriossa määritettävistä jätevesistä yhdistettiin sekoitenäyte, joka analysoitiin kapillaarielektroforeesilla. Samat sekoitenäytteet analysoitiin myös nykyisillä menetelmillä tehtaan vesilaboratoriossa. Tulokset osoittivat, että kokeellisessa osassa tutkitut menetelmät soveltuvat sekoitenäytteen perusteella hyvin vesilaboratoriossa käytössä oleviin kuukausianalyyseihin. Automaattisella näytteensyötöllä varustettuna kaikki kolme kokeellisessa osassa tutkittua menetelmää ovat yksikertaisia käyttää ja ne nopeuttavat analyysejä. Päivittäisiä titrausanalyysejä voidaan tehostaa ja nopeuttaa automaation avulla. Erotustekniikoilla esimerkiksi typpi voidaan määrittää kokonaistyppenä, mutta myös komponentteinaan eli ammoniakkina, nitraattina ja nitriittinä. Lisäksi samalla erotuksella voidaan määrittää useita alkali- ja maa-alkalimetalleja sekä raskas-metalleja toistomittauksilla. Menetelmän käyttöalue on laajempi erotustekniikoilla kuin perinteisillä liuoskemian mittauksilla. Erotustekniikoilla tunnistetaan helposti määritysten oikeellisuus detektointimahdollisuuksien monipuolisuuden vuoksi.
Resumo:
Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.
Resumo:
After skin cancer, breast cancer accounts for the second greatest number of cancer diagnoses in women. Currently the etiologies of breast cancer are unknown, and there is no generally accepted therapy for preventing it. Therefore, the best way to improve the prognosis for breast cancer is early detection and treatment. Computer aided detection systems (CAD) for detecting masses or micro-calcifications in mammograms have already been used and proven to be a potentially powerful tool , so the radiologists are attracted by the effectiveness of clinical application of CAD systems. Fractal geometry is well suited for describing the complex physiological structures that defy the traditional Euclidean geometry, which is based on smooth shapes. The major contribution of this research include the development of • A new fractal feature to accurately classify mammograms into normal and normal (i)With masses (benign or malignant) (ii) with microcalcifications (benign or malignant) • A novel fast fractal modeling method to identify the presence of microcalcifications by fractal modeling of mammograms and then subtracting the modeled image from the original mammogram. The performances of these methods were evaluated using different standard statistical analysis methods. The results obtained indicate that the developed methods are highly beneficial for assisting radiologists in making diagnostic decisions. The mammograms for the study were obtained from the two online databases namely, MIAS (Mammographic Image Analysis Society) and DDSM (Digital Database for Screening Mammography.
Resumo:
This paper proposes a novel method of authentication of users in secure buildings. The main objective is to investigate whether user actions in the built environment can produce consistent behavioural signatures upon which a building intrusion detection system could be based. In the process three behavioural expressions were discovered: time-invariant, co-dependent and idiosyncratic.
Resumo:
A discharge-flow system, coupled to cavity-enhanced absorption spectroscopy (CEAS) detection systems for NO3 at lambda = 662 nm and NO2 at lambda = 404 nm, was used to investigate the kinetics of the reactions of NO3 with eight peroxy radicals at P similar to 5 Torr and T similar to 295 K. Values of the rate constants obtained were (k/10(-12) cm(3) molecule(-1) s(-1)): CH3O2 (1.1 +/- 0.5), C2H5O2 (2.3 +/- 0.7), CH2FO2 (1.4 +/- 0.9), CH2ClO2 (3.8(-2.6)(+1.4)), c-C5H9O2 (1.2(-0.5)(+1.1)), c-C6H11O2 (1.9 +/- 0.7), CF3O2 (0.62 +/- 0.17) and CF3CFO2CF3 (0.24 +/- 0.13). We explore possible relationships between k and the orbital energies of the reactants. We also provide a brief discussion of the potential impact of the reactions of NO3 with RO2 on the chemistry of the night-time atmosphere.
Resumo:
Accumulating data suggest that diets rich in flavanols and procyanidins are beneficial for human health. In this context, there has been a great interest in elucidating the systemic levels and metabolic profiles at which these compounds occur in humans. While recent progress has been made, there still exist considerable differences and various disagreements with regard to the mammalian metabolites of these compounds, which in turn is largely a consequence of the lack of availability of authentic standards that would allow for the directed development and validation of expedient analytical methodologies. In the present study, we developed a method for the analysis of structurally-related flavanol metabolites using a wide range of authentic standards. Applying this method in the context of a human dietary intervention study using comprehensively characterized and standardized flavanol- and procyanidin-containing cocoa, we were able to identify the structurally-related (−)-epicatechin metabolites (SREM) postprandially extant in the systemic circulation of humans. Our results demonstrate that (−)-epicatechin-3′-β-D-glucuronide, (−)-epicatechin-3′-sulfate, and a 3′-O-methyl(−)-epicatechin-5/7-sulfate are the predominant SREM in humans, and further confirm the relevance of the stereochemical configuration in the context of flavanol metabolism. In addition, we also identified plausible causes for the previously reported discrepancies regarding flavanol metabolism, consisting to a significant extent of inter-laboratory differences in sample preparation (enzymatic treatment and sample conditioning for HPLC analysis) and detection systems. Thus, these findings may also aid in the establishment of consensus on this topic.
Resumo:
This paper reports the first derived thermo-optical properties for vacuum deposited infrared thin films embedded in multilayers. These properties were extracted from the temperature-dependence of manufactured narrow bandpass filters across the 4-17 µm mid-infrared wavelength region. Using a repository of spaceflight multi-cavity bandpass filters, the thermo-optical expansion coefficients of PbTe and ZnSe were determined across an elevated temperature range 20-160 ºC. Embedded ZnSe films showed thermo-optical properties similar to reported bulk values, whilst the embedded PbTe films of lower optical density, deviate from reference literature sources. Detailed knowledge of derived coefficients is essential to the multilayer design of temperature-invariant narrow bandpass filters for use in non-cooled infrared detection systems. We further present manufacture of the first reported temperature-invariant multi-cavity narrow bandpass filter utilizing PbS chalcogenide layer material.
Resumo:
In this report, we describe a rapid and reliable process to bond channels fabricated in glass substrates. Glass channels were fabricated by photolithography and wet chemical etching. The resulting channels were bonded against another glass plate containing a 50-mu m thick PDMS layer. This same PDMS layer was also used to provide the electrical insulation of planar electrodes to carry out capacitively coupled contactless conductivity detection. The analytical performance of the proposed device was shown by using both LIF and capacitively coupled contactless conductivity detection systems. Efficiency around 47 000 plates/m was achieved with good chip-to-chip repeatability and satisfactory long-term stability of EOF. The RSD for the EOF measured in three different devices was ca. 7%. For a chip-to-chip comparison, the RSD values for migration time, electrophoretic current and peak area were below 10%. With the proposed approach, a single chip can be fabricated in less than 30 min including patterning, etching and sealing steps. This fabrication process is faster and easier than the thermal bonding process. Besides, the proposed method does not require high temperatures and provides excellent day-to-day and device-to-device repeatability.
Resumo:
The transport of fluids through pipes is used in the oil industry, being the pipelines an important link in the logistics flow of fluids. However, the pipelines suffer deterioration in their walls caused by several factors which may cause loss of fluids to the environment, justifying the investment in techniques and methods of leak detection to minimize fluid loss and environmental damage. This work presents the development of a supervisory module in order to inform to the operator the leakage in the pipeline monitored in the shortest time possible, in order that the operator log procedure that entails the end of the leak. This module is a component of a system designed to detect leaks in oil pipelines using sonic technology, wavelets and neural networks. The plant used in the development and testing of the module presented here was the system of tanks of LAMP, and its LAN, as monitoring network. The proposal consists of, basically, two stages. Initially, assess the performance of the communication infrastructure of the supervisory module. Later, simulate leaks so that the DSP sends information to the supervisory performs the calculation of the location of leaks and indicate to which sensor the leak is closer, and using the system of tanks of LAMP, capture the pressure in the pipeline monitored by piezoresistive sensors, this information being processed by the DSP and sent to the supervisory to be presented to the user in real time
Resumo:
Embedded systems are widely spread nowadays. An example is the Digital Signal Processor (DSP), which is a high processing power device. This work s contribution consist of exposing DSP implementation of the system logic for detecting leaks in real time. Among the various methods of leak detection available today this work uses a technique based on the pipe pressure analysis and usesWavelet Transform and Neural Networks. In this context, the DSP, in addition to do the pressure signal digital processing, also communicates to a Global Positioning System (GPS), which helps in situating the leak, and to a SCADA, sharing information. To ensure robustness and reliability in communication between DSP and SCADA the Modbus protocol is used. As it is a real time application, special attention is given to the response time of each of the tasks performed by the DSP. Tests and leak simulations were performed using the structure of Laboratory of Evaluation of Measurement in Oil (LAMP), at Federal University of Rio Grande do Norte (UFRN)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB