994 resultados para Internal logistics flow


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Micro-scale, two-phase flow is found in a variety of devices such as Lab-on-a-chip, bio-chips, micro-heat exchangers, and fuel cells. Knowledge of the fluid behavior near the dynamic gas-liquid interface is required for developing accurate predictive models. Light is distorted near a curved gas-liquid interface preventing accurate measurement of interfacial shape and internal liquid velocities. This research focused on the development of experimental methods designed to isolate and probe dynamic liquid films and measure velocity fields near a moving gas-liquid interface. A high-speed, reflectance, swept-field confocal (RSFC) imaging system was developed for imaging near curved surfaces. Experimental studies of dynamic gas-liquid interface of micro-scale, two-phase flow were conducted in three phases. Dynamic liquid film thicknesses of segmented, two-phase flow were measured using the RSFC and compared to a classic film thickness deposition model. Flow fields near a steadily moving meniscus were measured using RSFC and particle tracking velocimetry. The RSFC provided high speed imaging near the menisci without distortion caused the gas-liquid interface. Finally, interfacial morphology for internal two-phase flow and droplet evaporation were measured using interferograms produced by the RSFC imaging technique. Each technique can be used independently or simultaneously when.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Die Steuerung logistischer und produktionstechnischer Systeme ist heute durchgängig hierarchisch organisiert. Auch dezentrale und wandelbare Systeme mit eingebetteten fraktalen oder adaptiven Elementen oder Regelkreisen lassen sich in ihrer Gesamtheit stets auf eine zeitgenaue zentrale Planung zurückführen. „Realtime Logistics“ bezeichnet im Gegensatz hierzu die echtzeitnahe Materialflusssteuerung auf Basis einer autonomen, selbstgesteuerten Abwicklung der im einzelnen logistischen Objekt implementierten Mission. Hierzu werden mobile Softwareagenten eingesetzt, die zunächst synchron zum Objekt, und in Zukunft eingebettet im logistischen Objekt, laufen werden.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Chair of Transportation and Ware-housing at the University of Dortmund together with its industrial partner has developed and implemented a decentralized control system based on embedded technology and Internet standards. This innovative, highly flexible system uses autonomous software modules to control the flow of unit loads in real-time. The system is integrated into Chair’s test facility consisting of a wide range of conveying and sorting equipment. It is built for proof of concept purposes and will be used for further research in the fields of decentralized automation and embedded controls. This presentation describes the implementation of this decentralized control system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Im folgenden Beitrag werden zeitdiskrete analytische Methoden vorgestellt, mit Hilfe derer Informations- und Materialflüsse in logistischen Systemen analysiert und bewertet werden können. Bestehende zeitdiskrete Verfahren sind jedoch auf die Bearbeitung und Weitergabe in immer gleichen Mengen („One Piece Flow“) beschränkt. Vor allem in Materialflusssystemen kommt es, bedingt durch die Zusammenfassung von Aufträgen, durch Transporte und durch Sortiervorgänge, zur Bildung von Batches. Daher wurden analytische Methoden entwickelt, die es ermöglichen, verschiedene Sammelprozesse, Batchankünfte an Ressourcen, Batchbearbeitung und Sortieren von Batches analytisch abzubilden und Leistungskenngrößen zu deren Bewertung zu bestimmen. Die im Rahmen der Entwicklungsarbeiten entstandene Software-Lösung „Logistic Analyzer“ ermöglicht eine einfache Modellierung und Analyse von praktischen Problemen. Der Beitrag schließt mit einem numerischen Beispiel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today’s material flow systems for mass customization or dynamic productions are usually realized with manual transportation systems. However new concepts in the domain of material flow and device control like function-oriented modularization and intelligent multi-agent-systems offer the possibility to employ changeable and automated material flow systems in dynamic production structures. These systems need the ability to react on unplanned and unexpected events autonomously.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article deals with complex material flow systems and series connections of conveyor and op-erating elements. These can be characterised by a specific availability. The thus resultant overall availabil-ity of necessary “technical throughput” of the individual elements for the achievement of a specified throughput. When the conveyor and operating elements are subjected to a stochastic distribution, the interposition of buffers is necessary but these can also lead to a reduction of the necessary throughput due faults. The system behaviour of complex installations can only be investigated by simulation. The parame-ter changes required in order to achieve specific target values can also be determined by simulation runs in iteration loops.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Continuous conveyors with a dynamic merge were developed with adaptable control equipment to differentiate these merges from competing Stop-and-Go merges. With a dynamic merge, the partial flows are manipulated by influencing speeds so that transport units need not stop for the merge. This leads to a more uniform flow of materials, which is qualitatively observable and verifiable in long-term measurements. And although this type of merge is visually mesmerizing, does it lead to advantages from the view of material flow technology? Our study with real data indicates that a dynamic merge shows a 24% increase in performance, but only for symmetric or nearly symmetric flows. This performance advantage decreases as the flows become less symmetric, approaching the throughput of traditional Stop-and-Go merges. And with a cost premium for a continuous merge of approximately 10% due to the additional technical components (belt conveyor, adjustable drive engines, software, etc.), this restricts their economical use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Simulation techniques are almost indispensable in the analysis of complex systems. Materials- and related information flow processes in logistics often possess such complexity. Further problem arise as the processes change over time and pose a Big Data problem as well. To cope with these issues adaptive simulations are more and more frequently used. This paper presents a few relevant advanced simulation models and intro-duces a novel model structure, which unifies modelling of geometrical relations and time processes. This way the process structure and their geometric relations can be handled in a well understandable and transparent way. Capabilities and applicability of the model is also presented via a demonstrational example.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Mechanical thrombectomy using stent retriever devices have been advocated to increase revascularization in intracranial vessel occlusion. We present the results of a large prospective study on the use of the Solitaire Flow Restoration in patients with acute ischemic stroke. METHODS Solitaire Flow Restoration Thrombectomy for Acute Revascularization was an international, multicenter, prospective, single-arm study of Solitaire Flow Restoration thrombectomy in patients with large vessel anterior circulation strokes treated within 8 hours of symptom onset. Strict criteria for site selection were applied. The primary end point was the revascularization rate (thrombolysis in cerebral infarction ≥2b) of the occluded vessel as determined by an independent core laboratory. The secondary end point was the rate of good functional outcome (defined as 90-day modified Rankin scale, 0-2). RESULTS A total of 202 patients were enrolled across 14 comprehensive stroke centers in Europe, Canada, and Australia. The median age was 72 years, 60% were female patients. The median National Institute of Health Stroke Scale was 17. Most proximal intracranial occlusion was the internal carotid artery in 18%, and the middle cerebral artery in 82%. Successful revascularization was achieved in 79.2% of patients. Device and procedure-related severe adverse events were found in 7.4%. Favorable neurological outcome was found in 57.9%. The mortality rate was 6.9%. Any intracranial hemorrhagic transformation was found in 18.8% of patients, 1.5% were symptomatic. CONCLUSIONS In this single-arm study, treatment with the Solitaire Flow Restoration device in intracranial anterior circulation occlusions results in high rates of revascularization, low risk of clinically relevant procedural complications, and good clinical outcomes in combination with low mortality at 90 days. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The cerebral network that is active during rest and is deactivated during goal-oriented activity is called the default mode network (DMN). It appears to be involved in self-referential mental activity. Atypical functional connectivity in the DMN has been observed in schizophrenia. One hypothesis suggests that pathologically increased DMN connectivity in schizophrenia is linked with a main symptom of psychosis, namely, misattribution of thoughts. Methods: A resting-state pseudocontinuous arterial spin labeling (ASL) study was conducted to measure absolute cerebral blood flow (CBF) in 34 schizophrenia patients and 27 healthy controls. Using independent component analysis (ICA), the DMN was extracted from ASL data. Mean CBF and DMN connectivity were compared between groups using a 2-sample t test. Results: Schizophrenia patients showed decreased mean CBF in the frontal and temporal regions (P < .001). ICA demonstrated significantly increased DMN connectivity in the precuneus (x/y/z = -16/-64/38) in patients than in controls (P < .001). CBF was not elevated in the respective regions. DMN connectivity in the precuneus was significantly correlated with the Positive and Negative Syndrome Scale scores (P < .01). Conclusions: In schizophrenia patients, the posterior hub-which is considered the strongest part of the DMN-showed increased DMN connectivity. We hypothesize that this increase hinders the deactivation of the DMN and, thus, the translation of cognitive processes from an internal to an external focus. This might explain symptoms related to defective self-monitoring, such as auditory verbal hallucinations or ego disturbances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The function of naturally existing internal mammary (IMA)-to-coronary artery bypasses and their quantitative effect on myocardial ischemia are unknown. METHODS AND RESULTS The primary end point of this study was collateral flow index (CFI) obtained during two 1-minute coronary artery balloon occlusions, the first with and the second without simultaneous distal IMA occlusion. The secondary study end point was the quantitatively determined intracoronary ECG ST-segment elevation. CFI is the ratio of simultaneously recorded mean coronary occlusive pressure divided by mean aortic pressure both subtracted by mean central venous pressure. A total of 180 pairs of CFI measurements were performed among 120 patients. With and without IMA occlusion, CFI was 0.110±0.074 and 0.096±0.072, respectively (P<0.0001). The difference of CFI obtained in the presence minus CFI obtained in the absence of IMA occlusion was highest and most consistently positive during left IMA with left anterior descending artery occlusion and during right IMA with right coronary artery occlusion (ipsilateral occlusions): 0.033±0.044 and 0.025±0.027, respectively. This CFI difference was absent during right IMA with left anterior descending artery occlusion and during left IMA with right coronary artery occlusion (contralateral occlusions): -0.007±0.034 and 0.001±0.023, respectively (P=0.0002 versus ipsilateral occlusions). The respective CFI differences during either IMA with left circumflex artery occlusion were inconsistently positive. Intracoronary ECG ST-segment elevations were significantly reduced during ipsilateral IMA occlusions but not during contralateral or left circumflex artery occlusions. CONCLUSION There is a functional, ischemia-reducing extracardiac coronary artery supply via ipsilateral but not via contralateral natural IMA bypasses. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCTO1676207.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present synopsis aims to integrate one study about memory training in very preterm-born children and two studies about cognition in patients with carotid artery stenosis before and after treatments. Preterm-born children are at increased risk of cognitive deficits and behavioural problems compared with peers born at term. This thesis determined whether memory training would improve cognitive functions in school-age very preterm-born children. Memory strategy training produced significant improvements in trained and non-trained cognitive functions; a core working memory training revealed significant effects on short-term memory and working memory tasks. Six months after training, children in both training groups showed better working memory performance than children in the waiting control group. This is evidence that memory training – an external influence on cognition – induces plastic changes in very preterm-born children. Patients with carotid artery stenosis are known to be at increased risk of cognitive impairment. We showed that patients with symptomatic or asymptomatic carotid artery stenosis were at higher risk for cognitive deficits than expected in a normative sample. This thesis seeks to link cognitive plasticity to internal factors like carotid stenosis. An external factor, which influences blood flow to the brain is the nature of the carotid artery stenosis treatment. Research on the effects of carotid artery stenosis treatment on cognition has produced inconsistent results. We found significant improvement in frontal lobe functions, visual memory and motor speed one year after treatment independent of the treatment type (best medical treatment, carotid artery stenting, carotid artery endarterectomy); providing evidence for ‘treatment-induced’ cognitive plasticity. Baseline performance was negatively associated with improvement in various cognitive functions after training in very preterm-born children and after treatment in patients with carotid artery stenosis. The present synopsis aims to integrate these findings into the current and relevant literature, and discuss consequences as well as methodological considerations resulting from the studies constituting the thesis at hand.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the morpho-sedimentary characterization and interpretations of the assemblage of landforms of the East Greenland continental slope and Greenland Basin, based on swath bathymetry and sub-bottom TOPAS profiles. The interpretation of landforms reveals the glacial influence on recent sedimentary processes shaping the seafloor, including mass-wasting and turbidite flows. The timing of landform development points to a predominantly glacial origin of the sediment supplied to the continental margin, supporting the scenario of a Greenland Ice Sheet extending across the continental shelf, or even to the shelf-edge, during the Last Glacial Maximum (LGM). Major sedimentary processes along the central section of the eastern Greenland Continental Slope, the Norske margin, suggest a relatively high glacial sediment input during the LGM that, probably triggered by tectonic activity, led to the development of scarps and channels on the slope and debris flows on the continental rise. The more southerly Kejser Franz Josef margin has small-scale mass-wasting deposits and an extensive turbidite system that developed in relation to both channelised and unconfined turbidity flows which transferred sediments into the deep Greenland Basin.