923 resultados para Indicator
Resumo:
A printable, multicomponent, UV-sensitive indicator which provides different coloured, flag-like warnings of the approach to erythema is described.
Resumo:
The preparation and characterisation of a novel, UV-activated, solvent-based, colourimetric indicator for oxygen is described, comprising a redox dye (methylene blue, MB), semiconductor photocatalyst (Pt-TiO2), and a sacrificial electron donor (SED = glycerol), all dispersed/dissolved in a polymer medium (sulfonated polystyrene. SPS). Upon exposure to UVA light, the Pt-TiO2/MB/glycerol/SPS oxygen indicator is readily photobleached as the MB is converted into its oxygen-sensitive, leuco form, LMB. In contrast to its non-platinised TiO2 counterpart (TiO2/MB/glycerol/SPS oxygen indicator), the recovery of the original colour is faster (ca. 1.5 days cf. 5 days at 21 degrees C). This is due to the catalytic action of the 0.38 wt% platinum loaded onto the semiconductor photocatalyst. TiO2, on the oxidation of the photogenerated LMB by ambient O-2. Furthermore, by increasing the level of platinum loading, recovery times can be decreased further; e.g. a Pt-TiO2/MB/glycerol/SPS oxygen indicator with platinum level of 1.52 wt% recovers fully within 12 h. A study of the kinetics of recovery as a function of film thickness revealed the recovery step is not controlled by the diffusion of O-2 through the film, but instead dependent upon the slow rate of oxidation of LMB to MB by O-2 in the low dielectric polymer encapsulation medium. Other work showed this recovery is only moderately dependant upon temperatures above -10 degrees C and very sensitive to relative humidity above 30% RH. Potential uses of this UV light activated indicator are discussed briefly. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The preparation and characterisation of a novel, UV-activated solvent-based, colourimetric indicator for O-2 is described, comprising a redox dye (methylene blue, MB), semiconductor photocatalyst (TiO2), and a sacrificial electron donor (SED), all dispersed/dissolved in a polymer medium (sulfonated polystyrene, SPS). Upon exposure, the indicator is readily photobleached as the MB is converted into its oxygen-sensitive, leuco form, LMB. Unlike its water-based counterpart, the recovery of the original colour is very slow (ca. 5 days cf. 6 min), probably due to the largely hydrophobic nature of the polymer encapsulation medium. The kinetics of film photobleaching appear to fit very well, in terms of: irradiance, [TiO2] and [MB], to the usual Langmuir-Hinshelwood type equation associated with a photocatalytic process. The glycerol appears not only to function as a SED, but also a plasticizer and medium for dye dissolution. The kinetics of colour recovery of the photobleached film appear directly dependent upon the ambient level of O-2 but shows a more complex dependence upon the relative humidity, RH. The photobleached film does not recover any of its colour over a 24 h period if the RH
Resumo:
A novel colourimetric 'fizziness' indicator is described which changes colour depending on the headspace pressure of carbon dioxide above a carbonated liquid.
Resumo:
A new relative-humidity sensitive ink based on methylene blue and urea is described which can utilise the deliquescent nature of urea.
Resumo:
The kinetics of dye reduction, in photocatalyst indicator ink films on self cleaning glass, is studied with respect to dye concentration. The water-based, photocatalyst indicator inks comprised a redox dye, D-ox, a sacrificial electron donor (glycerol) and a polymer, hydroxyethyl cellulose. The dyes used were: Resazurin (Rz), dichloroindo-phenol (DCIP) and methylene blue (MB), although the latter required acidification of the ink (0.01M HCl) to make it work effectively under ambient conditions. Under anaerobic conditions, the photoreduction of each of the dyes, in an otherwise identical ink formulation, on Activ (TM) self-cleaning glass is zero-order with respect to [D-ox]. Seven commercial samples of Rz, each in a typical ink formulation, were tested on the same piece of self-cleaning glass under aerobic conditions and produced a striking range (over 280%) of different apparent activities for the glass, when there should have been none. The underlying cause of this variation in assessed activity is shown to be due to the combination of a variation in the purity of the commercial samples and the zero-order nature of the kinetics of indicator dye reduction. The relevance of this work and the latter observation, in particular to future use of these films for the rapid assessment of the activities of new and established photocatalytic films, is briefly discussed.
Resumo:
A new photocatalyst indicator ink based on methylene blue (MB) is described that allows the presence and activity of a thin (15 nm) photocatalytic film to be assessed in seconds. The ink is very stable (shelf life > 6 months) and the color change (blue to colorless) striking. The ink utilizes a sacrificial electron donor, glycerol, to trap the photogenerated holes, leaving the photogenerated electrons to react with MB to produce its. reduced, leuco, form (LMB). The efficacy of the MB ink is due to the presence of acid in its formulation, which curtails significantly. the otherwise usual, rapid reoxidation of LMB by ambient O-2.
Resumo:
Nanocrystalline SnO2, ncSnO(2), is used as a photosensitiser in a colourimetric O-2 indicator that comprises a sacrificial electron donor, glycerol, a redox dye, methylene blue (MB), and an encapsulating polymer, hydroxyethyl cellulose (HEC). Upon exposure to a burst of UVB light the indicator is activated (photo-bleached) as the MB is photoreduced by the ncSnO(2) particles. In the absence of oxygen, the film stays bleached, but recovers its original colour upon exposure to oxygen. Unlike its TiO2-based predecessor, the HEC/glycerol/MB/ncSnO(2) O-2 indicator is not activated by UVA light from white fluorescent lamps, but is by UVB light. This feature provides much greater control in the activation of the indicator. Other work shows the rate of activation depends upon I-0.75, where I is the UVB irradiance, indicating a partial dependence upon the electron-hole recombination process. The half-life of the recovery of the original colour of a UV-activated film, t(50), is directly proportional to the ambient level of oxygen. The advantages of using this indicator in modified atmosphere packaging as a possible quality assurance indicator are discussed briefly. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
A hydrogen peroxide vapour indicator is described comprising a triarylmethane dye, lissamine green (LG), dissolved in a polymer, polyvinyl alcohol (PVA). The indicator is green/blue in the absence of hydrogen peroxide vapour but is rapidly bleached in the presence of hydrogen peroxide vapour. The kinetics of LG bleaching appear approximately first order with respect [LG] and the concentration of H2O2, which, in turn, is proportional to the partial pressure of H2O2. However, the kinetics also appear to depend directly upon the reciprocal of the film thickness, implying some dependence upon the diffusion of the H2O2 vapour through the indicator film. Like most other H2O2 indicator films (such as starch-iodide paper), the LG/PVA indicator is not particularly selective and responds to most other volatile strong oxidising agents, such as ozone and chlorine. However, it is rapid in response (
Resumo:
An oxygen indicator is described, comprising nanoparticles of titania dispersed in hydroxyethyl cellulose (HEC) polymer film containing a sacrificial electron donor, glycerol, and the redox indicator, indigo-tetrasulfonate (ITS). The indicator is blue-coloured in the absence of UV light, however upon exposure to UV light it not only loses its colour but also luminesces, unless and until it is exposed to oxygen, whereupon its original colour is restored. The initial photobleaching spectral ( absorbance and luminescence) response characteristics in air and in vacuum are described and discussed in terms of a simple reaction scheme involving UV activation of the titania photocatalyst particles, which are used to reduce the redox dye, ITS, to its leuco form, whilst simultaneously oxidising the glycerol to glyceraldehye. The response characteristics of the activated, that is, UV photobleached, form of the indicator to oxygen are also reported and the possible uses of such an indicator to measure ambient O-2 levels are discussed. Copyright (C) 2008 Andrew Mills et al.
Resumo:
This article reports the behaviour of three photocatalyst indicator inks, based on the redox dyes: methylene blue (NIB), resorufin (Rf) and 2,6-dichloroindophenol (DCIP), and assess their performance in comparison to the pioneering resazurin (Rz)-based ink for the rapid assessment of the activity of very thin, photocatalyst films, such as Activ (TM) self-cleaning glass. From a commercial 'demonstrator of photocatalysis' perspective, all three redox dyes appear more attractive compared to Rz since all generate colourless products in the ink formulation when photoreduced on Activ (TM) under anaerobic conditions, whereas, the reduced product from Rz, the redox dye resorufin, Rf. is pink in colour. However, the ink based on Rf is far too slow to effect the rapid measurement of photocatalytic activity even in the absence of oxygen, and in the presence of oxygen the latter inhibits the overall kinetics of photoreduction by re-oxidising the reduced product, dihydroresorufin, HRf, back to Rf. Similarly, despite the attractive rapid rate of photobleaching for NIB under anaerobic conditions, compared to the other redox dyes, the reduced product of the MB-based ink. leuco-MB, is so oxygen-sensitive that the ink cannot be photoreduced under aerobic conditions, thus rendering the ink unsuitable for use in the field. The DCIP-based ink is slightly less easy to photoreduce under both anaerobic and ambient atmospheric conditions compared to the Rz-based ink. However. in addition to its more attractive colour change, the DCIP-based ink is unaffected by the ambient level of oxygen present (%O-2) and the relative humidity (%RH), whereas, for the Rz-based ink, both parameters effect the photoreduction kinetics. By incorporating the DCIP ink into a felt-tipped pen, the ink is suitable for use in the laboratory and field to perform not only a qualitative test, but also to allow a semi-quantitative analysis of photocatalytic activity by eye. (C) 2007 Elsevier B.V. All rights reserved.