996 resultados para Implementation accuracy
Resumo:
Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)
Resumo:
Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872
Resumo:
Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)
Resumo:
Background. Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. Methods. One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (eg, severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal Concordance between modalities was expressed at kappa Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS video-tape was used to store video data The reading time and storage costs for each modality were compared Results. Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thicken ing (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P < .001). Compressed digital studies had an average size of 60 <plus/minus> 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). Conclusion. Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.
Resumo:
The subjective interpretation of dobutamine echocardiography (DBE) makes the accuracy of this technique dependent on the experience of the observer, and also poses problems of concordance between observers. Myocardial tissue Doppler velocity (MDV) may offer a quantitative technique for identification of coronary artery disease, but it is unclear whether this parameter could improve the results of less expert readers and in segments with low interobserver concordance. The aim of this study was to find whether MDV improved the accuracy of wall motion scoring in novice readers, experienced echocardiographers, and experts in stress echocardiography, and to identify the optimal means of integrating these tissue Doppler data in 77 patients who underwent DBE and angiography. New or worsening abnormalities were identified as ischemia and abnormalities seen at rest as scarring. Segmental MDV was measured independently and previously derived cutoffs were applied to categorize segments as normal or ab normal. Five strategies were used to combine MDV and wall motion score, and the results of each reader using each strategy were compared with quantitative coronary angiography. The accuracy of wall motion scoring by novice (68 +/- 3%) and experienced echocardiographers (71 +/- 3%) was less than experts in stress echocardiography (88 +/- 3%, p < 0.001). Various strategies for integration with MDV significantly improved the accuracy of wall motion scoring by novices from 75 +/- 2% to 77 +/- 5% (p < 0.01). Among the experienced group, accuracy improved from 74 +/- 2% to 77 +/- 5% (p < 0.05), but in the experts, no improvement was seen from their baseline accuracy. Integration with MDV also improved discordance related to the basal segments. Thus, use of MDV in all segments or MDV in all segments with wall motion scoring in the apex offers an improvement in sensitivity and accuracy with minimal compromise in specificity. (C) 2001 by Excerpta Medica, Inc.
Resumo:
In population pharmacokinetic studies, the precision of parameter estimates is dependent on the population design. Methods based on the Fisher information matrix have been developed and extended to population studies to evaluate and optimize designs. In this paper we propose simple programming tools to evaluate population pharmacokinetic designs. This involved the development of an expression for the Fisher information matrix for nonlinear mixed-effects models, including estimation of the variance of the residual error. We implemented this expression as a generic function for two software applications: S-PLUS and MATLAB. The evaluation of population designs based on two pharmacokinetic examples from the literature is shown to illustrate the efficiency and the simplicity of this theoretic approach. Although no optimization method of the design is provided, these functions can be used to select and compare population designs among a large set of possible designs, avoiding a lot of simulations.
Resumo:
Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
Telemedicine is often proposed as a solution to certain health-care problems in the developing world. There seems to be little published experience on which to make judgements. A literature search revealed 39 articles, of which only two related to any kind of direct clinical work; most of them were review articles or editorials. The majority of the work reported was educational in nature, and there has been little clinical experience. It seems probable that telemedicine can help with the education of health-care workers and patients; it seems likely that it could bring major benefits to the organization of health-care. Without proper trials, it will be impossible to determine the place of health-care in the developing world. Trials are the only way in which rational decisions can ultimately be reached regarding whether scarce resources should be devoted to telemedicine in developing countries, or whether they should be employed in more conventional health-care measures whose outcomes are known to be cost-effective.
Resumo:
It has been recognised that in order to study the displacement, timing and co-ordination of articulatory components (i.e., tongue. lips, jaw) in speech production it is desirable to obtain high-resolution movement data on multiple structures inside and outside the vocal tract. Until recently, with the exception of X-ray techniques such as cineradiography, the study 0. speech movements has been hindered by the inaccessibility of the oral cavity during speech. X-ray techniques are generally not used because of unacceptable radiation exposure. The aim of the present study was to demonstrate the use of a new physiological device, the electromagnetic articulograph, for assessing articulatory dysfunction subsequent to traumatic brain injury. The components of the device together with the measuring principle are described and data collected from a single case presented. A 19 year-old male who exhibited dysarthria subsequent to a traumatic brain injury was fitted wit 2 the electromagnetic articulograph (Carstens AG-100) and a kinematic analysis of his tongue movements during production of the lingual consonants it, s, k/ within single syllable words was performed. Examination of kinematic parameters including movemmt trajectories, velocity, and acceleration revealed differences in the speed and accuracy of his tongue movements compared to those produced by a non-neurologically impaired adult male. It was concluded that the articulograph is a useful device for diagnosing speed and accuracy disorders in tongue movements during speech and that the device has potential for incorporation into physiologically based rehabilitation programs as a real-time biofeedback instrument.
Resumo:
Diagnosis involves a complex and overlapping series of steps, each of which may be a source of error and of variability between clinicians. This variation may involve the ability to elicit relevant information from the client or animal, in the accuracy, objectivity and completeness of relevant memory stores, and in psychological attributes including tolerance for uncertainty and willingness to engage in constructive self-criticism. The diagnostic acumen of an individual clinician may not be constant, varying with external and personal factors, with different clients and cases, and with the use made of tests. In relation to clients, variations may occur in the ability to gain their confidence, to ask appropriate questions and to evaluate accurately both verbal and nonverbal responses. Tests may introduce problems of accuracy, validity, sensitivity, specificity, interpretation and general appropriateness for the case. Continuing effectiveness as a diagnostician therefore requires constant attention to the maintenance of adequate and up-to-date skills and knowledge relating to the animals and their diseases and to tests, and of sensitive interpersonal skills.
Resumo:
Objective: To assess the diagnostic error rate among echocardiograms undertaken by individuals other than paediatric cardiologists in our referral area. Methodology: External group: The charts and echocardiographic results of all patients who had undergone outside echocardiograms between January 1996 and December 1999 were reviewed (110). Age at echocardiography, diagnostic complexity, presence of any diagnostic errors and the severity of any diagnostic errors were identified. Internal group: To assess our own error rate, the initial echocardiographic diagnoses of 100 patients undergoing cardiac catheterisation or corrective surgery were compared with the post-catheterisation or postoperative diagnoses. Age and diagnostic complexity were also assessed in the control group. Results: Diagnostic errors occurred in 47/110 patients (44%) of the externally studied group (of which 24% were either major or life threatening) as opposed to 3/100 of the internally studied group, despite the internally studied group being of increased diagnostic complexity. Errors were more common and of increased severity in infants less than 1 month of age but extended throughout all age groups. Major and life threatening errors increased with increasing diagnostic complexity. In the externally studied group, 8/47 errors were patients inappropriately designated as normal. Four of these patients required cardiac surgery or interventional cardiac catheterisation. Conclusions: This study suggests an unacceptably high error rate in paediatric echocardiographic diagnoses by non-paediatric cardiologists throughout all age groups. Such errors are more likely in younger infants and with increasing diagnostic complexity.
Resumo:
Objective To assess the accuracy of intra-operative frozen section reports at identifying the features of high risk uterine disease compared with final histopathology. Design Retrospective study. Methods The records, of 460 patients with uterine cancer registered with the Queensland Centre for Gynaecological Cancer between January 1, 1996 and December 31, 1998 were reviewed. Intra-operative frozen section was undertaken in 260 patients with endometrial adenocarcinoma. Frozen section pathology was compared with the final histopathology reports. Inter-observer reliability was assessed using percentage agreement and kappa statistics. Clinical notes were also reviewed to determine if errors resulted in sub-optimal patient care. Results Respectively, tumour grade and depth of myometrial invasion were accurately reported in 88.6% of cases (expected 61.5%, Kappa 0.70) and 94.7% (expected 53.8%, Kappa 0.89). Errors were predominantly attributable to difficulties with respect to the interpretation of tumour grade. The error resulted in the patient receiving sub-optimal surgical management in only I I cases (5.3%) Conclusion Frozen section is accurate at identifying the features of high risk uterine disease in the setting of endometrial cancer and can play an important role in directing primary operative management.