954 resultados para Icc
Resumo:
The Pulmonary Embolism Severity Index (PESI) is a validated clinical prognostic model for patients with acute pulmonary embolism (PE). Our goal was to assess the PESI's inter-rater reliability in patients diagnosed with PE. We prospectively identified consecutive patients diagnosed with PE in the emergency department of a Swiss teaching hospital. For all patients, resident and attending physician raters independently collected the 11 PESI variables. The raters then calculated the PESI total point score and classified patients into one of five PESI risk classes (I-V) and as low (risk classes I/II) versus higher-risk (risk classes III-V). We examined the inter-rater reliability for each of the 11 PESI variables, the PESI total point score, assignment to each of the five PESI risk classes, and classification of patients as low versus higher-risk using kappa (κ) and intra-class correlation coefficients (ICC). Among 48 consecutive patients with an objective diagnosis of PE, reliability coefficients between resident and attending physician raters were > 0.60 for 10 of the 11 variables comprising the PESI. The inter-rater reliability for the PESI total point score (ICC: 0.89, 95% CI: 0.81-0.94), PESI risk class assignment (κ: 0.81, 95% CI: 0.66-0.94), and the classification of patients as low versus higher-risk (κ: 0.92, 95% CI: 0.72-0.98) was near perfect. Our results demonstrate the high reproducibility of the PESI, supporting the use of the PESI for risk stratification of patients with PE.
Resumo:
This doctoral thesis proposes an International Criminal Court Specialized in Economic Crime (ICC/EC) as a solution to the main obstacles to the effectiveness of international anti-corruption conventions studied. In fact, the dispute settlement systems of the international anti-corruption Conventions do not provide sufficient guarantees of effectiveness, and offenses and crimes of corruption are not under the jurisdiction of the International Criminal Court (ICC) derived from the Rome Statute of 2000. In a first part, this work analyzes seven international anti-corruption Conventions adopted between 1996 and 2003, respectively, by the Organization of American States (OAS), the Organization for Economic Cooperation and Development (OECD), the European Union (EU), the Council of Europe (CoE), the African Union (AU) and the United Nations (UN). In a second part, this study highlights a deficit of rationalization and optimization of offenses included in the conventions: an incomplete criminalization of legal persons for corruption, an equally insufficient criminalization for corruption of political leaders benefiting both from criminal and civil immunities, as well as the limited outcome of international asset recovery de-rived from corruption. Finally, given the previous analysis made, this thesis concludes with a pro-posal for an independent ICC/EC specific to economic crimes in order to overcome the major obstacles highlighted and which strongly affect the effectiveness of the international anti-corruption conventions. - Cet ouvrage de thèse doctorale propose, comme solution principale aux obstacles à l'effectivité des Conventions anti-corruption internationales étudiées, une Cour Pénale Internationale Spécialisée en Criminalité Economique (CPI/CE). En effet, les systèmes de règlement des différends des Conven¬tions anti-corruption internationales n'offrent pas suffisamment de gage d'effectivité et les délits et crimes de corruption transnationale ne sont pas de la compétence de la Cour Pénale Internationale (CPI) issue du statut de Rome de 2000. Dans un premier temps, le présent ouvrage analyse sept Conventions anti-corruption internationales adoptées entre 1996 et 2003, respectivement, par l'Organisation des Etats Américains (OEA), l'Organisation de Coopération et de Développement Economiques (OCDE), l'Union européenne (UE), le Conseil de l'Europe (CoE), l'Union Africaine (UA) et l'Organisation des Nations Unies (ONU). Dans un deuxième temps, l'ouvrage met en lumière un déficit de rationalisation et d'optimisation des incriminations que contiennent les Conventions, dont notamment : une incrimination lacunaire des personnes morales pour corruption, une incrimination tout aussi insuffisante pour corruption des dirigeants politiques au bénéfice d'immunités pénale et civile et une restitu¬tion internationale des avoirs issus de la corruption à portée limitée. Finalement, c'est au vu de l'analyse effectuée que le présent ouvrage conclut avec la proposition d'une CPI/CE indépendante et spécifique aux crimes économiques afin de pallier au mieux les obstacles majeurs mis en exergue et qui nuisent fortement à l'effectivité des Conventions anti-corruption internationales.
Resumo:
ABSTRACT: BACKGROUND: Upregulation of nuclear factor kappa B (NFκB) activity and neuroendocrine differentiation are two mechanisms known to be involved in prostate cancer (PC) progression to castration resistance. We have observed that major components of these pathways, including NFκB, proteasome, neutral endopeptidase (NEP) and endothelin 1 (ET-1), exhibit an inverse and mirror image pattern in androgen-dependent (AD) and -independent (AI) states in vitro. METHODS: We have now investigated for evidence of a direct mechanistic connection between these pathways with the use of immunocytochemistry (ICC), western blot analysis, electrophoretic mobility shift assay (EMSA) and proteasome activity assessment. RESULTS: Neuropeptide (NP) stimulation induced nuclear translocation of NFκB in a dose-dependent manner in AI cells, also evident as reduced total inhibitor κB (IκB) levels and increased DNA binding in EMSA. These effects were preceded by increased 20 S proteasome activity at lower doses and at earlier times and were at least partially reversed under conditions of NP deprivation induced by specific NP receptor inhibitors, as well as NFκB, IκB kinase (IKK) and proteasome inhibitors. AD cells showed no appreciable nuclear translocation upon NP stimulation, with less intense DNA binding signal on EMSA. CONCLUSIONS: Our results support evidence for a direct mechanistic connection between the NPs and NFκB/proteasome signaling pathways, with a distinct NP-induced profile in the more aggressive AI cancer state.
Resumo:
Résumé Introduction : La chirurgie de la maladie de Hirschsprung est fréquemment compliquée d'une atteinte post-opératoire de la motilité intestinale. Des anomalies du système nerveux entérique (SNE) telles que la dysplasie neuronale intestinale de type B, l'hypoganglionose ou l'aganglionose, présents dans le segment abaissé, peuvent être la cause de certaines de ces complications mais aucune information n'est disponible quant au rôle des cellules interstitielles de Cajal (CIC) sur la motilité intestinale dans la phase post-opératoire. Ces cellules sont considérées avoir un rôle de pacemaker dans le tractus gastro-intestinal. L'objectif de cette étude était de décrire la distribution des CIC dans le segment proximal du côlon réséqué lors de cures chirurgicales de maladie de Hirschsprung et de confronter ces observations à l'évolution clinique post-opératoire. Matériel et Méthodes : L'incidence des complications post-opératoires a été déterminée par une revue rétrospective des dossiers de 48 patients opérés pour maladie de Hirschspung entre 1977 et 1999 et par l'étude histologique et immuno-histochimique des pièces réséquées chez ces patients. Nous avons comparé la distribution des CIC dans le segment proximal du côlon avec celle du côlon sain de 16 enfants contrôles par microscopie optique. L'immunohistochimie au c-Kit a été utilisée pour marquer spécifiquement les CIC sur échantillons paraffinés. Ces résultats ont ensuite été corrélés avec l'étude du SNE de ces mêmes segments, déterminée par immunohistochimie au CD56 et au protein gene product 9.5. Résultats Les complications post-opératoires suivantes furent identifiées : constipation 46%, constipation avec incontinence 15%, entérocolite 8%, décès 4% (probablement sur entérocolite). La distribution des CIC dans les segments proximaux réséqués chez les enfants avec maladie de Hirschsprung était identique à celle observée dans les segments de côlon sain, et ce indépendamment de la distribution normale ou anormale du SNE. Chez les enfants opérés pour maladie de Hirschsprung les segments réséqués présentaient les anomalies d'innervation suivantes : aganglionose 10.4%, hypoganglionose 12.5%, dysplasie neuronale intestinale de type B 6.3%, autres dysganglionoses 14.6%. Aucune relation entre ces anomalies d'innervation et les complications post-opératoires n'a été mise en évidence. Conclusion : La distribution des CIC est normale chez les patient opérés pour maladie de Hirschsprung, et ne contribue donc pas aux atteintes post-opératoires de la motilité intestinale. Cela signifie aussi que le réseau de CIC se développe noinialement dans le côlon humain, même en présence d'une innervation colique anormale ou absente. Abstract: Surgery for Hirschsprung's disease is often complicated by post-operative bowel motility disorders. The impact of intestinal neural histology on the surgical outcome has been previously studied, but no information is available concerning the influence of the distribution of interstitial cells of Cajal (ICC) on these complications. These cells are considered to be pacemakers in the gastrointestinal tract. The aim of this study was to assess the distribution of ICC in the proximal segment of resected bowel in Hirschsprung's disease and confront these results with the clinical outcome. Using immunohistochemistry for light microscopy, we compared the pattern of distribution of ICC in the proximal segment of resected bowel in Hirschsprung's disease with that in normal colon. We correlated these results with the corresponding neural intestinal histology determined by CD56 and the protein gene product 9.5 immunohistochemistry. The distribution of ICC in the proximal segment of resected bowel is identical to that of normal colon, regardless of normal or abnormal colon innervation. ICC distribution does not seem to contribute to post-operative bowel motility disorders in patients operated for Hirschsprung's disease.
Resumo:
BACKGROUND: In Switzerland, nurses are allowed to prescribe and administer morphine in emergency situations without a doctor. Still, nurses and other health professionals are often reluctant to prescribe and administer morphine for pain management in patients. No valid French-speaking instrument is available in Switzerland to assess the attitudes of nurses and other health professionals towards the prescription and administration of morphine. In this study, we evaluated the psychometric properties of the French version of the questionnaire "Attitudes towards morphine use". METHODS: The instrument was derived from an Italian version. Forward and back translations of the questionnaire were performed. Item analysis and construct validity were assessed between April and December 2010 in a cross sectional study including five Swiss hospitals in a sample of 588 health professionals (533 nurses, mean age 38.3 ± 10.2 years). Thirty subjects participated in test-retest reliability. RESULTS: The time to complete the instrument ranged between 12 and 15 minutes and neither floor nor ceiling effect were found. The initial 24-item instrument showed an intraclass correlation (ICC) of 0.69 (95% CI: 0.64 to 0.73, P < 0.001), and a Cronbach's α of 0.700. Factor analysis led to a six-component solution explaining 52.4% of the total variance. After excluding five items, the shortened version showed an ICC of 0.74 (95% CI, 0.70 to 0.77, P < 0.001) and a Cronbach's α of 0.741. Factor analysis led to a five-component solution explaining 54.3% of the total variance. The five components were named "risk of addiction/dependence"; "operational reasons for not using morphine"; "risk of escalation"; "other (non-dependence) risks" and "external (non-operational) reasons". In test-retest, the shortened instrument showed an ICC of 0.797 (95% CI, 0.630 to 0.911, P < 0.001) and a Cronbach's α of 0.797. CONCLUSIONS: The 19-item shortened instrument assessing attitudes towards the prescription and administration of morphine showed adequate content and construct validity.
Resumo:
BACKGROUND: Anterior shoulder stabilization surgery with the arthroscopic Bankart procedure can have a high recurrence rate in certain patients. Identifying these patients to modify outcomes has become a focal point of research. PURPOSE: The Instability Shoulder Index Score (ISIS) was developed to predict the success of arthroscopic Bankart repair. Scores range from 0 to 10, with higher scores predicting a higher risk of recurrence after stabilization. The interobserver reliability of the score is not known. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: This is a prospective multicenter (North America and Europe) study of patients suffering from shoulder instability and waiting for stabilization surgery. Five pairs of independent evaluators were asked to score patient instability severity with the ISIS. Patients also completed functional scores (Western Ontario Shoulder Instability Index [WOSI], Disabilities of the Arm, Shoulder and Hand-short version [QuickDASH], and Walch-Duplay test). Data on age, sex, number of dislocations, and type of surgery were collected. The test-retest method and intraclass correlation coefficient (ICC: >0.75 = good, >0.85 = very good, and >0.9 = excellent) were used for analysis. RESULTS: A total of 114 patients with anterior shoulder instability were included, of whom 89 (78%) were men. The mean age was 28 years. The ISIS was very reliable, with an ICC of 0.933. The mean number of dislocations per patient was higher in patients who had an ISIS of ≥6 (25 vs 14; P = .05). Patients who underwent more complex arthroscopic procedures such as Hill-Sachs remplissage or open Latarjet had higher preoperative ISIS outcomes, with a mean score of 4.8 versus 3.4, respectively (P = .002). There was no correlation between the ISIS and the quality-of-life questionnaires, with Pearson correlations all >0.05 (WOSI = 0.39; QuickDASH = 0.97; Walch-Duplay = 0.08). CONCLUSION: Our results show that the ISIS is reliable when used in a multicenter study with anterior traumatic instability populations. There was no correlation between the ISIS and the quality-of-life questionnaires, but surgical decisions reflected its increased use.
Resumo:
BACKGROUND. The NDI, COM and NPQ are evaluation instruments for disability due to NP. There was no Spanish version of NDI or COM for which psychometric characteristics were known. The objectives of this study were to translate and culturally adapt the Spanish version of the Neck Disability Index Questionnaire (NDI), and the Core Outcome Measure (COM), to validate its use in Spanish speaking patients with non-specific neck pain (NP), and to compare their psychometric characteristics with those of the Spanish version of the Northwick Pain Questionnaire (NPQ). METHODS. Translation/re-translation of the English versions of the NDI and the COM was done blindly and independently by a multidisciplinary team. The study was done in 9 primary care Centers and 12 specialty services from 9 regions in Spain, with 221 acute, subacute and chronic patients who visited their physician for NP: 54 in the pilot phase and 167 in the validation phase. Neck pain (VAS), referred pain (VAS), disability (NDI, COM and NPQ), catastrophizing (CSQ) and quality of life (SF-12) were measured on their first visit and 14 days later. Patients' self-assessment was used as the external criterion for pain and disability. In the pilot phase, patients' understanding of each item in the NDI and COM was assessed, and on day 1 test-retest reliability was estimated by giving a second NDI and COM in which the name of the questionnaires and the order of the items had been changed. RESULTS. Comprehensibility of NDI and COM were good. Minutes needed to fill out the questionnaires [median, (P25, P75)]: NDI. 4 (2.2, 10.0), COM: 2.1 (1.0, 4.9). Reliability: [ICC, (95%CI)]: NDI: 0.88 (0.80, 0.93). COM: 0.85 (0.75,0.91). Sensitivity to change: Effect size for patients having worsened, not changed and improved between days 1 and 15, according to the external criterion for disability: NDI: -0.24, 0.15, 0.66; NPQ: -0.14, 0.06, 0.67; COM: 0.05, 0.19, 0.92. Validity: Results of NDI, NPQ and COM were consistent with the external criterion for disability, whereas only those from NDI were consistent with the one for pain. Correlations with VAS, CSQ and SF-12 were similar for NDI and NPQ (absolute values between 0.36 and 0.50 on day 1, between 0.38 and 0.70 on day 15), and slightly lower for COM (between 0.36 and 0.48 on day 1, and between 0.33 and 0.61 on day 15). Correlation between NDI and NPQ: r = 0.84 on day 1, r = 0.91 on day 15. Correlation between COM and NPQ: r = 0.63 on day 1, r = 0.71 on day 15. CONCLUSION. Although most psychometric characteristics of NDI, NPQ and COM are similar, those from the latter one are worse and its use may lead to patients' evolution seeming more positive than it actually is. NDI seems to be the best instrument for measuring NP-related disability, since its results are the most consistent with patient's assessment of their own clinical status and evolution. It takes two more minutes to answer the NDI than to answer the COM, but it can be reliably filled out by the patient without assistance. TRIAL REGISTRATION Clinical Trials Register NCT00349544.
Resumo:
This study examined the validity and reliability of a sequential "Run-Bike-Run" test (RBR) in age-group triathletes. Eight Olympic distance (OD) specialists (age 30.0 ± 2.0 years, mass 75.6 ± 1.6 kg, run VO2max 63.8 ± 1.9 ml· kg(-1)· min(-1), cycle VO2peak 56.7 ± 5.1 ml· kg(-1)· min(-1)) performed four trials over 10 days. Trial 1 (TRVO2max) was an incremental treadmill running test. Trials 2 and 3 (RBR1 and RBR2) involved: 1) a 7-min run at 15 km· h(-1) (R1) plus a 1-min transition to 2) cycling to fatigue (2 W· kg(-1) body mass then 30 W each 3 min); 3) 10-min cycling at 3 W· kg(-1) (Bsubmax); another 1-min transition and 4) a second 7-min run at 15 km· h(-1) (R2). Trial 4 (TT) was a 30-min cycle - 20-min run time trial. No significant differences in absolute oxygen uptake (VO2), heart rate (HR), or blood lactate concentration ([BLA]) were evidenced between RBR1 and RBR2. For all measured physiological variables, the limits of agreement were similar, and the mean differences were physiologically unimportant, between trials. Low levels of test-retest error (i.e. ICC <0.8, CV<10%) were observed for most (logged) measurements. However [BLA] post R1 (ICC 0.87, CV 25.1%), [BLA] post Bsubmax (ICC 0.99, CV 16.31) and [BLA] post R2 (ICC 0.51, CV 22.9%) were least reliable. These error ranges may help coaches detect real changes in training status over time. Moreover, RBR test variables can be used to predict discipline specific and overall TT performance. Cycle VO2peak, cycle peak power output, and the change between R1 and R2 (deltaR1R2) in [BLA] were most highly related to overall TT distance (r = 0.89, p < 0. 01; r = 0.94, p < 0.02; r = 0.86, p < 0.05, respectively). The percentage of TR VO2max at 15 km· h(-1), and deltaR1R2 HR, were also related to run TT distance (r = -0.83 and 0.86, both p < 0.05).
Resumo:
BACKGROUND Several questionnaires have been used to measure health related quality of life (HRQoL) in patients with psoriasis, few have been adapted for use in Spain; none of them was developed specifically for the Spanish population. The purpose of the study was to validate and assess the sensitivity to change of a new questionnaire to measure HRQOL in patients with psoriasis (PSO-LIFE). METHODS Observational, prospective, multicenter study performed in centers around Spain. Patients with active or inactive psoriasis completed the PSO-LIFE together with other Dermatology Quality of Life Index (DLQI) and Psoriasis Disability Index (PDI). A control group of patients with urticaria or atopic dermatitis was also included. Internal consistency and test-retest reliability of the PSO-LIFE were assessed by calculating Cronbach's alpha and Intraclass Correlation Coefficient (ICC). Validity was assessed by examining factorial structure, the capacity to discriminate between groups, and correlations with other measures. Sensitivity to change was measured using effect sizes. RESULTS The final sample included for analysis consisted of 304 patients and 56 controls. Mean (SD) age of psoriasis patients was 45.3 (14.5) years compared to 38.8 (14) years for controls (p < 0.01). Cronbach's alpha for the PSO-LIFE was 0.95 and test-retest reliability using the ICC was 0.98. Factor analysis showed the questionnaire to be unidimensional. Mean (SD) PSO-LIFE scores differed between patients with psoriasis and controls (64.9 [22.5] vs 69.4 [17.3]; p < 0.05), between those with active and inactive disease (57.4 [20.4] vs 76.4 [20.6]; p < 0.01), and between those with visible and non-visible lesions (63.0 [21.9] vs. 74.8 [23.9]; p < 0.01). The correlation between PSO-LIFE and PASI scores was moderate (r = -0.43) while correlations with DLQI and PDI dimensions ranged from moderate to high (between 0.4 and 0.8). Effect size on the PSO-LIFE in patients reporting 'much improved' health status at study completion was 1.01 (large effect size). CONCLUSIONS The present results provide substantial support for the reliability, validity, and responsiveness of the PSO-LIFE questionnaire in the population for which it was designed.
Resumo:
BACKGROUND: Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. PARTICIPANTS AND METHODS: Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. RESULTS: The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). CONCLUSIONS: Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.
Resumo:
Background: Current guidelines underline the limitations of existing instruments to assess fitness to drive and the poor adaptability of batteries of neuropsychological tests in primary care settings. Aims: To provide a free, reliable, transparent computer based instrument capable of detecting effects of age or drugs on visual processing and cognitive functions. Methods: Relying on systematic reviews of neuropsychological tests and driving performances, we conceived four new computed tasks measuring: visual processing (Task1), movement attention shift (Task2), executive response, alerting and orientation gain (Task3), and spatial memory (Task4). We then planned five studies to test MedDrive's reliability and validity. Study-1 defined instructions and learning functions collecting data from 105 senior drivers attending an automobile club course. Study-2 assessed concurrent validity for detecting minor cognitive impairment (MCI) against useful field of view (UFOV) on 120 new senior drivers. Study-3 collected data from 200 healthy drivers aged 20-90 to model age related normal cognitive decline. Study-4 measured MedDrive's reliability having 21 healthy volunteers repeat tests five times. Study-5 tested MedDrive's responsiveness to alcohol in a randomised, double-blinded, placebo, crossover, dose-response validation trial including 20 young healthy volunteers. Results: Instructions were well understood and accepted by all senior drivers. Measures of visual processing (Task1) showed better performances than the UFOV in detecting MCI (ROC 0.770 vs. 0.620; p=0.048). MedDrive was capable of explaining 43.4% of changes occurring with natural cognitive decline. In young healthy drivers, learning effects became negligible from the third session onwards for all tasks except for dual tasking (ICC=0.769). All measures except alerting and orientation gain were affected by blood alcohol concentrations. Finally, MedDrive was able to explain 29.3% of potential causes of swerving on the driving simulator. Discussion and conclusions: MedDrive reveals improved performances compared to existing computed neuropsychological tasks. It shows promising results both for clinical and research purposes.
Resumo:
The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.
Resumo:
BACKGROUND: The Foot and Ankle Ability Measure (FAAM) is a self reported questionnaire for patients with foot and ankle disorders available in English, German, and Persian. This study plans to translate the FAAM from English to French (FAAM-F) and assess the validity and reliability of this new version.METHODS: The FAAM-F Activities of Daily Living (ADL) and sports subscales were completed by 105 French-speaking patients (average age 50.5 years) presenting various chronic foot and ankle disorders. Convergent and divergent validity was assessed by Pearson's correlation coefficients between the FAAM-F subscales and the SF-36 scales: Physical Functioning (PF), Physical Component Summary (PCS), Mental Health (MH) and Mental Component Summary (MCS). Internal consistency was calculated by Cronbach's Alpha (CA). To assess test re-test reliability, 22 patients filled out the questionnaire a second time to estimate minimal detectable changes (MDC) and intraclass correlation coefficients (ICC).RESULTS: Correlations for FAAM-F ADL subscale were 0.85 with PF, 0.81 with PCS, 0.26 with MH, 0.37 with MCS. Correlations for FAAM-F Sports subscale were 0.72 with PF, 0.72 with PCS, 0.21 with MH, 0.29 with MCS. CA estimates were 0.97 for both subscales. Respectively for the ADL and Sports subscales, ICC were 0.97 and 0.94, errors for a single measure were 8 and 10 points at 95% confidence and the MDC values at 95% confidence were 7 and 18 points.CONCLUSION: The FAAM-F is valid and reliable for the self-assessment of physical function in French-speaking patients with a wide range of chronic foot and ankle disorders.
Resumo:
Expressions relating spectral efficiency, power and Doppler spectrum are derived for low-power Rayleighfaded wireless channels with proper complex signaling. Noside information on the state of the channel is assumed at the receiver. Rather, periodic reference signals are postulated inaccordance with the functioning of most wireless systems. In contrast with most previous studies, which relied on block-fading channel models, a continuous-fading model is adopted. This embeds the Doppler spectrum directly in thederived expressions thereby imbuing them with practical significance.
Resumo:
For single-user MIMO communication with uncoded and coded QAM signals, we propose bit and power loading schemes that rely only on channel distribution information at the transmitter. To that end, we develop the relationship between the average bit error probability at the output of a ZF linear receiver and the bit rates and powers allocated at the transmitter. This relationship, and the fact that a ZF receiver decouples the MIMO parallel channels, allow leveraging bit loading algorithms already existing in the literature. We solve dual bit rate maximization and power minimization problems and present performance resultsthat illustrate the gains of the proposed scheme with respect toa non-optimized transmission.