943 resultados para ISCEV STANDARD
Resumo:
The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, (99m)Tc- and (18)F-labelled radiopharmaceuticals for diagnostic and (90)Y-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure.
Resumo:
We analyzed the initial adhesion and biofilm formation of Staphylococcus aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984) on various bone grafts and bone graft substitutes under standardized in vitro conditions. In parallel, microcalorimetry was evaluated as a real-time microbiological assay in the investigation of biofilm formation and material science research. The materials beta-tricalcium phosphate (beta-TCP), processed human spongiosa (Tutoplast) and poly(methyl methacrylate) (PMMA) were investigated and compared with polyethylene (PE). Bacterial counts (log(10) cfu per sample) were highest on beta-TCP (S. aureus 7.67 +/- 0.17; S. epidermidis 8.14 +/- 0.05) while bacterial density (log(10) cfu per surface) was highest on PMMA (S. aureus 6.12 +/- 0.2, S. epidermidis 7.65 +/- 0.13). Detection time for S. aureus biofilms was shorter for the porous materials (beta-TCP and processed human spongiosa, p < 0.001) compared to the smooth materials (PMMA and PE), with no differences between beta-TCP and processed human spongiosa (p > 0.05) or PMMA and PE (p > 0.05). In contrast, for S. epidermidis biofilms the detection time was different (p < 0.001) between all materials except between processed human spongiosa and PE (p > 0.05). The quantitative analysis by quantitative culture after washing and sonication of the material demonstrated the importance of monitoring factors like specific surface or porosity of the test materials. Isothermal microcalorimetry proved to be a suitable tool for an accurate, non-invasive and real-time microbiological assay, allowing the detection of bacterial biomass without removing the biofilm from the surface.
Resumo:
Par le biais d'une procédure Test-Retest, la stabilité à long terme des indices standard du WISC-IV français a été évaluée. L'intervalle moyen entre les deux passations est de 2,33 ans. L'échantillon comprend 96 enfants « tout venant » âgés de huit à 12 ans. Les comparaisons entre les moyennes des deux passations ne montrent pas de différence significative pour indice de compréhension verbale (ICV), indice de raisonnement perceptif (IRP), indice de mémoire de travail (IMT), indice d'aptitude générale (IAG) et QIT. Au niveau interindividuel, les coefficients de corrélations témoignent d'une bonne stabilité à long terme pour ICV, IAG et QIT (allant de 0,81 à 0,82). Une analyse des différences de performances entre les deux passations indique une stabilité intra-individuelle satisfaisante pour IMT et IAG. Seul IAG présente donc une stabilité à long terme satisfaisante au niveau inter- et intra-individuel. By a Test-Retest procedure, this study explores the long-term stability of the French WISC-IV index scores. The average Test-Retest interval was 2.33 years. The sample consisted of 96 non-clinical children aged between 8 and 12 years. Mean difference between the two testings was not statistically significant for VCI, PRI, WMI, GAI and FSIQ. Test-Retest reliability correlations between the two assessments are high for VCI, GAI and FSIQ (ranging from .81 to .82). An analysis of the performance differences between two assessments indicates intra-individual stability for WMI and GAI. In sum, only GAI demonstrates reliable long-term stability at an inter-and intra-individual level.
Resumo:
We evaluated midterm patient-reported outcomes and satisfaction with total hip arthroplasty in patients who had severe juvenile idiopathic arthritis. Thirty-one patients (49 hips), with a mean age of 29 years (range, 16-43 years), reported low hip pain and stiffness at follow-up (mean, 7 years; range, 3-17 years). Up to 92% were satisfied with their ability to perform various activities; 96% were satisfied with pain relief. A mean postoperative flexion arc of 96° was observed. Final 36-Item Short Form Health Survey, EuroQol in 5 dimensions, Western Ontario and McMaster Universities Arthritis Index, and Harris Hip scores were lower than reference populations, particularly for mobility, physical functioning, and social functioning subscores. Young adults with end-stage hip involvement and severe longstanding juvenile idiopathic arthritis expressed high satisfaction with total hip arthroplasty, which improved range of motion, pain, and stiffness, despite poor performance on widely used outcome measures.
Resumo:
It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility.
Resumo:
In a prospective study the functional results after dissection or preservation of the serratus anterior muscle in the postero-lateral standard thoracotomy were evaluated. In 14 patients of our clinic with dissection and suture and in 14 patients with preservation of the serratus muscle the muscle function was assessed and compared preoperatively, within the first two post-operative weeks, and three months after the operation by the same physiotherapists. The two groups were blinded in regard to age, original disease, and mode of intervention. We compared the wing position of the scapula in the sitting position and the positioning of the scapula at fixation of the shoulder joint in the sitting and in the supine position. Using a four-grade function assessment scheme, both groups obtained the same functional results. There was no seroma in either group. After 2.8 (2.5 to 3.0) years all the surviving patients described symmetric functional conditions. We therefore conclude that in order to achieve a better view of the operative field the serratus muscle may be dissected close to the origin if it is then readapted.
Resumo:
In this report, sixteen secondary and primary bridge standards for two types of bridges are rated for AASHTO HS20-44 vehicle configuration utilizing Load Factor methodology. The ratings apply only to those bridges which: (1) are built according to the applicable bridge standard plans, (2) have no structural deterioration or damage, and (3) have no added wearing surface in excess of one-half inch integral wearing surface.
Resumo:
In this report, 25 secondary bridge standards for three types of bridges are rated for the AASHTO HS20-44 vehicle configuration and five typical Iowa legal vehicles. The ratings apply only to those bridges which: (1) are built according to the applicable bridge standard plans, (2) have no structural deterioration or damage, and (3) have no added wearing surface in excess of 0.5-in. (1.27-cm) integral wearing surface. Appendix A contains the results of the original October 1982 report on load ratings for standard bridges.
Resumo:
Esitelmä Suomen ISBN-keskus 30 vuotta -juhlassa Helsingin yliopistossa 7.11.2002
Resumo:
Interdependence is the main feature of dyadic relationships and, in recent years, various statistical procedures have been proposed for quantifying and testing this social attribute in different dyadic designs. The purpose of this paper is to develop several functions for this kind of statistical tests in an R package, known as nonindependence, for use by applied social researchers. A Graphical User Interface (GUI) is also developed to facilitate the use of the functions included in this package. Examples drawn from psychological research and simulated data are used to illustrate how the software works.
Resumo:
The load ratings for these Standard bridges were calculated in compliance with the 1978 AASHTO Manual for Maintenance Inspection of Bridges, using the appropriate allowable stresses for the materials specified by the Standard plans. Distribution of loads is in compliance with the Manual unless otherwise noted. Except for truss spans, all bridges with roadway widths of 18 ft. or less were rated for one lane of traffic. All 18 ft. roadway truss bridges were rated for both one and two lanes of traffic. All bridges with roadway widths exceeding 18 ft. were rated for two lanes of traffic. If the posting rating for two lane bridges was less than legal, then the bridges were rated for traffic restricted to one lane, or to one lane centered in the roadway, as noted on the summary sheet. The ratings are applicable to bridges built in accordance with the standard plans and which exhibit no significant deterioration or damage to the structural members, and which have no added wearing surface material in excess of that noted on the summary sheets and used in the calculations. The inventory and operating ratings were based upon the standard AASHTO HS20-44 loading. The legal load ratings were based upon the three typical Iowa legal vehicles shown on page 5. The legal load ratings were based upon the maximum allowable Operating Rating stresses specified in the Manual. Refer to notations on the summary sheets for additional qualifications on the load ratings for specific standard bridge series. Load ratings for standard bridges with wood floors must be based upon existing conditions of attachment of the wood flooring to the top flanges of longitudinal steel stringers. The ratings must be reevaluated if the existing lateral support conditions are not in accordance with conditions used for the rating and noted on the summary sheets. Details of most of the standard bridges are included in the three books of "Iowa State Highway Commission, Bridge Standards," issued in June, 1972. Copies of plans for those standard bridges that were rated, and that are not included in the original books of standard plans, are being furnished under separate cover with these rating summaries.
Resumo:
OBJECTIVE: To compare image quality of a standard-dose (SD) and a low-dose (LD) cervical spine CT protocol using filtered back-projection (FBP) and iterative reconstruction (IR). MATERIALS AND METHODS: Forty patients investigated by cervical spine CT were prospectively randomised into two groups: SD (120 kVp, 275 mAs) and LD (120 kVp, 150 mAs), both applying automatic tube current modulation. Data were reconstructed using both FBP and sinogram-affirmed IR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured. Two radiologists independently and blindly assessed the following anatomical structures at C3-C4 and C6-C7 levels, using a four-point scale: intervertebral disc, content of neural foramina and dural sac, ligaments, soft tissues and vertebrae. They subsequently rated overall image quality using a ten-point scale. RESULTS: For both protocols and at each disc level, IR significantly decreased image noise and increased SNR and CNR, compared with FBP. SNR and CNR were statistically equivalent in LD-IR and SD-FBP protocols. Regardless of the dose and disc level, the qualitative scores with IR compared with FBP, and with LD-IR compared with SD-FBP, were significantly higher or not statistically different for intervertebral discs, neural foramina and ligaments, while significantly lower or not statistically different for soft tissues and vertebrae. The overall image quality scores were significantly higher with IR compared with FBP, and with LD-IR compared with SD-FBP. CONCLUSION: LD-IR cervical spine CT provides better image quality for intervertebral discs, neural foramina and ligaments, and worse image quality for soft tissues and vertebrae, compared with SD-FBP, while reducing radiation dose by approximately 40 %.
Resumo:
When referenced, the 2012 edition of the Iowa Department of Transportation’s (Iowa DOT) Standard Specifications for Highway and Bridge Construction shall be used for contract work awarded by the Iowa DOT. They may also be incorporated by reference in other contract work on secondary, urban, local systems, or other contract work in which the Iowa DOT has an interest. As modified by the General Supplemental Specifications, these Standard Specifications represent the minimum requirements and may be modified by Supplemental Specifications, Developmental Specifications, and Special Provisions on specific contracts. These Standard Specifications have been written so the Contractor’s responsibilities are indicated by plain language using the Imperative Mood and Active Voice form. Sentences are of the form: Construct isolation joints at all points where driveways meet other walks, curbs, or fixtures in the surface. Ensure finished members are true to detailed dimensions and free from twists, bends, open joints, or other defects resulting from faulty fabrication or defective work. Personnel preparing the JMF shall be Iowa DOT certified in bituminous mix design. The Contracting Authority’s responsibilities are (with some exceptions) indicated by the use of the modal verb “will”. Sentences are of the form: The Engineer will obtain and test density samples for each lot according to Materials I.M. 204. Payment will be the contract unit price for Fabric Reinforcement per square yard (square meter). These standard specifications contain dual units of measure: the United States Standard measure (English units) and the International System of Units (SI or “metric” units). The English units are expressed first then followed by the metric units in parentheses. The measurements expressed in the two systems are not necessarily equal. In some cases the measurements in metric units is a “hard” conversion of the English measurement; i.e. the metric unit has been approximated with a rounded, rationalized metric measurement that is easy to work with and remember. The proposal form will identify whether the work was designed and shall be constructed in English or metric units.
Resumo:
BACKGROUND: Despite the increasing use of Roux-en-Y gastric bypass (RYGBP) in the treatment of morbid obesity, data about postoperative nutritional deficiencies and their treatment remain scarce. OBJECTIVE: The aim of this study was to evaluate the efficacy of a standard multivitamin preparation in the prevention and treatment of nutritional deficiencies in obese patients after RYGBP. DESIGN: This was a retrospective study of 2 y of follow-up of obese patients after RYGBP surgery. Between the first and the sixth postoperative months, a standardized multivitamin preparation was prescribed for all patients. Specific requirements for additional substitutive treatments were systematically assessed by a biologic workup at 3, 6, 9, 12, 18, and 24 mo. RESULTS: A total of 137 morbidly obese patients (110 women and 27 men) were included. The mean (+/-SD) age at the time of surgery was 39.9 +/- 10.0 y, and the body mass index (in kg/m(2)) was 46.7 +/- 6.5. Three months after RYGBP, 34% of these patients required at least one specific supplement in addition to the multivitamin preparation. At 6 and 24 mo, this proportion increased to 59% and 98%, respectively. Two years after RYGBP, a mean amount of 2.9 +/- 1.4 specific supplements had been prescribed for each patient, including vitamin B-12, iron, calcium + vitamin D, and folic acid. At that time, the mean monthly cost of the substitutive treatment was $34.83. CONCLUSION: Nutritional deficiencies are very common after RYGBP and occur despite supplementation with the standard multivitamin preparation. Therefore, careful postoperative follow-up is indicated to detect and treat those deficiencies.