994 resultados para IRON 55
Resumo:
In the title compound, [Al(C8H4F3O2S)3]3[Fe(C8H4F3O2S)3], the metal centre is statistically occupied by AlIII and FeIII cations in a 3:1 ratio. The metal centre is within an octahedral O6 donor set defined by three chelating substituted acetoacetonate anions. The ligands are arranged around the periphery of the molecule with a mer geometry of the S atoms.
Resumo:
In this work, natural palygorskite impregnated with zero-valent iron (ZVI) was prepared and characterised. The combination of ZVI particles on surface of fibrous palygorskite can help to overcome the disadvantage of ultra-fine powders which may have strong tendency to agglomerate into larger particles, resulting in an adverse effect on both effective surface area and catalyst performance. There is a significant increase of methylene blue (MB) decolourized efficiency on acid treated palygorskite with ZVI grafted, within 5 mins, the concentration of MB in the solution was decreased from 94 mg/L to around 20 mg/L and the equilibration was reached at about 30 to 60 mins with only around 10 mg/L MB remained in solution. Changes in the surface and structure of prepared materials were characterized using X-ray diffraction (XRD), infrared (IR) spectroscopy, surface analysing and scanning electron microscopy (SEM) with element analysis and mapping. Comparing with zero-valent iron and palygorskite, the presence of zero-valent iron reactive species on the palygorskite surface strongly increases the decolourization capacity for methylene blue, and it is significant for providing novel modified clay catalyst materials for the removal of organic contaminants from waste water.
Resumo:
Purpose: In the present work we consider our (in progress) spectroscopy study of zinc and iron phosphates under the influence external high pressure to determine zinc ion change coordination from tetrahedral to octahedral (or hexahedral) structure.----- Design/methodology/approach: The standard equipment is the optical high pressure cell with diamond (DAC). The DAC is assembled and then vibrational or electronic spectra are collected by mounting the cell in an infrared, Raman, EXAFS or UV-visible spectrometer.----- Findings: Mechanism by which zinc and iron methaphosphate material is transformed to glassy meta-phosphate is enhancing mechanical properties of tribofilm. The two decades of intensive study demonstrates that Zn (II) and Fe (III) ions participate to cross-link network under friction, hardening the phosphate.----- Research limitations/implications: Transition metal atoms with d orbital have flexible coordination numbers, for example zinc acts as a cross-linking agent increasing hardness, by changing coordination from tetrahedral to octahedral. Perhaps the external pressure effect on the [Zn–(O-P-)4 ] complex causes a transformation to an [Zn –(O-P-)6] grouping.----- Originality/value: This paper analyses high-pressure spectroscopy which has been applied for the investigation of 3D transition metal ions in solids. When studying pressure effects on coordination compounds structure, we can expect changes in ground electronic state (spin-crossovers), electronic spectra due to structural distortions (piezochromism), and changes in the ligand field causing shifts in the electronic transitions.
Resumo:
We examined differences in response latencies obtained during a validated video-based hazard perception driving test between three healthy, community-dwelling groups: 22 mid-aged (35-55 years), 34 young-old (65-74 years), and 23 old-old (75-84 years) current drivers, matched for gender, education level, and vocabulary. We found no significant difference in performance between mid-aged and young-old groups, but the old-old group was significantly slower than the other two groups. The differences between the old-old group and the other groups combined were independently mediated by useful field of view (UFOV), contrast sensitivity, and simple reaction time measures. Given that hazard perception latency has been linked with increased crash risk, these results are consistent with the idea that increased crash risk in older adults could be a function of poorer hazard perception, though this decline does not appear to manifest until age 75+ in healthy drivers.
Resumo:
This paper presents the measurements of strain and the subsequent stress analysis on an in-service cast iron water main buried in reactive soil. The results indicate that the pipe crown experienced predominantly tensile stresses during drying in summer and, subsequently, these stresses reduce, eventually leading to compressive stresses as the soil swells with increase in moisture content with the approach of winter. It is also evident that flexural movement caused by thermal stresses and soil pressure has led to downward bending of the pipe in summer and subsequent upward movement in winter. The limited data collected from pipe strains and strengths indicate that it is possible for pipe capacity to be exceeded by thermal and soil stresses leading to pipe failure, provided the pipe has undergone significant corrosion.
Resumo:
Pure Tungsten Oxide (WO3) and Iron-doped (10 at%) Tungsten Oxide (WO3:Fe) nanostructured thin films were prepared using a dual crucible Electron Beam Evaporation techniques. The films were deposited at room temperature in high vacuum condition on glass substrate and post-heat treated at 300 oC for 1 hour. From the study of X-ray diffraction and Raman the characteristics of the as-deposited WO3 and WO3:Fe films indicated non-crystalline nature. The surface roughness of all the films showed in the order of 2.5 nm as observed using Atomic Force Microscopy (AFM). X-Ray Photoelectron Spectroscopy (XPS) analysis revealed tungsten oxide films with stoichiometry close to WO3. The addition of Fe to WO3 produced a smaller particle size and lower porosity as observed using Transmission Electron Microscopy (TEM). A slight difference in optical band gap energies of 3.22 eV and 3.12 eV were found between the as-deposited WO3 and WO3:Fe films, respectively. However, the difference in the band gap energies of the annealed films were significantly higher having values of 3.12 eV and 2.61 eV for the WO3 and WO3:Fe films, respectively. The heat treated samples were investigated for gas sensing applications using noise spectroscopy and doping of Fe to WO3 reduced the sensitivity to certain gasses. Detailed study of the WO3 and WO3:Fe films gas sensing properties is the subject of another paper.
Resumo:
This paper presents the findings of an investigation into the rate-limiting mechanism for the heterogeneous burning in oxygen under normal gravity and microgravity of cylindrical iron rods. The original objective of the work was to determine why the observed melting rate for burning 3.2-mm diameter iron rods is significantly higher in microgravity than in normal gravity. This work, however, also provided fundamental insight into the rate-limiting mechanism for heterogeneous burning. The paper includes a summary of normal-gravity and microgravity experimental results, heat transfer analysis and post-test microanalysis of quenched samples. These results are then used to show that heat transfer across the solid/liquid interface is the rate-limiting mechanism for melting and burning, limited by the interfacial surface area between the molten drop and solid rod. In normal gravity, the work improves the understanding of trends reported during standard flammability testing for metallic materials, such as variations in melting rates between test specimens with the same cross-sectional area but different crosssectional shape. The work also provides insight into the effects of configuration and orientation, leading to an improved application of standard test results in the design of oxygen system components. For microgravity applications, the work enables the development of improved methods for lower cost metallic material flammability testing programs. In these ways, the work provides fundamental insight into the heterogeneous burning process and contributes to improved fire safety for oxygen systems in applications involving both normal-gravity and microgravity environments.
Resumo:
Purpose: This two-part research project was undertaken as part of the planning process by Queensland Health (QH), Cancer Screening Services Unit (CSSU), Queensland Bowel Cancer Screening Program (QBCSP), in partnership with the National Bowel Cancer Screening Program (NBCSP), to prepare for the implementation of the NBCSP in public sector colonoscopy services in QLD in late 2006. There was no prior information available on the quality of colonoscopy services in Queensland (QLD) and no prior studies that assessed the quality of colonoscopy training in Australia. Furthermore, the NBCSP was introduced without extra funding for colonoscopy service improvement or provision for increases in colonoscopic capacity resulting from the introduction of the NBCSP. The main purpose of the research was to record baseline data on colonoscopy referral and practice in QLD and current training in colonoscopy Australia-wide. It was undertaken from a quality improvement perspective. Implementation of the NBCSP requires that all aspects of the screening pathway, in particular colonoscopy services for the assessment of positive Faecal Occult Blood Tests (FOBTs), will be effective, efficient, equitable and evidence-based. This study examined two important aspects of the continuous quality improvement framework for the NBCSP as they relate to colonoscopy services: (1) evidence-based practice, and (2) quality of colonoscopy training. The Principal Investigator was employed as Senior Project Officer (Training) in the QBCSP during the conduct of this research project. Recommendations from this research have been used to inform the development and implementation of quality improvement initiatives for provision of colonoscopy in the NBCSP, its QLD counterpart the QBCSP and colonoscopy services in QLD, in general. Methods – Part 1 Chart audit of evidence-based practice: The research was undertaken in two parts from 2005-2007. The first part of this research comprised a retrospective chart audit of 1484 colonoscopy records (some 13% of all colonoscopies conducted in public sector facilities in the year 2005) in three QLD colonoscopy services. Whilst some 70% of colonoscopies are currently conducted in the private sector, only public sector colonoscopy facilities provided colonoscopies under the NBCSP. The aim of this study was to compare colonoscopy referral and practice with explicit criteria derived from the National Health & Medical Research Council (NHMRC) (1999) Clinical Practice Guidelines for the Prevention, Early Detection and Management of Colorectal Cancer, and describe the nature of variance with the guidelines. Symptomatic presentations were the most common indication for colonoscopy (60.9%). These comprised per rectal bleeding (31.0%), change of bowel habit (22.1%), abdominal pain (19.6%), iron deficiency anaemia (16.2%), inflammatory bowel disease (8.9%) and other symptoms (11.4%). Surveillance and follow-up colonoscopies accounted for approximately one-third of the remaining colonoscopy workload across sites. Gastroenterologists (GEs) performed relatively more colonoscopies per annum (59.9%) compared to general surgeons (GS) (24.1%), colorectal surgeons (CRS) (9.4%) and general physicians (GPs) (6.5%). Guideline compliance varied with the designation of the colonoscopist. Compliance was lower for CRS (62.9%) compared to GPs (76.0%), GEs (75.0%), GSs (70.9%, p<0.05). Compliance with guideline recommendations for colonoscopic surveillance for family history of colorectal cancer (23.9%), polyps (37.0%) and a past history of bowel cancer (42.7%), was by comparison significantly lower than for symptomatic presentations (94.4%), (p<0.001). Variation with guideline recommendations occurred more frequently for polyp surveillance (earlier than guidelines recommend, 47.9%) and follow-up for past history of bowel cancer (later than recommended, 61.7%, p<0.001). Bowel cancer cases detected at colonoscopy comprised 3.6% of all audited colonoscopies. Incomplete colonoscopies occurred in 4.3% of audited colonoscopies and were more common among women (76.6%). For all colonoscopies audited, the rate of incomplete colonoscopies for GEs was 1.6% (CI 0.9-2.6), GPs 2.0% (CI 0.6-7.2), GS 7.0% (CI 4.8-10.1) and CRS 16.4% (CI 11.2-23.5). 18.6% (n=55) of patients with a documented family history of bowel cancer had colonoscopy performed against guidelines recommendations (for general (category 1) population risk, for reasons of patient request or family history of polyps, rather than for high risk status for colorectal cancer). In general, family history was inadequately documented and subsequently applied to colonoscopy referral and practice. Methods - Part 2 Surveys of quality of colonoscopy training: The second part of the research consisted of Australia-wide anonymous, self-completed surveys of colonoscopy trainers and their trainees to ascertain their opinions on the current apprenticeship model of colonoscopy in Australia and to identify any training needs. Overall, 127 surveys were received from colonoscopy trainers (estimated response rate 30.2%). Approximately 50% of trainers agreed and 27% disagreed that current numbers of training places were adequate to maintain a skilled colonoscopy workforce in preparation for the NBCSP. Approximately 70% of trainers also supported UK-style colonoscopy training within dedicated accredited training centres using a variety of training approaches including simulation. A collaborative approach with the private sector was seen as beneficial by 65% of trainers. Non-gastroenterologists (non-GEs) were more likely than GEs to be of the opinion that simulators are beneficial for colonoscopy training (χ2-test = 5.55, P = 0.026). Approximately 60% of trainers considered that the current requirements for recognition of training in colonoscopy could be insufficient for trainees to gain competence and 80% of those indicated that ≥ 200 colonoscopies were needed. GEs (73.4%) were more likely than non-GEs (36.2%) to be of the opinion that the Conjoint Committee standard is insufficient to gain competence in colonoscopy (χ2-test = 16.97, P = 0.0001). The majority of trainers did not support training either nurses (73%) or GPs in colonoscopy (71%). Only 81 (estimated response rate 17.9%) surveys were received from GS trainees (72.1%), GE trainees (26.3%) and GP trainees (1.2%). The majority were males (75.9%), with a median age 32 years and who had trained in New South Wales (41.0%) or Victoria (30%). Overall, two-thirds (60.8%) of trainees indicated that they deemed the Conjoint Committee standard sufficient to gain competency in colonoscopy. Between specialties, 75.4% of GS trainees indicated that the Conjoint Committee standard for recognition of colonoscopy was sufficient to gain competence in colonoscopy compared to only 38.5% of GE trainees. Measures of competency assessed and recorded by trainees in logbooks centred mainly on caecal intubation (94.7-100%), complications (78.9-100%) and withdrawal time (51-76.2%). Trainees described limited access to colonoscopy training lists due to the time inefficiency of the apprenticeship model and perceived monopolisation of these by GEs and their trainees. Improvements to the current training model suggested by trainees included: more use of simulation, training tools, a United Kingdom (UK)-style training course, concentration on quality indicators, increased access to training lists, accreditation of trainers and interdisciplinary colonoscopy training. Implications for the NBCSP/QBCSP: The introduction of the NBCSP/QBCSP necessitates higher quality colonoscopy services if it is to achieve its ultimate goal of decreasing the incidence of morbidity and mortality associated with bowel cancer in Australia. This will be achieved under a new paradigm for colonoscopy training and implementation of evidence-based practice across the screening pathway and specifically targeting areas highlighted in this thesis. Recommendations for improvement of NBCSP/QBCSP effectiveness and efficiency include the following: 1. Implementation of NBCSP and QBCSP health promotion activities that target men, in particular, to increase FOBT screening uptake. 2. Improved colonoscopy training for trainees and refresher courses or retraining for existing proceduralists to improve completion rates (especially for female NBCSP/QBCSP participants), and polyp and adenoma detection and removal, including newer techniques to detect flat and depressed lesions. 3. Introduction of colonoscopy training initiatives for trainees that are aligned with NBCSP/QBCSP colonoscopy quality indicators, including measurement of training outcomes using objective quality indicators such as caecal intubation, withdrawal time, and adenoma detection rate. 4. Introduction of standardised, interdisciplinary colonoscopy training to reduce apparent differences between specialties with regard to compliance with guideline recommendations, completion rates, and quality of polypectomy. 5. Improved quality of colonoscopy training by adoption of a UK-style training program with centres of excellence, incorporating newer, more objective assessment methods, use of a variety of training tools such as simulation and rotations of trainees between metropolitan, rural, and public and private sector training facilities. 6. Incorporation of NHMRC guidelines into colonoscopy information systems to improve documentation, provide guideline recommendations at the point of care, use of gastroenterology nurse coordinators to facilitate compliance with guidelines and provision of guideline-based colonoscopy referral letters for GPs. 7. Provision of information and education about the NBCSP/QBCSP, bowel cancer risk factors, including family history and polyp surveillance guidelines, for participants, GPs and proceduralists. 8. Improved referral of NBCSP/QBCSP participants found to have a high-risk family history of bowel cancer to appropriate genetics services.