901 resultados para INTERMITTENT HEMODIALYSIS
Resumo:
INTRODUCTION: Electroencephalography (EEG) has a central role in the outcome prognostication in subjects with anoxic/hypoxic encephalopathy following a cardiac arrest (CA). Continuous EEG monitoring (cEEG) has been consistently developed and studied; however, its yield as compared to repeated standard EEG (sEEG) is unknown. METHODS: We studied a prospective cohort of comatose adults treated with therapeutic hypothermia (TH) after a CA. cEEG data regarding background activity and epileptiform components were compared to two 20 minute sEEG extracted from the cEEG recording (one during TH, and one in early normothermia). RESULTS: In this cohort, 34 recordings were studied. During TH, the agreement between cEEG and sEEG was 97.1% (95% CI: 84.6 - 99.9%) for background discontinuity and reactivity evaluation, while it was 94.1% (95% CI 80.3 - 99.2%) regarding epileptiform activity. In early normothermia, we did not find any discrepancies. Thus, concordance was very good during TH (kappa 0.83), and optimal during normothermia (kappa=1). The median delay between CA and the first EEG reactivity testing was 18 hours (range: 4.75 - 25) for patients with perfect agreement and 10 hours (range: 5.75 - 10.5) for the three patients in whom there were discordant findings (P=0.02, Wilcoxon). CONCLUSION: Standard intermittent EEG has comparable performance than continuous EEG both for variables important for outcome prognostication (EEG reactivity) and identification of epileptiform transients in this relatively small sample of comatose survivors of CA. This finding has an important practical implication, especially for centers where EEG resources are limited.
Resumo:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.
Resumo:
Positive pressure ventilation (PPV) is a frequent intervention in the neonatal intensive care unit. This article is directed towards paediatricians in training and attempts to cover the basics of PPV without being too technical. To do so we have employed an extensive use of graphics to illustrate the underlying principles.
Resumo:
BACKGROUND: In a simulation based on a pharmacokinetic model we demonstrated that increasing the erythropoiesis stimulating agents (ESAs) half-life or shortening their administration interval decreases hemoglobin variability. The benefit of reducing the administration interval was however lessened by the variability induced by more frequent dosage adjustments. The purpose of this study was to analyze the reticulocyte and hemoglobin kinetics and variability under different ESAs and administration intervals in a collective of chronic hemodialysis patients. METHODS: The study was designed as an open-label, randomized, four-period cross-over investigation, including 30 patients under chronic hemodialysis at the regional hospital of Locarno (Switzerland) in February 2010 and lasting 2 years. Four subcutaneous treatment strategies (C.E.R.A. every 4 weeks Q4W and every 2 weeks Q2W, Darbepoetin alfa Q4W and Q2W) were compared with each other. The mean square successive difference of hemoglobin, reticulocyte count and ESAs dose was used to quantify variability. We distinguished a short- and a long-term variability based respectively on the weekly and monthly successive difference. RESULTS: No difference was found in the mean values of biological parameters (hemoglobin, reticulocytes, and ferritin) between the 4 strategies. ESAs type did not affect hemoglobin and reticulocyte variability, but C.E.R.A induced a more sustained reticulocytes response over time and increased the risk of hemoglobin overshooting (OR 2.7, p = 0.01). Shortening the administration interval lessened the amplitude of reticulocyte count fluctuations but resulted in more frequent ESAs dose adjustments and in amplified reticulocyte and hemoglobin variability. Q2W administration interval was however more favorable in terms of ESAs dose, allowing a 38% C.E.R.A. dose reduction, and no increase of Darbepoetin alfa. CONCLUSIONS: The reticulocyte dynamic was a more sensitive marker of time instability of the hemoglobin response under ESAs therapy. The ESAs administration interval had a greater impact on hemoglobin variability than the ESAs type. The more protracted reticulocyte response induced by C.E.R.A. could explain both, the observed higher risk of overshoot and the significant increase in efficacy when shortening its administration interval.Trial registrationClinicalTrials.gov NCT01666301.
Resumo:
Purpose: The accurate estimation of total energy expenditure (TEE) is essential to allow the provision of nutritional requirements in patients treated by maintenance hemodialysis (MHD). The measurement of TEE and resting energy expenditure (REE) by direct or indirect calorimetry and doubly labeled water are complicated, timeconsuming and cumbersome in this population. Recently, a new system called SenseWear® armband (SWA) was developed to assess TEE, physical activity and REE. This device works by measurements of body acceleration in two axes, heat production and steps counts. REE measured by indirect calorimetry and SWA are well correlated. The aim of this study was to determine TEE, physical activity and REE on patients on MHD using this new device. Methods and materials: Daily TEE, REE, step count, activity time, intensity of activity and lying time were determined for 7 consecutive days in unselected stable patients on MHD and sex, age and weightmatched healthy controls (HC). Patients with malnutrition, cancer, use of immunosuppressive drugs, hypoalbumemia <35 g/L and those hospitalized in the last 3 months, were excluded. For MHD patients, separate analyses were conducted in dialysis and non-dialysis days. Relevant parameters known to affect REE, such as BMI, albumin, pre-albumin, hemoglobin, Kt/V, CRP, bicarbonate, PTH, TSH, were recorded. Results: Thirty patients on MHD and 30 HC were included. In MHD patients, there were 20 men and 10 women. Age was 60,13 years ± 14.97 (mean ± SD), BMI was 25.77 kg/m² ± 4.73 and body weight was 74.65 kg ± 16.16. There were no significant differences between the two groups. TEE was lower in MHD patients compared to HC (28.79 ± 5.51 SD versus 32.91 ± 5.75 SD kcal/kg/day; p <0.01). Activity time was significantly lower in patients on MHD (101.3 ± 12.6SD versus 50.7 ± 9.4 SD min; p = 0.0021). Energy expenditure during the time of activity was significantly lower in MHD patients. MHD patients walked 4543 ± 643 SD vs 8537 ± 744 SD steps per day (p <0.0001). Age was negatively correlated with TEE (r = -0.70) and intensity of activity (r = -0.61) in HC, but not in patients on MHD. TEE showed no difference between dialysis and non-dialysis days (29.92 ± 2.03 SD versus 28.44 ± 1.90 SD kcal/kg/day; p = NS), reflecting a lack of difference in activity (number of steps, time of physical activity) and REE. This finding was observed in MHD patients both older and younger than 60 years. However, age stratification appeared to have an influence on TEE, regardless of dialysis day, (29.92 ± 2.07 SD kcal/kg/day for <60 years-old versus 27.41 ± 1.04 SD kcal/kg/day for ≥60 years old), although failing to reach statistical significance. Conclusion: Using SWA, we have shown that stable patients on MHD have a lower TEE than matched HC. On average, a TEE of 28.79 kcal/kg/day, partially affected by age, was measured. This finding gives support to the clinical impression that it is difficult and probably unnecessary to provide an energy amount of 30-35 kcal/kg/day, as proposed by international guidelines for this population. In addition, we documented for the first time that MHD patients exert a reduced physical activity as compared to HC. There were surprisingly no differences in TEE, REE and physical activity parameters between dialysis and non-dialysis days. This observation might be due to the fact that patients on MHD produce a physical effort to reach the dialysis centre. Age per se did not influence physical activity in MHD patients, contrary to HC, reflecting the impact of co-morbidities on physical activity in this group of patients.
Resumo:
We report the clinical and laboratory findings in two children with chronic mucocutaneous candidiasis (CMC) treated successfully with intermittent long-term ketoconazole therapy. Both had chronic infection of the nails, skin and mucous membranes with positive cultures for candida. Both were resistant to multiple local and systemic antifungal agents. After institution of ketoconazole therapy there was a dramatic improvement with clearing of the oral (one week), skin (two months) and nail lesions (5 months). After 8 months the drug was stopped and clinical remission persisted for 10 and 7 months respectively. Relapse of oral candidiasis was treated with a short course of ketoconazole (4-16 weeks) leading to complete healing of the lesions. Clinical improvement was not related to an amelioration in lymphocyte transformation. There was no change in the progressive deterioration of the lymphocyte responses to candida antigen which was probably due to persisting candida cell wall components (e.g. mannan).
Resumo:
INTRODUCTION: To compare the power spectral changes of the voluntary surface electromyogram (sEMG) and of the compound action potential (M wave) in the vastus medialis and vastus lateralis muscles during fatiguing contractions. METHODS: Interference sEMG and force were recorded during 48 intermittent 3-s isometric maximal voluntary contractions (MVC) from 13 young, healthy subjects. M waves and twitches were evoked using supramaximal femoral nerve stimulation between the successive MVCs. Mean frequency (F mean), and median frequency were calculated from the sEMG and M waves. Muscle fiber conduction velocity (MFCV) was computed by cross-correlation. RESULTS: The power spectral shift to lower frequencies was significantly greater for the voluntary sEMG than for the M waves (P < 0.05). Over the fatiguing protocol, the overall average decrease in MFCV (~25 %) was comparable to that of sEMG F mean (~22 %), but significantly greater than that of M-wave F mean (~9 %) (P < 0.001). The mean decline in MFCV was highly correlated with the mean decreases in both sEMG and M-wave F mean. CONCLUSIONS: The present findings indicated that, as fatigue progressed, central mechanisms could enhance the relative weight of the low-frequency components of the voluntary sEMG power spectrum, and/or the end-of-fiber (non-propagating) components could reduce the sensitivity of the M-wave spectrum to changes in conduction velocity.
Resumo:
Introduction: Chronic insufficiency alters homeostasis, in part due to endothelial inflammation. Plasminogen activator inhibitor-1 (PAI-1) is increased in renal disease, contributing to vascular damage. We assessed PAI-1 activity and PAI-1 4G/5G polymorphism in hemodialysis (HD) subjects and any association between thrombotic vascular access (VA) events and PAI-1 polymorphism. Methods: Prospective, observational study in 36 HD patients: mean age: 66.6 +/- 12.5 yr, males n=26 (72%), time on HD: 28.71 +/- 22.45 months. Vascular accesses: 10 polytetrafluoroethylene grafts (PTFEG), 22 arteriovenous fistulae (AVF), four dual lumen catheters (CAT). Control group (CG): 40 subjects; mean age: 60.0 +/- 15 yrs, males n=30 (75%). Group A (GA): thrombotic events (n=12), and group B (GB): No events (n=24). Groups were no different according to age (69.2 +/- 9.12 vs. 65.3 +/- 14.5 yrs), gender (males: 7; 58.3% vs. 18; 81.8%), time on HD (26.1 +/- 14.7 vs. 30.1 +/- 38.7 months), causes of renal failure. Time to follow-up, for access thrombosis: 12 months. Results: PAI-1 levels in HD: 7.21 +/- 2.13 vs. CG: 0.42 +/- 0.27 U/ml (p < 0.000 1). PAI-1 4G/5G polymorphic variant distribution in HD: 5G/5G: 6 (17%),4G/5G: 23 (64%); 4G/4G: 7 (19%) and in CG: 5G/5G: 14 (35%); 4G/5G: 18 (45%); 4G/4G: 8 (20%). C-reactive protein (CRP) in HD: 24.5 +/- 15.2 mg/L vs. in CG 2.3 +/- 0.2 mg/L (p < 0.0001). PAI-1 4G/5G variants: GA: 5G/5G: 3; 4G/5G: 8; 4G/4G: 1; GB: 5G/5G: 3; 4G/5G: 15; 4G/4G: 6. Thrombosis occurred in 8/10 patients (80%) with PTFEG, 3/22 (9%) in AVF, and 1/4 (25%) in CAT. Among the eight PTFEG patients with thrombosis, seven were PAI 4G/5G. Conclusions: PAI-1 levels were elevated in HD patients, independent of their polymorphic variants, 4G/5G being the most prevalent variant. Our data suggest that in patients with PTFEG the 4G/5G variant might be associated with an increased thrombosis risk.
Resumo:
Background: Our goal was to determine whether short-term intermittent hypoxia exposure, at a level well tolerated by healthy humans and previously shown by our group to increase EPO and erythropoiesis, could mobilizehematopoietic stem cells (HSC) and increase their presence in peripheral circulation. Methods: Four healthy male subjects were subjected to three different protocols: one with only a hypoxic stimulus (OH), another with a hypoxic stimulus plus muscle electrostimulation (HME) and the third with only muscle electrostimulation (OME). Intermittent hypobaric hypoxia exposureconsisted of only three sessions of three hours at barometric pressure 540 hPa (equivalent to an altitude of 5000 m) for three consecutive days, whereas muscular electrostimulation was performed in two separate periods of 25 min in each session. Blood samples were obtained from an antecubital vein on three consecutive days immediately before the experiment and 24 h, 48 h, 4 days and 7 days after the last day of hypoxic exposure. Results: There was a clear increase in the number of circulating CD34+ cells after combined hypobaric hypoxia and muscular electrostimulation. This response was not observed after the isolated application of the same stimuli. Conclusion: Our results open a new application field for hypobaric systems as a way to increase efficiency in peripheral HSC collection.
Resumo:
Background: Our goal was to determine whether short-term intermittent hypoxia exposure, at a level well tolerated by healthy humans and previously shown by our group to increase EPO and erythropoiesis, could mobilizehematopoietic stem cells (HSC) and increase their presence in peripheral circulation. Methods: Four healthy male subjects were subjected to three different protocols: one with only a hypoxic stimulus (OH), another with a hypoxic stimulus plus muscle electrostimulation (HME) and the third with only muscle electrostimulation (OME). Intermittent hypobaric hypoxia exposureconsisted of only three sessions of three hours at barometric pressure 540 hPa (equivalent to an altitude of 5000 m) for three consecutive days, whereas muscular electrostimulation was performed in two separate periods of 25 min in each session. Blood samples were obtained from an antecubital vein on three consecutive days immediately before the experiment and 24 h, 48 h, 4 days and 7 days after the last day of hypoxic exposure. Results: There was a clear increase in the number of circulating CD34+ cells after combined hypobaric hypoxia and muscular electrostimulation. This response was not observed after the isolated application of the same stimuli. Conclusion: Our results open a new application field for hypobaric systems as a way to increase efficiency in peripheral HSC collection.
Resumo:
Asthma and allergic rhinitis are chronic inflammatory airway diseases which often occur concomitantly. The objective of the LARA program was to identify the comorbidities and characteristics of asthma (A), intermittent or persistent rhinitis (IPR) and physician defined atopic dermatitis (AD) in 6- to 16-year old asthmatic Swiss children and adolescents. Overall, 126 general practitioners and paediatricians collected the data of 670 asthmatics. Approximately one third of the asthmatic children in Switzerland had well-controlled asthma. Almost two thirds of these asthmatics suffered from concomitant IPR. The latter presented with significantly less symptoms while the treatment rates with inhaled corticosteroids (approximately 90%) and leukotriene-receptorantagonists (approximately 50%) were comparable. However, there were almost twice as many passive smokers in the less well-controlled group. The prevalence of AD was similar in both groups. IPR and AD may play an important role as risk factors in the future development of asthma.