999 resultados para Humberto Mauro
Resumo:
A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.
Resumo:
The copper and cadmium complexation properties in natural sediment suspensions of reservoirs of the Tietê River were studied using the solid membrane copper and cadmium ion-selective electrodes. The complexation and the average conditional stability constants were determined under equilibrium conditions at pH=6.00 ± 0.05 in a medium of 1.0 mol L-1 sodium nitrate, using the Scatchard method. The copper and cadmium electrodes presented Nernstian behavior from 1x10-6 to 1x10-3 mol L-1 of total metal concentration. Scatchard graphs suggest two classes of binding sites for both metals. A multivariate study was done to correlate the reservoirs and the variables: complexation properties, size, total organic carbon, volatile acid sulfide, E II and pH.
Resumo:
Among the important changes in the production processes, it is necessary to guarantee the sustainability of the human enterprises, what makes us to foresee changes in the managerial administration to adapt to a new model, with the insert of the concepts of Clean Production, Cleaner, Lean and Total Productive Maintenance (TPM). The main focus of this work was to elaborate a methodology that made it possible to guarantee the reliability in the waterworks of the sugarcane harvester, identifying and analyzing the manners of flaws, in order to result in the improvement of the environmental and socioeconomic quality in the atmosphere of an industry of sugarcane through the significant decrease of hydraulic oil spill. Through the existent report in ERP (Enterprise Resource Planning), used in a Sugarcane Industry Plant, it was possible to accompany of the operational acting of the sugarcane harvester used during 03 crops, regarding the manners of flaws in the waterworks of the same ones, and, in one of the crops it was elaborated the total control of the waterworks of 5 harvesters. Based on the obtained data and the developed methodology it was possible to develop a software that specifies the electric outlet of decisions.
Resumo:
INTRODUCTION: Armies from all over the world acknowledge the importance of good physical fitness for the performance of military duties. The Military Exercise Training (MET) attempts to provide assistance to this search for better physical fitness and performance. OBJECTIVE: To verifying the effect on the body composition and physical performance of the students at ESPCEX (Military School for Preparation of Army Cadets) after 13 weeks of MET. METHODS: The sample was formed by 287 male students from the ESPCEX, whose average age was 18.33 ±1.26. Such students accomplished a boarding school routine, having defined schedules, meals and activities from which they were only released during the weekends. The MET was accomplished five days a week and it comprised both aerobic and resistance training. Measurement of body mass, height, skinfold (triceps, abdominal and suprailiac) was accomplished during pre and post training periods, and the following tests were performed: 12-minutes-run, oblique sit up, arm push up and pull up. Fat percentage, fat-free body mass and fat body mass were calculated using the anthropometric data based on the Guedes 3 skinfold protocol. RESULTS: Significant reduction in fat body mass, fat percentage and in triceptal and abdominal skinfold, as well as increase in suprailiac skinfold and fat-free body mass was observed when anthropometric and body composition data were compared, during the initial and the final periods of training. Significant improvement also occurred in all prformed physical tests, in which better performance was achieved. CONCLUSION: The acquired data suggest that performance of MET 5 days a week brought significantly improved body composition as well as physical performance
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Calcium phosphate salts, or more specifically hydroxyapatite, are products of great interest in the fields of medical and dental science due to their biocompatibility and osteoconduction property. Deproteinized xenografts are primarily constituted of natural apatites, sintered or not. Variations in the industrial process may affect physicochemical properties and, therefore, the biological outcome. The purpose of this work was to characterize the physical and chemical properties of deproteinized xenogenic biomaterials, Bio-Oss (Geistlich Biomaterials, Wolhuser, Switzerland) and Gen-Ox (Baumer S.A., Brazil), widely used as bone grafts. Scanning electron microscopy, infrared region spectroscopy, X-ray diffraction, thermogravimetry and degradation analysis were conducted. The results show that both materials presented porous granules, composed of crystalline hydroxyapatite without apparent presence of other phases. Bio-Oss presented greater dissolution in Tris-HCl than Gen-Ox in the degradation test, possibly due to the low crystallinity and the presence of organic residues. In conclusion, both commercial materials are hydroxyapatite compounds, Bio-Oss being less crystalline than Gen-Ox and, therefore, more prone to degradation.
Resumo:
This study evaluated comparatively the adhesion of Epiphany and AH Plus endodontic sealers to human root dentin treated with 1% NaOCl and 1% NaOCl+17% EDTA, using the push-out test. Sixty root cylinders obtained from maxillary canines had the canals prepared and were randomly assigned to 3 groups (n=20), according to root dentin treatment: GI - distilled water (control), GII - 1% NaOCl and GIII - 1% NaOCl+17% EDTA. Each group was divided into 2 subgroups (n=10) filled with either Epiphany or AH Plus. Bond strength push-out test data (kN) were obtained and analyzed statistically by ANOVA and Tukey's post-hoc test. There was statistically significant difference between sealers (AH Plus: 0.78 ± 0.13; Epiphany: 0.61 ± 0.19; p<0.01) and among root dentin treatments (distilled water: 0.58 ± 0.19; 1% NaOCl: 0.71 ± 0.12; 1% NaOCl+17% EDTA: 0.80 ± 0.17; p<0.05). In conclusion, AH Plus sealer presented greater adhesion to dentin than Epiphany, regardless of the treatment of root canal walls.
Resumo:
This study compared the coronal and apical leakage of AH Plus with gutta-percha to that of Epiphany with Resilon. Twenty-four single rooted teeth were instrumented and divided into 2 groups according to the solutions for smear layer removal and the obturation materials employed: Group A - 17% EDTA-T and AH Plus with gutta-percha; Group B - primer and Epiphany with Resilon. The Group B specimens were light-cured in the coronal area for 20 s. The external root surfaces were covered with a double layer of ethyl cyanoacrylate, except for the apical foramen and the cavity access. The teeth were immersed in 0.5% methylene blue for 48 h. The specimens were rinsed, dried and axially split for dye penetration measurement with the ImageLab 2.3 software. The t-test showed no significant differences for coronal leakage between the groups, but there were significant differences for apical leakage between the groups (P < 0.05). AH Plus with gutta-percha and Epiphany with Resilon provided the same coronal seal, whereas Epiphany with Resilon provided the best apical seal.
Resumo:
The aim of this study was to evaluate the bone repair using autogenous periosteum-derived cells (PDC) and bovine anorganic apatite and collagen (HA-COL). PDC from Wistar rats (n=10) were seeded on HA-COL discs and subjected to osteoinduction during 6 days. Critical-size defects in rat calvarias were treated with blood clot (G1), autogenous bone (G2), HA-COL (G3) and HA-COL combined with PDC (G4) (n=40), and then analyzed 1 and 3 months after surgeries. Radiographic analysis exhibited no significant temporal change. G1 and G2 had discrete new marginal bone, but the radiopacity of graft materials in G2, G3 and G4 impaired the detection of osteogenesis. At 3 months, histopathological analysis showed the presence of ossification islets in G1, which was more evident in G2, homogeneous new bone around HA-COL in G3 and heterogeneous new bone around HA-COL in G4 in addition to moderate presence of foreign body cells in G3 and G4. Histomorphometric analysis showed no change in the volume density of xenograft (p>0.05) and bone volume density in G2 was twice greater than in G1 and G4 after 3 months (p<0.05), but similar to G3. The PDC did not increase bone formation in vivo, although the biomaterial alone showed biocompatibility and osteoconduction capacity.
Resumo:
The objective of this work was to evaluate biaxial-flexural-strength (σf), Vickers hardness (HV), fracture toughness (K Ic), Young's modulus (E), Poisson's ratio (ν) and porosity (P) of two commercial glass-ceramics, Empress (E1) and Empress 2 (E2), as a function of the hot-pressing temperature. Ten disks were hot-pressed at 1065, 1070, 1075 and 1080 °C for E1; and at 910, 915, 920 and 925 °C for E2. The porosity was measured by an image analyzer software and s f was determined using the piston-on-three-balls method. K Ic and HV were determined by an indentation method. Elastic constants were determined by the pulse-echo method. For E1 samples treated at different temperatures, there were no statistical differences among the values of all evaluated properties. For E2 samples treated at different temperatures, there were no statistical differences among the values of σf, E, and ν, however HV and K Ic were significantly higher for 910 and 915 °C, respectively. Regarding P, the mean value obtained for E2 for 925 °C was significantly higher compared to other temperatures.
Resumo:
O objetivo deste estudo foi avaliar o efeito da contagem de células somáticas (CCS) do leite na atividade de plasmina e plasminogênio durante o período de armazenamento do leite longa vida integral. Os leites crus foram categorizados em grupos de CCS de baixa (342.000-487.000 células mL-1) e alta contagem (603.000-808.000 células mL-1). Dois lotes de leite longa vida em cada categoria de CCS foram analisados para determinação de plasmina e plasminogênio após 10, 30, 60, 90 e 120 dias de armazenamento em temperatura ambiente. Para a fabricação do leite longa vida, o leite cru foi submetido à pasteurização rápida seguida da esterilização industrial do leite por injeção de vapor pelo método direto e embalagem asséptica do produto. A CCS não apresentou efeitos sobre as características físico-químicas do leite cru, e nem sobre a atividade de plasmina e plasminogênio nos leites cru e longa vida, armazenados por 120 dias. Entretanto, independentemente da CCS, a atividade de plasmina e plasminogênio aumentou no leite longa vida ao longo do armazenamento, indicando a possibilidade de aumento da proteólise no produto durante sua vida de prateleira.
Resumo:
Avaliou-se a repetibilidade da mensuração de imagens de ultrassom da área do músculo longissimus dorsi (AOL) e das espessuras de gordura subcutânea do lombo (EGL) e da garupa (EGG). Imagens de ultrassom tomadas no lombo (entre a 12ª e a 13ª costela) e na garupa (entre os músculos gluteus medium e biceps femoris) de novilhas Nelore de 14 a 22 meses de idade foram classificadas em aceitáveis, marginais e rejeitáveis. As imagens aceitáveis e marginais foram mensuradas duas vezes por três técnicos em diferentes níveis de treinamento. Foram estimadas as repetibilidades entre e dentro de técnicos por classe de qualidade da imagem, para determinação do efeito da qualidade da imagem e do técnico no valor absoluto da diferença entre a primeira e a segunda mensuração dessas características. A repetibilidade para as imagens aceitáveis foi maior que para imagens marginais, tanto entre como dentro de técnicos. Na análise da diferença absoluta entre a primeira e a segunda interpretação, foram significativos os efeitos de técnico para AOL e EGL e de classe de qualidade da imagem para AOL. Em geral, o técnico com maior experiência apresentou maiores valores de repetibilidade. É recomendável que a mensuração de imagens de animais de mesmo grupo contemporâneo seja feita por um único técnico.
Resumo:
OBJETIVOS: o presente estudo radiográfico, retrospectivo e longitudinal objetivou determinar se a ancoragem do aparelho expansor fixo tipo Haas, modificado para as dentaduras decídua e mista, interfere na velocidade de rizólise e esfoliação dos caninos decíduos. MÉTODOS: foi feita uma avaliação quantitativa da rizólise do canino decíduo mediante a medição do comprimento coroa-ápice dos caninos decíduos superiores, dos lados direito e esquerdo. Para essa avaliação, 24 crianças submetidas à expansão rápida da maxila (ERM) na dentadura decídua ou no início da dentadura mista foram comparadas com 15 crianças que não passaram por esse procedimento. A medição do comprimento coroa-ápice dos caninos decíduos foi realizada com o programa computadorizado CEF-X Cefalometria Digital, produzido pela CDT Informática, que permitiu calibrar o tamanho dos dentes pela uniformização das imagens radiográficas digitalizadas. RESULTADOS: os dados estatísticos revelaram que não houve diferença na velocidade de rizólise dos caninos decíduos entre as crianças do grupo controle e as do grupo submetido à ERM. CONCLUSÕES: é possível inferir que o aparelho expansor fixo tipo Haas ancorado em dentes decíduos não influencia a rizólise dos caninos decíduos usados como ancoragem.
Resumo:
OBJETIVO: identificar alterações dimensionais nos arcos dentários superior e inferior na má oclusão Classe II, divisão 1, com deficiência mandibular (Padrão esquelético II). MÉTODOS: 48 pacientes com má oclusão Classe II, igualmente divididos quanto ao gênero, foram comparados com 51 indivíduos com oclusão normal, sendo 22 do gênero masculino e 29 do gênero feminino. Todos os 99 indivíduos estavam no estágio de dentadura permanente, com os segundos molares permanentes irrompidos ou em irrupção, com idade média de 12 anos e 5 meses (desvio-padrão de 1 ano e 3 meses), numa faixa etária oscilando entre 11 anos e 4 meses e 20 anos. CONCLUSÃO: os resultados permitem concluir que, na má oclusão Classe II, divisão 1 com deficiência mandibular, o arco dentário superior encontra-se alterado, mostrando-se atrésico e mais longo, enquanto o arco dentário inferior é pouco influenciado pela discrepância sagital de Classe II.