957 resultados para Human Error
Resumo:
Statement of the problem and public health significance. Hospitals were designed to be a safe haven and respite from disease and illness. However, a large body of evidence points to preventable errors in hospitals as the eighth leading cause of death among Americans. Twelve percent of Americans, or over 33.8 million people, are hospitalized each year. This population represents a significant portion of at risk citizens exposed to hospital medical errors. Since the number of annual deaths due to hospital medical errors is estimated to exceed 44,000, the magnitude of this tragedy makes it a significant public health problem. ^ Specific aims. The specific aims of this study were threefold. First, this study aimed to analyze the state of the states' mandatory hospital medical error reporting six years after the release of the influential IOM report, "To Err is Human." The second aim was to identify barriers to reporting of medical errors by hospital personnel. The third aim was to identify hospital safety measures implemented to reduce medical errors and enhance patient safety. ^ Methods. A descriptive, longitudinal, retrospective design was used to address the first stated objective. The study data came from the twenty-one states with mandatory hospital reporting programs which report aggregate hospital error data that is accessible to the public by way of states' websites. The data analysis included calculations of expected number of medical errors for each state according to IOM rates. Where possible, a comparison was made between state reported data and the calculated IOM expected number of errors. A literature review was performed to achieve the second study aim, identifying barriers to reporting medical errors. The final aim was accomplished by telephone interviews of principal patient safety/quality officers from five Texas hospitals with more than 700 beds. ^ Results. The state medical error data suggests vast underreporting of hospital medical errors to the states. The telephone interviews suggest that hospitals are working at reducing medical errors and creating safer environments for patients. The literature review suggests the underreporting of medical errors at the state level stems from underreporting of errors at the delivery level. ^
Resumo:
Medication errors, one of the most frequent types of medical errors, are a common cause of patient harm in hospital systems today. Nurses at the bedside are in a position to encounter many of these errors since they are there at the start of the process (ordering/prescribing) and the end of the process (administration). One of the recommendations from the IOM (Institute of Medicine) report, "To Err is Human," was for organizations to identify and learn from medical errors through event reporting systems. While many organizations have reporting systems in place, research studies report a significant amount of underreporting by nurses. A systematic review of the literature was performed to identify contributing factors related to the reporting and not reporting of medication errors by nurses at the bedside.^ Articles included in the literature review were primary or secondary studies, dated January 1, 2000 – July 2009, related to nursing medication error reporting. All 634 articles were reviewed with an algorithm developed to standardize the review process and help filter out those that did not meet the study criteria. In addition, 142 article bibliographies were reviewed to find additional studies that were not found in the original literature search.^ After reviewing the 634 articles and the additional 108 articles discovered in the bibliography review, 41 articles met the study criteria and were used in the systematic literature review results.^ Fear of punitive reactions to medication errors was a frequent barrier to error reporting. Nurses fear reactions from their leadership, peers, patients and their families, nursing boards, and the media. Anonymous reporting systems and departments/organizations with a strong safety culture in place helped to encourage the reporting of medication errors by nursing staff.^ Many of the studies included in this literature review do not allow results that can be generalized. The majority of them took place in single institutions/organizations with limited sample sizes. Stronger studies with larger sample sizes need to be performed, utilizing data collection methods that have been validated, to determine stronger correlations between safety cultures and nurse error reporting.^
Resumo:
Objective: This research is focused in the creation and validation of a solution to the inverse kinematics problem for a 6 degrees of freedom human upper limb. This system is intended to work within a realtime dysfunctional motion prediction system that allows anticipatory actuation in physical Neurorehabilitation under the assisted-as-needed paradigm. For this purpose, a multilayer perceptron-based and an ANFIS-based solution to the inverse kinematics problem are evaluated. Materials and methods: Both the multilayer perceptron-based and the ANFIS-based inverse kinematics methods have been trained with three-dimensional Cartesian positions corresponding to the end-effector of healthy human upper limbs that execute two different activities of the daily life: "serving water from a jar" and "picking up a bottle". Validation of the proposed methodologies has been performed by a 10 fold cross-validation procedure. Results: Once trained, the systems are able to map 3D positions of the end-effector to the corresponding healthy biomechanical configurations. A high mean correlation coefficient and a low root mean squared error have been found for both the multilayer perceptron and ANFIS-based methods. Conclusions: The obtained results indicate that both systems effectively solve the inverse kinematics problem, but, due to its low computational load, crucial in real-time applications, along with its high performance, a multilayer perceptron-based solution, consisting in 3 input neurons, 1 hidden layer with 3 neurons and 6 output neurons has been considered the most appropriated for the target application.
Resumo:
Services in smart environments pursue to increase the quality of people?s lives. The most important issues when developing this kind of environments is testing and validating such services. These tasks usually imply high costs and annoying or unfeasible real-world testing. In such cases, artificial societies may be used to simulate the smart environment (i.e. physical environment, equipment and humans). With this aim, the CHROMUBE methodology guides test engineers when modeling human beings. Such models reproduce behaviors which are highly similar to the real ones. Originally, these models are based on automata whose transitions are governed by random variables. Automaton?s structure and the probability distribution functions of each random variable are determined by a manual test and error process. In this paper, it is presented an alternative extension of this methodology which avoids the said manual process. It is based on learning human behavior patterns automatically from sensor data by using machine learning techniques. The presented approach has been tested on a real scenario, where this extension has given highly accurate human behavior models,
Resumo:
We have found that human organs such as colon, lung, and muscle, as well as their derived tumors, share nearly all mitochondrial hotspot point mutations. Seventeen hotspots, primarily G → A and A → G transitions, have been identified in the mitochondrial sequence of base pairs 10,030–10,130. Mutant fractions increase with the number of cell generations in a human B cell line, TK6, indicating that they are heritable changes. The mitochondrial point mutation rate appears to be more than two orders of magnitude higher than the nuclear point mutation rate in TK6 cells and in human tissues. The similarity of the hotspot sets in vivo and in vitro leads us to conclude that human mitochondrial point mutations in the sequence studied are primarily spontaneous in origin and arise either from DNA replication error or reactions of DNA with endogenous metabolites. The predominance of transition mutations and the high number of hotspots in this short sequence resembles spectra produced by DNA polymerases in vitro.
Resumo:
DNA polymerase η (Polη) functions in the error-free bypass of UV-induced DNA lesions, and a defect in Polη in humans causes the cancer-prone syndrome, the variant form of xeroderma pigmentosum. Both yeast and human Polη replicate through a cis-syn thymine-thymine dimer (TT dimer) by inserting two As opposite the two Ts of the dimer. Polη, however, is a low-fidelity enzyme, and it misinserts nucleotides with a frequency of ≈ 10−2 to 10−3 opposite the two Ts of the TT dimer as well as opposite the undamaged template bases. This low fidelity of nucleotide insertion seems to conflict with the role of Polη in the error-free bypass of UV lesions. To resolve this issue, we have examined the ability of human and yeast Polη to extend from paired and mispaired primer termini opposite a TT dimer by using steady-state kinetic assays. We find that Polη extends from mispaired primer termini on damaged and undamaged DNAs with a frequency of ≈ 10−2 to 10−3 relative to paired primer termini. Thus, after the incorporation of an incorrect nucleotide, Polη would dissociate from the DNA rather than extend from the mispair. The resulting primer-terminal mispair then could be subject to proofreading by a 3′→5′ exonuclease. Replication through a TT dimer by Polη then would be more accurate than that predicted from the fidelity of nucleotide incorporation alone.
Resumo:
Stroke is a prevalent disorder with immense socioeconomic impact. A variety of chronic neurological deficits result from stroke. In particular, sensorimotor deficits are a significant barrier to achieving post-stroke independence. Unfortunately, the majority of pre-clinical studies that show improved outcomes in animal stroke models have failed in clinical trials. Pre-clinical studies using non-human primate (NHP) stroke models prior to initiating human trials are a potential step to improving translation from animal studies to clinical trials. Robotic assessment tools represent a quantitative, reliable, and reproducible means to assess reaching behaviour following stroke in both humans and NHPs. We investigated the use of robotic technology to assess sensorimotor impairments in NHPs following middle cerebral artery occlusion (MCAO). Two cynomolgus macaques underwent transient MCAO for 90 minutes. Approximately 1.5 years following the procedure these NHPs and two non-stroke control monkeys were trained in a reaching task with both arms in the KINARM exoskeleton. This robot permits elbow and shoulder movements in the horizontal plane. The task required NHPs to make reaching movements from a centrally positioned start target to 1 of 8 peripheral targets uniformly distributed around the first target. We analyzed four movement parameters: reaction time, movement time (MT), initial direction error (IDE), and number of speed maxima to characterize sensorimotor deficiencies. We hypothesized reduced performance in these attributes during a neurobehavioural task with the paretic limb of NHPs following MCAO compared to controls. Reaching movements in the non-affected limbs of control and experimental NHPs showed bell-shaped velocity profiles. In contrast, the reaching movements with the affected limbs were highly variable. We found distinctive patterns in MT, IDE, and number of speed peaks between control and experimental monkeys and between limbs of NHPs with MCAO. NHPs with MCAO demonstrated more speed peaks, longer MTs, and greater IDE in their paretic limb compared to controls. These initial results qualitatively match human stroke subjects’ performance, suggesting that robotic neurobehavioural assessment in NHPs with stroke is feasible and could have translational relevance in subsequent human studies. Further studies will be necessary to replicate and expand on these preliminary findings.
Resumo:
Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This work presents a design of a non-invasive method using the registration between images from conventional Magnetic Resonance Imaging (MRI) and open MRI to calculate three dimensional hip joint kinematics. The method was tested on a single healthy subject in three different poses. MRI protocols for the conventional gantry, high-resolution MRI and the open gantry, lowresolution MRI were developed. The scan time for the low-resolution protocol was just under 6 minutes. High-resolution meshes and low resolution contours were derived from segmentation of the high-resolution and low-resolution images, respectively. Low-resolution contours described the poses as scanned, whereas the meshes described the bones’ geometries. The meshes and contours were registered to each other, and joint kinematics were calculated. The segmentation and registration were performed for both cortical and sub-cortical bone surfaces. A repeatability study was performed by comparing the kinematic results derived from three users’ segmentations of the sub-cortical bone surfaces from a low-resolution scan. The root mean squared error of all registrations was below 1.92mm. The maximum range between segmenters in translation magnitude was 0.95mm, and the maximum deviation from the average of all orientations was 1.27◦. This work demonstrated that this method for non-invasive measurement of hip kinematics is promising for measuring high-range-of-motion hip motions in vivo.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
This study examined whether the effectiveness of human resource management (HRM)practices is contingent on organizational climate and competitive strategy The concepts of internol and external fit suggest that the positive relationship between HRM and subsequent productivity will be stronger for firms with a positive organizational climate and for firms using differentiation strategies. Resource allocation theories of motivation, on the other hand, predict that the relationship between HRM and productivity will be stronger for firms with a poor climate because employees working in these firms should have the greatest amount of spare capacity. The results supported the resource allocation argument.
Resumo:
Background. To evaluate the haemodynamic features of young healthy myopes and emmetropes, in order to ascertain the perfusion profile of human myopia and its relationship with axial length prior to reaching a degenerative state. Methods The retrobulbar, microretinal and pulsatile ocular blood flow (POBF) of one eye of each of twenty-two high myopes (N=22, mean spherical equivalent (MSE) =-5.00D), low myopes (N=22, MSE-1.00 to-4.50D) and emmetropes (N=22, MSE±0.50D) was analyzed using color Doppler Imaging, Heidelberg retinal flowmetry and ocular blood flow analyser (OBF) respectively. Intraocular pressure, axial length (AL), systemic blood pressure, and body mass index were measured. Results. When compared to the emmetropes and low myopes, the AL was greater in high myopia (p<0.0001). High myopes showed higher central retinal artery resistance index (CRA RI) (p=0.004), higher peak systolic to end diastolic velocities ratio (CRA ratio) and lower end diastolic velocity (CRA EDv) compared to low myopes (p=0.014, p=0.037). Compared to emmetropes, high myopes showed lower OBFamplitude (OBFa) (p=0.016). The POBF correlated significantly with the systolic and diastolic blood velocities of the CRA (p=0.016, p=0.036). MSE and AL correlated negatively with OBFa (p=0.03, p=0.003), OBF volume (p=0.02, p<0.001), POBF (p=0.01, p<0.001) and positively with CRA RI (p=0.007, p=0.05). Conclusion. High myopes exhibited significantly reduced pulse amplitude and CRA blood velocity, the first of which may be due to an OBF measurement artefact or real decreased ocular blood flow pulsatility. Axial length and refractive error correlated moderately with the ocular pulse and with the resistance index of the CRA, which in turn correlated amongst themselves. It is hypothesized that the compromised pulsatile and CRA haemodynamics observed in young healthy myopes is an early feature of the decrease in ocular blood flow reported in pathological myopia. Such vascular features would increase the susceptibility for vascular and age-related eye diseases.
Resumo:
We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.
Resumo:
This research was concerned with identifying factors which may influence human reliability within chemical process plants - these factors are referred to as Performance Shaping Factors (PSFs). Following a period of familiarization within the industry, a number of case studies were undertaken covering a range of basic influencing factors. Plant records and site `lost time incident reports' were also used as supporting evidence for identifying and classifying PSFs. In parallel to the investigative research, the available literature appertaining to human reliability assessment and PSFs was considered in relation to the chemical process plan environment. As a direct result of this work, a PSF classification structure has been produced with an accompanying detailed listing. Phase two of the research considered the identification of important individual PSFs for specific situations. Based on the experience and data gained during phase one, it emerged that certain generic features of a task influenced PSF relevance. This led to the establishment of a finite set of generic task groups and response types. Similarly, certain PSFs influence some human errors more than others. The result was a set of error type key words, plus the identification and classification of error causes with their underlying error mechanisms. By linking all these aspects together, a comprehensive methodology has been forwarded as the basis of a computerized aid for system designers. To recapitulate, the major results of this research have been: One, the development of a comprehensive PSF listing specifically for the chemical process industries with a classification structure that facilitates future updates; and two, a model of identifying relevant SPFs and their order of priority. Future requirements are the evaluation of the PSF listing and the identification method. The latter must be considered both in terms of `useability' and its success as a design enhancer, in terms of an observable reduction in important human errors.
Resumo:
This thesis addresses the viability of automatic speech recognition for control room systems; with careful system design, automatic speech recognition (ASR) devices can be useful means for human computer interaction in specific types of task. These tasks can be defined as complex verbal activities, such as command and control, and can be paired with spatial tasks, such as monitoring, without detriment. It is suggested that ASR use be confined to routine plant operation, as opposed the critical incidents, due to possible problems of stress on the operators' speech. It is proposed that using ASR will require operators to adapt a commonly used skill to cater for a novel use of speech. Before using the ASR device, new operators will require some form of training. It is shown that a demonstration by an experienced user of the device can lead to superior performance than instructions. Thus, a relatively cheap and very efficient form of operator training can be supplied by demonstration by experienced ASR operators. From a series of studies into speech based interaction with computers, it is concluded that the interaction be designed to capitalise upon the tendency of operators to use short, succinct, task specific styles of speech. From studies comparing different types of feedback, it is concluded that operators be given screen based feedback, rather than auditory feedback, for control room operation. Feedback will take two forms: the use of the ASR device will require recognition feedback, which will be best supplied using text; the performance of a process control task will require task feedback integrated into the mimic display. This latter feedback can be either textual or symbolic, but it is suggested that symbolic feedback will be more beneficial. Related to both interaction style and feedback is the issue of handling recognition errors. These should be corrected by simple command repetition practices, rather than use error handling dialogues. This method of error correction is held to be non intrusive to primary command and control operations. This thesis also addresses some of the problems of user error in ASR use, and provides a number of recommendations for its reduction.