976 resultados para Heart valve diseases


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and objectives: The introduction of extracorporeal circulation in clinical practice was decisive for the development of modern cardiovascular surgery. Addition of new procedures and equipment, however, brings inherent risks and complications. The objective of this report is to describe a malfunction of the oxygenation system and emphasize the importance of the interaction among the medical team members to prevent errors and complications. Case Report: During valve replacement and IVC correction surgery, we observed a darker shade of red in the blood on the exit of the oxygenator. Laboratory tests demonstrated severe acidosis and hypoxemia. The entire system was evaluated, but the cause of the malfunction was not found. Measures to reduce damage were successfully instituted. After the surgery, the whole system underwent technical evaluation. Conclusions: Interaction among the medical team members, early diagnosis, and immediate intervention were fundamental for a favorable outcome. © 2011 Elsevier Editora Ltda.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introdução: Pacientes portadores de próteses valvares cardíacas mecânicas devem medicados continuamente com anticoagulantes orais para evitar acidentes tromboembólicos. Estes pacientes são avaliados continuamente para o controle da anticoagulação oral. Objetivo: Comparar a ocorrência de complicações tromboembólicas e hemorrágicas em portadores de próteses valvares cardíacas mecânicas de um (mono) e de dois (bi) folhetos na posição mitral em terapêutica anticoagulante. Métodos: Foram estudados, no intervalo de 10 anos, 117 pacientes portadores de prótese na posição mitral, sendo 48 com próteses de folheto único e 69 de folheto duplo. Avaliou-se a ocorrência de complicações tromboembólicas e hemorrágicas de grau maior e menor de acordo com a gravidade. Os resultados estão apresentados sob forma de estudo atuarial e de frequência linearizada de ocorrência de eventos. Resultados: As curvas atuariais mostraram que, ao longo do tempo, os pacientes portadores de próteses valvares monofolheto estiveram menos livres de complicações tromboembólicas que os pacientes com próteses bifolheto, enquanto que, estes últimos (bifolheto) estiveram menos livres de acidentes hemorrágicos. As frequências linearizadas de ocorrência para tromboembolismo foram maiores nos pacientes com próteses monofolheto. Nos episódios hemorrágicos as taxas foram maiores para os portadores de próteses bifolheto. Conclusão: Os portadores de próteses valvares cardíacas monofolheto mostraram-se mais propensos à ocorrência de acidentes tromboembólicos graves em relação aos com próteses bi folheto. Os pacientes com prótese bifolheto apresentaram maior sangramento que os pacientes com prótese monofolheto, no entanto, esta diferença se restringiu aos sangramentos de pouca gravidade.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Herein is reported the case of a patient who presented initially with aortic insufficiency and a fistula between the sinus of Valsalva and right atrium when aged 31 years. Closure of the fistula and replacement of the aortic valve with a Starr-Edwards A-9 caged-ball prosthesis was performed in 1972, since when the valve has survived for 40 years without dysfunction. This is one of the longest follow ups of the Starr-Edwards prosthesis reported, and highlights the possibility of acceptable valve performance over long periods of time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and aim of the study: The natriuretic peptides, brain natriuretic peptide (BNP) and its N-terminal prohormone (NT-proBNP), can be used as diagnostic and prognostic markers for aortic stenosis (AS). However, the association between BNP, NT-proBNP, and long-term clinical outcomes in patients with severe AS remains uncertain. Methods: A total of 64 patients with severe AS was prospectively enrolled into the study, and underwent clinical and echocardiographic assessments at baseline. Blood samples were drawn for plasma BNP and NT-proBNP analyses. The primary outcome was death from any cause, through a six-year follow up period. Cox proportional hazards modeling was used to examine the association between natriuretic peptides and long-term mortality, adjusting for important clinical factors. Results: During a mean period of 1,520 681 days, 51 patients (80%) were submitted to aortic valve replacement, and 13 patients (20%) were medically managed without surgical interventions. Mortality rates were 13.7% in the surgical group and 62% in the medically managed group (p <0.001). Patients with higher plasma BNP (>135 pg/ml) and NT-proBNP (>1,150 pg/ml) levels at baseline had a greater risk of long-term mortality (hazard ratio [HR] 3.2, 95% confidence interval [CI] 1.1-9.1; HR 4.3, 95% CI 1.4-13.5, respectively). After adjusting for important covariates, both BNP and NT-proBNP remained independently associated with long-term mortality (HR 2.9, 95%CI 1.5-5.7; HR 1.8, 95%CI 1.1-3.1, respectively). Conclusion: In patients with severe AS, plasma BNP and NT-proBNP levels were associated with long-term mortality. The use of these biomarkers to guide treatment might represent an interesting approach that deserves further evaluation. The Journal of Heart Valve Disease 2012;21:331-336

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: A via de acesso transfemoral é preferencial para o implante por cateter de bioprótese valvar aórtica. Entretanto, algumas situações, como a presença de doença vascular periférica, impossibilitam a utilização desse acesso. Nesses casos, o acesso por dissecção da artéria subclávia é uma alternativa para a realização do procedimento. Nosso objetivo foi avaliar a experiência brasileira com a utilização da artéria subclávia como via de acesso para o implante por cateter da bioprótese CoreValve®. MÉTODOS: Foram requisitos para o procedimento área valvar aórtica < 1 cm², ânulo valvar aórtico ≥ 20 mm e ≤ 27 mm (CoreValve® de 26 mm e 29 mm), aorta ascendente ≤ 43 mm e artéria subclávia com diâmetro ≥ 6 mm, isenta de lesões obstrutivas significativas, tortuosidade acentuada e calcificação excessiva. O acesso pela artéria subclávia foi obtido por dissecção cirúrgica e, sob visão direta, punção da artéria subclávia. Obtido o acesso arterial, empregou-se a técnica padrão. RESULTADOS: Entre janeiro de 2008 e abril de 2012, 8 pacientes com doença vascular periférica foram submetidos a implante de prótese CoreValve® pela artéria subclávia em 4 instituições. O procedimento foi realizado com sucesso em todos os casos, com redução do gradiente transvalvar aórtico médio de 46,4 ± 17,5 mmHg para 9,3 ± 3,6 mmHg (P = 0,0018) e melhora dos sintomas. Aos 30 dias e no seguimento de 275 ± 231 dias, 87,5% e 62,5% dos pacientes, respectivamente, apresentavam-se livres de complicações maiores (óbito, infarto do miocárdio, acidente vascular cerebral e cirurgia cardíaca de urgência). CONCLUSÕES: Na experiência brasileira, o acesso pela artéria subclávia mostrou-se seguro e eficaz como via alternativa para o implante por cateter da bioprótese CoreValve®.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lo scopo di questa tesi è lo sviluppo di una protesi valvolare sensorizzata per la valutazione e il monitoraggio dei parametri funzionali della valvola e di conseguenza la realizzazione un prototipo di PHV (Prosthetic Heart Valve) che integri all’interno delle protesi valvolari in commercio una tecnologia utile alla realizzazione di queste specifiche. Il segnale di impedenza intravalvolare (IVI) è ottenuto grazie ad un sistema di elettrodi utili alla generazione di un campo elettrico locale e alla successiva registrazione della differenza di potenziale. Il lavoro sperimentale è stato suddiviso in due parti: una prima parte deputata alla scelta della posizione ottimale degli elettrodi rispetto ai lembi, al piano e all’anello valvolare, al fine di determinare due prototipi, ed una seconda parte in cui sono stati testati i prototipi in una situazione più fisiologica, cioè in un tratto di aorta bovina, ed è stata simulata una dinamica valvolare alterata. Il maggior segnale di impedenza riscontrato è stato ottenuto ponendo gli elettrodi ortogonalmente al cardine dei lembi valvolari e sovrapponendo elettrodo di eccitazione e ricezione al fine di ottenere un campo elettrico costante e ricezione puntuale della variazione del campo. Infine è stato riscontrato che il segnale di impedenza intravalvolare è in grado di riflettere alterazioni simulate dei lembi.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: The primary objective of this nationwide survey carried out in department of cardiac anesthesia in Germany was to identify current practice with regard to neuromonitoring und neuroprotection. METHODOLOGY: The data are based on a questionnaire sent out to all departments of cardiac anesthesia in Germany between October 2007 und January 2008. The anonymized questionnaire contained 26 questions about the practice of preoperative evaluation of cerebral vessels, intra-operative use of neuromonitoring, the nature und application of cerebral protective measures, perfusion management during cardiopulmonary bypass, postoperative evaluation of neurological status, and training in the field of cerebral monitoring. RESULTS: Of the 80 mailed questionnaires 55% were returned and 90% of department evaluated cerebral vessels preoperatively with duplex ultrasound. The methods used for intra-operative neuromonitoring are electroencephalography (EEG, 60%) for type A dissections (38.1%), for elective surgery on the thoracic and thoraco-abdominal aorta (34.1% and 31.6%, respectively) and in carotid surgery (43.2%) near infrared spectroscopy (40%), evoked potentials (30%) and transcranial Doppler sonography (17.5%), with some centers using combined methods. In most departments the central nervous system is not subjected to monitoring during bypass surgery, heart valve surgery, or minimally invasive surgery. Cerebral protective measures used comprise patient cooling on cardio-pulmonary bypass (CPB 100%), extracorporeal cooling of the head (65%) and the administration of corticosteroids (58%), barbiturates (50%) and antiepileptic drugs (10%). Neuroprotective anesthesia consists of administering inhalation anesthetics (32.5%; sevoflurane 76.5%) and intravenous anesthesia (20%; propofol and barbiturates each accounting for 46.2%). Of the departments 72.5% cool patients as a standard procedure for surgery involving cardiovascular arrest and 37.5% during all surgery using CPB. In 84.6% of department CPB flow equals calculated cardiac output (CO) under normothermia, while the desired mean arterial pressure (MAP) varies between 60 and 70 mmHg (43.9%) and between 50 and 60 mmHg (41.5%), respectively. At body temperatures less than 18 degrees C CPB flow is reduced below the calculated CO (70%) while 27% of departments use normothermic flow rates. The preferred MAP under hypothermia is between 50 and 60 mmHg (59%). The results of intra-operative neuromonitoring are documented on the anesthesia record (77%). In 42.5% of the departments postoperative neurological function is estimated by the anesthesiologist. Continuing education sessions pertaining to neuromonitoring are organized on a regular basis in 32.5% of the departments and in 37.5% individual physicians are responsible for their own neuromonitoring education. CONCLUSION: The present survey data indicate that neuromonitoring and neuroprotective therapy during CPB is not standardized in cardiac anesthesiology departments in Germany. The systemic use of available methods to implement multimodal neuromonitoring would be desirable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Combined replacement of the aortic valve and ascending aorta using a composite graft represents the standard treatment for dilated aortic root with concomitant structural damage of the aortic valve, especially when the aortic valve cannot be preserved. Unfortunately, hemodynamic changes associated with prosthetic replacement of the aortic root have not been fully elucidated. The study aim was to compare hemodynamics within the replaced aortic root using either a prosthetic vascular graft with bulges mimicking the sinuses of Valsalva and including a stented pericardial valve, or a straight xenopericardial conduit and a stentless porcine valve. METHODS: Between July 2004 and March 2006, a total of 35 patients (mean age 65.2 years: range: 32-80 years) was enrolled into the present study. Aortic root replacement was performed in nine patients with a Valsalva graft (Gelweave Valsalva; Vascutek, Renfrewshire, UK) including a stented pericardial valve, and in 19 patients with a xenopericardial conduit containing a stentless porcine valve. All patients underwent postoperative magnetic resonance imaging (MRI). A control group of seven patients allowed for comparison with native aortic root hemodynamics. RESULTS: Maximum flow-velocity above the aortic valve as one marker of compliance of the aortic root was slightly higher in patients with a Valsalva graft compared to native aortic roots (1.9 m/s versus 1.3 m/s, p = 0.001), but was significantly lower than in patients with the xenopericardial graft without neo-sinuses (1.3 m/s versus 2.4 m/s, p < 0.001). CONCLUSION: The pre-shaped bulges in the prosthetic Valsalva graft effectively mimic the native sinuses of Valsalva, improve compliance of the aortic root, and result in a more physiologic flow pattern, as demonstrated by postoperative MRI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ace is an adhesin to collagen from Enterococcus faecalis expressed conditionally after growth in serum or in the presence of collagen. Here, we generated an ace deletion mutant and showed that it was significantly attenuated versus wild-type OG1RF in a mixed infection rat endocarditis model (P<0.0001), while no differences were observed in a peritonitis model. Complemented OG1RFDeltaace (pAT392::ace) enhanced early (4 h) heart valve colonization versus OG1RFDeltaace (pAT392) (P = 0.0418), suggesting that Ace expression is important for early attachment. By flow cytometry using specific anti-recombinant Ace (rAce) immunoglobulins (Igs), we showed in vivo expression of Ace by OG1RF cells obtained directly from infected vegetations, consistent with our previous finding of anti-Ace antibodies in E. faecalis endocarditis patient sera. Finally, rats actively immunized against rAce were less susceptible to infection by OG1RF than non-immunized (P = 0.0004) or sham-immunized (P = 0.0475) by CFU counts. Similarly, animals given specific anti-rAce Igs were less likely to develop E. faecalis endocarditis (P = 0.0001) and showed fewer CFU in vegetations (P = 0.0146). In conclusion, we have shown for the first time that Ace is involved in pathogenesis of, and is useful for protection against, E. faecalis experimental endocarditis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Includes bibliography.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective. Infective endocarditis (IE) is diagnosed by the Duke criteria, which can be inconclusive particularly when blood cultures are negative. This study investigated the application of polymerase chain reaction (PCR) to identify bacterial DNA in excised valvular tissue, and its role in establishing the diagnosis of IE. Methods. Ninety-eight patients undergoing valve replacement surgery were studied. Twenty-eight patients were confirmed as definite for endocarditis by the Duke criteria; nine were considered as possible and 61 had no known or previous microbial infection of the endocardium. A broad-range PCR technique was used to amplify prokaryotic 16S rRNA genes present within homogenised heart valve tissue. Subsequent DNA sequencing of the PCR amplicon allowed identification of the infecting microorganism. Results. PCR results demonstrated the presence of bacterial DNA in the heart valves obtained from 14 out of 20 (70%) definite IE patients with positive blood cultures preoperatively. The causative microorganism for one patient with definite culture negative endocarditis was identified by PCR. Two out of nine (22%) of the valves from possible endocarditis patients also had bacterial DNA present converting them into the definite criteria whereas in the valves of seven out of nine (78%) of these patients no bacterial DNA was detected. Conclusion. The application of PCR to the explanted valves in patients with possible or confirmed diagnosis can augment the Duke criteria thereby improving post-surgical antimicrobial therapeutic options. © 2003 The British Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bromocriptine is an ergot alkaloid dopamine D receptor agonist that has been used extensively in the past to treat hyperprolactinaemia, galactorrhoea and Parkinsonism. It is known that hypothalamic hypodopaminergic states and disturbed circadian rhythm are associated with the development of insulin resistance, obesity and diabetes in animals and humans. When administered in the early morning at the start of the light phase, a new quick release (QR) formulation of bromocriptine appears to act centrally to reset circadian rhythms of hypothalamic dopamine and serotonin and improve insulin resistance and other metabolic abnormalities. Phase II and III clinical studies show that QR-bromocriptine lowers glycated haemoglobin by 0.6-1.2% (7-13 mmol/mol) either as monotherapy or in combination with other antidiabetes medications. Apart from nausea, the drug is well tolerated. The doses used to treat diabetes (up to 4.8 mg daily) are much lower than those used to treat Parkinson's disease and have not been associated with retroperitoneal fibrosis or heart valve abnormalities. QR-bromocriptine (Cycloset™) has recently been approved in the USA for the treatment of type 2 diabetes mellitus (T2DM). Thus, a QR formulation of bromocriptine timed for peak delivery in the early morning may provide a novel neurally mediated approach to the control of hyperglycaemia in T2DM. © 2010 Blackwell Publishing Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mechanical conditioning has been shown to promote tissue formation in a wide variety of tissue engineering efforts. However the underlying mechanisms by which external mechanical stimuli regulate cells and tissues are not known. This is particularly relevant in the area of heart valve tissue engineering (HVTE) owing to the intense hemodynamic environments that surround native valves. Some studies suggest that oscillatory shear stress (OSS) caused by steady flow and scaffold flexure play a critical role in engineered tissue formation derived from bone marrow derived stem cells (BMSCs). In addition, scaffold flexure may enhance nutrient (e.g. oxygen, glucose) transport. In this study, we computationally quantified the i) magnitude of fluid-induced shear stresses; ii) the extent of temporal fluid oscillations in the flow field using the oscillatory shear index (OSI) parameter, and iii) glucose and oxygen mass transport profiles. Noting that sample cyclic flexure induces a high degree of oscillatory shear stress (OSS), we incorporated moving boundary computational fluid dynamic simulations of samples housed within a bioreactor to consider the effects of: 1) no flow, no flexure (control group), 2) steady flow-alone, 3) cyclic flexure-alone and 4) combined steady flow and cyclic flexure environments. We also coupled a diffusion and convention mass transport equation to the simulated system. We found that the coexistence of both OSS and appreciable shear stress magnitudes, described by the newly introduced parameter OSI-t , explained the high levels of engineered collagen previously observed from combining cyclic flexure and steady flow states. On the other hand, each of these metrics on its own showed no association. This finding suggests that cyclic flexure and steady flow synergistically promote engineered heart valve tissue production via OSS, so long as the oscillations are accompanied by a critical magnitude of shear stress. In addition, our simulations showed that mass transport of glucose and oxygen is enhanced by sample movement at low sample porosities, but did not play a role in highly porous scaffolds. Preliminary in-house in vitro experiments showed that cell proliferation and phenotype is enhanced in OSI-t environments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of medicinal plants to cure and treat various diseases is a common practice in the world and in Brazil. In several regions of the Brazil´s Northeast, the cactus Cereus jamacaru, known as mandacaru, is used popularly as a treatment to many diseases, including those related to heart respiratory diseases, gastric ulcers, scurvy, and kidney diseases. However, there is a scarcity in the scientific literature that proves scientifically the popular application of this cactus. Like other plants, Cereus jamacaru synthesizes several potentially bioactive molecules, like as polysaccharides. In this work, three polysaccharides-rich aqueous extracts, MCA80, MPM and MCP60, were obtained from this plant and analyzed chemically, as well as their cytotoxic and antioxidant potential. The data showed that all extracts consist mainly of polysaccharides (89.42 to 95.76%), but also protein (> 2%) and phenolic (3 to 8.87%) contaminants were detected. All extracts are rich in galactose, glucose and mannose. In addition, glucuronic acid was found in MCA80 and MCP60. The extracts showed total antioxidant capacity ranged from 55.21 to 68.13 of ascorbic acid equivalents (AAE). Besides, they exhibited reducer power and cupric chelation in a dose-dependent manner. None of the extracts inhibited the MTT reduction in the presence of prostate tumor cells (PC-3). However, MCP60 was the most effective extract by preventing the reduction of MTT by about 80% in the presence of cells 786. Nuclear fragmentation tests showed that this extract induces cell death. The data indicated that mandacaru synthesizes bioactive polysaccharides with potential as antioxidant and antitumor agents. For future studies, it is intended to purify and characterize these polysaccharides and its antioxidant and antitumor mechanisms

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mechanical conditioning has been shown to promote tissue formation in a wide variety of tissue engineering efforts. However the underlying mechanisms by which external mechanical stimuli regulate cells and tissues are not known. This is particularly relevant in the area of heart valve tissue engineering (HVTE) owing to the intense hemodynamic environments that surround native valves. Some studies suggest that oscillatory shear stress (OSS) caused by steady flow and scaffold flexure play a critical role in engineered tissue formation derived from bone marrow derived stem cells (BMSCs). In addition, scaffold flexure may enhance nutrient (e.g. oxygen, glucose) transport. In this study, we computationally quantified the i) magnitude of fluid-induced shear stresses; ii) the extent of temporal fluid oscillations in the flow field using the oscillatory shear index (OSI) parameter, and iii) glucose and oxygen mass transport profiles. Noting that sample cyclic flexure induces a high degree of oscillatory shear stress (OSS), we incorporated moving boundary computational fluid dynamic simulations of samples housed within a bioreactor to consider the effects of: 1) no flow, no flexure (control group), 2) steady flow-alone, 3) cyclic flexure-alone and 4) combined steady flow and cyclic flexure environments. We also coupled a diffusion and convention mass transport equation to the simulated system. We found that the coexistence of both OSS and appreciable shear stress magnitudes, described by the newly introduced parameter OSI-:τ: explained the high levels of engineered collagen previously observed from combining cyclic flexure and steady flow states. On the other hand, each of these metrics on its own showed no association. This finding suggests that cyclic flexure and steady flow synergistically promote engineered heart valve tissue production via OSS, so long as the oscillations are accompanied by a critical magnitude of shear stress. In addition, our simulations showed that mass transport of glucose and oxygen is enhanced by sample movement at low sample porosities, but did not play a role in highly porous scaffolds. Preliminary in-house in vitro experiments showed that cell proliferation and phenotype is enhanced in OSI-:τ: environments.^