832 resultados para Health-disesase process


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: The Texas Occupational Safety & Health Surveillance System (TOSHSS) was created to collect, analyze and interpret occupational injury and illness data in order to decrease the impact of occupational injuries within the state of Texas. This process evaluation was performed midway through the 4-year grant to assess the efficiency and effectiveness of the surveillance system’s planning and implementation activities1. ^ Methods: Two evaluation guidelines published by the Centers for Disease Control and Prevention (CDC) were used as the theoretical models for this process evaluation. The Framework for Program Evaluation in Public Health was used to examine the planning and design of TOSHSS using logic models. The Framework for Evaluating Public Health Surveillance Systems was used to examine the implementation of approximately 60 surveillance activities, including uses of the data obtained from the surveillance system. ^ Results/Discussion: TOSHSS planning activities omitted the creation of a scientific advisory committee and specific activities designed to maintain contacts with stakeholders; and proposed activities should be reassessed and aligned with ongoing performance measurement criteria, including the role of collaborators in helping the surveillance system achieve each proposed activity. TOSHSS implementation activities are substantially meeting expectations and received an overall score of 61% for all activities being performed. TOSHSS is considered a surveillance system that is simple, flexible, acceptable, fairly stable, timely, moderately useful, with good data quality and a PVP of 86%. ^ Conclusions: Through the third year of TOSHSS implementation, the surveillance system is has made a considerable contribution to the collection of occupational injury and illness information within the state of Texas. Implementation of the nine recommendations provided under this process evaluation is expected to increase the overall usefulness of the surveillance system and assist TDSHS in reducing occupational fatalities, injuries, and diseases within the state of Texas. ^ 1 Disclaimer: The Texas Occupational Safety and Health Surveillance System is supported by Grant/Cooperative Agreement Number (U60 OH008473-01A1). The content of the current evaluation are solely the responsibility of the authors and do not necessarily represent the official views of the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

On-orbit exposures can come from numerous factors related to the space environment as evidenced by almost 50 years of environmental samples collected for water analysis, air analysis, radiation analysis, and physiologic parameters. For astronauts and spaceflight participants the occupational exposures can be very different from those experienced by workers performing similar tasks in workplaces on Earth, because the duration of the exposure could be continuous for very long orbital, and eventually interplanetary, missions. The establishment of long-term exposure standards is vital to controlling the quality of the spacecraft environment over long periods. NASA often needs to update and revise its prior exposure standards (Spacecrafts Maximum Allowable Concentrations (SMACs)). Traditional standards-setting processes are often lengthy, so a more rapid method to review and establish standards would be a substantial advancement in this area. This project investigates use of the Delphi method for this purpose. ^ In order to achieve the objectives of this study a modified Delphi methodology was tested in three trials executed by doctoral students and a panel of experts in disciplines related to occupational safety and health. During each test/trial modifications were made to the methodology. Prior to submission of the Delphi Questionnaire to the panel of experts a pilot study/trial was conducted using five doctoral students with the goals of testing and adjusting the Delphi questionnaire to improve comprehension, work out any procedural issues and evaluate the effectiveness of the questionnaire in drawing the desired responses. The remainder of the study consisted of two trials of the Modified Delphi process using 6 chemicals that currently have the potential of causing occupational exposures to NASA astronauts or spaceflight participants. To assist in setting Occupational Exposure Limits (OEL), the expert panel was established consisting of experts from academia, government and industry. Evidence was collected and used to create close-ended questionnaires which were submitted to the Delphi panel of experts for the establishment of OEL values for three chemicals from the list of six originally selected (trial 1). Once the first Delphi trial was completed, adjustments were made to the Delphi questionnaires and the process above was repeated with the remaining 3 chemicals (trial 2). ^ Results indicate that experience in occupational safety and health and with OEL methodologies can have a positive effect in minimizing the time experts take in completing this process. Based on the results of the questionnaires and comparison of the results with the SMAC already established by NASA, we conclude that use of the Delphi methodology is appropriate for use in the decision-making process for the selection of OELs.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Queuing is one of the very important criteria for assessing the performance and efficiency of any service industry, including healthcare. Data Envelopment Analysis (DEA) is one of the most widely-used techniques for performance measurement in healthcare. However, no queue management application has been reported in the health-related DEA literature. Most of the studies regarding patient flow systems had the objective of improving an already existing Appointment System. The current study presents a novel application of DEA for assessing the queuing process at an Outpatients’ department of a large public hospital in a developing country where appointment systems do not exist. The main aim of the current study is to demonstrate the usefulness of DEA modelling in the evaluation of a queue system. The patient flow pathway considered for this study consists of two stages; consultation with a doctor and pharmacy. The DEA results indicated that waiting times and other related queuing variables included need considerable minimisation at both stages.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: The recently developed Context Assessment for Community Health (COACH) tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources, community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment) through 49 items. OBJECTIVE: The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. DESIGNS: To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test-retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC) and percent agreement) and dimensions (ICC and Bland-Altman plots). RESULTS: In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test-retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5-0.7), demonstrating that the instrument has an acceptable level of stability. CONCLUSIONS: This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify some items and to further review items with low ICC.