872 resultados para Hand-held devices
Resumo:
Ice loss from the marine-based, potentially unstable West Antarctic Ice Sheet (WAIS) contributes to current sea-level rise and may raise sea level by up to 3.3 to 5 meters in the future. Over the past few decades, glaciers draining the WAIS into the Amundsen Sea Embayment (ASE) have shown accelerated ice flow, rapid thinning and grounding-line retreat. However, the long-term context of this ice-sheet retreat is poorly constrained, limiting our ability to accurately predict future WAIS behaviour. Here we present a new chronology for WAIS retreat from the inner continental shelf of the eastern ASE based on radiocarbon dates from three marine sediment cores. The ages document a retreat of the grounding line to within ~93 km of its modern position before 11.7±0.7 kyr BP (thousand years before present). This early deglaciation is consistent with ages for grounding-line retreat from the western ASE. Our new data demonstrate that, other than in the Ross Sea, WAIS retreat in the ASE has not continued progressively since the Last Glacial Maximum. Furthermore, our results suggest that the grounding-line position in the ASE was predominantly stable throughout the Holocene, and that any episodes of fast retreat similar to that observed today must have been short-lived. Alternatively, today's rapid retreat was unprecedented during the Holocene. Therefore, the current ice loss must originate in recent changes in regional climate, ocean circulation or ice-sheet dynamics. Incorporation of these results into models is essential to produce robust predictions of future ice-sheet change and its contribution to sea-level rise.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
Objective: Transcranial Doppler (TCD) ultrasonography is a technique that uses a hand-held Doppler transducer (placed on the surface of the cranial skin) to measure the velocity and pulsatility of blood flow within the intracranial and the extracranial arteries. This review critically evaluates the evidence for the use of TCD in the critical care population. Discussion: TCD has been frequently employed for the clinical evaluation of cerebral vasospasm following subarachnoid haemorrhage (SAH). To a lesser degree, TCD has also been used to evaluate cerebral autoregulatory capacity, monitor cerebral circulation during cardiopulmonary bypass and carotid endarterectomies and to diagnose brain death. Technological advances such as M mode, colour Doppler and three-dimensional power Doppler ultrasonography have extended the scope of TCD to include other non-critical care applications including assessment of cerebral emboli, functional TCD and the management of sickle cell disease. Conclusions: Despite publications suggesting concordance between TCD velocity measurements and cerebral blood flow there are few randomized controlled studies demonstrating an improved outcome with the use of TCD monitoring in neurocritical care. Newer developments in this technology include venous Doppler, functional Doppler and use of ultrasound contrast agents.
Resumo:
Objective To assess the level of compliance with the new law in the United Kingdom mandating penalties for rising a hand held mobile phone while driving, to compare compliance with this law with the one on the use of seat belts, and to compare compliance with these laws between drivers of four wheel drive vehicles and drivers of normal cars. Design Observational study with two phases-one within the grace period, the other starting one week after penalties were imposed on drivers using such telephones. Setting Three busy sites in London. Participants Drivers of 38 182 normal cars and 2944 four wheel drive vehicles. Main outcome measures Proportions of drivers seen to be using hand held mobile phones and not using seat belts. Results Drivers of four wheel drive vehicles were more likely than drivers of other cars to be seen using hand held mobile phones (8.2% v 2.0%) and not complying with the law on seat belts (19.5% v 15.0%). Levels of non-compliance with both laws were slightly higher in the penalty phase of observation, and breaking one law was associated with increased likelihood of breaking the other. Conclusions The level of non-compliance with the law on the use of hand held mobile phones by drivers in London is high, as is non-compliance with the law on seat belts. Drivers of four wheel drive vehicles were four times more likely than drivers of other cars to be seen using hand held mobile phones and slightly more likely not to comply with the law on seat belts.
Resumo:
High speed twist drills are probably the most common of all metal cutting tools and also the least efficient. In this study, detailed research was undertaken into aspects of drill performance and ways in which drilling could be improved in short hole depths of up to two diameters. The work included an evaluation of twist drill geometry and grinding parameters. It was established that errors in point grinding lead to increased hole oversize and reduced drill life. A fundamental analysis was made to establish predictive equations for the drill torque and thrust using modified orthogonal cutting equations and empirical data. A good correlation was obtained between actual and predicted results. Two new techniques for extending twist drill life by the use of coolant feeding holes and also the application of titanium nitride coatings were evaluated. Both methods were found to have potential for improving drill performance. A completely new design of carbide tipped drill was designed and developed. The new design was tested and it compared favourably with two commercially available carbide tipped drills. In further work an entirely different type of drill point geometry was developed for the drill screw. A new design was produced which enabled the drilling time to be minimised for the low thrust forces that were likely to be used with hand held power tools.
Resumo:
We investigate the problem of obtaining a dense reconstruction in real-time, from a live video stream. In recent years, multi-view stereo (MVS) has received considerable attention and a number of methods have been proposed. However, most methods operate under the assumption of a relatively sparse set of still images as input and unlimited computation time. Video based MVS has received less attention despite the fact that video sequences offer significant benefits in terms of usability of MVS systems. In this paper we propose a novel video based MVS algorithm that is suitable for real-time, interactive 3d modeling with a hand-held camera. The key idea is a per-pixel, probabilistic depth estimation scheme that updates posterior depth distributions with every new frame. The current implementation is capable of updating 15 million distributions/s. We evaluate the proposed method against the state-of-the-art real-time MVS method and show improvement in terms of accuracy. © 2011 Elsevier B.V. All rights reserved.
Resumo:
There is an increasing pressure on university staff to provide ever more information and resources to students. This study investigated student opinions on (audio) podcasts and (video) vodcasts and how well they met requirements and aided learning processes. Two experiments within the Aston University looked at student opinion on, and usage of, podcasts and vodcasts for a selection of their psychology lectures. Recordings were produced first using a hand-held camcorder, and then using the in-house media department. WebCT was used to distribute the podcasts and vodcasts, attitude questionnaires were then circulated at two time points. Overall students indicated that podcasts and vodcasts were a beneficial addition resource for learning, particularly when used in conjunction with lecturers’ slides and as a tool for revision/assessment. The online material translated into students having increased understanding of the material, which supplemented and enhanced their learning without being a substitute for traditional lectures. There is scope for the provision of portable media files to become standard practice within higher education; integrating distance and online learning with traditional approaches to improve teaching and learning.
Resumo:
This dissertation is about the research carried on developing an MPS (Multipurpose Portable System) which consists of an instrument and many accessories. The instrument is portable, hand-held, and rechargeable battery operated, and it measures temperature, absorbance, and concentration of samples by using optical principles. The system also performs auxiliary functions like incubation and mixing. This system can be used in environmental, industrial, and medical applications. ^ Research emphasis is on system modularity, easy configuration, accuracy of measurements, power management schemes, reliability, low cost, computer interface, and networking. The instrument can send the data to a computer for data analysis and presentation, or to a printer. ^ This dissertation includes the presentation of a full working system. This involved integration of hardware and firmware for the micro-controller in assembly language, software in C and other application modules. ^ The instrument contains the Optics, Transimpedance Amplifiers, Voltage-to-Frequency Converters, LCD display, Lamp Driver, Battery Charger, Battery Manager, Timer, Interface Port, and Micro-controller. ^ The accessories are a Printer, Data Acquisition Adapter (to transfer the measurements to a computer via the Printer Port and expand the Analog/Digital conversion capability), Car Plug Adapter, and AC Transformer. This system has been fully evaluated for fault tolerance and the schemes will also be presented. ^
Resumo:
Instrumentation is a tool of fundamental importance for research in several areas of human knowledge. Research projects are often unfeasible when data cannot be obtained due to lack of instruments, especially due to impor ting difficulties and the high costs there associated. Thus, in order to collaborate with the enhancement of a national technology, a multiband hand - held sun p hotometer (FSM - 4) was developed to operate in the 500 nm, 670 nm, 870 nm and 940 nm bands. In the 500 nm, 670 nm and 870 nm bands aerosols are monitored for evaluation of the AOD (Aerosol Optical Depth), and the PWC (Precipitable Water Column) is evaluated in the 940 nm band. For the development of the mech anical and electronic parts for the FSM - 4, th e materials and componen ts should combine low cost and quality of the data collected. The calibration process utilized the Langley method (ML) and Modified Langley Method (MLM). These methods are usually applied at high altitudes in order to provide atmosp heric optical stability. This condition however can be found in low height sites as shown in the research by Liu et al. (2010). Thus, for calibration of the FSM - 4, we investigated the atmospher ic optical stability utilizing the ML and MLM at a site in the cit y of Caicó / RN, located in the s emiarid region in northeastern Brazil. This site lies in a region far aw ay from large urban centers and activities generating anthropogenic atmospheric pollution. Data for calibration of the prototype were collected usin g the FSM - 4 in two separate operations during the dry season, one in December 2012 and another in September 2013. The methodologies showed optical atmospheric instability in the studied region through the dispersion of the values obtained for the calibrati on constant. This dispersion is affected by the variability of AOD and PWC during the appl ication of the above mentioned methods . As an alternative to the descr ibed sun photometer calibration , a short study was performed using the sun photometer worldwide network AERONET/NASA (AERsol RObotic NETwork – US Space Agency), installed in Petrolina / PE in Brazil. Data were collected for three days utilizing the AERONET instruments and the FSM - 4, operating simultaneously on the same site. By way of the ML and MLM techniques, convergent test values were obtained for the calibration constants, despite the low amount of data collected. This calibration transfer methodology proved to be a viable alternative to the FSM - 4 calibration .