981 resultados para HPLC-UV-VIS


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The intension of this paper was to review and discuss some of the current quantitative analytical procedures which are used for quality control of pharmaceutical products. The selected papers were organized according to the analytical technique employed. Several techniques like ultraviolet/visible spectrophotometry, fluorimetry, titrimetry, electroanalytical techniques, chromatographic methods (thin-layer chromatography, gas chromatography and high-performance liquid chromatography), capillary electrophoresis and vibrational spectroscopies are the main techniques that have been used for the quantitative analysis of pharmaceutical compounds. In conclusion, although simple techniques such as UV/VIS spectrophotometry and TLC are still extensively employed, HPLC is the most popular instrumental technique used for the analysis of pharmaceuticals. Besides, a review of recent works in the area of pharmaceutical analysis showed a trend in the application of techniques increasingly rapid such as ultra performance liquid chromatography and the use of sensitive and specific detectors as mass spectrometers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Comparative HPLC-UV and LC-MS/MS studies of impurity profiles of a reference sample (Xenical®, F. Hoffmann-La Roche Ltd., Switzerland) vs. generic (Lipiblock®, EMS-Sigma Pharma, a generic drug) were carried out with ethanol extracts of commercial samples. The generic formulation contained higher levels of common impurities as well as a considerable number of impurities not found in the reference product. The detected impurity profile of Lipiblock® revealed that it most likely is based on fermentation. Since the effect of the impurities is unknown, at this point fully synthetic Xenical® appears to offer a better safety margin than Lipiblock® which, however, compares quite well to other generic formulations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The recovery of phenolic compounds of Eugenia pyriformis using different solvents was investigated in this study. The compounds were identified and quantified by reverse-phase high-performance liquid chromatography coupled with ultraviolet-visible diode-array detector (RP-HPLC-DAD/UV-vis). Absolute methanol was the most effective extraction agent of phenolic acids and flavonols (588.31 mg/Kg) from Eugenia pyriformis, although similar results (p ≤ 0.05) were observed using methanol/water (1:1 ratio). Our results clearly showed that higher contents of phenolic compounds were not obtained either with the most or the least polar solvents used. Several phenolic compounds were identified in the samples whereas gallic acid and quercetin were the major compounds recovered. © 2012 Association of Food Scientists & Technologists (India).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gastrotoxicity is a major problem for long-term therapy with non-steroidal anti-inflammatory drugs (NSAIDs). DICCIC (1-(2,6-dichlorophenyl)indolin-2-one) is a new diclofenac prodrug, which has proven anti-inflammatory activity without gastroulcerogenic effect. The aim of this work was to compare the pharmacokinetic profiles of diclofenac from DICCIC (7.6 mg/kg equivalent to 8.1 mg/kg diclofenac) and diclofenac (8.1 mg/kg) administration in Wistar rats weighing 250-300 g (n=20). The doses were calculated by interspecific allometric scaling based on the 2 mg/kg from diary human dose of diclofenac. Blood samples were collected in heparinized tubes via the femoral artery through the implanted catheter. The plasma was separated and quantitation was made in a HPLC system with a UV-Vis detector. The confidence limits of the bioanalytical method were appropriate for its application in a preclinical pharmacokinetic study. The AUC of diclofenac from DICCIC (53.7± 5.8 ug/mL.min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (885.9 ± 124,8 ug/mL.min). Terminal half-life of diclofenac from DICCIC (50.1 ± 17.2 min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (247.4 ± 100.9 min). Still the parameters clearance and distribution volume were calculated for diclofenac from diclofenac, whose results were 9.2 ±1.2 mL/min.kg and 3.3 ±1.2 L/kg, respectively. The results of DICCIC from DICCIC administration were 108.9 ± 19.6 mL/min.kg and 7.8 ± 2.4 L/kg for clearance and distribution volume, respectively. The pharmacokinetic profile demonstrated that there was an increase in diclofenac elimination and a lower exposure to diclofenac with administration of DICCIC compared to diclofenac. © 2013 Bentham Science Publishers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction Jatropha gossypifolia has been used quite extensively by traditional medicine for the treatment of several diseases in South America and Africa. This medicinal plant has therapeutic potential as a phytomedicine and therefore the establishment of innovative analytical methods to characterise their active components is crucial to the future development of a quality product. Objective To enhance the chromatographic resolution of HPLC-UV-diode-array detector (DAD) experiments applying chemometric tools. Methods Crude leave extracts from J. gossypifolia were analysed by HPLC-DAD. A chromatographic band deconvolution method was designed and applied using interval multivariate curve resolution by alternating least squares (MCR-ALS). Results The MCR-ALS method allowed the deconvolution from up to 117% more bands, compared with the original HPLC-DAD experiments, even in regions where the UV spectra showed high similarity. The method assisted in the dereplication of three C-glycosylflavones isomers: vitexin/isovitexin, orientin/homorientin and schaftoside/isoschaftoside. Conclusion The MCR-ALS method is shown to be a powerful tool to solve problems of chromatographic band overlapping from complex mixtures such as natural crude samples. Copyright © 2013 John Wiley & Sons, Ltd. Extracts from J. gossypifolia were analyzed by HPLC-DAD and, dereplicated applying MCR-ALS. The method assisted in the detection of three C-glycosylflavones isomers: vitexin/isovitexin, orientin/homorientin and schaftoside/isoschaftoside. The application of MCR-ALS allowed solving problems of chromatographic band overlapping from complex mixtures such as natural crude samples. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Indiscriminate and inappropriate use of pesticides in agriculture has been pointed out for increasing health problems and environmental damage. Considering that water resources are the principal destiny of those compounds after application, the present study presents optimization and validation of two simple and effi cient analytical methods for pesticides quantifi cation in both surface and groundwater. Were selected the pesticides more commonly used at Dourados (MS - Brazil), region with intense agricultural activity. Pesticides were preconcentrated by solid-phase extraction using C18 (500 mg) cartridges and then divided in two groups for elution and quantifi cation: 2.4-D and 2.4-DCP were eluted with methanol and quantifi ed by high performance liquid chromatography with ultra-violet detector (HPLC-UV) while atrazine, DIA, DEA, trifl uralin and methyl parathion were eluted with ethylacetate (1:1, v/v) and quantifi ed by gas chromatography with thermionic specifi c detector (GC-TSD). The methods showed satisfactory accuracy (76-107%) and precision (<12%) for the substances analyzed at the fortifi ed levels selected for the study, except for DIA (<51%). Study of pesticide stability also presented good results: C18 cartridges could be stored for at least for 21 days at -20ºC with no signs of the compounds degradability. Both methods limits of quantifi cation of the pesticides (0.22 - 0.48 μg L-1) are in accordance to the levels currently established by the Brazilian national legislation for pesticides in water. Although only the pesticide 2.4-D has been detected in two distinct collection points in the study period of time, this work warns for the requirement of systematical analysis of pesticides presence in water destined to human consume, principally in areas of intense agriculture activity. Such monitoring can provide subsidies for public environmental policies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstracts : The development of analytic methods more selective and sensitive is of great importance for a better quality in the determination of chemical species, therefore increasing the reliability of the results. In this way, the optimization of separation/concentration is still necessary. The use of Molecularly Imprinted Polymers - MIPs have demonstrated to be an efficient tool of analysis with a great potential in minimizing limitations of separation/concentration techniques traditionally employed. In general, the MIPs are obtained by polymerization in the presence of a template to be imprinted so that a polymeric skeleton is formed around the future analyte. In the present work, the template used is Estradiol Valerate (EV), compound used in the hormone replacement therapy (HRT) during climacteric. After the polymerization in bulk and in an anaerobic environment using MAA, EGDMA, AIBN, acetonitrile and VE, the obtained MIP was powdered, sifted (<120 μm) and placed in a soxhlet system containing ethanol at 60 °C, in order to remove the imprinted molecule through six successive washes in periods of 24 hours. The water used in the washings was analyzed using HPLC and spectrophotometry UV/Vis. Then, the obtained MIP was dried at room temperature and 150 mg was inset in SPE cartridges in order to evaluate the polymer's efficiency in the analyte pre-concentration and extraction. To do so, 100,0 mL of VE standard solution (2mg L-1) were pre-concentrated at 4,0 mL min-1 and eluted with 10,0 mL ethanol at 1,0 mL min-1, obtaining recoveries of 53%. Additionally, a NIP (non-imprinting polymer) was prepared to compare the obtained results, in which the recovery was 80%. In the same way, studies were conducted using commercial Strata™-X cartridges, obtaining 53% recovery. Since, the results did not reflect that than was expected, in relation with the MIP efficiency in the recovery, a computational ...