965 resultados para GRAFT FIXATION
Resumo:
Background: Lung transplant recipients are frequently exposed to respiratory viruses and are particularly at risk for severe complications. The aim of this study was to assess the association among the presence of a respiratory virus detected by molecular assays in bronchoalveolar lavage (BAL) fluid, respiratory symptoms, and acute rejection in adult lung transplant recipients. Methods: Upper (nasopharyngeal swab) and lower (BAL) respiratory tract specimens from 77 lung transplant recipients enrolled in a cohort study and undergoing bronchoscopy with BAL and transbronchial biopsies were screened using 17 different polymerase chain reaction-based assays. Result: BAL fluid and biopsy specimens from 343 bronchoscopic procedures performed in 77 patients were analyzed. We also compared paired nasopharyngeal and BAL fluid specimens collected in a subgroup of 283 cases. The overall viral positivity rate was 29.3% in the upper respiratory tract specimens and 17.2% in the BAL samples (). We observed a significant association P < .001 between the presence of respiratory symptoms and positive viral detection in the lower respiratory tract (Pp. 012). Conversely, acute rejection was not associated with the presence of viral infection (odds ratio, 0.41; 95% confidence interval, 0.20-0.88). The recovery of lung function was significantly slower when acute rejection and viral infection were both present. Conclusions: A temporal relationship exists between acute respiratory symptoms and positive viral nucleic acid detection in BAL fluid from lung transplant recipients. We provide evidence suggesting that respiratory viruses are not associated with acute graft rejection during the acute phase of infection.
Resumo:
Over the past few decades, Fourier transform infrared (FTIR) spectroscopy coupled to microscopy has been recognized as an emerging and potentially powerful tool in cancer research and diagnosis. For this purpose, histological analyses performed by pathologists are mostly carried out on biopsied tissue that undergoes the formalin-fixation and paraffin-embedding (FFPE) procedure. This processing method ensures an optimal and permanent preservation of the samples, making FFPE-archived tissue an extremely valuable source for retrospective studies. Nevertheless, as highlighted by previous studies, this fixation procedure significantly changes the principal constituents of cells, resulting in important effects on their infrared (IR) spectrum. Despite the chemical and spectral influence of FFPE processing, some studies demonstrate that FTIR imaging allows precise identification of the different cell types present in biopsied tissue, indicating that the FFPE process preserves spectral differences between distinct cell types. In this study, we investigated whether this is also the case for closely related cell lines. We analyzed spectra from 8 cancerous epithelial cell lines: 4 breast cancer cell lines and 4 melanoma cell lines. For each cell line, we harvested cells at subconfluence and divided them into two sets. We first tested the "original" capability of FTIR imaging to identify these closely related cell lines on cells just dried on BaF2 slides. We then repeated the test after submitting the cells to the FFPE procedure. Our results show that the IR spectra of FFPE processed cancerous cell lines undergo small but significant changes due to the treatment. The spectral modifications were interpreted as a potential decrease in the phospholipid content and protein denaturation, in line with the scientific literature on the topic. Nevertheless, unsupervised analyses showed that spectral proximities and distances between closely related cell lines were mostly, but not entirely, conserved after FFPE processing. Finally, PLS-DA statistical analyses highlighted that closely related cell lines are still successfully identified and efficiently distinguished by FTIR spectroscopy after FFPE treatment. This last result paves the way towards identification and characterization of cellular subtypes on FFPE tissue sections by FTIR imaging, indicating that this analysis technique could become a potential useful tool in cancer research.
Resumo:
PURPOSE: To describe methods and outcomes of excisional revision of a filtering bleb (bleb revision) using free conjunctival autologous graft either for bleb repair or for bleb reduction after trabeculectomy and deep sclerectomy with an implant. METHODS: Retrospective medical records were reviewed for a consecutive non-comparative case series comprising patients who underwent excisional revision of a filtering bleb between May 1998-January 2001. Excisional revision using free conjunctival autologous graft (bleb revision) was performed either for bleb repair, to treat early and late leaks and hypotony with maculopathy, or for bleb reduction, to improve ocular pain, discomfort, burning, foreign body sensation, tearing, and fluctuations of visual acuity. The revision consisted of bleb excision and free conjunctival autologous graft. The bleb histopathology was analyzed in patients who underwent bleb repair. RESULTS: Sixteen patients were included in the study, consisting of nine patients who had a trabeculectomy and seven patients who had a deep sclerectomy with an implant. Bleb revision was necessary in 14 patients due to leaking filtering bleb (bleb repair), and in 2 patients due to bleb dysesthesia (bleb reduction). After a follow-up of 15.1 +/- 8.4 months, the mean intraocular pressure (IOP) rose from 7.8 +/- 6.3 mm Hg to 14.3 +/- 6.5 mm Hg, and the visual acuity from 0.4 +/- 0.3 to 0.7 +/- 0.3, with a P value of 0.008 and 0.03, respectively. The complete success rate at 32 months, according to the Kaplan-Meier survival curve, was 38.3%, and the qualified success rate was 83.3%. Four patients (25%) required additional suturing for persistent bleb leak. To control IOP, antiglaucoma medical therapy was needed for six patients (37.5%) and repeated glaucoma surgery was needed for one patient. CONCLUSION: Free conjunctival autologous graft is a safe and successful procedure for bleb repair and bleb reduction. However, patients should be aware of the postoperative possibility of requiring medical or surgical intervention for IOP control after revision.
Resumo:
Partial trapeziectomy with suspension ligamentoplasty is a commonly performed treatment of thumb osteoarthritis. Nevertheless, the post-operative recovery remains long and critical reason for which different modifications of the surgical technique have been proposed. To compare two suspension ligamentoplasty techniques, one with a mitek anchor and another without, a retrospective study of 55 consecutive operated patients was performed. A detailed clinical analysis of pain, function and a radiologic assessment of the trapeziometacarpal space were performed. Mitek anchor fixation was associated with a shorter convalescence period. However, in spite of an improved radiological maintenance of the scaphometacarpal space, mitek anchor fixation was associated with an impaired postoperative function and residual pain when compared with the conventional suspension ligamentoplasty procedure. Patient's satisfaction was comparable in both groups. In our series stabilization of the suspension ligamentoplasty procedure by the insertion of a mitek anchor did not bring the hoped benefits to the patients with a trapeziometacarpal arthritis.
Resumo:
The genotypic differences on growth and yield of common bean (Phaseolus vulgaris L.) in response to P supply were evaluated in a field experiment under biological N2 fixation. Eight cultivars were grown at two levels of applied P (12 and 50 kg ha-1 of P -- P1 and P2 respectively), in randomized block design in factorial arrangement. Vegetative biomass was sampled at three ontogenetic stages. The effects of genotype and phosphorus were significant for most traits, but not the genotype ´ phosphorus interaction. The cultivars presented different patterns of biomass production and nutrient accumulation, particularly on root system. At P1, P accumulation persisted after the beginning of pod filling, and P translocation from roots to shoots was lower. The nodule senescence observed after flowering might have reduced N2 fixation during pod filling. The responses of vegetative growth to the higher P supply did not reflect with the same magnitude on yield, which increased only 6% at P2; hence the harvest index was lower at P2. The cultivars with highest yields also presented lower grain P concentrations. A sub-optimal supply of N could have limited the expression of the yield potential of cultivars, reducing the genotypic variability of responses to P levels.
Resumo:
BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic Repair Complications reported a total of 63 rAAD cases (incidence, 1.33%; 95% CI, 0.75 to 2.40). Eighty-one percent of patients underwent TEVAR for acute (n=26, 54%) or chronic type B dissection (n=13, 27%). Stent grafts with proximal bare springs were used in majority of patients (83%). Only 7 (15%) patients had intraoperative rAAD, with the remaining occurring during the index hospitalization (n=10, 21%) and during follow-up (n=31, 64%). Presenting symptoms included acute chest pain (n=16, 33%), syncope (n=12, 25%), and sudden death (n=9, 19%) whereas one fourth of patients were asymptomatic (n=12, 25%). Most patients underwent emergency (n=25) or elective (n=5) surgical repair. Outcome was fatal in 20 of 48 patients (42%). Causes of rAAD included the stent graft itself (60%), manipulation of guide wires/sheaths (15%), and progression of underlying aortic disease (15%). CONCLUSIONS: The incidence of rAAD was low (1.33%) in the present analysis with high mortality (42%). Patients undergoing TEVAR for type B dissection appeared to be most prone for the occurrence of rAAD. This complication occurred not only during the index hospitalization but after discharge up to 1050 days after TEVAR. Importantly, the majority of rAAD cases were associated with the use of proximal bare spring stent grafts with direct evidence of stent graft-induced injury at surgery or necropsy in half of the patients.
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
The aim of this work was to investigate the effect of water stress on N2 fixation and nodule structure of two common bean (Phaseolus vulgaris L.) cultivars Carioca and EMGOPA-201. Plants were harvested after five and eight days of water stress. Carioca had lower nodule dry weight on both water stress periods; shoot dry weight was lower at five days water stress and did not differ from control after eight days stress. Both cultivars had lower nitrogenase activity than control after five and eight days water stress. For both cultivars, after eight days stress bacteroid membranes were damaged. Carioca presented more pronounced damage to infected tissue, with host cell vacuolation and loss of the peribacteroid membrane at five days after stress; at eight days after stress, there was degradation of cytoplasm host cells and senescence of bacteroids, with their release into intercellular spaces. Intensity of immunogold-labeling of intercellular cortical glycoprotein with the monoclonal antibodies MAC 236/265 was different for both cultivars.