932 resultados para Fiber Reinforced Polymer
Resumo:
Estudi experimental del comportament de bigues de formigó armades amb barres de materials compostos de matriu polimèrica (FRP)
Resumo:
El present treball s’emmarca dins el camp de les estructures de formigó, i mésconcretament, a les que es troben reforçades amb armadures de materials compostos amb matriu polimèrica, és a dir FRP “Fiber Reinforced Polymer”
Resumo:
Due to frequent accidental damage to prestressed concrete (P/C) bridges caused by impact from overheight vehicles, a project was initiated to evaluate the strength and load distribution characteristics of damaged P/C bridges. A comprehensive literature review was conducted. It was concluded that only a few references pertain to the assessment and repair of damaged P/C beams. No reference was found that involves testing of a damaged bridge(s) as well as the damaged beams following their removal. Structural testing of two bridges was conducted in the field. The first bridge tested, damaged by accidental impact, was the westbound (WB) I-680 bridge in Beebeetown, Iowa. This bridge had significant damage to the first and second beams consisting of extensive loss of section and the exposure of numerous strands. The second bridge, the adjacent eastbound (EB) structure, was used as a baseline of the behavior of an undamaged bridge. Load testing concluded that a redistribution of load away from the damaged beams of the WB bridge was occurring. Subsequent to these tests, the damaged beams in the WB bridge were replaced and the bridge retested. The repaired WB bridge behaved, for the most part, like the undamaged EB bridge indicating that the beam replacement restored the original live load distribution patterns. A large-scale bridge model constructed for a previous project was tested to study the changes in behavior due to incrementally applied damage consisting initially of only concrete removal and then concrete removal and strand damage. A total of 180 tests were conducted with the general conclusion that for exterior beam damage, the bridge load distribution characteristics were relatively unchanged until significant portions of the bottom flange were removed along with several strands. A large amount of the total applied moment to the exterior beam was redistributed to the interior beam of the model. Four isolated P/C beams were tested, two removed from the Beebeetown bridge and two from the aforementioned bridge model. For the Beebeetown beams, the first beam, Beam 1W, was tested in an "as removed" condition to obtain the baseline characteristics of a damaged beam. The second beam, Beam 2W, was retrofit with carbon fiber reinforced polymer (CFRP) longitudinal plates and transverse stirrups to strengthen the section. The strengthened Beam was 12% stronger than Beam 1W. Beams 1 and 2 from the bridge model were also tested. Beam 1 was not damaged and served as the baseline behavior of a "new" beam while Beam 2 was damaged and repaired again using CFRP plates. Prior to debonding of the plates from the beam, the behavior of both Beams 1 and 2 was similar. The retrofit beam attained a capacity greater than a theoretically undamaged beam prior to plate debonding. Analytical models were created for the undamaged and damaged center spans of the WB bridge; stiffened plate and refined grillage models were used. Both models were accurate at predicting the deflections in the tested bridge and should be similarly accurate in modeling other P/C bridges. The moment fractions per beam were computed using both models for the undamaged and damaged bridges. The damaged model indicates a significant decrease in moment in the damaged beams and a redistribution of load to the adjacent curb and rail as well as to the undamaged beam lines.
Resumo:
Transverse joints are placed in portland cement concrete pavements to control the development of random cracking due to stresses induced by moisture and thermal gradients and restrained slab movement. These joints are strengthened through the use of load transfer devices, typically dowel bars, designed to transfer load across the joint from one pavement slab to the next. Epoxy coated steel bars are the materials of choice at the present time, but have experienced some difficulties with resistance to corrosion from deicing salts. The research project investigated the use of alternative materials, dowel size and spacing to determine the benefits and limitations of each material. In this project two types of fiber composite materials, stainless steel solid dowels and epoxy coated dowels were tested for five years in side by side installation in a portion of U.S. 65 near Des Moines, Iowa, between 1997 and 2002. The work was directed at analyzing the load transfer characteristics of 8-in. vs. 12-in. spacing of the dowels and the alternative dowel materials, fiber composite (1.5- and 1.88-in. diameter) and stainless steel (1.5-in. diameter), compared to typical 1.5-in. diameter epoxy-coated steel dowels placed on 12-in. spacing. Data were collected biannually within each series of joints and variables in terms of load transfer in each lane (outer wheel path), visual distress, joint openings, and faulting in each wheel path. After five years of performance the following observations were made from the data collected. Each of the dowel materials is performing equally in terms of load transfer, joint movement and faulting. Stainless steel dowels are providing load transfer performance equal to or greater than epoxy-coated steel dowels at the end of five years. Fiber reinforced polymer (FRP) dowels of the sizes and materials tested should be spaced no greater than 8 in. apart to achieve comparable performance to epoxy coated dowels. No evidence of deterioration due to road salts was identified on any of the products tested. The relatively high cost of stainless steel solid and FRP dowels was a limitation at the time of this study conclusion. Work is continuing with the subject materials in laboratory studies to determine the proper shape, spacing, chemical composition and testing specification to make the FRP and stainless (clad or solid) dowels a viable alternative joint load transfer material for long lasting portland cement concrete pavements.
Resumo:
As truck traffic on Iowa secondary roads has increased, engineers have moved to concrete pavements of greater depths. Early designs included thickened edge pavements and depths of seven inches or greater. The designs typically did not have load transfer devices installed in the transverse joints and relied on aggregate interlock for this purpose. In some cases, aggregate interlock was not adequate to deal with the soils and traffic conditions and faulting of the joints has begun to appear. Engineers are now faced with the need to install or retrofit load transfer in the joints to preserve the pavements. Questions associated with this decision range from the type of dowel material to dowel diameter, spacing, number of bars, placement method, and construction techniques to be used to assure reduction or elimination of faulting. Buena Vista County constructed a dowel bar retrofit project on one mile of road. The plan called for addition of the dowels (2, 3, or 4) in the outer wheel path only and surface grinding in lieu of asphalt overlay. The project included the application of elliptical- and round-shaped dowels in a rehabilitation project. Dowel material types included conventional epoxy-coated steel and fiber-reinforced polymer (FRP). This work involved the determination of relative costs in materials to be used in this type of work and performance of FRP and elliptical-shaped steel dowels in the retrofit work. The results indicate good performance from each of the bar configurations and use the results of ride and deflection testing over the research period to project the benefits that can be gained from each configuration vs. the anticipated construction costs. The reader is cautioned that this project could not relate the number of dowels required to the level of anticipated truck traffic for other roads that might be considered.
Resumo:
Many state, county, and local agencies are faced with deteriorating bridge infrastructure composed of a large percentage of relatively short to medium span bridges. In many cases, these older structures are rolled or welded longitudinal steel stringers acting compositely with a reinforced concrete deck. Most of these bridges, although still in service, need some level of strengthening due to increases in legal live loads or loss of capacity due to deterioration. Although these bridges are overstressed in most instances, they do not warrant replacement; thus, structurally efficient but cost-effective means of strengthening needs to be employed. In the past, the use of bolted steel cover plates or angles was a common retrofit option for strengthening such bridges. However, the time and labor involved to attach such a strengthening system can sometimes be prohibitive. This project was funded through the Federal Highway Administration’s Innovative Bridge Research and Construction program. The goal is to retrofit an existing structurally deficient, three-span continuous steel stringer bridge using an innovative technique that involves the application of post-tensioning forces; the post-tensioning forces were applied using fiber reinforced polymer post-tensioning bars. When compared to other strengthening methods, the use of carbon fiber reinforced polymer composite materials is very appealing in that they are highly resistant to corrosion, have a low weight, and have a high tensile strength. Before the post-tensioning system was installed, a diagnostic load test was conducted on the subject bridge to establish a baseline behavior of the unstrengthened bridge. During the process of installing the post-tensioning hardware and stressing the system, both the bridge and the post-tensioning system were monitored. The installation of the hardware was followed by a follow-up diagnostic load test to assess the effectiveness of the post-tensioning strengthening system. Additional load tests were performed over a period of two years to identify any changes in the strengthening system with time. Laboratory testing of several typical carbon fiber reinforced polymer bar specimens was also conducted to more thoroughly understand their behavior. This report documents the design, installation, and field testing of the strengthening system and bridge.
Resumo:
Diplomityö on tehty Exel Oyj:lle tuotekehityprojektina. Tarkoituksena on kehittää Exel Oyj:n valmistamaa komposiittipakkausrakennetta. Työssä on keskitytty valmistustekniseen selvitykseen komposiittirakenteen teollisen mittakaavan tuotannossa. Työssä selvitettiin erilaisten tuoterakenteiden valmistettavuutta sekä suoritettiin kyseisen tuotteen vaatimusprofiilin mukaisia testejä valituille rakennevaihtoehdoille. Pakkausrakenteelle asetettuja vaatimuksia ovat mm. kuljetusvaatimukset, jotka määräytyvät lähinnä NATO standardien pohjalta. Lisäksi tuotteelta vaaditaan tiettyä pitkäaikaiskestoa käsittelyn kannalta sekä soveltuvuutta vallitseviin ilmasto-olosuhteisiin. Vaatimusten mukaisia ominaisuuksia tutkittiin lisäksi mm. ballistisilla ja mekaanisilla testeillä sekä kaasuläpäisytesteillä. Testien pohjalta voidaan todeta, etteivät perinteisen alipaineinjektoidun komposiittituotteen ballistiset ominaisuudet ole riittävällä tasolla suojatuotetta ajatellen. Ballististen ja mekaanisten testien kesken havaittiin joitain yhtäläisyyksiä ja tämä vaikuttaa olevan nimenomaan mekaanisesti optimoidun komposiitin ominaisuus. DI-työn lopputuloksena on saatu selkeä kuva pakkausrakenteen materiaalivaihtoehtojen soveltuvuudesta kyseiselle tuotteelle. Lisäksi pakkausrakenteelle on ehdotettu neljä erilaista tuotesuunnitelmaan, niiden valmistustekniikat sekä lopputuotteen kustannusarviointi.
Resumo:
A/though steel is most commonly used as a reinforcing material in concrete due to its competitive cost and favorable mechanical properties, the problem of corrosion of steel rebars leads to a reduction in life span of the structure and adds to maintenance costs. Many techniques have been developed in recent past to reduce corrosion (galvanizing, epoxy coating, etc.) but none of the solutions seem to be viable as an adequate solution to the corrosion problem. Apart from the use of fiber reinforced polymer (FRP) rebars, hybrid rebars consisting of both FRP and steel are also being tried to overcome the problem of steel corrosion. This paper evaluates the performance of hybrid rebars as longitudinal reinforcement in normal strength concrete beams. Hybrid rebars used in this study essentially consist of glass fiber reinforced polymer (GFRP) strands of 2 mm diameter wound helically on a mild steel core of 6 mm diameter. GFRP stirrups have been used as shear reinforcement. An attempt has been made to evaluate the flexural and shear performance of beams having hybrid rebars in normal strength concrete with and without polypropylene fibers added to the concrete matrix
Resumo:
Ein großer Teil der Schäden wie auch der Verluste an Gesundheit und Leben im Erdbebenfall hat mit dem frühzeitigen Versagen von Mauerwerksbauten zu tun. Unbewehrtes Mauerwerk, wie es in vielen Ländern üblich ist, weist naturgemäß einen begrenzten Erdbebenwiderstand auf, da Zugspannungen und Zugkräfte nicht wie bei Stahlbeton- oder Stahlbauten aufgenommen werden können. Aus diesem Grund wurde bereits mit verschiedenen Methoden versucht, die Tragfähigkeit von Mauerwerk im Erdbebenfall zu verbessern. Modernes Mauerwerk kann auch als bewehrtes oder eingefasstes Mauerwerk hergestellt werden. Bei bewehrtem Mauerwerk kann durch die Bewehrung der Widerstand bei Beanspruchung als Scheibe wie als Platte verbessert werden, während durch Einfassung mit Stahlbetonelementen in erster Linie die Scheibentragfähigkeit sowie die Verbindung zu angrenzenden Bauteilen verbessert wird. Eine andere interessante Möglichkeit ist das Aufbringen textiler Mauerwerksverstärkungen oder von hochfesten Lamellen. In dieser Arbeit wird ein ganz anderer Weg beschritten, indem weiche Fugen Spannungsspitzen reduzieren sowie eine höhere Verformbarkeit gewährleiten. Dies ist im Erdbebenfall sehr hilfreich, da die Widerstandfähigkeit eines Bauwerks oder Bauteils letztlich von der Energieaufnahmefähigkeit, also dem Produkt aus Tragfähigkeit und Verformbarkeit bestimmt wird. Wenn also gleichzeitig durch die weichen Fugen keine Schwächung oder sogar eine Tragfähigkeitserhöhung stattfindet, kann der Erdbebenwiderstand gesteigert werden. Im Kern der Dissertation steht die Entwicklung der Baukonstruktion einer Mauerwerkstruktur mit einer neuartigen Ausbildung der Mauerwerksfugen, nämlich Elastomerlager und Epoxydharzkleber anstatt üblichem Dünnbettmörtel. Das Elastomerlager wird zwischen die Steinschichten einer Mauerwerkswand eingefügt und damit verklebt. Die Auswirkung dieses Ansatzes auf das Verhalten der Mauerwerkstruktur wird unter dynamischer und quasi-statischer Last numerisch und experimentell untersucht und dargestellt.
Resumo:
Estudi experimental del comportament de bigues de formigó armades amb barres de materials compostos de matriu polimèrica (FRP)
Resumo:
El present treball s’emmarca dins el camp de les estructures de formigó, i més concretament, a les que es troben reforçades amb armadures de materials compostos amb matriu polimèrica, és a dir FRP “Fiber Reinforced Polymer”
Resumo:
L'objectiu d'aquest projecte és el disseny dels bancs d'assaig necessaris per poder realitzar tres assajos de fisuració i deformació diferida al laboratori de resistència de materials de la UdG sobre provetes i bigues de formigó armat amb FRP i estudiar- ne el comportament. El primer assaig és el de fluència del formigó, on es sotmet una proveta a una compressió mantinguda en el temps. El segon assaig és un de tracció directa, on s'aplica una càrrega a tracció mantinguda en el temps en una proveta de formigó armat amb una barra FRP de reforç intern. El tercer és un assaig a flexió, on es carregarà una biga a flexió durant un període llarg de temps
Resumo:
Aquest treball final de carrera és un estudi del reforç d’un element estructural de formigó per mitjà de fibres FRP. Podem assimilar-lo a una guia pràctica per tal que un enginyer amb coneixements de construcció, pugui reforçar un membre que ha sofert danys produïts per aguantar càrregues, oscil·lacions, etc.per les que no havia estat dissenyat. El projecte conté teoria del FRP per tal de conèixer el material que utilitzarem pel nostre reforç, les normatives i prenormatives que s’utilitzen per fer el disseny, i un exemple pràctic de càlcul del reforç d’una biga sotmesa a flexió i el confinament d’un pilar, que són les dues opcions més utilitzades per reforçar amb FRP. El reforç d’estructures de formigó és el camp de la construcció on més ràpidament i amb major èxit s’estan aplicant els reforços amb FRP, degut a les propietats tant avantatjoses que presenten, entre altres, resistència a la corrosió i lleugeresa, que es tradueix en estalvi de transport i posada en obra
Resumo:
This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG