145 resultados para FLUOROSCOPY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE This study presents the first in vivo real-time optical tissue characterization during image-guided percutaneous intervention using near-infrared diffuse optical spectroscopy sensing at the tip of a needle. The goal of this study was to indicate transition boundaries from healthy tissue to tumors, namely, hepatic carcinoma, based on the real-time feedback derived from the optical measurements. MATERIALS AND METHODS Five woodchucks with hepatic carcinoma were used for this study. The woodchucks were imaged with contrast-enhanced cone beam computed tomography with a flat panel detector C-arm system to visualize the carcinoma in the liver. In each animal, 3 insertions were performed, starting from the skin surface toward the hepatic carcinoma under image guidance. In 2 woodchucks, each end point of the insertion was confirmed with pathologic examination of a biopsy sample. While advancing the needle in the animals under image guidance such as fluoroscopy overlaid with cone beam computed tomography slice and ultrasound, optical spectra were acquired at the distal end of the needles. Optical tissue characterization was determined by translating the acquired optical spectra into clinical parameters such as blood, water, lipid, and bile fractions; tissue oxygenation levels; and scattering amplitude related to tissue density. The Kruskal-Wallis test was used to study the difference in the derived clinical parameters from the measurements performed within the healthy tissue and the hepatic carcinoma. Kurtoses were calculated to assess the dispersion of these parameters within the healthy and carcinoma tissues. RESULTS Blood and lipid volume fractions as well as tissue oxygenation and reduced scattering amplitude showed to be significantly different between the healthy part of the liver and the hepatic carcinoma (P < 0.05) being higher in normal liver tissue. A decrease in blood and lipid volume fractions and tissue oxygenation as well as an increase in scattering amplitude were observed when the tip of the needle crossed the margin from the healthy liver tissue to the carcinoma. The kurtosis for each derived clinical parameter was high in the hepatic tumor as compared with that in the healthy liver indicating intracarcinoma variability. CONCLUSIONS Tissue blood content, oxygenation level, lipid content, and tissue density all showed significant differences when the needle tip was guided from the healthy tissue to the carcinoma and can therefore be used to identify tissue boundaries during percutaneous image-guided interventions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Air enema under fluoroscopy is a well-accepted procedure for the treatment of childhood intussusception. However, the reported radiation doses of pneumatic reduction with conventional fluoroscopy units have been high in decades past. OBJECTIVE To compare current radiation doses at our institution to past doses reported by others for fluoroscopic-guided pneumatic reduction of ileo-colic intussusception in children. MATERIALS AND METHODS Since 2007 radiologists and residents in our department who perform reduction of intussusceptions have received a radiation risk training. We retrospectively analyzed the data of 45 children (5 months-8 years) who underwent a total of 48 pneumatic reductions of ileo-colic intussusception between 2008 and 2012. We analyzed data for screening time and dose area product (DAP) and compared these data to those reported up to and including the year 2000. RESULTS Our mean screening time measured by the DAP-meter was 53.8 s (range 1-320 s, median 33.0 s). The mean DAP was 11.4 cGy ∙ cm(2) (range 1-145 cGy ∙ cm(2), median 5.45 cGy ∙ cm(2)). There was one bowel perforation, in a 1-year-old boy requiring surgical revision. Only three studies in the literature presented radiation exposure results on children who received pneumatic or hydrostatic reduction of intussusception under fluoroscopy. Screening times and dose area products in those studies, which were published in the 1990 s and in the year 2000, were substantially higher than those in our sample. CONCLUSION Low-frequency pulsed fluoroscopy and other dose-saving keys as well as the radiation risk training might have helped to improve the quality of the procedure in terms of radiation exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Closure of the patent foramen ovale does not benefit from echocardiographic guidance in the majority of cases. Guiding these procedures with fluoroscopy only reduces procedure time, radiation exposure, and amount of contrast medium. There is a clear trend to abandon echocardiographic guidance for this procedure over time and with growing experience.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Treatment of vascular malformations requires the placement of a needle within vessels which may be as small as 1 mm, with the current state of the art relying exclusively on two-dimensional fluoroscopy images for guidance. We hypothesize that the combination of stereotactic image guidance with existing targeting methods will result in faster and more reproducible needle placements, as well as reduced radiationexposure, when compared to standard methods based on fluoroscopy alone. METHODS The proposed navigation approach was evaluated in a phantom experiment designed to allow direct comparison with the conventional method. An anatomical phantom of the left forearm was constructed, including an independent control mechanism to indicate the attainment of the target position. Three interventionalists (one inexperienced, two of them frequently practice the conventional fluoroscopic technique) performed 45 targeting attempts utilizing the combined and 45 targeting attempts utilizing the standard approaches. RESULTS In all 45 attempts, the users were able to reach the target when utilizing the combined approach. In two cases, targeting was stopped after 15 min without reaching the target when utilizing only the C-arm. The inexperienced user was faster when utilizing the combined approach and applied significantly less radiation than when utilizing the conventional approach. Conversely, both experienced users were faster when using the conventional approach, in one case significantly so, with no significant difference in radiation dose when compared to the combined approach. CONCLUSIONS This work presents an initial evaluation of a combined navigation fluoroscopy targeting technique in a phantom study. The results suggest that, especially for inexperienced interventionalists, navigation may help to reduce the time and the radiation dose. Future work will focus on the improvement and clinical evaluation of the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tesis doctoral está encuadrada dentro del marco general de la ingeniería biomédica aplicada al tratamiento de las enfermedades cardiovasculares, enfermedades que provocan alrededor de 1.9 millones (40%) de muertes al año en la Unión Europea. En este contexto surge el proyecto europeo SCATh-Smart Catheterization, cuyo objetivo principal es mejorar los procedimientos de cateterismo aórtico introduciendo nuevas tecnologías de planificación y navegación quirúrgica y minimizando el uso de fluoroscopía. En particular, esta tesis aborda el modelado y diagnóstico de aneurismas aórticos abdominales (AAA) y del trombo intraluminal (TIL), allí donde esté presente, así como la segmentación de estas estructuras en imágenes preoperatorias de RM. Los modelos físicos específicos del paciente, construidos a partir de imágenes médicas preoperatorias, tienen múltiples usos, que van desde la evaluación preoperatoria de estructuras anatómicas a la planificación quirúrgica para el guiado de catéteres. En el diagnóstico y tratamiento de AAA, los modelos físicos son útiles a la hora de evaluar diversas variables biomecánicas y fisiológicas de las estructuras vasculares. Existen múltiples técnicas que requieren de la generación de modelos físicos que representen la anatomía vascular. Una de las principales aplicaciones de los modelos físicos es el análisis de elementos finitos (FE). Las simulaciones de FE para AAA pueden ser específicas para el paciente y permiten modelar estados de estrés complejos, incluyendo los efectos provocados por el TIL. La aplicación de métodos numéricos de análisis tiene como requisito previo la generación de una malla computacional que representa la geometría de interés mediante un conjunto de elementos poliédricos, siendo los hexaédricos los que presentan mejores resultados. En las estructuras vasculares, generar mallas hexaédricas es un proceso especialmente exigente debido a la compleja anatomía 3D ramificada. La mayoría de los AAA se encuentran situados en la bifurcación de la arteria aorta en las arterias iliacas y es necesario modelar de manera fiel dicha bifurcación. En el caso de que la sangre se estanque en el aneurisma provocando un TIL, éste forma una estructura adyacente a la pared aórtica. De este modo, el contorno externo del TIL es el mismo que el contorno interno de la pared, por lo que las mallas resultantes deben reflejar esta particularidad, lo que se denomina como "mallas conformadas". El fin último de este trabajo es modelar las estructuras vasculares de modo que proporcionen nuevas herramientas para un mejor diagnóstico clínico, facilitando medidas de riesgo de rotura de la arteria, presión sistólica o diastólica, etc. Por tanto, el primer objetivo de esta tesis es diseñar un método novedoso y robusto para generar mallas hexaédricas tanto de la pared aórtica como del trombo. Para la identificación de estas estructuras se utilizan imágenes de resonancia magnética (RM). Deben mantenerse sus propiedades de adyacencia utilizando elementos de alta calidad, prestando especial atención al modelado de la bifurcación y a que sean adecuadas para el análisis de FE. El método tiene en cuenta la evolución de la línea central del vaso en el espacio tridimensional y genera la malla directamente a partir de las imágenes segmentadas, sin necesidad de reconstruir superficies triangulares. Con el fin de reducir la intervención del usuario en el proceso de generación de las mallas, es también objetivo de esta tesis desarrollar un método de segmentación semiautomática de las distintas estructuras de interés. Las principales contribuciones de esta tesis doctoral son: 1. El diseño, implementación y evaluación de un algoritmo de generación de mallas hexaédricas conformadas de la pared y el TIL a partir de los contornos segmentados en imágenes de RM. Se ha llevado a cabo una evaluación de calidad que determine su aplicabilidad a métodos de FE. Los resultados demuestran que el algoritmo desarrollado genera mallas conformadas de alta calidad incluso en la región de la bifurcación, que son adecuadas para su uso en métodos de análisis de FE. 2. El diseño, implementación y evaluación de un método de segmentación automático de las estructuras de interés. La luz arterial se segmenta de manera semiautomática utilizando un software disponible a partir de imágenes de RM con contraste. Los resultados de este proceso sirven de inicialización para la segmentación automática de las caras interna y externa de la pared aórtica utilizando métodos basado en modelos de textura y forma a partir de imágenes de RM sin contraste. Los resultados demuestran que el algoritmo desarrollado proporciona segmentaciones fieles de las distintas estructuras de interés. En conclusión, el trabajo realizado en esta tesis doctoral corrobora las hipótesis de investigación postuladas, y pretende servir como aportación para futuros avances en la generación de modelos físicos de geometrías biológicas. ABSTRACT The frame of this PhD Thesis is the biomedical engineering applied to the treatment of cardiovascular diseases, which cause around 1.9 million deaths per year in the European Union and suppose about 40% of deaths per year. In this context appears the European project SCATh-Smart Catheterization. The main objective of this project is creating a platform which improves the navigation of catheters in aortic catheterization minimizing the use of fluoroscopy. In the framework of this project, the specific field of this PhD Thesis is the diagnosis and modeling of abdominal aortic aneurysm (AAAs) and the intraluminal thrombus (ILT) whenever it is present. Patient-specific physical models built from preoperative imaging are becoming increasingly important in the area of minimally invasive surgery. These models can be employed for different purposes, such as the preoperatory evaluation of anatomic structures or the surgical planning for catheter guidance. In the specific case of AAA diagnosis and treatment, physical models are especially useful for evaluating pressures over vascular structures. There are multiple techniques that require the generation of physical models which represent the target anatomy. Finite element (FE) analysis is one the principal applications for physical models. FE simulations for AAA may be patient-specific and allow modeling biomechanical and physiological variables including those produced by ILT, and also the segmentation of those anatomical structures in preoperative MR images. Applying numeric methods requires the generation of a proper computational mesh. These meshes represent the patient anatomy using a set of polyhedral elements, with hexahedral elements providing better results. In the specific case of vascular structures, generating hexahedral meshes is a challenging task due to the complex 3D branching anatomy. Each patient’s aneurysm is unique, characterized by its location and shape, and must be accurately represented for subsequent analyses to be meaningful. Most AAAs are located in the region where the aorta bifurcates into the iliac arteries and it is necessary to model this bifurcation precisely and reliably. If blood stagnates in the aneurysm and forms an ILT, it exists as a conforming structure with the aortic wall, i.e. the ILT’s outer contour is the same as the wall’s inner contour. Therefore, resulting meshes must also be conforming. The main objective of this PhD Thesis is designing a novel and robust method for generating conforming hexahedral meshes for the aortic wall and the thrombus. These meshes are built using largely high-quality elements, especially at the bifurcation, that are suitable for FE analysis of tissue stresses. The method accounts for the evolution of the vessel’s centerline which may develop outside a single plane, and generates the mesh directly from segmented images without the requirement to reconstruct triangular surfaces. In order to reduce the user intervention in the mesh generation process is also a goal of this PhD. Thesis to develop a semiautomatic segmentation method for the structures of interest. The segmentation is performed from magnetic resonance image (MRI) sequences that have tuned to provide high contrast for the arterial tissue against the surrounding soft tissue, so that we determine the required information reliably. The main contributions of this PhD Thesis are: 1. The design, implementation and evaluation of an algorithm for generating hexahedral conforming meshes of the arterial wall and the ILT from the segmented contours. A quality inspection has been applied to the meshes in order to determine their suitability for FE methods. Results show that the developed algorithm generates high quality conforming hexahedral meshes even at the bifurcation region. Thus, these meshes are suitable for FE analysis. 2. The design, implementation and evaluation of a semiautomatic segmentation method for the structures of interest. The lumen is segmented in a semiautomatic way from contrast filled MRI using an available software. The results obtained from this process are used to initialize the automatic segmentation of the internal and external faces of the aortic wall. These segmentations are performed by methods based on texture and shape models from MRI with no contrast. The results show that the algorithm provides faithful segmentations of the structures of interest requiring minimal user intervention. In conclusion, the work undertaken in this PhD. Thesis verifies the investigation hypotheses. It intends to serve as basis for future physical model generation of proper biological anatomies used by numerical methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: Durante procedimentos endovasculares, estão presentes os riscos relacionados ao uso dos contrastes iodados, tais como a nefropatia por contraste, uma vez que é fundamental o emprego de um meio de contraste para a obtenção das imagens radiológicas vasculares. A injeção intravascular de gás CO2 purificado é reconhecidamente uma alternativa relativamente mais segura ao contraste iodado, contudo, seu manuseio artesanal pode também trazer dificuldades técnicas e riscos aos pacientes. Para contemplar estas questões, foi desenvolvido o protótipo de um injetor intravascular de CO2 medicinal, microprocessado, dedicado à obtenção de imagens angiográficas. OBJETIVOS: Realizar os testes de viabilidade técnica inicial do protótipo em modelo in vivo. MÉTODOS: Realizar a angioplastia da artéria renal esquerda de 10 porcos, divididos em 2 grupos: Grupo 1 (n=5) injeção de contraste iodado, Grupo 2 (n=5) injeção de CO2 através do protótipo. Monitorização clínica e laboratorial dos animais no pré, intra e pós-operatório, com exames de função renal na véspera e 48h após os procedimentos e 3 gasometrias arteriais seriadas no intra-operatório. Observação clínica foi mantida por 48h no pós- operatório. RESULTADOS: Os procedimentos de angioplastia com CO2 foram realizados com sucesso técnico de 100%, sem necessidade de complementação com injeção de contraste iodado no Grupo 2. Não foram identificadas falhas no protótipo em funcionamento. Não foram identificadas alterações clínicas ou radiológicas sugestivas de contaminação por ar ambiente do sistema de CO2 e nem alterações laboratoriais nos animais. As imagens angiográficas obtidas no Grupo 2 foram consideradas, numa avaliação subjetiva, relativamente inferiores às imagens obtidas no Grupo 1. DISCUSSÃO: A qualidade inferior de imagem no Grupo 2 pode ser atribuída ao equipamento de fluoroscopia utilizado, com software desatualizado em relação aos equipamentos atuais, que incluem pré-configurações para angiografia com CO2; no entanto, ainda assim todos os procedimentos propostos no Grupo 2 foram realizados com sucesso técnico, o que nos leva a classificar as imagens deste grupo 2 como satisfatórias. O manuseio do aparelho mostrou-se ágil e eficiente, com a programação dos parâmetros sendo realizada com facilidade através do visor \"touch screen\", comparativamente superior ao método artesanal de injeção de CO2 com seringas em selo d\'água. CONCLUSÕES: O protótipo do aparelho injetor intravascular de CO2 funcionou de forma adequada durante os testes e as imagens obtidas permitiram a compleição com sucesso dos procedimentos. Portanto, os resultados positivos obtidos sugerem que o equipamento é tecnicamente viável

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Although a lowered medial longitudinal arch has been cited as a causal factor in plantar fasciitis, there is little experimental evidence linking arch motion to the pathogenesis of the condition. This study investigated the sagittal movement of the arch in subjects with and without plantar fasciitis during gait. Methods: Digital fluoroscopy was used to acquire dynamic lateral radiographs from 10 subjects with unilateral plantar fasciitis and 10 matched control subjects. The arch angle and the first metatarsophalangeal joint angle were digitized and their respective maxima recorded. Sagittal movement of the arch was defined as the angular change between heel strike and the maximum arch angle observed during the stance phase of gait. The-thickness of the proximal plantar fascia was determined from sagittal sonograms of both feet. ANOVA models were used to identify differences between limbs with respect to each dependent variable. Relationships between arch movement and fascial thickness were investigated using correlations. Results: There was no significant difference in either the movement or maximum arch angle between limbs. However, subjects with plantar fasciitis were found to have a larger metatarsophalangeal joint angle than controls (P < 0.05). Whereas the symptomatic and asymptomatic plantar fascia were thicker than those of control feet (P < 0.05), significant correlations were noted between fascial thickness and peak arch and metatarsophalangeal joint angles (P < 0.05) in the symptomatic limb only. Conclusions: Neither abnormal shape nor movement of the arch are associated with chronic plantar fasciitis. However, arch mechanics may influence the severity of plantar fasciitis once the condition is present. Digital flexion, in contrast, has a protective role in what might be a bilateral disease process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient's spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient's fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements. © 2013 Paolo Bifulco et al.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Oesophageal adenocarcinoma has increased dramatically in incidence over the past three decades with a particularly high burden of disease at the gastro-oesophageal junction. Many cases occur in individuals without known gastro-oesophageal reflux disease and in the absence of Barrett’s oesophagus suggesting that mechanisms other than traditional reflux may be important. Distal squamous mucosa may be prone to acid damage even in the absence of traditional reflux by the mechanism of distal opening of the lower oesophageal sphincter. This is splaying of the distal segment of lower oesophageal sphincter allowing acid ingress without traditional reflux. It has been suggested that the cardiac mucosa at the gastro-oesophageal junction, separating oesophageal squamous mucosa and acid secreting columnar mucosa of the stomach may be an abnormal mucosa arising as a consequence of acid damage. By this theory the cardiac mucosa is metaplastic and akin to ultra-short Barrett’s oesophagus. Obesity is a known risk factor for adenocarcinoma at the gastro-oesophageal junction and its rise has paralleled that of oesophageal cancer. Some of this excess risk undoubtedly operates through stress on the gastro-oesophageal junction and a predisposition to reflux. However we sought to explore the impact of obesity on the gastro-oesophageal junction in healthy volunteers without reflux and in particular to determine the characteristics of the cardiac mucosa and mechanisms of reflux in this group. Methods: 61 healthy volunteers with normal and increased waist circumference were recruited. 15 were found to have a hiatus hernia during the study protocol and were analysed separately. Volunteers had comprehensive pathological, physiological and anatomical assessments of the gastro-oesophageal junction including endoscopy with biopsies, MRI scanning before and after a standardised meal, prolonged recording of pH and manometry before and after a meal and screening by fluoroscopy to identify the squamo-columnar junction. In the course of the early manometric assessments a potential error associated with the manometry system recordings was identified. We therefore also sought to document and address this on the benchtop and in vivo. Key Findings: 1. In documenting the behaviour of the manoscan we described an immediate effect of temperature change on the pressure recorded by the sensors; ‘thermal effect’ and an ongoing drift of the recorded pressure with time; ‘baseline drift’. Thermal effect was well compensated within the standard operation of the system but baseline drift not addressed. Applying a linear correction to recorded data substantially reduced the error associated with baseline drift. 2. In asymptomatic healthy volunteers there was lengthening of the cardiac mucosa in association with central obesity and age. Furthermore, the cardiac mucosa in healthy volunteers demonstrated an almost identical immunophenotype to non-IM Barrett’s mucosa, which is considered to arise by metaplasia of oesophageal squamous mucosa. These findings support the hypothesis that the cardia is metaplastic in origin. 3. We have demonstrated a plausible mechanism of damage to distal squamous mucosa in association with obesity. In those with a large waist circumference we observed increased ingress of acid within but not across the lower oesophageal sphincter; ‘intrasphincteric reflux’ 4. The 15 healthy volunteers with a hiatus hernia were compared to 15 controls matched for age, gender and waist circumference. Those with a hiatus hernia had a longer cardiac mucosa and although they did not have excess traditional reflux they had excess distal acid exposure by short segment acid reflux and intrasphincteric acid reflux. Conclusions: These findings are likely to be relevant to adenocarcinoma of the gastro-oesophageal junction