Resumo:
UNLABELLED Altered arterial stiffness is a recognized risk factor of poor cardiovascular health. Chronic inflammation may increase arterial stiffness. We tested whether arterial stiffness is increased children with asthma, a chronic disease characterized by fluctuating airway and systemic inflammation. Arterial stiffness, expressed as carotid-femoral pulse wave velocity (PWVcf), was measured in 37 mild-to-moderate asthmatic children: 11 girls, median (range) age 11.1 years (6-15). PWVcf in asthma was compared to PWVcf in 65 healthy controls matched for age, height, and gender previously studied in Germany and was correlated with airway inflammation and obstruction. PWVcf was higher in asthmatic children compared to controls: PWVcf median (interquartile range) was 4.7 m/s (4.5-4.9) vs. 4.3 m/s (4.1-4.7), p < 0.0001. In asthmatic children, PWVcf was inversely associated (r (2) = 0.20, p = 0.004) with forced expiratory volume in 1 s (FEV1). This association remained significant after adjusting for possible confounders including body mass index, blood pressure, steroid use, and FeNO. CONCLUSION Arterial stiffness is increased in children with mild-to-moderate asthma. The association between impaired lung function and increased arterial stiffness suggests that severity of disease translates into detrimental effects on the cardiovascular system.
Resumo:
OBJECTIVES The importance of phrenic nerve preservation during pneumonectomy remains controversial. We previously demonstrated that preservation of the phrenic nerve in the immediate postoperative period preserved lung function by 3-5% but little is known about its long-term effects. We, therefore, decided to investigate the effect of temporary ipsilateral cervical phrenic nerve block on dynamic lung volumes in mid- to long-term pneumonectomy patients. METHODS We investigated 14 patients after a median of 9 years post pneumonectomy (range: 1-15 years). Lung function testing (spirometry) and fluoroscopic and/or sonographic assessment of diaphragmatic motion on the pneumonectomy side were performed before and after ultrasonographic-guided ipsilateral cervical phrenic nerve block by infiltration with lidocaine. RESULTS Ipsilateral phrenic nerve block was successfully achieved in 12 patients (86%). In the remaining 2 patients, diaphragmatic motion was already paradoxical before the nerve block. We found no significant difference on dynamic lung function values (FEV1 'before' 1.39 ± 0.44 vs FEV1 'after' 1.38 ± 0.40; P = 0.81). CONCLUSIONS Induction of a temporary diaphragmatic palsy did not significantly influence dynamic lung volumes in mid- to long-term pneumonectomy patients, suggesting that preservation of the phrenic nerve is of greater importance in the immediate postoperative period after pneumonectomy.
Resumo:
Pulmonary exacerbations are important clinical events for cystic fibrosis (CF) patients. Studies assessing the ability of the lung clearance index (LCI) to detect treatment response for pulmonary exacerbations have yielded heterogeneous results. Here, we conduct a retrospective analysis of pooled LCI data to assess treatment with intravenous antibiotics for pulmonary exacerbations and to understand factors explaining the heterogeneous response.A systematic literature search was performed to identify prospective observational studies. Factors predicting the relative change in LCI and spirometry were evaluated while adjusting for within-study clustering.Six previously reported studies and one unpublished study, which included 176 pulmonary exacerbations in both paediatric and adult patients, were included. Overall, LCI significantly decreased by 0.40 units (95% CI -0.60- -0.19, p=0.004) or 2.5% following treatment. The relative change in LCI was significantly correlated with the relative change in forced expiratory volume in 1 s (FEV1), but results were discordant in 42.5% of subjects (80 out of 188). Higher (worse) baseline LCI was associated with a greater improvement in LCI (slope: -0.9%, 95% CI -1.0- -0.4%).LCI response to therapy for pulmonary exacerbations is heterogeneous in CF patients; the overall effect size is small and results are often discordant with FEV1.
Resumo:
BACKGROUND Children born preterm or with a small size for gestational age are at increased risk for childhood asthma. OBJECTIVE We sought to assess the hypothesis that these associations are explained by reduced airway patency. METHODS We used individual participant data of 24,938 children from 24 birth cohorts to examine and meta-analyze the associations of gestational age, size for gestational age, and infant weight gain with childhood lung function and asthma (age range, 3.9-19.1 years). Second, we explored whether these lung function outcomes mediated the associations of early growth characteristics with childhood asthma. RESULTS Children born with a younger gestational age had a lower FEV1, FEV1/forced vital capacity (FVC) ratio, and forced expiratory volume after exhaling 75% of vital capacity (FEF75), whereas those born with a smaller size for gestational age at birth had a lower FEV1 but higher FEV1/FVC ratio (P < .05). Greater infant weight gain was associated with higher FEV1 but lower FEV1/FVC ratio and FEF75 in childhood (P < .05). All associations were present across the full range and independent of other early-life growth characteristics. Preterm birth, low birth weight, and greater infant weight gain were associated with an increased risk of childhood asthma (pooled odds ratio, 1.34 [95% CI, 1.15-1.57], 1.32 [95% CI, 1.07-1.62], and 1.27 [95% CI, 1.21-1.34], respectively). Mediation analyses suggested that FEV1, FEV1/FVC ratio, and FEF75 might explain 7% (95% CI, 2% to 10%) to 45% (95% CI, 15% to 81%) of the associations between early growth characteristics and asthma. CONCLUSIONS Younger gestational age, smaller size for gestational age, and greater infant weight gain were across the full ranges associated with childhood lung function. These associations explain the risk of childhood asthma to a substantial extent.
Resumo:
METHODS Spirometry datasets from South-Asian children were collated from four centres in India and five within the UK. Records with transcription errors, missing values for height or spirometry, and implausible values were excluded(n = 110). RESULTS Following exclusions, cross-sectional data were available from 8,124 children (56.3% male; 5-17 years). When compared with GLI-predicted values from White Europeans, forced expired volume in 1s (FEV1) and forced vital capacity (FVC) in South-Asian children were on average 15% lower, ranging from 4-19% between centres. By contrast, proportional reductions in FEV1 and FVC within all but two datasets meant that the FEV1/FVC ratio remained independent of ethnicity. The 'GLI-Other' equation fitted data from North India reasonably well while 'GLI-Black' equations provided a better approximation for South-Asian data than the 'GLI-White' equation. However, marked discrepancies in the mean lung function z-scores between centres especially when examined according to socio-economic conditions precluded derivation of a single South-Asian GLI-adjustment. CONCLUSION Until improved and more robust prediction equations can be derived, we recommend the use of 'GLI-Black' equations for interpreting most South-Asian data, although 'GLI-Other' may be more appropriate for North Indian data. Prospective data collection using standardised protocols to explore potential sources of variation due to socio-economic circumstances, secular changes in growth/predictors of lung function and ethnicities within the South-Asian classification are urgently required.
Resumo:
Environmental tobacco smoke (ETS) is a well established health hazard, being causally associated to lung cancer and cardiovascular disease. ETS regulations have been developed worldwide to reduce or eliminate exposure in most public places. Restaurants and bars constitute an exception. Restaurants and bar workers experience the highest ETS exposure levels across several occupations, with correspondingly increased health risks. In Mexico, previous exposure assessment in restaurants and bars showed concentrations in bars and restaurants to be the highest across different public and workplaces. Recently, Mexico developed at the federal level the General Law for Tobacco Control restricting indoors smoking to separated areas. AT the local level Mexico City developed the Law for the Protection of Non-smokers Health, completely banning smoking in restaurants and bars. Studies to assess ETS exposure in restaurants and bars, along with potential health effects were required to evaluate the impact of these legislative changes and to set a baseline measurement for future evaluations.^ A large cross-sectional study conducted in restaurants and bars from four Mexican cities was conducted from July to October 2008, to evaluate the following aims: Aim 1) Explore the potential impact of the Mexico City ban on ETS concentrations through comparison of Mexico City with other cities. Aim 2). Explore the association between ETS exposure, respiratory function indicators and respiratory symptoms. Aim 3). Explore the association between ETS exposure and blood pressure and heart rate.^ Three cities with no smoking ban were selected: Colima (11.5% smoking prevalence), Cuernavaca (21.5% smoking prevalence) and Toluca (27.8% smoking prevalence). Mexico City (27.9% smoking prevalence), the only city with a ban at the time of the study, was also selected. Restaurants and bars were randomly selected from municipal records. A goal of 26 restaurants and 26 bars per city was set, 50% of them under 100 m2. Each establishment was visited during the highest occupancy shift, and managers and workers answered to a questionnaire. Vapor-phase nicotine was measured using passive monitors, that were activated at the beginning and deactivated at the end of the shift. Also, workers participated at the beginning and end of the shift in a short physical evaluation, comprising the measurement of Forced Expiratory Volume in the first second (FEV1) and Peak Expiratory Flow (PEF), as well as blood pressure and heart rate.^ A total of 371 establishments were invited, 219 agreed to participate for a 60.1% participation rate. In them, 828 workers were invited, 633 agreed to participate for a 76% participation rate. Mexico City had at least 4 times less nicotine compared to any of the other cities. Differences between Mexico City and other cities were not explained by establishment characteristics, such as ventilation or air extraction. However, differences between cities disappeared when ban mechanisms, such as policy towards costumer's smoking, were considered in the models. An association between ETS exposure and respiratory symptoms (cough OR=1.27, 95%CI=1.04, 1.55) and respiratory illness (asthma OR=1.97, 95%CI=1.20, 3.24; respiratory illness OR=1.79, 95%CI=1.10, 2.94) was observed. No association between ETS and phlegm, wheezing or respiratory infections was observed. No association between ETS and any of the spirometric indicators was observed. An association between ETS exposure and increased systolic and diastolic blood pressure at the end of the shift was observed among non-smokers (systolic blood pressure beta=1.51, 95%CI=0.44, 2.58; diastolic blood pressure beta=1.50, 95%CI=0.72, 2.28). The opposite effect was observed in heavy smokers, were increased ETS exposure was associated with lower blood pressure at the end of the shift (systolic blood pressure beta=1.90, 95%CI=-3.57, -0.23; diastolic blood pressure beta=-1.46, 95%CI=-2.72, -0.02). No association in light smokers was observed. No association for heart rate was observed. ^ Results from this dissertation suggest Mexico City's smoking ban has had a larger impact on ETS exposure. Ventilation or air extraction, mechanisms of ETS control suggested frequently by tobacco companies to avoid smoking bans were not associated with ETS exposure. This dissertation suggests ETS exposure could be linked to changes in blood pressure and to increased respiratory symptoms. Evidence derived from this dissertation points to the potential negative health effects of ETS exposure in restaurants and bars, and provides support for the development of total smoking bans in this economic sector. ^
Resumo:
Asthma is a chronic complex disorder of the respiratory tract that affects millions of people globally, a large percentage of which are children. Triggered by a host of factors such as allergens and changes in temperature, the pathophysiologic and clinical indices vary among patients and have contributed to difficulties in overall management of asthma. Shortly after exhaled nitric oxide (eNO) was discovered in higher concentrations in asthma patients, it was shown to be superior to other markers such as PEFR, FEV1 and sputum eosinophils in screening asthma patients. Studies have also noted promising results regarding the use of eNO to predict asthma exacerbation in adults while in children, asthma symptoms have been observed to be good predictors of asthma exacerbation. Currently however, the potential of eNO as a predictor of asthma exacerbation in children is yet to be examined. The objective of this study was to assess eNO potential to predict asthma exacerbation in children by examining the relationship between eNO and changes in pulmonary function, asthma symptoms and rescue medication use.^ The primary study "Air Toxics and Asthma in Children" (ATAC), recruited children aged 9 to 14 years with labile persistent asthma diagnosed at least one year earlier. The data obtained from 30 study participants, included exhaled nitric oxide concentration, PEFR, FEV1, asthma symptoms and frequency of emergency medication use.^ Descriptive statistics, Pearson's and Spearman's correlation tests were followed by a simple linear regression in which eNO was the independent (predictor) variable while FEV1, PEFR, asthma symptoms and frequency of emergency medication use were the dependent (outcome) variables.^ Results showed that eNO was associated with percent change in FEV1, day time wheeze, night time shortness of breath, but correlated only weakly with PEFR, amplitude percent of mean PEFR, FEV1, percent change in FEV1 and asthma symptoms.^ Further research is imperative to better define the role of eNO and understand intrinsic pathologic mechanisms towards asthma management in children.^
Resumo:
Outdoor environmental risk factors for asthma have been extensively researched, even though the majority of a person's daily activity occurs indoors. There is limited evidence linking personal exposure concentrations of ozone, pollen, mold, temperature, and humidity to childhood asthma. ^ The current study consisted of a secondary, more complex analysis of the data from the Houston Air Toxics and Asthma in Children (ATAC) Study to further investigate the association of personal ozone exposure on asthma outcome variability among middle school children with asthma. The ATAC Study primarily investigated the association between selected oxygenated air toxics and indicators of asthma variability (PEFR, FEV1, asthma symptoms, and rescue medication usage) among 30 labile and persistent Houston middle-school children with diagnosed asthma. This panel study used a repeated measurements design of four separate 10-day sampling periods that extended over a 20 month period. The secondary analysis included aggregate regression models that were constructed with two different estimates of ozone exposure (daily maximum hourly outdoor concentration and daily maximum hourly personal exposure), with three different estimates of personal environmental temperature and humidity exposures (daily average, intraday difference, and interday difference), and for thee different time periods [same day of exposure (lag 0), one day after initial exposure (lag 1), and two days after initial exposure (lag 2)]. ^ Overall, the models using daily maximum hourly personal ozone exposures in combination with intraday and interday personal temperature and humidity differences produced more significant plausible associations than models using daily maximum hourly personal ozone exposures with personal average temperature and humidity exposures. Significant associations were identified between daily maximum hourly personal ozone exposure and clinical indicators of asthma variability. The increasing effect on rescue medication usage from daily maximum hourly personal ozone exposure were identified as soon as the same day of exposure (lag 0; p=0.0072), and the same effects were delayed until the second next day (lag 2; p= 0.0026). The increasing effect on asthma symptoms were identified on the second next day after initial exposure (lag 2; p= 0.0024). There was a consistent inverse relationship between personal relative humidity exposure and indicators of asthma variability. Decreasing effects on daily FEV1 variability from personal relative humidity exposure were identified on the same day of exposure (lag 0; p= 0.034), increasing effects on morning PEFR were identified on the next day after initial exposure (lag 1; p= 0.0001), and decreasing effects on overnight PEFR variability were identified on the second next day after the initial exposure (lag 2; p= 0.007). With the conclusion of this research, there are opportunities for future similar studies in the preventive management of asthma in children living in high-ozone areas.^
Resumo:
Bakers are repeatedly exposed to wheat flour (WF) and may develop sensitization and occupational rhinoconjunctivitis and/or asthma to WF allergens.1 Several wheat proteins have been identified as causative allergens of occupational respiratory allergy in bakery workers.1 Testing of IgE reactivity in patients with different clinical profiles of wheat allergy (food allergy, wheat-dependent exercise-induced anaphylaxis, and baker's asthma) to salt-soluble and salt-insoluble protein fractions from WF revealed a high degree of heterogeneity in the recognized allergens. However, mainly salt-soluble proteins (albumins, globulins) seem to be associated with baker's asthma, and prolamins (gliadins, glutenins) with wheat-dependent exercise-induced anaphylaxis, whereas both protein fractions reacted to IgE from food-allergic patients.1 Notwithstanding, gliadins have also been incriminated as causative allergens in baker's asthma.2 We report on a 31-year-old woman who had been exposed to WF practically since birth because her family owned a bakery housed in the same home where they lived. She moved from this house when she was 25 years, but she continued working every day in the family bakery. In the last 8 years she had suffered from work-related nasal and ocular symptoms such as itching, watery eyes, sneezing, nasal stuffiness, and rhinorrhea. These symptoms markedly improved when away from work and worsened at work. In the last 5 years, she had also experienced dysphagia with frequent choking, especially when ingesting meats or cephalopods, which had partially improved with omeprazole therapy. Two years before referral to our clinic, she began to have dry cough and breathlessness, which she also attributed to her work environment. Upper and lower respiratory tract symptoms increased when sifting the WF and making the dough. The patient did not experience gastrointestinal symptoms with ingestion of cereal products. Skin prick test results were positive to grass (mean wheal, 6 mm), cypress (5 mm) and Russian thistle pollen (4 mm), WF (4 mm), and peach lipid transfer protein (6 mm) and were negative to rice flour, corn flour, profilin, mites, molds, and animal dander. Skin prick test with a homemade WF extract (10% wt/vol) was strongly positive (15 mm). Serologic tests yielded the following results: eosinophil cationic protein, 47 ?g/L; total serum IgE, 74 kU/L; specific IgE (ImmunoCAP; ThermoFisher, Uppsala, Sweden) to WF, 7.4 kU/L; barley flour, 1.24 kU/L; and corn, gluten, alpha-amylase, peach, and apple, less than 0.35 kU/L. Specific IgE binding to microarrayed purified WF allergens (WDAI-0.19, WDAI-0.53, WTAI-CM1, WTAI-CM2, WTAI-CM3, WTAI-CM16, WTAI-CM17, Tri a 14, profilin, ?-5-gliadin, Tri a Bd 36 and Tri a TLP, and gliadin and glutamine fractions) was assessed as described elsewhere.3 The patient's serum specifically recognized ?-5-gliadin and the gliadin fraction, and no IgE reactivity was observed to other wheat allergens. Spirometry revealed a forced vital capacity of 3.88 L (88%), an FEV1 of 3.04 L (87%), and FEV1/forced vital capacity of 83%. A methacholine inhalation test was performed following an abbreviated protocol,4 and the results were expressed as PD20 in cumulative dose (mg) of methacholine. Methacholine inhalation challenge test result was positive (0.24 mg cumulative dose) when she was working, and after a 3-month period away from work and with no visits to the bakery house, it gave a negative result. A chest x-ray was normal. Specific inhalation challenge test was carried out in the hospital laboratory by tipping WF from one tray to another for 15 minutes. Spirometry was performed at baseline and at 2, 5, 10, 15, 20, 30, 45, and 60 minutes after the challenge with WF. Peak expiratory flow was measured at baseline and then hourly over 24 hours (respecting sleeping time). A 12% fall in FEV1 was observed at 20 minutes and a 26% drop in peak expiratory flow at 9 hours after exposure to WF,
Resumo:
Com o objetivo de se avaliar a importância do \"clearance\" do dietilenotriamino-pentacetato marcado com Tecnécio 99m (DTPA-Tecnécio-99m) em portadores de pneumopatia por amiodarona foram estudados 40 indivíduos, em quatro grupos. Grupo I: 10 voluntários normais, assintomáticos e não fumantes (8 homens e 2 mulheres), com média de idade de 56,80 anos. Grupo II: 10 voluntários normais, assintomáticos e fumantes (6 homens e 4 mulheres ), com média de idade de 27,50 anos. Grupo III: 10 pacientes não fumantes ( 4 homens e 5 mulheres ), com média de idade de 52,90 anos. Todos faziam uso crônico de amiodarona por via oral. Grupo IV: 10 pacientes portadores de pneumopatia por amiodarona, quatro ex-fumantes, dois fumantes e quatro não fumantes ( 8 homens e 2 mulheres) com média de idade de 52,90 anos. Todos faziam uso de amiodarona por via oral e nenhum fumou nas 4 semanas que precederam o estudo. Após espirometria que constou do registro da curva volume-tempo, todos inalaram 4 ml de solução salina contendo 740 MBq de DTPA Tecnécio-99m, durante cinco minutos. Através de uma c~mara de cintilação computadorizada foram obtidas imagens pulmonares, definindo-se 9 áreas de interesse. Para cada região escolhida foi determinada uma curva de \"clearance\" extraindo-se o valor de meia-vida biológica em minu- tos ( T 1/2 ) e a taxa percentual de \" clearance\" alvéolo capilar do radioaerossol por minuto (K%/min). Observamos que, das variáveis espirométricas consideradas, a capacidade vital forçada (CVF) e o volume expiratório forçado no 1 segundo (VEF1) mostraram diferenças significantes entre os grupos I e IV. A contagem total de radioatividade de ambos os pulmões não mostrou relação com a CVF e o VEF1. O \" clearance \" pulmonar do DTPA Tecnécio-99m foi maior nos grupos 11 e IV, porém não permitindo sua diferenciação. Estes resultados permitem concluir: Os pacientes portadores de pneumonite por amiodaro- na apresentam\" clearance \" alvéolo-capilar de DTPA Tecnécio-99m significativamente maior que os indivíduos do grupo de normais não fumantes. Este fato também se verificou em relação aos pacientes em uso crônico de amiodarona mas sem evidências de pneumopatia. Não é possível diferenciar os fumantes dos portadores de pneumonite por amiodarona através da análise da integridade da barreira alvéolo-epitelial com DTPA Tecnécio-99m. Comparativamente, o estudo da integridade alvéolo-epitelial pelo \"clearance\" pulmonar de DTPA Tecnécio-99m é mais sensível que a espirometria na avaliação da pneumonite por amiodarona, permitindo diferenciar estes pacientes dos que fazem uso crônico da droga
Resumo:
Introdução: A DPOC é uma doença respiratória prevenível e tratável, caracterizada por limitação persistente ao fluxo aéreo, hiperinsuflação e aprisionamento aéreo. A dispneia e a intolerância aos esforços, decorrentes destas alterações fisiopatológicas sofre influência de vários fatores. Dentre estes, o recrutamento e a sobrecarga imposta aos músculos inspiratórios e expiratórios são de fundamental importância, porém a participação destes ainda não foi completamente elucidada em diferentes gravidades da doença. Objetivos: O objetivo principal deste estudo foi avaliar a mecânica ventilatória, e o grau de recrutamento da musculatura inspiratória e expiratória na DPOC leve e grave, na condição de repouso e durante um teste máximo de exercício, comparado a um grupo de indivíduos saudáveis. Metodologia: Trata-se de um estudo transversal envolvendo 36 indivíduos, sendo 24 pacientes portadores de DPOC e 12 voluntários sadios. As avaliações foram divididas em 2 visitas. No D1, foram realizadas uma avaliação clínica, avaliação de dispneia (mMRC) e de qualidade de vida (SGRQ), além da prova de função pulmonar completa. Na 2ª visita, realizada com intervalo de 1 semana, foram avaliadas: as pressões respiratórias máximas estáticas por meio de métodos volitivos (PImax, PEmax, SNIP, Pes sniff, Pga sniff e Pdi sniff) e não volitivos (Twitch cervical bilateral e T10); avaliação da sincronia toracoabdominal por pletismografia de indutância; avaliação do recrutamento dos músculos inspiratórios e expiratórios ao repouso pela eletromiografia de superfície; e, posteriormente, um teste de exercício cardiopulmonar incremental para estudo de todas essas variáveis no esforço. Resultados: Foram avaliados 24 pacientes (12 leves e 12 graves) e 12 indivíduos saudáveis da mesma faixa etária. A maioria dos pacientes apresentava comprometimento significativo da qualidade de vida e os pacientes do grupo grave eram mais sintomáticos. A função pulmonar encontrava-se alterada na maioria dos pacientes. Destes, 79,2% apresentavam aprisionamento aéreo e 70,8% tinham redução da DLCO. Tais alterações foram semelhantes nos 2 grupos de pacientes. A força muscular estática medida por métodos volitivos e não volitivos estava reduzida nos 2 grupos e mostrou relação com o VEF1. No exercício, a dispneia foi o principal motivo para interrupção do teste em 70% dos pacientes. A HD esteve presente em 87,5% dos pacientes. O comportamento das pressões respiratórias foi significativamente diferente entre os 3 grupos. Os pacientes com DPOC apresentaram maior atividade diafragmática (Pdi) comparado aos controles e a participação da musculatura expiratória também foi maior neste grupo, principalmente nos graves. Apesar disso, os pacientes com DPOC apresentaram uma eficiência mecânica reduzida, ou seja, esse incremento da força muscular foi insuficiente para manter uma ventilação adequada para uma determinada carga. Com o aumento da demanda ventilatória, houve recrutamento precoce e progressivo dos músculos inspiratórios e expiratórios durante o exercício. O trabalho resistivo e o expiratório foram significativamente diferentes entre os controles e os pacientes com DPOC desde o início do exercício. Como consequência destas alterações, a intensidade da dispneia durante o TECP foi maior nos pacientes com DPOC (leve e grave) para a mesma carga e mesma ventilação-minuto (VE), quando comparada aos indivíduos do grupo-controle. Conclusões: O conjunto destes achados demonstra que o comprometimento dos músculos inspiratórios e expiratórios contribuiu significativamente para a dispneia e a intolerância ao exercício tanto no DPOC leve quanto no DPOC grave. E que este comprometimento pode não ser detectado com os testes máximos de força ao repouso
Resumo:
El contenido del conjunto documental conocido como «Papeles sobre la vacuna» archivado en la Real Academia Nacional de Medicina y generado por Ignacio María Ruiz de Luzuriaga (1763-1822) no ha sido estudiado hasta la fecha de forma exhaustiva. Como parte de una amplia investigación sobre estos manuscritos se describe el hallazgo de un texto inédito producido en 1801 por Ruiz de Luzuriaga que, con forma de ensayo, pretendía recopilar los conocimientos sobre el método vacunal sugerido por Edward Jenner durante los inicios de su introducción en España. Su objetivo era establecer un corpus científico y académico sobre la vacuna que facilitara su comprensión, asimilación y buena práctica entre los vacunadores españoles. El texto, contenido en el volumen 3 de los «Papeles», fue consecutivo a otros dos inmediatamente anteriores, la «Carta a D. Luis» y el «Informe imparcial sobre la vacuna». Este estudio analiza el origen y destinatarios de los tres textos, revelando la identidad de «D. Luis» y describiendo los contenidos del «Ensayo», documento hasta ahora desconocido y en el que destaca por su valor historiográfico la primera traducción al español del «Inquiry» de Jenner, realizada por Ruiz de Luzuriaga.
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
Study objectives: Respiratory muscle weakness and decreased endurance have been demonstrated following mechanical ventilation. However, its relationship to the duration of mechanical ventilation is not known. The aim of this study was to assess respiratory muscle endurance and its relationship to the duration of mechanical ventilation. Design: Prospective study. Setting: Tertiary teaching hospital ICU. Patients: Twenty subjects were recruited for the study who had received mechanical ventilation for a 48 h and had been discharged from the ICU. Measurements: FEV1 FVC, and maximal inspiratory pressure (Pimax) at functional residual capacity were recorded. The Pimax attained following resisted inspiration at 30% of the initial Pimax for 2 min was recorded, and the fatigue resistance index (FRI) [Pimax final/Pimax initial] was calculated. The duration of ICU length of stay (ICULOS), duration of mechanical ventilation (MVD), duration of weaning (WD), and Charlson comorbidities score (CCS) were also recorded. Relationships between fatigue and other parameters were analyzed using the Spearman correlations (p). Results: Subjects were admitted to the ICU for a mean duration of 7.7 days (SD, 3.7 days) and required mechanical ventilation for a mean duration of 4.6 days (SD, 2.5 days). The mean FRI was 0.88 (SD, 0.13), indicating a 12% fall in Pimax, and was negatively correlated with MVD (r = -0.65; p = 0.007). No correlations were found between the FRI and FEV1, FVC, ICULOS, WD, or CCS. Conclusions: Patients who had received mechanical ventilation for > 48 h have reduced inspiratory muscle endurance that worsens with the duration of mechanical ventilation and is present following successful weaning. These data suggest that patients needing prolonged mechanical ventilation are at risk of respiratory muscle fatigue and may benefit from respiratory muscle training.