988 resultados para Esthetics - Dentistry
Resumo:
The relentless pursuit by cosmetic dentistry brought the evolution of materials ceramics. The IPS-Empress system was upgrading of indirect restorations based on lithium disilicate. The ceramic restoration posterior allow a new esthetic approach due to its translucency and resistance without any weakening of the remaining dental element, being an option more conservative when compared to conventional prosthetic restorations.
Resumo:
The reestablishment of a harmonious smile through dental ceramics, when properly conducted and with specific indications, can achieve extremely predictable results. For aesthetic and functional rehabilitation, many ceramic materials can be used such as zirconia, leucite, alumina, feldspar, and lithium disilicate. Among these materials the lithium disilicate stands out due to the following characteristics: its resistance to wear, to chemical attack, high temperatures and oxidation; low electrical conductivity; near zero thermal expansion; good optical properties and biocompatibility with periodontal; excellent esthetics; color stability and reinforcement of tooth structure. The indications for the use of lithium disilicate are not limited to multiple facets of teeth in cases where there was no favorable response to tooth whitening, and also comprehend teeth with multiple restorations, diastema closure, shape alteration, and dental contouring, replacement of missing or fractured teeth, among others. The versatility of lithium disilicate ceramics allows its utilization in several clinical situations. The concomitant use of lithium disilicate for veneers and over metal has satisfactory aesthetic results, as reported in the present studying cases that require both aesthetics and resistance.
Resumo:
The composite resin is the material of election for direct restorations in posterior teeth currently. The restorative dentistry aims to improve each day the material and facilitate the restorative technique. This paper describes the technique of occlusal matrix made to speed up and preservation the occlusal surface of a first molar tooth affected by caries lesion. A new resin-based composite was used called Silorane, which may be placed in larger increments due the material has low shrinkage and polymerization stress. The use of occlusal matrix associated with a low shrinkage resin composite can simplify the clinical work, and result in a restoration with excellent reproduction of anatomical.
Resumo:
The finite element method (FEM) involves a series of computational procedures to calculate the stress in each element, which performs a model solution. Such a structural analysis allows the determination of stress resulting from external force, pressure, thermal change, and other factors. This method is extremely useful for indicating mechanical aspects of biomaterials and human tissues that can hardly be measured in vivo. The results obtained can then be studied using visualization software within the FEM environment to view a variety of parameters, and to fully identify implications of the analysis. Objective: An overview to show application of FEM in dentistry was undertaken. Literature review: This paper shows the basic concept, advances, advantages, limitations and applications of finite element method (FEM) in dentistry. Conclusion: It is extremely important to verify what the purpose of the study is in order to correctly apply FEM.
Resumo:
Introduction: The finite element method (FEM) involves a series of computational procedures to calculate the stress in each element, which performs a model solution. Such a structural analysis allows the determination of stress resulting from external force, pressure, thermal change, and other factors. This method is extremely useful for indicating mechanical aspects of biomaterials and human tissues that can hardly be measured in vivo. The results obtained can then be studied using visualization software within the FEM environment to view a variety of parameters, and to fully identify implications of the analysis. Objective: An overview to show application of FEM in dentistry was undertaken. Literature review: This paper shows the basic concept, advances, advantages, limitations and applications of finite element method (FEM) in dentistry. Conclusion: It is extremely important to verify what the purpose of the study is in order to correctly apply FEM.
Resumo:
The purpose of this study was to estimate the alcoholic beverage consumption among undergraduate students of a Dentistry Course and compare the effectiveness of screening methods for the detection of binge drinking. A total of 284 undergraduate students participated in the research. We used the full AUDIT and their reduced forms (AUDIT-3 and AUDIT-C). In addition, a ROC curve was created and its area was calculated. Of the students, 91.0% and 90.6% of the male and female genders, respectively, reported alcohol beverage consumption. Bing-drinking behavior occurred in 69.2% of the men and in 52.4% of the women. The 3 methods showed good discriminatory ability. For the women, there was a significant difference between the AUDIT-3 and AUDIT-C. Both the complete version of AUDIT and its reduced forms presented good discriminatory ability
Resumo:
The Burnout Syndrome is considered a psychosocial problem to which teachers are routinely exposed. This study was conducted to estimate the prevalence of burnout in Dentistry teachers and its relation to relevant socio-demographic variables. The participants were 70 teachers from the undergraduate Dentistry Course, Faculty of Dentistry of Araraquara – UNESP. Oldenburg Burnout Inventory (OLBI) was used. The prevalence of burnout was estimated. In order to compare performed. Mean age of participants was 46.0 ± 6.1 and teaching experience was 19.6±7.6 years. The prevalence of burnout was 17.1%. Low mean scores for Exhaustion (2.11±0.61) and Disengagement (1.73±0.50) were observed. There reported taking medication due to work (p=0.008) and for those who have thought about quit teaching (p=0.001). There scores according to the habit of taking medication, the experience as a teacher and gender
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In laboratory tests, just following the manufacturer’s instructions of materials or equipments may not be enough to obtain reliable data. Thus, intra and inter-examiners studies may be required. The aim of this study was to illustrate the application of the Intraclass Correlation Coefficient (r) in a study related to the color changing and hardness of composite resin conducted by two examiners. The color and hardness of 10 specimens of composite resin were evaluated by a colorimetric spectrophotometer and hardness tester, respectively, at two different times. Two trained examiners performed two measurements with an interval of one week. Specimens were stored in artificial saliva at 37±1ºC for 7 days. The Intraclass Correlation was used for analysis of intra and inter-examiner reproducibility. The intra-examiner reproducibility was 0.79, 0.44 and 0.76 for L, a and b color coordinates for the examiner 1 and 0.84, 0.23, 0.21 for examiner 2. For hardness, r-values were 0.00 and 0.23 for the examiner 1 and 2, respectively, showing unsatisfactory agreement on color and hardness evaluation for both examiners. It was noted that only the observation of protocol for use of equipment and examiners training were not sufficient to collect reliable information. Thus, adjustments in the experimental protocol were made and devices were produced to standardize the measurements. The reproducibility study was performed again. For examiner 1, values as 0.90, 0.59 and 0.79 were verified for L, a and b coordinates and, for examiner 2 were obtained values of 0.90, 0.75, 0.95. In relation to hardness, r-values of 0.75 and 0.71 were obtained for examiners 1 and 2, respectively. The inter-examiner reproducibility was 0.86, 0.87, 0.91 for L, a and b coordinates and 0.79 for hardness. It was concluded that intra and inter-examiner calibration is essential for obtaining quality measurements in laboratory tests.
Resumo:
Visualisation in the field of dentistry has nor, thus far, reached the same development as other medical fields. Potential applications of visualisation techniques in this area, however, are many, ranging from educational displays to training for delicate procedures. This paper reports on the investigation of techniques for handling three-dimensional models of teeth, aiming at investigation of dental structures. An algorithm was implemented for this purpose, which reconstructs three-dimensional teeth models from two-dimensional contour slices. Results employing various data sets are presented, including the output of VRML models for exploration.
Uncommon crown-root fracture treated with adhesive tooth fragment reattachment: 7 years of follow-up
Resumo:
Crown-root fractures account for 5% of all fractures in permanent teeth and can involve enamel, dentin, and cementum. Depending on whether there is pulpal involvement, these problems may be classified as complicated (which are more common) or noncomplicated. The treatment depends on the level of the fracture line, root length and/or morphology, and esthetic needs. Several treatment strategies are available for esthetic and functional rehabilitation in crown-root fractures. Adhesive tooth fragment reattachment is the most conservative restorative option when the tooth fragment is available and the biological width has no or minimal violation. This article reports a case of an uncomplicated crown-root fracture in the permanent maxillary right central incisor of a young patient who received treatment with adhesive tooth fragment reattachment, preserving the anatomic characteristics of the fractured tooth after periodontal intervention. The fracture line of the fragment had an unusual shape, starting on the palatal side and extending to the buccal side subgingivally. After 7 years, the attached coronal fragment remained in position with good esthetics, as well as clinical and radiographic signs of pulpal vitality, periodontal health, and root integrity, thus indicating success.
Resumo:
This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.
Resumo:
This report describes a protocol for managing the accidental swallowing of dental instruments in implant dentistry, illustrated by a patient who accidentally swallowed a hexagonal wrench. The first step was to refer the patient to the medical emergency hospital service for radiographic and clinical evaluation. The hexagonal wrench was located in the stomach and was immediately removed with an endoscopic procedure. The gastric mucosa was sampled via biopsy and the sample submitted to the urease test, which was positive for Helicobacter pylori. Triple treatment was instituted for gastritis caused by H pylori to avoid exposing the patient to unnecessary risk. Removal of a foreign body by means of an endoscopic procedure constitutes a safe and effective treatment.