945 resultados para Esophageal Stenosis
Resumo:
Background and aim of the study: The natriuretic peptides, brain natriuretic peptide (BNP) and its N-terminal prohormone (NT-proBNP), can be used as diagnostic and prognostic markers for aortic stenosis (AS). However, the association between BNP, NT-proBNP, and long-term clinical outcomes in patients with severe AS remains uncertain. Methods: A total of 64 patients with severe AS was prospectively enrolled into the study, and underwent clinical and echocardiographic assessments at baseline. Blood samples were drawn for plasma BNP and NT-proBNP analyses. The primary outcome was death from any cause, through a six-year follow up period. Cox proportional hazards modeling was used to examine the association between natriuretic peptides and long-term mortality, adjusting for important clinical factors. Results: During a mean period of 1,520 681 days, 51 patients (80%) were submitted to aortic valve replacement, and 13 patients (20%) were medically managed without surgical interventions. Mortality rates were 13.7% in the surgical group and 62% in the medically managed group (p <0.001). Patients with higher plasma BNP (>135 pg/ml) and NT-proBNP (>1,150 pg/ml) levels at baseline had a greater risk of long-term mortality (hazard ratio [HR] 3.2, 95% confidence interval [CI] 1.1-9.1; HR 4.3, 95% CI 1.4-13.5, respectively). After adjusting for important covariates, both BNP and NT-proBNP remained independently associated with long-term mortality (HR 2.9, 95%CI 1.5-5.7; HR 1.8, 95%CI 1.1-3.1, respectively). Conclusion: In patients with severe AS, plasma BNP and NT-proBNP levels were associated with long-term mortality. The use of these biomarkers to guide treatment might represent an interesting approach that deserves further evaluation. The Journal of Heart Valve Disease 2012;21:331-336
Resumo:
Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.
Resumo:
There are no studies investigating the effect of the contrast infusion on the sensitivity and specificity of the main Doppler criteria of renal artery stenosis (RAS). Our aim was to evaluate the accuracy of these Doppler criteria prior to and following the intravenous administration of perfluorocarbon exposed sonicated albumin (PESDA) in patients suspected of having RAS. Thirty consecutive hypertensive patients (13 males, mean age of 57 ± 10 years) suspected of having RAS by clinical clues, were submitted to ultrasonography (US) of renal arteries before and after enhancement using continuous infusion of PESDA. All patients underwent angiography, and haemodynamically significant RAS was considered when ≥50%. At angiography, it was detected RAS ≥50% in 18 patients, 5 with bilateral stenosis. After contrast, the examination time was slightly reduced by approximately 20%. In non-enhanced US the sensitivity was better when based on resistance index (82.9%) while the specificity was better when based on renal aortic ratio (89.2%). The predictive positive value was stable for all indexes (74.0%–88.0%) while negative predictive value was low (44%–51%). The specificity and positive predictive value based on renal aortic ratio increased after PESDA injection respectively, from 89 to 97.3% and from 88 to 95%. In hypertensives suspected to have RAS the sensitivity and specificity of Duplex US is dependent of the criterion evaluated. Enhancement with continuous infusion of PESDA improves only the specificity based on renal aortic ratio but do not modify the sensitivity of any index.
Resumo:
CONTEXT: Esophageal dysphagia is the sensation that the ingested material has a slow transit or blockage in its normal passage to the stomach. It is not always associated with motility or transit alterations. OBJECTIVES: To evaluate in normal volunteers the possibility of perception of bolus transit through the esophagus after swallows of liquid and solid boluses, the differences in esophageal contraction and transit with these boluses, and the association of transit perception with alteration of esophageal contraction and/or transit. METHODS: The investigation included 11 asymptomatic volunteers, 4 men and 7 women aged 19-58 years. The subjects were evaluated in the sitting position. They performed swallows of the same volume of liquid (isotonic drink) and solid (macaroni) boluses in a random order and in duplicate. After each swallow they were asked about the sensation of bolus passage through the esophagus. Contractions and transit were evaluated simultaneously by solid state manometry and impedance. RESULTS: Perception of bolus transit occurred only with the solid bolus. The amplitude and area under the curve of contractions were higher with swallows of the solid bolus than with swallows of the liquid bolus. The difference was more evident in swallows with no perception of transit (n = 12) than in swallows with perception (n = 10). The total bolus transit time was longer for the solid bolus than for the liquid bolus only with swallows followed by no perception of transit. CONCLUSION: The results suggest that the perception of esophageal transit may be the consequence of inadequate adaptation of esophageal transit and contraction to the characteristics of the swallowed bolus.
Resumo:
INTRODUCTION Echocardiography is the standard clinical approach for quantification of the severity of aortic stenosis (AS). A comprehensive examination of its overall reproducibility and the simultaneous estimation of its variance components by multiple operators, readers, probe applications, and beats have not been undertaken. METHOD AND RESULTS Twenty-seven subjects with AS were scanned over 7 months in the echo-department by a median of 3 different operators. From each patient and each operator multiple runs of beats from multiple probe positions were stored for later analysis by multiple readers. The coefficient of variation was 13.3%, 15.9%, 17.6%, and 20.2% for the aortic peak velocity (Vmax), and velocity time integral (VTI), and left ventricular outflow tract (LVOT) Vmax and VTI respectively. The largest individual contributors to the overall variability were the beat-to-beat variability (9.0%, 9.3%, 9.5%, 9.4% respectively) and that of inability of an individual operator to precisely apply the probe to the same position twice (8.3%, 9.4%, 12.9%, 10.7% respectively). The tracing (inter-reader) and reader (inter-reader), and operator (inter-operator) contribution were less important. CONCLUSIONS Reproducibility of measurements in AS is poorer than often reported in the literature. The source of this variability does not appear, as traditionally believed, to result from a lack of training or operator and reader specific factors. Rather the unavoidable beat-to-beat biological variability, and the inherent impossibility of applying the ultrasound probe in exactly the same position each time are the largest contributors. Consequently, guidelines suggesting greater standardisation of procedures and further training for sonographers are unlikely to result in an improvement in precision. Clinicians themselves should be wary of relying on even three-beat averages as their expected coefficient of variance is 10.3% for the peak velocity at the aortic valve.
Resumo:
Background. A sizable group of patients with symptomatic aortic stenosis (AS) can undergo neither surgical aortic valve replacement (AVR) nor transcatheter aortic valve implantation (TAVI) because of clinical contraindications. The aim of this study was to assess the potential role of balloon aortic valvuloplasty (BAV) as a “bridge-to-decision” in selected patients with severe AS and potentially reversible contraindications to definitive treatment. Methods. We retrospectively enrolled 645 patients who underwent first BAV at our Institution between July 2007 and December 2012. Of these, the 202 patients (31.2%) who underwent BAV as bridge-to-decision (BTD) requiring clinical re-evaluation represented our study population. BTD patients were further subdivided in 5 groups: low left ventricular ejection fraction; mitral regurgitation grade ≥3; frailty; hemodynamic instability; comorbidity. The main objective of the study was to evaluate how BAV influenced the final treatment strategy in the whole BTD group and in its single specific subgroups. Results. Mean logistic EuroSCORE was 23.5±15.3%, mean age was 81±7 years. Mean transaortic gradient decreased from 47±17 mmHg to 33±14 mmHg. Of the 193 patients with BTD-BAV who received a second heart team evaluation, 72.5% were finally deemed eligible for definitive treatment (25.4%for AVR; 47.2% for TAVI): respectively, 96.7% of patients with left ventricular ejection fraction recovery; 70.5% of patients with mitral regurgitation reduction; 75.7% of patients who underwent BAV in clinical hemodynamic instability; 69.2% of frail patients and 68% of patients who presented relevant comorbidities. 27.5% of the study population was deemed ineligible for definitive treatment and treated with standard therapy/repeated BAV. In-hospital mortality was 4.5%, cerebrovascular accident occurred in 1% and overall vascular complications were 4% (0.5% major; 3.5% minor). Conclusions. Balloon aortic valvuloplasty should be considered as bridge-to-decision in high-risk patients with severe aortic stenosis who cannot be immediate candidates for definitive percutaneous or surgical treatment.
Resumo:
Esophageal dilation often leads to long-lasting relief of dysphagia in eosinophilic esophagitis (EoE). The aim of this study was to define the effectiveness, safety, and patient acceptance of esophageal dilation in EoE. In addition, we examined the influence of dilation on the underlying esophageal inflammation.
Resumo:
The optimal management of patients with symptomatic severe ostial vertebral artery stenosis (OVAS) is currently unclear. We analyzed the long-term outcome of consecutive patients with OVAS who received either medical treatment (MT) or vertebral artery stenting (VAS).
Resumo:
Retrospective case-referent study.
Resumo:
There is no standard treatment for patients with locally advanced esophageal carcinoma without systemic metastasis in whom surgery is no longer considered a reasonable option.
Resumo:
This multicenter phase IB/II trial investigated cetuximab added to preoperative chemoradiotherapy for esophageal cancer.
Resumo:
This study sought to assess post-procedural and mid-term outcome of patients, in which a second "in-series" CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) was implanted during the same procedure.
Resumo:
The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified.
Resumo:
EUS response assessment in patients with locally advanced esophageal cancer undergoing neoadjuvant chemoradiation therapy (CRT) is limited by disintegration of the involved anatomic structures.