954 resultados para Electric relays


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transmission of bulk power at high voltages over very long distances has become very imperative. At present, throughout the globe, this task has been mostly performed by overhead transmission lines. The dual task of mechanically supporting and electrically isolating the live phase conductors from the support tower is performed by string insulators. Whether in clean condition or under polluted conditions, the electrical stress distribution along the insulators governs the possible flashover, which is quite detrimental to the system. However, a reliable data on stress distribution in commonly employed string insulators are rather scarce. Considering this, the present work has made an attempt to study accurately, the field distribution in 220 kV strings for six different types of porcelain/ceramic insulators (Normal and Antifog discs) used for high voltage transmission. The surface charge simulation method is employed for the required field computation. Voltage and electric stress distribution is deduced and compared across different types of discs. A comparison on normalised surface resistance, which is an indicator for the stress concentration under polluted condition, is also attempted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fixed and mobile relays are used, among other applications, in the downlink of cellular communications systems. Cooperation between relays can greatly increase their benefits in terms of extended coverage, increased reliability, and improved spectral efficiency. In this paper, we introduce the fundamental notion of asymmetric cooperation. For this, we consider a two-phase transmission protocol where, in the first phase, the base station (BS) sends several available messages to the relays over wireless links. But, depending on the channel state and the duration of the BS transmission, not all relays decode all messages. In a second phase, the relays, which may now have asymmetric message knowledge, use cooperative linear precoding for the transmission to the mobile stations. We show that for many channel configurations, asymmetric cooperation, although (slighlty) sub-optimum for the second phase, is optimum from a total-throughput point of view, as it requires less time and energy in the first phase. We give analytical formulations for the optimum operating parameters and the achievable throughput, and show that under typical circumstances, 20-30% throughput enhancement can be achieved over conventional systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this talk I discuss some aspects of the study of electric dipole moments (EDMs) of the fermions, in the context of R-parity violating (\rpv) Supersymmetry (SUSY). I will start with a brief general discussion of how dipole moments, in general, serve as a probe of physics beyond the Standard Model (SM) and an even briefer summary of \rpv SUSY. I will follow by discussing a general method of analysis for obtaining the leading fermion mass dependence of the dipole moments and present its application to \rpv SUSY case. Then I will summarise the constraints that the analysis of $e,n$ and $Hg$ EDMs provide for the case of trilinear \rpv SUSY couplings and make a few comments on the case of bilinear \rpv, where the general method of analysis proposed by us does not work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nuclear electro-magnetic pulse (NEMP) simulators which are used in the simulation of transient electromagnetic fields due to a high altitude nuclear detonation are generally excited with a double exponential high voltage pulse. This results in a current distribution on the wires of the simulator and hence a transient electric field in the working volume of the simulator where the test object is kept. It is found that for the simulator under study, the current distribution is non-uniform and so is the field distribution along the width of the simulator in the working volume. To make the current distribution uniform, several methods have been suggested and the results of these methods are analyzed and suitable conclusions are arrived at from those results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Titanium dioxide (TiO(2)) films have been deposited on glass and p-silicon (1 0 0) substrates by DC magnetron sputtering technique to investigate their structural, electrical and optical properties. The surface composition of the TiO(2) films has been analyzed by X-ray photoelectron spectroscopy. The TiO(2) films formed on unbiased substrates were amorphous. Application of negative bias voltage to the substrate transformed the amorphous TiO(2) into polycrystalline as confirmed by Raman spectroscopic studies. Thin film capacitors with configuration of Al/TiO(2)/p-Si have been fabricated. The leakage current density of unbiased films was 1 x10(-6) A/cm(2) at a gate bias voltage of 1.5 V and it was decreased to 1.41 x 10(-7) A/cm(2) with the increase of substrate bias voltage to -150 V owing to the increase in thickness of interfacial layer of SiO(2). Dielectric properties and AC electrical conductivity of the films were studied at various frequencies for unbiased and biased at -150 V. The capacitance at 1 MHz for unbiased films was 2.42 x 10(-10) F and it increased to 5.8 x 10(-10) F in the films formed at substrate bias voltage of -150 V. Dielectric constant of TiO(2) films were calculated from capacitance-voltage measurements at 1 MHz frequency. The dielectric constant of unbiased films was 6.2 while those formed at -150 V it increased to 19. The optical band gap of the films decreased from 3.50 to 3.42 eV with the increase of substrate bias voltage from 0 to -150 V. (C) 2011 Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper reports the development of new amplitude-comparator techniques which allow the instantaneous comparison of the amplitude of the signals derived from primary line quantities. These techniques are used to derive a variety of impedance characteristics. The merits of the new relaying system are: the simple mode of the relay circuitry, the derivation of closed polar characteristics (i.e. quadrilateral) by a single measuring gate and sharp discontinuities in the polar characteristics. Design principles and circuit models in their schematic form are described and, in addition, a comprehensive theoretical basis for comparison is also presented. Dynamic test results are presented for a quadrilateral characteristic of potentially general application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new technique is presented using principles of multisignal relaying for the synthesis of a universal-type quadrilateral polar characteristic. The modus operandi consists in the determination of the phase sequence of a set of voltage phasors and the provision of a trip signal for one sequence while blocking for the other. Two versions, one using ferrite-core logic and another using transistor logic, are described in detail. The former version has the merit of simplicity and has the added advantage of not requiring any d.c. supply. The unit is flexible, as it permits independent control of the characteristic along the resistance and reactance axis through suitable adjustments of replica impedance angles. The maximum operating time is about 20ms for all switching angles, and with faults within 95% of the protected section. The maximum transient overreach is about 8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new hybrid comparison technique for transmission line protection, providing polar characteristics marked by sharp discontinuities, has been developed. The comparator models, described in block schematic form, accompany a steady state theoretical basis for comparison. Dynamic test results are indicated for a directional quadrilateral characteristic which closely corresponds to the probable fault area of a transmission line.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prebreakdown currents in a coaxial cylindrical geometry in nitrogen have been measured with and without a crossed magnetic field. The range of parameters used in the investigation are 2.6 ÿ p ÿ 14.5 torr, 50 ÿ (E/p) ÿ 420 V cm-1 torr-1, and 43.0 ÿ H/p ÿ 1185 Oe torr-1 (p is the pressure, E is the electric field, and H is the magnetic field). The initial photoelectric current is obtained by allowing photons produced in an auxiliary glow discharge to strike the cathode. Ions and electrons produced in the auxiliary discharge are prevented from reaching the main gap by suitable shielding. By modifying the Rice equation for back diffusion, the measured ionization current multiplication without a crossed magnetic field is compared with the multiplication predicted by the Townsend growth equation for nonuniform electric fields. It is observed that over the range of 50 Ã�¿ (E/P)max Ã�¿ 250 [(E/P)max is the value of E/p at the central electrode of the coaxial system] measured and calculated multiplication of current agree with each other. With a crossed magnetic field the prebreakdown currents have been measured and compared with the theoretically calculated currents using the equivalent pressure concept. Agreement between the calculated and measured currents is not satisfactory, and this has been attributed more to the uncertainty in the collision frequency data available than nonuniformity of the electric field. Sparking potentials have been measured with and without a crossed magnetic field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most of the modern distance relays are designed to avoid overreaching due to the transient d.c. component of the fault current, whereas a more likely source of transients in e.h.v. systems is the oscillatory discharge of the system charging current into the fault. Until now attempts have not been made to reproduce these transients in the laboratory. This paper describes an analogue and an accurate digital simulation of these harmonic transients. The dynamic behaviour of a typical polarised mho-type relay is analysed, and results are presented. The paper also advocates the use of active filters for filtering the harmonics associated with e.h.v. system, and hence, to improve the speed of response and accuracy of the protective relays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper reports further work on the amplitude-comparison technique described by the same authors in a previous paper. This technique is extended to develop improved polar characteristics. Discontinuous polar characteristics, like directional parallelograms, are obtained by a single measuring gate with a simple mode of relay circuitry, whereas two measuring gates are required to provide a directional-quadrilateral characteristic of potentially general application. The paper also describes some new possibilities in phase-comparison methods for distance-protection schemes. Comparator models which effect the amplitude and phase comparison of the relaying signals are described in their schematic form. A comprehensive theoretical basis for comparison is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Static distance relays employing semiconductor devices as their active elements offer many advantages over the conventional electromagnetic and rectifier relays. The paper describes single-system and three-system static distance relays, which depend for their operation on the instantaneous-comparison or `block-spike¿ scheme. Design principles and typical discriminating and logic circuits are described for the new relaying equipment. The relaying circuitry has been devised for obtaining uniform performance on all kinds of faults, by the use of two phase detectors¿one for multiphase faults and one for earth faults. The phase detector for multiphase faults provides an improved polar characteristic in the complex-impedance plane, which fits only around the fault area of a transmission line. The other features of the relay are: reliable pickup for close-in faults, least susceptibility to maloperation under power-swing conditions, and reduction in cost and panel space required. The operating characteristics of the relays, as expressed by accuracy/range charts, are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simpler circuits for frequency-sensitive relays responding to change and rate of change of system frequency have been developed employing phase-locked loops. A new relay responding to time intergral of the fall in system frequency has also been developed and its performance has been compared with those responding to change and rate of change of system frequency. The relays have been tested and calibrated with the help of a specially designed calibration kit.