Resumo:
Recently, a novel method to trap and pattern ensembles of nanoparticles has been proposed and tested. It relies on the photovoltaic (PV) properties of certain ferroelectric crystals such as LiNbO3 [1,2]. These crystals, when suitably doped, develop very high electric fields in response to illumination with light of suitable wavelength. The PV effect lies in the asymmetrical excitation of electrons giving rise to PV currents and associated space-charge fields (photorefractive effect). The field generated in the bulk of the sample propagates to the surrounding medium as evanescent fields. When dielectric or metal nanoparticles are deposited on the surface of the sample the evanescent fields give rise to either electrophoretic or dielectrophoretic forces, depending on the charge state of the particles, that induce the trapping and patterning effects [3,4]. The purpose of this work has been to explore the effects of such PV fields in the biology and biomedical areas. A first work was able to show the necrotic effects induced by such fields on He-La tumour cells grown on the surface of an illuminated iron-doped LiNbO3 crystal [5]. In principle, it is conceived that LiNbO3 nanoparticles may be advantageously used for such biomedical purposes considering the possibility of such nanoparticles being incorporated into the cells. Previous experiments using microparticles have been performed [5] with similar results to those achieved with the substrate. Therefore, the purpose of this work has been to fabricate and characterize the LiNbO3 nanoparticles and assess their necrotic effects when they are incorporated on a culture of tumour cells. Two different preparation methods have been used: 1) mechanical grinding from crystals, and 2) bottom-up sol-gel chemical synthesis from metal-ethoxide precursors. This later method leads to a more uniform size distribution of smaller particles (down to around 50 nm). Fig. 1(a) and 1(b) shows SEM images of the nanoparticles obtained with both method. An ad hoc software taking into account the physical properties of the crystal, particullarly donor and aceptor concentrations has been developped in order to estimate the electric field generated in noparticles. In a first stage simulations of the electric current of nanoparticles, in a conductive media, due to the PV effect have been carried out by MonteCarlo simulations using the Kutharev 1-centre transport model equations [6] . Special attention has been paid to the dependence on particle size and [Fe2+]/[Fe3+]. First results on cubic particles shows large dispersion for small sizes due to the random number of donors and its effective concentration (Fig 2). The necrotic (toxicity) effect of nanoparticles incorporated into a tumour cell culture subjected to 30 min. illumination with a blue LED is shown in Fig.3. For each type of nanoparticle the percent of cell survival in dark and illumination conditions has been plot as a function of the particle dilution factor. Fig. 1a corresponds to mechanical grinding particles whereas 1b and 1c refer to chemically synthesized particles with two oxidation states. The light effect is larger with mechanical grinding nanoparticles, but dark toxicity is also higher. For chemically synthesized nanoparticles dark toxicity is low but only in oxidized samples, where the PV effect is known to be larger, the light effect is appreciable. These preliminary results demonstrate that Fe:LiNbO· nanoparticles have a biological damaging effect on cells, although there are many points that should be clarified and much space for PV nanoparticles optimization. In particular, it appears necessary to determine the fraction of nanoparticles that become incorporated into the cells and the possible existence of threshold size effects. This work has been supported by MINECO under grant MAT2011-28379-C03.
Resumo:
El viento, como factor medio-ambiental, ha sido objeto de numerosos estudios por los efectos que induce tanto en vehículos como en estructuras. Dentro del ámbito ferroviario, las cargas aerodinámicas debidas a la acción del viento transversal pueden poner en compromiso la seguridad de los vehículos en circulación, pudiendo llegar a ocasionar el vuelco del mismo. Incluso el sistema de cables encargado de realizar el suministro eléctrico necesario para la tracción del tren, conocido como catenaria, es sensible a la acción del viento. De hecho, al igual que ocurre en ciertas estructuras de cables, la interacción entre las fuerzas aerodinámicas no estacionarias y la catenaria puede ocasionar la aparición de oscilaciones de gran amplitud debido al fenómeno de galope. Una forma sencilla de reducir los efectos no deseados de la acción del viento, es la instalación de barreras cortavientos aguas arriba de la zona que se desea proteger. La instalación de estos dispositivos, reduce la velocidad en la estela generada, pero también modifica las propiedades del flujo dentro de la misma. Esta alteración de las condiciones del flujo puede contribuir a la aparición del fenómeno de galope en estructuras caracterizadas por su gran flexibilidad, como la catenaria ferroviaria. Estos dos efectos contrapuestos hacen evidente la importancia de mantener cierta visión global del efecto introducido por la instalación de barreras cortavientos en la plataforma ferroviaria. A lo largo de este documento, se evalúa desde un enfoque multidisciplinar el efecto inducido por las barreras cortavientos en varios subsistemas ferroviarios. Por un lado se analizan las mejoras en la estabilidad lateral del vehículo mediante una serie de ensayos en túnel de viento. La medición de la distribución de presiones en la superficie de un modelo bidimensional de vehículo ferroviario proporciona una buena estimación del nivel de protección que se consigue en función de la altura de una barrera cortavientos. Por otra parte, se analiza la influencia del mismo juego de barreras cortavientos en las características del flujo situado sobre la plataforma ferroviaria, mediante la utilización de anemometría de hilo caliente (HWA) y velocimetría de imágenes de párticulas (PIV). En particular se centra la atención en las características en la posición correspondiente a los hilos conductores de la catenaria. En la última parte del documento, se realiza un análisis simplificado de la aparición oscilaciones en la catenaria, por el efecto de la inestabilidad de galope. La información obtenida sobre las características del flujo se combinan con las propiedades aerodinámicas del hilo de contacto, obtenidas en mediante una serie de ensayos en túnel de viento. De esta manera se realiza una evaluación del riesgo a la aparición de este tipo de inestabilidad aeroeslástica aplicada a una catenaria ferroviaria situada sobre un viaducto tipo. ABSTRACT Wind as an environmental factor may induce undesirable effects on vehicles and structures. The analysis of those effects has caught the attention of several researchers. Concerning the railway system, cross-wind induces aerodynamic loads on rolling stock that may increase the overturning risk of the vehicle, threatening its safe operation. Even the cable system responsible to provide the electric current required for the train traction, known as the railway overhead or catenary, is sensitive to the wind action. In fact, the interaction between the unsteady aerodynamic forces and the railway overhead may trigger the development of undamped oscillations due to galloping phenomena. The inclusion of windbreaks upstream the area that needs wind protection is a simple mean to palliate the undesirable effects caused by the wind action. Although the presence of this wind protection devices reduces the wind speed downstream, they also modify the flow properties inside their wake. This modification on the flow characteristics may ease the apparition of the galloping phenomena on flexible structures, such as the railway overhead. This two opposite effects require to maintain a global perspective on the analysis of the influence of the windbreak presence. In the present document, a multidisciplinary analysis on the effect induced by windbreaks on several railways subsystems is conducted. On the one hand, a set of wind tunnel tests is conducted to assess the improvement on the rolling stock lateral stability. The qualitative estimation of the shelter effect, as function of the windbreak height, is established through the pressure distribution measured on the surface of a two-dimensional train model. On the other hand, the flow properties above the railway platform are assessed using the same set of windbreaks. Two experimental techniques are used to measure the flow properties, hot-wire anemometry (HWA) and particle image velocimetry (PIV). In particular, the attention is focused on the flow characteristics on the contact wire location. A simplified analysis on the catenary oscillations due to galloping phenomena is conducted in the last part of the document. Both, the flow characterization performed via PIV and the aerodynamic properties of the contact wire cross-section are combined. In this manner, the risk of the aeroelastic instabilities on a railway overhead placed on a railway bridge is assessed through a practical application.
Resumo:
La presente tesis es un estudio analítico y numérico del electrospray. En la configuración más sencilla, un caudal constante del líquido a atomizar, que debe tener una cierta conductividad eléctrica, se inyecta en un medio dieléctrico (un gas u otro líquido inmiscible con el primero) a través de un tubo capilar metálico. Entre este tubo y un electrodo lejano se aplica un voltaje continuo que origina un campo eléctrico en el líquido conductor y en el espacio que lo rodea. El campo eléctrico induce una corriente eléctrica en el líquido, que acumula carga en su superficie, y da lugar a un esfuerzo eléctrico sobre la superficie, que tiende a alargarla en la dirección del campo eléctrico. El líquido forma un menisco en el extremo del tubo capilar cuando el campo eléctrico es suficientemente intenso y el caudal suficientemente pequeño. Las variaciones de presión y los esfuerzos viscosos asociados al movimiento del líquido son despreciables en la mayor parte de este menisco, siendo dominantes los esfuerzos eléctrico y de tensión superficial que actúan sobre la superficie del líquido. En el modo de funcionamiento llamado de conochorro, el balance de estos esfuerzos hace que el menisco adopte una forma cónica (el cono de Taylor) en una región intermedia entre el extremo del tubo y la punta del menisco. La velocidad del líquido aumenta al acercarse al vértice del cono, lo cual propicia que las variaciones de la presión en el líquido generadas por la inercia o por la viscosidad entren en juego, desequilibrando el balance de esfuerzos mencionado antes. Como consecuencia, del vértice del cono sale un delgado chorro de líquido, que transporta la carga eléctrica que se acumula en la superficie. La acción del campo eléctrico tangente a la superficie sobre esta carga origina una tracción eléctrica que tiende a alargar el chorro. Esta tracción no es relevante en el menisco, donde el campo eléctrico tangente a la superficie es muy pequeño, pero se hace importante en el chorro, donde es la causa del movimiento del líquido. Lejos del cono, el chorro puede o bien desarrollar una inestabilidad asimétrica que lo transforma en una espiral (whipping) o bien romperse en un spray de gotas prácticamente monodispersas cargadas eléctricamente. La corriente eléctrica transportada por el líquido es la suma de la corriente de conducción en el interior del líquido y la corriente debida a la convección de la carga acumulada en su superficie. La primera domina en el menisco y la segunda en el chorro lejano, mientras que las dos son comparables en una región intermedia de transferencia de corriente situada al comienzo del chorro aunque aguas abajo de la región de transición cono-chorro, en la que el menisco deja de ser un cono de Taylor. Para un campo exterior dado, la acumulación de carga eléctrica en la superficie del líquido reduce el campo eléctrico en el interior del mismo, que llega a anularse cuando la carga alcanza un estado final de equilibrio. El tiempo característico de este proceso es el tiempo de relajación dieléctrica, que es una propiedad del líquido. Cuando el tiempo de residencia del líquido en la región de transición cono-chorro (o en otra región del campo fluido) es grande frente al tiempo de relajación dieléctrica, la carga superficial sigue una sucesión de estados de equilibrio y apantalla al líquido del campo exterior. Cuando esta condición deja de cumplirse, aparecen efectos de relajación de carga, que se traducen en que el campo exterior penetra en el líquido, a no ser que su constante dieléctrica sea muy alta, en cuyo caso el campo inducido por la carga de polarización evita la entrada del campo exterior en el menisco y en una cierta región del chorro. La carga eléctrica en equilibrio en la superficie de un menisco cónico intensifica el campo eléctrico y determina su variación espacial hasta distancias aguas abajo del menisco del orden de su tamaño. Este campo, calculado por Taylor, es independiente del voltaje aplicado, por lo que las condiciones locales del flujo y el valor de la corriente eléctrica son también independientes del voltaje en tanto los tamaños de las regiones que determinan estas propiedades sean pequeños frente al tamaño del menisco. Los resultados experimentales publicados en la literatura muestran que existe un caudal mínimo para el que el modo cono-chorro que acabamos de describir deja de existir. El valor medio y la desviación típica de la distribución de tamaños de las gotas generadas por un electrospray son mínimos cuando se opera cerca del caudal mínimo. A pesar de que los mecanismos responsables del caudal mínimo han sido muy estudiados, no hay aún una teoría completa del mismo, si bien su existencia parece estar ligada a la aparición de efectos de relajación de carga en la región de transición cono-chorro. En esta tesis, se presentan estimaciones de orden de magnitud, algunas existentes y otras nuevas, que muestran los balances dominantes responsables de las distintas regiones de la estructura asintótica de la solución en varios casos de interés. Cuando la inercia del líquido juega un papel en la transición cono-chorro, los resultados muestran que la región de transferencia de corriente, donde la mayor parte de la corriente pasa a la superficie, está en el chorro aguas abajo de la región de transición cono-chorro. Los efectos de relajación de carga aparecen de forma simultánea en el chorro y la región de transición cuando el caudal se disminuye hasta valores de un cierto orden. Para caudales aún menores, los efectos de relajación de carga se notan en el menisco, en una región grande comparada con la de transición cono-chorro. Cuando el efecto de las fuerzas de viscosidad es dominante en la región de transición, la región de transferencia de corriente está en el chorro pero muy próxima a la región de transición cono-chorro. Al ir disminuyendo el caudal, los efectos de relajación de carga aparecen progresivamente en el chorro, en la región de transición y por último en el menisco. Cuando el caudal es mucho mayor que el mínimo del modo cono-chorro, el menisco deja de ser cónico. El campo eléctrico debido al voltaje aplicado domina en la región de transferencia de corriente, y tanto la corriente eléctrica como el tamaño de las diferentes regiones del problema pasan a depender del voltaje aplicado. Como resultado de esta dependencia, el plano caudal-voltaje se divide en diferentes regiones que se analizan separadamente. Para caudales suficientemente grandes, la inercia del líquido termina dominando frente a las fuerzas de la viscosidad. Estos resultados teóricos se han validado con simulaciones numéricas. Para ello se ha formulado un modelo simplificado del flujo, el campo eléctrico y el transporte de carga en el menisco y el chorro del electrospray. El movimiento del líquido se supone casi unidireccional y se describe usando la aproximación de Cosserat para un chorro esbelto. Esta aproximación, ampliamente usada en la literatura, permite simular con relativa facilidad múltiples casos y cubrir amplios rangos de valores de los parámetros reteniendo los efectos de la viscosidad y la inercia del líquido. Los campos eléctricos dentro y fuera del liquido están acoplados y se calculan sin simplificación alguna usando un método de elementos de contorno. La solución estacionaria del problema se calcula mediante un método iterativo. Para explorar el espacio de los parámetros, se comienza calculando una solución para valores fijos de las propiedades del líquido, el voltaje aplicado y el caudal. A continuación, se usa un método de continuación que permite delinear la frontera del dominio de existencia del modo cono-chorro, donde el método iterativo deja de converger. Cuando el efecto de la inercia del líquido domina en la región de transición cono-chorro, el caudal mínimo para el cual el método iterativo deja de converger es del orden del valor estimado del caudal para el que comienza a haber efectos de relajación de carga en el chorro y el cono. Aunque las simulaciones no convergen por debajo de dicho caudal, el valor de la corriente eléctrica para valores del caudal ligeramente mayores parece ajustarse a las estimaciones para caudales menores, reflejando un posible cambio en los balances aplicables. Por el contrario, cuando las fuerzas viscosas dominan en la región de transición, se pueden obtener soluciones estacionarias para caudales bastante menores que aquel para el que aparecen efectos de relajación de carga en la región de transición cono-chorro. Los resultados numéricos obtenidos para estos pequeños caudales se ajustan perfectamente a las estimaciones de orden de magnitud que se describen en la memoria. Por último, se incluyen como anexos dos estudios teóricos que han surgido de forma natural durante el desarrollo de la tesis. El primero hace referencia a la singularidad en el campo eléctrico que aparece en la línea de contacto entre el líquido y el tubo capilar en la mayoría de las simulaciones. Primero se estudia en qué situaciones el campo eléctrico tiende a infinito en la línea de contacto. Después, se comprueba que dicha singularidad no supone un fallo en la descripción del problema y que además no afecta a la solución lejos de la línea de contacto. También se analiza si los esfuerzos eléctricos infinitamente grandes a los que da lugar dicha singularidad pueden ser compensados por el resto de esfuerzos que actúan en la superficie del líquido. El segundo estudio busca determinar el tamaño de la región de apantallamiento en un chorro de líquido dieléctrico sin carga superficial. En esta región, el campo exterior es compensado parcialmente por el campo que induce la carga de polarización en la superficie del líquido, de forma que en el interior del líquido el campo eléctrico es mucho menor que en el exterior. Una región como ésta aparece en las estimaciones cuando los efectos de relajación de carga son importantes en la región de transferencia de corriente en el chorro. ABSTRACT This aim of this dissertation is a theoretical and numerical analysis of an electrospray. In its most simple configuration, a constant flow rate of the liquid to be atomized, which has to be an electrical conductor, is injected into a dielectric medium (a gas or another inmiscible fluid) through a metallic capillary tube. A constant voltage is applied between this tube and a distant electrode that produces an electric field in the liquid and the surrounding medium. This electric field induces an electric current in the liquid that accumulates charge at its surface and leads to electric stresses that stretch the surface in the direction of the electric field. A meniscus appears on the end of the capillary tube when the electric field is sufficiently high and the flow rate is small. Pressure variations and viscous stresses due to the motion of the liquid are negligible in most of the meniscus, where normal electric and surface tension stresses acting on the surface are dominant. In the so-called cone-jet mode, the balance of these stresses forces the surface to adopt a conical shape -Taylor cone- in a intermediate region between the end of the tube and the tip of the meniscus. When approaching the cone apex, the velocity of the liquid increases and leads to pressure variations that eventually disturb the balance of surfaces tension and electric stresses. A thin jet emerges then from the tip of the meniscus that transports the charge accumulated at its surface. The electric field tangent to the surface of the jet acts on this charge and continuously stretches the jet. This electric force is negligible in the meniscus, where the component of the electric field tangent to the surface is small, but becomes very important in the jet. Far from the cone, the jet can either develop an asymmetrical instability named “whipping”, whereby the jet winds into a spiral, or break into a spray of small, nearly monodisperse, charged droplets. The electric current transported by the liquid has two components, the conduction current in the bulk of the liquid and the convection current due to the transport of the surface charge by the flow. The first component dominates in the meniscus, the second one in the far jet, and both are comparable in a current transfer region located in the jet downstream of the cone-jet transition region where the meniscus ceases to be a Taylor cone. Given an external electric field, the charge that accumulates at the surface of the liquid reduces the electric field inside the liquid, until an equilibrium is reached in which the electric field induced by the surface charge counters the external electric field and shields the liquid from this field. The characteristic time of this process is the electric relaxation time, which is a property of the liquid. When the residence time of the liquid in the cone-jet transition region (or in other region of the flow) is greater than the electric relaxation time, the surface charge follows a succession of equilibrium states and continuously shield the liquid from the external field. When this condition is not satisfied, charge relaxation effects appear and the external field penetrates into the liquid unless the liquid permittivity is large. For very polar liquids, the field due to the polarization charge at the surface prevents the external field from entering the liquid in the cone and in certain region of the jet. The charge at the surface of a conical meniscus intensifies the electric field around the cone, determining its spatial variation up to distances downstream of the apex of the order of the size of the meniscus. This electric field, first computed by Taylor, is independent of the applied voltage. Therefore local flow characteristics and the electric current carried by the jet are also independent of the applied voltage provided the size of the regions that determine these magnitudes are small compared with the size of the meniscus. Many experiments in the literature show the existence of a minimum flow rate below which the cone-jet mode cannot be established. The mean value and the standard deviation of the electrospray droplet size distribution are minimum when the device is operated near the minimum flow rate. There is no complete explanation of the minimum flow rate, even though possible mechanisms have been extensively studied. The existence of a minimum flow rate seems to be connected with the appearance of charge relaxation effects in the transition region. In this dissertation, order of magnitude estimations are worked out that show the dominant balances in the different regions of the asymptotic structure of the solution for different conditions of interest. When the inertia of the liquid plays a role in the cone-jet transition region, the region where most of the electric current is transfered to the surface lies in the jet downstream the cone-jet transition region. When the flow rate decreases to a certain value, charge relaxation effects appear simultaneously in the jet and in the transition region. For smaller values of the flow rate, charge relaxation effects are important in a region of the meniscus larger than the transition region. When viscous forces dominate in the flow in the cone-jet transition region, the current transfer region is located in the jet immediately after the transition region. When flow rate is decreased, charge relaxation effects appears gradually, first in the jet, then in the transition region, and finally in the meniscus. When flow rate is much larger than the cone-jet mode minimum, the meniscus ceases to be a cone. The electric current and the structure of the solution begin to depend on the applied voltage. The flow rate-voltage plane splits into different regions that are analyzed separately. For sufficiently large flow rates, the effect of the inertia of the liquid always becomes greater than the effect of the viscous forces. A set of numerical simulations have been carried out in order to validate the theoretical results. A simplified model of the problem has been devised to compute the flow, the electric field and the surface charge in the meniscus and the jet of an electrospray. The motion of the liquid is assumed to be quasi-unidirectional and described by Cosserat’s approximation for a slender jet. This widely used approximation allows to easily compute multiple configurations and to explore wide ranges of values of the governing parameters, retaining the effects of the viscosity and the inertia of the liquid. Electric fields inside and outside the liquid are coupled and are computed without any simplification using a boundary elements method. The stationary solution of the problem is obtained by means of an iterative method. To explore the parameter space, a solution is first computed for a set of values of the liquid properties, the flow rate and the applied voltage, an then a continuation method is used to find the boundaries of the cone-jet mode domain of existence, where the iterative method ceases to converge. When the inertia of the liquid dominates in the cone-jet transition region, the iterative method ceases to converge for values of the flow rate for which order-of-magnitude estimates first predict charge relaxation effects to be important in the cone and the jet. The electric current computed for values of the flow rate slightly above the minimum for which convergence is obtained seems to agree with estimates worked out for lower flow rates. When viscous forces dominate in the transition region, stationary solutions can be obtained for flow rates significantly smaller than the one for which charge relaxation effects first appear in the transition region. Numerical results obtained for those small values of the flow rate agree with our order of magnitude estimates. Theoretical analyses of two issues that have arisen naturally during the thesis are summarized in two appendices. The first appendix contains a study of the singularity of the electric field that most of the simulations show at the contact line between the liquid and the capillary tube. The electric field near the contact line is analyzed to determine the ranges of geometrical configurations and liquid permittivity where a singularity appears. Further estimates show that this singularity does not entail a failure in the description of the problem and does not affect the solution far from the contact line. The infinite electric stresses that appear at the contact line can be effectively balanced by surface tension. The second appendix contains an analysis of the size and slenderness of the shielded region of a dielectric liquid in the absence of free surface charge. In this region, the external electric field is partially offset by the polarization charge so that the inner electric field is much lower than the outer one. A similar region appears in the estimates when charge relaxation effects are important in the current transfer region.
Resumo:
Earthquake zones in the upper crust are usually more conductive than the surrounding rocks, and electrical geophysical measurements can be used to map these zones. Magnetotelluric (MT) measurements across fault zones that are parallel to the coast and not too far away can also give some important information about the lower crustal zone. This is because the long-period electric currents coming from the ocean gradually leak into the mantle, but the lower crust is usually very resistive and very little leakage takes place. If a lower crustal zone is less resistive it will be a leakage zone, and this can be seen because the MT phase will change as the ocean currents leave the upper crust. The San Andreas Fault is parallel to the ocean boundary and close enough to have a lot of extra ocean currents crossing the zone. The Loma Prieta zone, after the earthquake, showed a lot of ocean electric current leakage, suggesting that the lower crust under the fault zone was much more conductive than normal. It is hard to believe that water, which is responsible for the conductivity, had time to get into the lower crustal zone, so it was probably always there, but not well connected. If this is true, then the poorly connected water would be at a pressure close to the rock pressure, and it may play a role in modifying the fluid pressure in the upper crust fault zone. We also have telluric measurements across the San Andreas Fault near Palmdale from 1979 to 1990, and beginning in 1985 we saw changes in the telluric signals on the fault zone and east of the fault zone compared with the signals west of the fault zone. These measurements were probably seeing a better connection of the lower crust fluids taking place, and this may result in a fluid flow from the lower crust to the upper crust. This could be a factor in changing the strength of the upper crust fault zone.
Resumo:
Cardiac arrhythmias are a frequent cause of death and morbidity. Conventional antiarrhythmia therapy involving oral or intravenous medication is often ineffective and complicated by drug-associated side effects. Previous studies from our laboratory have demonstrated the advantages of cardiac drug-polymer implants for enhanced efficacy for cardiac arrhythmia therapy compared with conventional administration. However, these studies were based on systems that deliver drugs at a fixed release rate. Modulation of the drug delivery rate has the advantage of regulating the amount of the drug delivered depending upon the disease state of the patient. We hypothesized that iontophoresis could be used to modulate cardiac drug delivery. In this study, we report our investigations of a cardiac drug implant in dogs that is capable of iontophoretic modulation of the administration of the antiarrhythmic agent sotalol. We used a heterogeneous cation-exchange membrane (HCM) as an electrically sensitive and highly efficient rate-limiting barrier on the cardiac-contacting surface of the implant. Thus, electric current is passed only through the HCM and not the myocardium. The iontophoretic cardiac implant demonstrated in vitro drug release rates that were responsive to current modulation. In vivo results in dogs have confirmed that iontophoresis resulted in regional coronary enhancement of sotalol levels with current-responsive increases in drug concentrations. We also observed acute current-dependent changes in ventricular effective refractory periods reflecting sotalol-induced refractoriness due to regional drug administration. In 30-day dog experiments, iontophoretic cardiac implants demonstrated robust sustained function and reproducible modulation of drug delivery kinetics.
Resumo:
A aquisição experimental de sinais neuronais é um dos principais avanços da neurociência. Por meio de observações da corrente e do potencial elétricos em uma região cerebral, é possível entender os processos fisiológicos envolvidos na geração do potencial de ação, e produzir modelos matemáticos capazes de simular o comportamento de uma célula neuronal. Uma prática comum nesse tipo de experimento é obter leituras a partir de um arranjo de eletrodos posicionado em um meio compartilhado por diversos neurônios, o que resulta em uma mistura de sinais neuronais em uma mesma série temporal. Este trabalho propõe um modelo linear de tempo discreto para o sinal produzido durante o disparo do neurônio. Os coeficientes desse modelo são calculados utilizando-se amostras reais dos sinais neuronais obtidas in vivo. O processo de modelagem concebido emprega técnicas de identificação de sistemas e processamento de sinais, e é dissociado de considerações sobre o funcionamento biofísico da célula, fornecendo uma alternativa de baixa complexidade para a modelagem do disparo neuronal. Além disso, a representação por meio de sistemas lineares permite idealizar um sistema inverso, cuja função é recuperar o sinal original de cada neurônio ativo em uma mistura extracelular. Nesse contexto, são discutidas algumas soluções baseadas em filtros adaptativos para a simulação do sistema inverso, introduzindo uma nova abordagem para o problema de separação de spikes neuronais.
Resumo:
A beta-alumina de sódio é uma cerâmica condutora de íons Na+ utilizada como eletrólito sólido em baterias de sódio para armazenamento de energias intermitentes como energia solar e eólica. Devido ao alto teor de sódio, esse material é instável a altas temperaturas, podendo sofrer variações de composição durante a etapa de sinterização convencional que utiliza altas temperaturas por longos períodos de tempo. A sinterização flash é uma técnica de sinterização ativada por corrente elétrica que proporciona a densificação de compactos cerâmicos em poucos segundos, a temperaturas notavelmente mais baixas que as convencionais. Uma vez obrigatória a passagem de corrente elétrica através da amostra, a sinterização flash de qualquer material condutor parece bastante razoável. Não obstante, até o presente momento a maioria dos trabalhos publicados sobre o assunto aborda apenas condutores de vacância de oxigênio ou semicondutores, materiais compatíveis com eletrodos de platina (Pt). Nesse trabalho a sinterização flash de um condutor catiônico foi estudada utilizando-se a beta-alumina como material modelo. A beta-alumina foi sintetizada pelo método dos precursores poliméricos, caracterizada e então submetida à sinterização flash. O material de eletrodo padrão (platina) provou ser um eletrodo bloqueador em contato com a beta-alumina. O sucesso da sinterização flash foi determinado pela troca do material de eletrodo por prata (Ag), o que possibilitou uma reação eletroquímica reversível nas interfaces eletrodo-cerâmica e possibilitou a obtenção de um material densificado com morfologia e composição química homogêneas. Devido à metaestabilidade da beta-alumina, a atmosfera dos experimentos precisou ser alterada para manter a integridade desse material rico em um metal alcalino (Na+). A sinterização flash de um condutor catiônico é apresentada pela primeira vez na literatura e ressalta a importância da reação de eletrodo, que é um fator limitante para o sucesso da sinterização flash e precisa ser estudada e adaptada para cada tipo de material.
Resumo:
This research studies the self-heating produced by the application of an electric current to conductive cement pastes with carbonaceous materials. The main parameters studied were: type and percentage of carbonaceous materials, effect of moisture, electrical resistance, power consumption, maximum temperature reached and its evolution and ice melting kinetics are the main parameters studied. A mathematical model is also proposed, which predicts that the degree of heating is adjustable with the applied voltage. Finally, the results have been applied to ensure that cementitious materials studied are feasible to control ice layers in transportation infrastructures.
Resumo:
v.1. Water consumption, costs and savings.--v.2. Electric current consumption costs and savings.
Resumo:
"August 1956."
Resumo:
"October 1963."
Resumo:
"20 May 1985."
Resumo:
"5 March 1985."
Resumo:
This work intent to study the motive power provided by the plane linear induction motor, in a lock condition. It uses a method of imposition of the electric current to the stator via a frequency convertor PWM driven by a refed platform. The reading of the motive power was performed by a load cell using an electronic circuit for reading and conditioning of the signal. Aiming a complete analysis of the linear motor, it was performed a computational modeling that employs all relevant parameters to the study of the locked machine. At the end it was held a theoric-experimental confrontation that evaluated the effectiveness of the proposed method.
Resumo:
The industrial production of aluminium is an electrolysis process where two superposed horizontal liquid layers are subjected to a mainly vertical electric current supplied by carbon electrodes. The lower layer consists of molten aluminium and lies on the cathode. The upper layer is the electrolyte and is covered by the anode. The interface between the two layers is often perturbed, leading to oscillations, or waves, similar to the waves on the surface of seas or lakes. The presence of electric currents and the resulting magnetic field are responsible for electromagnetic (Lorentz) forces within the fluid, which can amplify these oscillations and have an adverse influence on the process. The electrolytic bath vertical to horizontal aspect ratio is such, that it is advantageous to use the shallow water equations to model the interface motion. These are the depth-averaging the Navier-Stokes equations so that nonlinear and dispersion terms may be taken into account. Although these terms are essential to the prediction of wave dynamics, they are neglected in most of the literature on interface instabilities in aluminium reduction cells where only the linear theory is usually considered. The unknown variables are the two horizontal components of the fluid velocity, the height of the interface and the electric potential. In this application, a finite volume resolution of the double-layer shallow water equations including the electromagnetic sources has been developed, for incorporation into a generic three-dimensional computational fluid dynamics code that also deals with heat transfer within the cell.