914 resultados para Effluent oily
Resumo:
This paper reviews nitrogen (N) cycle of effluent-irrigated energy crop plantations, starting from wastewater treatment to thermo-chemical conversion processes. In wastewater, N compounds contribute to eutrophication and toxicity in water cycle. Removal of N via vegetative filters and specifically in short-rotation energy plantations, is a relatively new approach to managing nitrogenous effluents. Though combustion of energy crops is in principle carbon neutral, in practice, N content may contribute to NOx emissions with significant global warming potential. Intermediate pyrolysis produces advanced fuels while reducing such emissions. By operating at intermediate temperature (500°C), it retains most N in char as pyrrolic-N, pyridinic-N, quaternary-N and amines. In addition, biochar provides long-term sequestration of carbon in soils.
Resumo:
The treatment of effluents produced during the manufacture of metallurgical coke is normally carried out using the activated sludge process. The efficiency of activated sludges in purifying coke oven effluent depends largely on the maintenance of species of micro-organisms which destroy thiocyanate. The composition, production, toxicity and treatment of coke oven effluent at Corby steelworks are described. A review is presented which follows the progress made towards identifying and monitoring the species of bacteria which destroy thiocyanate in biological treatment plants purifying coke oven effluents. In the present study a search for bacteria capable of destroying thiocyanate led to the isolation of a species of bacteria, identified as Pseudomonas putida, which destroyed thiocyanate in the presence of succinate; this species had not previously been reported to use thiocyanate. Washed cell suspensions of P. putida destroyed phenol and thiocyanate simultaneously and thiocyanate destruction was not suppressed by pyridine, aniline or catechol at the highest concentrations normally encountered in coke oven effluent. The isolate has been included, as N.C.I.B. 11198, in the National Collection of Industrial Bacteria, Torrey Research Station, Aberdeen. Three other isolates, identified as Achromobacter sp., Thiobacillus thioparus and T. denitrificans, were also confirmed to destroy thi.ocyanate. A technique has been developed for monitoring populations of different species of bacteria in activated sludges. Application of this technique to laboratory scale and full scale treatment plants at Corby showed that thiobacilli were usually not detected; thiobacilli were el~inated during the commissioning period of the full scale plant. However experiments using a laboratory scale plant indicated that during a period of three weeks an increase in the numbers of thiobacilli might have contributed to an improvement in plant performance. Factors which might have facilitated the development of thiobacilli are discussed. Large numbers of fluorescent pseudomonads capable of using thiocyanate were sometimes detected in the laboratory scale plant. The possibility is considered that catechol or other organic compounds in the feed-liquor might have stimulated fluorescent pseudmonads. Experiments using the laboratory scale plant confirmed that deteriorations in the efficiency of thiocyanate destruction were sometimes caused by bulking sludges, due to the excessive growth of fungal floes. Increased dilution of the coke oven effluent was a successful remedy to this difficulty. The optimum operating conditions recommended by the manufacturer of the full scale activated sludge plant at Corby are assessed and the role of bacterial monitoring in a programme of regular monitoring tests is discussed in relation to the operation of activated sludge plants treating coke oven effluents.
Resumo:
In recent years, freshwater fish farmers have come under increasing pressure from the Water Authorities to control the quality of their farm effluents. This project aimed to investigate methods of treating aquacultural effluent in an efficient and cost-effective manner, and to incorporate the knowledge gained into an Expert System which could then be used in an advice service to farmers. From the results of this research it was established that sedimentation and the use of low pollution diets are the only cost effective methods of controlling the quality of fish farm effluents. Settlement has been extensively investigated and it was found that the removal of suspended solids in a settlement pond is only likely to be effective if the inlet solids concentration is in excess of 8 mg/litre. The probability of good settlement can be enhanced by keeping the ratio of length/retention time (a form of mean fluid velocity) below 4.0 metres/minute. The removal of BOD requires inlet solids concentrations in excess of 20 mg/litre to be effective, and this is seldom attained on commercial fish farms. Settlement, generally, does not remove appreciable quantities of ammonia from effluents, but algae can absorb ammonia by nutrient uptake under certain conditions. The use of low pollution, high performance diets gives pollutant yields which are low when compared with published figures obtained by many previous workers. Two Expert Systems were constructed, both of which diagnose possible causes of poor effluent quality on fish farms and suggest solutions. The first system uses knowledge gained from a literature review and the second employs the knowledge obtained from this project's experimental work. Consent details for over 100 fish farms were obtained from the public registers kept by the Water Authorities. Large variations in policy from one Authority to the next were found. These data have been compiled in a computer file for ease of comparison.
Resumo:
This study estimates above-ground biomass in high density plantations of six important semi-arid tree species at Palwal (70 km from Delhi) irrigated with secondary treated sewage water at the rate of 0, 25, 50 and 100% of daily net evaporation potential (EP). In 2.5 y old plantations (plant spacing, 2 m x 2 m for single stem species and 2 m x 1 m for multi-stem species), Melia azedarach showed fairly high biomass production (38.4 t/ha) followed by Ailanthus excelsa (27.2 t/ha). Order of biomass production (kg / tree) was: Eucalyptus tereticornis (24.1) > A. excelsa (21.8) > M. azedarach (12.6) > Populus deltoides clone G 48 (8.3) > Alstonia scholaris (6.6)> Pongamia pinnata (3.7). Survival of plants after 2.5 y ranged from 25.2% in P. deltoides to 71.7% in P. pinnata, and had a significant effect on biomass production per unit area. ANOVA shows that levels of irrigation (0 - 100%) did not have statistically significant effect on plant growth. Correlation between diameter and biomass was found highly significant (p< 0.01) with R2 nearing to 1.
Resumo:
Biofuels derived from industry waste have potential to substitute fossil fuels (Diesel and Gasoline) in internal combustion (IC) engines. Use of waste streams as fuels would help to reduce considerably life-cycle greenhouse gas emissions and minimise waste processing costs. In this study an investigation into the fuel properties of two waste derived biofuels were carried out, they are: (i) Glidfuel (GF) biofuel - a waste stream from paper industry, and (ii) Palm Oil Mill Effluent (POME) biodiesel - biodiesel produced from palm oil industry effluent through various treatment and transesterification process. GF and POME was mixed together at various proportions and separately with fossil diesel (FD) to assess the miscibility and various physical and chemical properties of the blends. Fuel properties such as kinematic viscosity, higher heating value, water content, acid number, density, flash point temperature, CHNO content, sulphur content, ash content, oxidation stability, cetane number and copper corrosion ratings of all the fuels were measured. The properties of GF, POME and various blends were compared with the corresponding properties of the standard FD. Significance of the fuel properties and their expected effects on combustion and exhaust emission characteristics of the IC engine were discussed. Results showed that most properties of both GF and POME biodiesel were comparable to FD. Both GF and POME were miscible with each other, and also separately with the FD. Flash point temperatures of GF and POME biodiesel were 40.7°C and 158.7°C respectively. The flash point temperature of GF was about 36% lower than corresponding FD. The water content in GF and FD were 0.74 (% wt) and 0.01 (% wt) respectively. Acidity values and corrosion ratings of both GF and POME biodiesel were low compared to corresponding value for FD. The study concluded that optimum GF-POME biofuel blends can substitute fossil diesel use in IC engines.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
The amounts of farm dairy effluent stored in ponds and irrigated to land have steadily increased with the steady growth of New Zealand's dairy industry. About 80% of dairy farms now operate with effluent storage ponds allowing deferred irrigation. These storage and irrigation practices cause emissions of greenhouse gases (GHG) and ammonia. The current knowledge of the processes causing these emissions and the amounts emitted is reviewed here. Methane emissions from ponds are the largest contributor to the total GHG emissions from effluent in managed manure systems in New Zealand. Nitrous oxide emissions from anaerobic ponds are negligible, while ammonia emissions vary widely between different studies, probably because they depend strongly on pH and manure composition. The second-largest contribution to GHG emissions from farm dairy effluent comes from nitrous oxide emissions from land application. Ammonia emissions from land application of effluent in New Zealand were found to be less than those reported elsewhere from the application of slurries. Recent studies have suggested that New Zealand's current GHG inventory method to estimate methane emissions from effluent ponds should be revised. The increasing importance of emissions from ponds, while being a challenge for the inventory, also provides an opportunity to achieve mitigation of emissions due to the confined location of where these emissions occur. © 2015 © 2015 The Royal Society of New Zealand.
Resumo:
A Refinaria de Matosinhos é um dos complexos industriais da Galp Energia. A sua estação de tratamento de águas residuais industriais (ETARI) – designada internamente por Unidade 7000 – é composta por quatro tratamentos: o pré-tratamento, o tratamento físico-químico, o tratamento biológico e o pós-tratamento. Dada a interligação existente, é fundamental a otimização de cada um dos tratamentos. Este trabalho teve como objetivos a identificação dos problemas e/ou possibilidades de melhoria do pré-tratamento, tratamento físico-químico e pós-tratamento e principalmente a otimização do tratamento biológico da ETARI. No pré-tratamento verificou-se que a separação de óleos e lamas não era eficaz uma vez que se formam emulsões destas duas fases. Como solução, sugeriu-se a adição de agentes desemulsionantes, que se revelou economicamente inviável. Assim, sugeriu-se como alternativa o recurso a técnicas de tratamento da emulsão gerada, tais como a extração com solvente, centrifugação, ultrassons e micro-ondas. No tratamento físico-químico constatou-se que o controlo da unidade de saturação de ar na água era feito com base na análise visual dos operadores, o que pode conduzir a condições de operação afastadas das ótimas para este tratamento. Assim, sugeriu-se a realização de um estudo de otimização desta unidade com vista à determinação da razão ar/sólidos ótima para este efluente. Para além disto, constatou-se, ainda, que os consumos de coagulante aumentaram cerca de -- % no último ano, pelo que foi sugerido o estudo da viabilidade do processo de eletrocoagulação como substituto do sistema de coagulação existente. No pós-tratamento identificou-se o processo de lavagem dos filtros como sendo a etapa com possibilidade de ser otimizada. Através de um estudo preliminar concluiu-se que a lavagem contínua de um filtro por cada turno melhorava o desempenho dos mesmos. Constatou-se, ainda, que a introdução de ar comprimido na água de lavagem promove uma maior remoção de detritos do leito de areia, no entanto esta prática parece influenciar negativamente o desempenho dos filtros. No caso do tratamento biológico, identificaram-se problemas ao nível do tempo de retenção hidráulico do tratamento biológico II, que apresentou elevada variabilidade. Apesar de identificado concluiu-se que este problema era de difícil solução. Verificou-se, também, que o oxigénio dissolvido não era monitorizado, pelo que se sugeriu a instalação de uma sonda de oxigénio dissolvido numa zona de baixa turbulência do tanque de arejamento. Concluiu-se que o oxigénio era distribuído de forma homogénea por todo o tanque de arejamento e tentou-se identificar quais os fatores que influenciariam este parâmetro, no entanto, dada a elevada variabilidade do efluente e das condições de tratamento, tal não foi possível. Constatou-se, também, que o doseamento de fosfato para o tratamento biológico II era pouco eficiente já Otimização dos sistemas biológicos e melhorias nos tratamentos da ETARI da Refinaria de Matosinhos que em -- % dos dias se verificaram níveis baixos de fosfato no licor misto (< - mg/L). Foi, por isso, proposta a alteração do atual sistema de doseamento por gravidade para um sistema de bomba doseadora. Para além disso verificou-se que os consumos deste nutriente aumentaram significativamente no último ano (cerca de --%), situação que se constatou estar relacionada com um aumento da população microbiana para este período. Foi possível relacionar-se o aparecimento frequente de lamas à superfície dos decantadores secundários com incrementos repentinos de condutividade, pelo que se sugeriu o armazenamento do efluente nas bacias de tempestade, nestas situações. Verificou-se que a remoção de azoto era praticamente ineficaz uma vez que a conversão de azoto amoniacal em nitratos foi muito baixa. Assim, sugeriu-se o recurso à técnica de bio-augmentação ou a transformação do sistema de lamas ativadas num sistema bietápico. Por fim, constatou-se que a temperatura do efluente à entrada da ETARI apresenta valores bastante elevados para o tratamento biológico (aproximadamente de --º C) pelo que se sugeriu a instalação de uma sonda de temperatura no tanque de arejamento de modo a controlar de forma mais eficaz a temperatura do licor misto. Ainda no que diz respeito ao tratamento biológico, foi possível desenvolver-se um conjunto de ferramentas que visaram o funcionamento otimizado deste tratamento. Nesse sentido, foram apresentadas várias sugestões de melhoria: a utilização do índice volumétrico de lamas como indicador da qualidade das lamas em alternativa à percentagem de lamas; foi desenvolvido um conjunto de fluxogramas para a orientação dos operadores de exterior na resolução de problemas; foi criada uma “janela de operação” que pretende ser um guia de apoio à operação; foi ainda proposta a monitorização frequente da idade das lamas e da razão alimento/microrganismo.