889 resultados para Economical and feasibility study
Resumo:
Solar reactors can be attractive in photodegradation processes due to lower electrical energy demand. The performance of a solar reactor for two flow configurations, i.e., plug flow and mixed flow, is compared based on experimental results with a pilot-scale solar reactor. Aqueous solutions of phenol were used as a model for industrial wastewater containing organic contaminants. Batch experiments were carried out under clear sky, resulting in removal rates in the range of 96100?%. The dissolved organic carbon removal rate was simulated by an empirical model based on neural networks, which was adjusted to the experimental data, resulting in a correlation coefficient of 0.9856. This approach enabled to estimate effects of process variables which could not be evaluated from the experiments. Simulations with different reactor configurations indicated relevant aspects for the design of solar reactors.
Resumo:
Hypernuclear physics is currently attracting renewed interest, due tornthe important role of hypernuclei spectroscopy rn(hyperon-hyperon and hyperon-nucleon interactions) rnas a unique toolrnto describe the baryon-baryon interactions in a unified way and to rnunderstand the origin of their short-range.rnrnHypernuclear research will be one of the main topics addressed by the {sc PANDA} experimentrnat the planned Facility for Antiproton and Ion Research {sc FAIR}.rnThanks to the use of stored $overline{p}$ beams, copiousrnproduction of double $Lambda$ hypernuclei is expected at thern{sc PANDA} experiment, which will enable high precision $gamma$rnspectroscopy of such nuclei for the first time.rnAt {sc PANDA} excited states of $Xi^-$ hypernuclei will be usedrnas a basis for the formation of double $Lambda$ hypernuclei.rnFor their detection, a devoted hypernuclear detector setup is planned. This setup consists ofrna primary nuclear target for the production of $Xi^{-}+overline{Xi}$ pairs, a secondary active targetrnfor the hypernuclei formation and the identification of associated decay products and a germanium array detector to perform $gamma$ spectroscopy.rnrnIn the present work, the feasibility of performing high precision $gamma$rnspectroscopy of double $Lambda$ hypernuclei at the {sc PANDA} experiment has been studiedrnby means of a Monte Carlo simulation. For this issue, the designing and simulation of the devoted detector setup as well as of the mechanism to produce double $Lambda$ hypernuclei have been optimizedrntogether with the performance of the whole system. rnIn addition, the production yields of double hypernuclei in excitedrnparticle stable states have been evaluated within a statistical decay model.rnrnA strategy for the unique assignment of various newly observed $gamma$-transitions rnto specific double hypernuclei has been successfully implemented by combining the predicted energy spectra rnof each target with the measurement of two pion momenta from the subsequent weak decays of a double hypernucleus.rn% Indeed, based on these Monte Carlo simulation, the analysis of the statistical decay of $^{13}_{Lambda{}Lambda}$B has been performed. rn% As result, three $gamma$-transitions associated to the double hypernuclei $^{11}_{Lambda{}Lambda}$Bern% and to the single hyperfragments $^{4}_{Lambda}$H and $^{9}_{Lambda}$Be, have been well identified.rnrnFor the background handling a method based on time measurement has also been implemented.rnHowever, the percentage of tagged events related to the production of $Xi^{-}+overline{Xi}$ pairs, variesrnbetween 20% and 30% of the total number of produced events of this type. As a consequence, further considerations have to be made to increase the tagging efficiency by a factor of 2.rnrnThe contribution of the background reactions to the radiation damage on the germanium detectorsrnhas also been studied within the simulation. Additionally, a test to check the degradation of the energyrnresolution of the germanium detectors in the presence of a magnetic field has also been performed.rnNo significant degradation of the energy resolution or in the electronics was observed. A correlationrnbetween rise time and the pulse shape has been used to correct the measured energy. rnrnBased on the present results, one can say that the performance of $gamma$ spectroscopy of double $Lambda$ hypernuclei at the {sc PANDA} experiment seems feasible.rnA further improvement of the statistics is needed for the background rejection studies. Moreover, a more realistic layout of the hypernuclear detectors has been suggested using the results of these studies to accomplish a better balance between the physical and the technical requirements.rn
Resumo:
The thesis work concerns X-ray spectrometry for both medical and space applications and is divided into two sections. The first section addresses an X-ray spectrometric system designed to study radiological beams and is devoted to the optimization of diagnostic procedures in medicine. A parametric semi-empirical model capable of efficiently reconstructing diagnostic X-ray spectra in 'middle power' computers was developed and tested. In addition, different silicon diode detectors were tested as real-time detectors in order to provide a real-time evaluation of the spectrum during diagnostic procedures. This project contributes to the field by presenting an improved simulation of a realistic X-ray beam emerging from a common X-ray tube with a complete and detailed spectrum that lends itself to further studies of added filtration, thus providing an optimized beam for different diagnostic applications in medicine. The second section describes the preliminary tests that have been carried out on the first version of an Application Specific Integrated Circuit (ASIC), integrated with large area position-sensitive Silicon Drift Detector (SDD) to be used on board future space missions. This technology has been developed for the ESA project: LOFT (Large Observatory for X-ray Timing), a new medium-class space mission that the European Space Agency has been assessing since February of 2011. The LOFT project was proposed as part of the Cosmic Vision Program (2015-2025).
Resumo:
Successful extremity transplantations and replantations have to be performed within 6 h of amputation to avoid irreversible tissue loss. This study investigates ex vivo the technical feasibility and the limb preservation potential of extracorporeal whole blood perfusion in a porcine model.
Resumo:
T2 mapping techniques use the relaxation constant as an indirect marker of cartilage structure, and the relaxation constant has also been shown to be a sensitive parameter for cartilage evaluation. As a possible additional robust biomarker, T2* relaxation time is a potential, clinically feasible parameter for the biochemical evaluation of articular cartilage.
Resumo:
This study assessed the safety and efficacy of a novel implantable device therapy in resistant hypertension patients.
Resumo:
(1)H HR-MAS NMR spectroscopy was applied to apple tissue samples deriving from 3 different cultivars. The NMR data were statistically evaluated by analysis of variance (ANOVA), principal component analysis (PCA), and partial least-squares-discriminant analysis (PLS-DA). The intra-apple variability of the compounds was found to be significantly lower than the inter-apple variability within one cultivar. A clear separation of the three different apple cultivars could be obtained by multivariate analysis. Direct comparison of the NMR spectra obtained from apple tissue (with HR-MAS) and juice (with liquid-state HR NMR) showed distinct differences in some metabolites, which are probably due to changes induced by juice preparation. This preliminary study demonstrates the feasibility of (1)H HR-MAS NMR in combination with multivariate analysis as a tool for future chemometric studies applied to intact fruit tissues, e.g. for investigating compositional changes due to physiological disorders, specific growth or storage conditions.
Resumo:
To define the feasibility of utilizing T2* mapping for assessment of early cartilage degeneration prior to surgery in patients with symptomatic femoroacetabular impingement (FAI), we compared cartilage of the hip joint in patients with FAI and healthy volunteers using T2* mapping at 3.0 Tesla over time.
Resumo:
RESEARCH QUESTIONS: To investigate how the daily physical activities of elderly patients can be enhanced by systematic counselling conducted by general practitioners (GPs). METHODS: In this feasibility study with pre-post design, 29 people (14 females, mean age 72.2 years, SD = 6.1) were enrolled during routine visits by two general practitioners. A baseline assessment of current physical activity based on the stages according to the Transtheoretical Model was followed by a counselling session. The target behaviour was defined by performance of 30 minutes of daily moderate-intensity activities that increase the breathing rate, on five days per week. At the 2-month follow-up, subjects were assessed for improvement in stage of physical activity since baseline. After the end of the intervention, participating GPs and patients were asked questions focusing on the feasibility, acceptance and usefulness of counselling. RESULTS: Interview results showed that the two GPs considered the counselling protocol easy to handle and useful for promoting physical activity. Counselling sessions were especially encouraging for the not sufficiently active people. Most of them would like to have additional counselling session. At baseline, 9 of 29 people were sufficiently active. After 2 months, this proportion was 21 of 29. The mean of the number of minutes of physical activity during the previous 4 weeks increased from 247 to 436 minutes (weekly). CONCLUSIONS: The programme was judged positively by the general practitioners and the participating elderly patients. Systematic counselling by general practitioners led to an increase in the physical activity behaviour. Therefore, a more rigorous randomised controlled trial with adequate followup is recommended.
Percutaneous autologous venous valve transplantation: short-term feasibility study in an ovine model
Resumo:
BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.
Resumo:
INTRODUCTION: Recent advances in medical imaging have brought post-mortem minimally invasive computed tomography (CT) guided percutaneous biopsy to public attention. AIMS: The goal of the following study was to facilitate and automate post-mortem biopsy, to suppress radiation exposure to the investigator, as may occur when tissue sampling under computer tomographic guidance, and to minimize the number of needle insertion attempts for each target for a single puncture. METHODS AND MATERIALS: Clinically approved and post-mortem tested ACN-III biopsy core needles (14 gauge x 160 mm) with an automatic pistol device (Bard Magnum, Medical Device Technologies, Denmark) were used for probe sampling. The needles were navigated in gelatine/peas phantom, ex vivo porcine model and subsequently in two human bodies using a navigation system (MEM centre/ISTB Medical Application Framework, Marvin, Bern, Switzerland) with guidance frame and a CT (Emotion 6, Siemens, Germany). RESULTS: Biopsy of all peas could be performed within a single attempt. The average distance between the inserted needle tip and the pea centre was 1.4mm (n=10; SD 0.065 mm; range 0-2.3 mm). The targets in the porcine liver were also accurately punctured. The average of the distance between the needle tip and the target was 0.5 mm (range 0-1 mm). Biopsies of brain, heart, lung, liver, pancreas, spleen, and kidney were performed on human corpses. For each target the biopsy needle was only inserted once. The examination of one body with sampling of tissue probes at the above-mentioned locations took approximately 45 min. CONCLUSIONS: Post-mortem navigated biopsy can reliably provide tissue samples from different body locations. Since the continuous update of positional data of the body and the biopsy needle is performed using optical tracking, no control CT images verifying the positional data are necessary and no radiation exposure to the investigator need be taken into account. Furthermore, the number of needle insertions for each target can be minimized to a single one with the ex vivo proven adequate accuracy and, in contrast to conventional CT guided biopsy, the insertion angle may be oblique. Navigation for minimally invasive tissue sampling is a useful addition to post-mortem CT guided biopsy.
Resumo:
RATIONALE AND OBJECTIVES: A feasibility study on measuring kidney perfusion by a contrast-free magnetic resonance (MR) imaging technique is presented. MATERIALS AND METHODS: A flow-sensitive alternating inversion recovery (FAIR) prepared true fast imaging with steady-state precession (TrueFISP) arterial spin labeling sequence was used on a 3.0-T MR-scanner. The basis for quantification is a two-compartment exchange model proposed by Parkes that corrects for diverse assumptions in single-compartment standard models. RESULTS: Eleven healthy volunteers (mean age, 42.3 years; range 24-55) were examined. The calculated mean renal blood flow values for the exchange model (109 +/- 5 [medulla] and 245 +/- 11 [cortex] ml/min - 100 g) are in good agreement with the literature. Most important, the two-compartment exchange model exhibits a stabilizing effect on the evaluation of perfusion values if the finite permeability of the vessel wall and the venous outflow (fast solution) are considered: the values for the one-compartment standard model were 93 +/- 18 (medulla) and 208 +/- 37 (cortex) ml/min - 100 g. CONCLUSION: This improvement will increase the accuracy of contrast-free imaging of kidney perfusion in treatment renovascular disease.
Resumo:
The treatment of complex cerebrovascular or skull base pathological conditions necessitates a microsurgical blood flow preservation or augmentative revascularization procedure as either an adjunctive safety measure or a definitive treatment. The brain is susceptible to ischemia, and procedure-related risks can be minimized by the reduction of occlusion time or the use of a nonocclusive technique. The authors therefore analyzed the feasibility of an automatic device (C-Port xA, Cardica) designed for constructing an end-to-side anastomosis with or without flow interruption for a middle cerebral artery (MCA) bypass in a human cadaveric model and in an in vivo craniotomy simulation model.
Resumo:
BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) is generally performed using intra-procedural guidance by transoesophageal (TEE) or intracardiac (ICE) echocardiography. While TEE requires sedation or general anaesthesia, ICE is costly and adds incremental risk, and both imaging modalities lengthen the procedure. METHODS: A total of 825 consecutive patients (age 51 +/- 13 years; 58% male) underwent percutaneous PFO closure solely under fluoroscopic guidance, without intra-procedural echocardiography. The indications for PFO closure were presumed paradoxical embolism in 698 patients (95% cerebral, 5% other locations), an embolic event with concurrent aetiologies in 47, diving in 51, migraine headaches in 13, and other reasons in 16. An atrial septal aneurysm was associated with the PFO in 242 patients (29%). RESULTS: Permanent device implantation failed in two patients (0.2%). There were 18 procedural complications (2.2%), including embolization of the device or parts of it in five patients with successful percutaneous removal in all cases, air embolism with transient symptoms in four patients, pericardial tamponade requiring pericardiocentesis in one patient, a transient ischaemic attack with visual symptoms in one patient, and vascular access site problems in seven patients. There were no long-term sequelae. Contrast TEE at six months showed complete abolition of right-to-left shunt via PFO in 88% of patients, whereas a minimal, moderate or large residual shunt persisted in 7%, 3%, and 2%, respectively. CONCLUSIONS: This study confirms the safety and feasibility of percutaneous PFO closure without intra-procedural echocardiographic guidance in a large cohort of consecutive patients.
Resumo:
AIM: To explore the variability in pain response in preterm infants across time who received sucrose during routine heel stick. METHOD: Single group, exploratory repeated measures design. SETTING: Two tertiary level neonatal intensive care units (NICU) in Switzerland. SUBJECTS: Nine preterm infants born between 28 2/7 and 31 4/7 weeks of gestation during their first 14 days of life. MEASUREMENTS: Pain was assessed by the Bernese Pain Scale for Neonates (BPSN), the Premature Infant Pain Profile (PIPP) and the Visual Analogue Scale (VAS). Salivary cortisol was analysed. RESULTS: 72-94% of the variability was within-subject variability, indicating inconsistency of pain responses across the 5 heel sticks. Interrater agreement was highest during heel sticks 1-3 and decreased during heel stick 4 and 5, indicating a possible alteration of pain patterns. No significant differences in the amount of cortisol could be detected before and after the heel sticks (p = 0.55), indicating no stress-induced peak after the painful intervention. However, a general gradual decrease of cortisol levels across time could be detected. CONCLUSION: A high variability in pain response among preterm neonates across time could be described. Consistency of cortisol levels before and after the heel sticks could indicate the effectiveness of sucrose across time.