947 resultados para Echocardiography, Doppler, Color


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Borderline hypertension (BH) has been associated with an exaggerated blood pressure (BP) response during laboratory stressors. However, the incidence of target organ damage in this condition and its relation to BP hyperreactivity is an unsettled issue. Thus, we assessed the Doppler echocardiographic profile of a group of BH men (N = 36) according to office BP measurements with exaggerated BP in the cycloergometric test. A group of normotensive men (NT, N = 36) with a normal BP response during the cycloergometric test was used as control. To assess vascular function and reactivity, all subjects were submitted to the cold pressor test. Before Doppler echocardiography, the BP profile of all subjects was evaluated by 24-h ambulatory BP monitoring. All subjects from the NT group presented normal monitored levels of BP. In contrast, 19 subjects from the original BH group presented normal monitored BP levels and 17 presented elevated monitored BP levels. In the NT group all Doppler echocardiographic indexes were normal. All subjects from the original BH group presented normal left ventricular mass and geometrical pattern. However, in the subjects with elevated monitored BP levels, fractional shortening was greater, isovolumetric relaxation time longer, and early to late flow velocity ratio was reduced in relation to subjects from the original BH group with normal monitored BP levels (P<0.05). These subjects also presented an exaggerated BP response during the cold pressor test. These results support the notion of an integrated pattern of cardiac and vascular adaptation during the development of hypertension.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study describes an auxiliary tool in the diagnosis of left ventricular (LV) segmental wall motion (WM) abnormalities based on color-coded echocardiographic WM images. An artificial neural network (ANN) was developed and validated for grading LV segmental WM using data from color kinesis (CK) images, a technique developed to display the timing and magnitude of global and regional WM in real time. We evaluated 21 normal subjects and 20 patients with LVWM abnormalities revealed by two-dimensional echocardiography. CK images were obtained in two sets of viewing planes. A method was developed to analyze CK images, providing quantitation of fractional area change in each of the 16 LV segments. Two experienced observers analyzed LVWM from two-dimensional images and scored them as: 1) normal, 2) mild hypokinesia, 3) moderate hypokinesia, 4) severe hypokinesia, 5) akinesia, and 6) dyskinesia. Based on expert analysis of 10 normal subjects and 10 patients, we trained a multilayer perceptron ANN using a back-propagation algorithm to provide automated grading of LVWM, and this ANN was then tested in the remaining subjects. Excellent concordance between expert and ANN analysis was shown by ROC curve analysis, with measured area under the curve of 0.975. An excellent correlation was also obtained for global LV segmental WM index by expert and ANN analysis (R² = 0.99). In conclusion, ANN showed high accuracy for automated semi-quantitative grading of WM based on CK images. This technique can be an important aid, improving diagnostic accuracy and reducing inter-observer variability in scoring segmental LVWM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Osteoprotegerin (OPG) regulates bone mass by inhibiting osteoclast differentiation and activation, and plays a role in vascular calcification. We evaluated the relationship between osteoprotegerin levels and inflammatory markers, atherosclerosis, and mortality in patients with stages 3-5 chronic kidney disease. A total of 145 subjects (median age 61 years, 61% men; 36 patients on hemodialysis, 55 patients on peritoneal dialysis, and 54 patients with stages 3-5 chronic kidney disease) were studied. Clinical characteristics, markers of mineral metabolism (including fibroblast growth factor-23 [FGF-23]) and inflammation (high-sensitivity C-reactive protein [hsCRP] and interleukin-6 [IL-6]), and the intima-media thickness (IMT) in the common carotid arteries were measured at baseline. Cardiac function was assessed by color tissue Doppler echocardiography. After 36 months follow-up, the survival rate by Kaplan-Meier analysis was significantly different according to OPG levels (χ2=14.33; P=0.002). Increased OPG levels were positively associated with IL-6 (r=0.38, P<0.001), FGF-23 (r=0.26, P<0.001) and hsCRP (r=0.0.24, P=0.003). In addition, OPG was positively associated with troponin I (r=0.54, P<0.001) and IMT (r=0.39, P<0.0001). Finally, in Cox analysis, only OPG (HR=1.07, 95%CI=1.02-1.13) and hsCRP (HR=1.02, 95%CI=1.01-1.04) were independently associated with increased risk of death. These results suggested that elevated levels of serum OPG might be associated with atherosclerosis and all-cause mortality in patients with chronic kidney disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En dépit du nombre croissant d’études cliniques sur le canal artériel (CA), des failles méthodologiques entretiennent plusieurs incertitudes concernant l’efficacité et la sécurité des traitements chez les bébés nés prématurés. L’objectif de cette recherche était de comparer les concentrations de prostaglandine E2 (PGE2) et les mesures du flux mésentérique par échographie Doppler chez les enfants nés prématurément et ayant un canal artériel traité à l’ibuprofène par voie intraveineuse ou entérale, en utilisant la méthodologie randomisée contrôlée et à double insu. Dans notre étude pilote, 20 nouveau-nés prématurés de moins de 34 semaines ayant un CA symptomatique confirmé par échocardiographie, furent randomisés au traitement à l’ibuprofène par voie intraveineuse ou entérale. La voie d’administration fut maintenue à l’insu de l’équipe traitante, des cardiologues et des investigateurs. Des dosages des prostaglandines plasmatiques ont été mesurés avant le début du traitement ainsi que 3, 24 et 48 h après le début du traitement. Les mesures du flux mésentérique ont été effectuées avant le traitement à l’ibuprofène ainsi que 1 h et 3 h après le traitement. Nous avons démontré à partir de nos observations que les niveaux plasmatiques de prostaglandines E2 diminuent chez les patients ayant répondu au traitement à l’ibuprofène, indépendamment de la voie d’administration. Nous n’avons pas observé de changement dans l’évolution des dosages de PGE2 chez les patients qui n’ont pas répondu au traitement. Les paramètres mesurés par échographie Doppler au niveau de l’artère mésentérique supérieure n’étaient pas affectés par la voie d’administration du traitement à l’ibuprofène, intraveineuse ou entérale. La présente étude suggère ainsi que le traitement du CA par ibuprofène intraveineux ou entéral n’influe pas sur le flux sanguin mesuré par échographie Doppler. La baisse de la prostaglandine E2 coïncide avec la fermeture du CA, et son dosage pourrait jouer un rôle dans la gestion du traitement. Nous avons démontré la faisabilité d’une étude clinique randomisée à double insu dans le traitement du canal artériel; une méthodologie qui devrait désormait être employé dans la recherche clinique sur les traitements de la persistance du CA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nous proposons une nouvelle méthode pour quantifier la vorticité intracardiaque (vortographie Doppler), basée sur l’imagerie Doppler conventionnelle. Afin de caractériser les vortex, nous utilisons un indice dénommé « Blood Vortex Signature (BVS) » (Signature Tourbillonnaire Sanguine) obtenu par l’application d’un filtre par noyau basé sur la covariance. La validation de l’indice BVS mesuré par vortographie Doppler a été réalisée à partir de champs Doppler issus de simulations et d’expériences in vitro. Des résultats préliminaires obtenus chez des sujets sains et des patients atteints de complications cardiaques sont également présentés dans ce mémoire. Des corrélations significatives ont été observées entre la vorticité estimée par vortographie Doppler et la méthode de référence (in silico: r2 = 0.98, in vitro: r2 = 0.86). Nos résultats suggèrent que la vortographie Doppler est une technique d’échographie cardiaque prometteuse pour quantifier les vortex intracardiaques. Cet outil d’évaluation pourrait être aisément appliqué en routine clinique pour détecter la présence d’une insuffisance ventriculaire et évaluer la fonction diastolique par échocardiographie Doppler.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A função cardíaca é fortemente condicionada pela mioarquitectura do coração, pelo que o estudo da relação morfologia-função ventricular nos mamíferos é de grande importância no diagnóstico e tratamento de patologias cardíacas. O cálculo dos volumes cardíacos durante todo o ciclo cardíaco tem uma importância fundamental para o estudo da função ventricular e para a definição dos padrões hemodinâmicos. Foi objectivo deste trabalho, o estudo de índices de função sistólica ventricular esquerda, em 25 cães (Cannis lupus familiaris), através da utilização de diferentes técnicas ecocardiográficas, como o Modo M, ecocardiografia bidimensional, Doppler tecidular e a ecocardiografia de contraste. Foi utilizado contraste ultrasonográfico, para melhorar a definição do endocárdio e possibilitar maior rigor no cálculo dos volumes ventriculares, e na avaliação da função ventricular sisto-diastólica global e regional. Os resultados apresentados foram sujeitos a tratamento estatístico com software Analyze-it. O Doppler tecidular mostrou ser um método robusto para avaliar a função sistólica. A ecocardiografia de contraste permitiu não só obter uma melhor definição endocárdica, como obter valores de fracção de ejecção com diferença estatisticamente significativa. Como os três métodos utilizados avaliam diferentes aspectos da função sistólica, função ventricular radial, circunferencial e longitudinal, não podem ser comparados directamente entre si.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AZEVEDO, George Dantas de et al. Raloxifene therapy does not affect uterine blood flow in postmenopausal women: a transvaginal Doppler study. Maturitas, Amsterdam, v.47, n.3, p.195-200, 2004

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess structural and functional cardiac changes in asymptomatic pregnant women with chronic arterial hypertension (CAH). METHODS: One hundred pregnant women with CAH underwent conventional Doppler echocardiography. The Student t test was used to compare them with 29 normotensive pregnant women (NT) in their third gestational trimester. RESULTS: Systolic (SBP; mmHg) and diastolic (DBP; mmHg) blood pressure values were higher (p<0.001) in the CAH pregnant women (SBP: 139±19 and DBP: 92± 18) as compared with those of the NT group (SBP: 112±10 and DBP: 74±9). A significant enlargement of the left atrium (4.10±0.48 cm vs 3.6±0.3 cm; p<0.001) and of the left ventricular normalized mass (59.6±19.7 g/cm2,7 vs 41.9±3.4 g/cm2,7; p<0.001) was observed. Cardiac output (CO, L/min) and systolic volume (SV, mL) were significantly higher in the CAH group (CO: 6.0±1.54 vs 4.9±2.1, p<0.01; SV: 77.3±19.8 vs 56.5±25.8, p<0.001). CONCLUSION: Chronic hypertensive pregnant women have structural and functional cardiac changes that justify routine cardiologic assessment, even in the absence of cardiopulmonary symptoms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objetivo: Avaliar o efeito do tartarato de brimonidina a 0,2% tópico, instilado de 12/12 horas, na circulação retrobulbar em pacientes portadores de glaucoma. Métodos: Foram estudados os 2 olhos de 16 pacientes portadores de glaucoma primário de ângulo aberto e glaucoma crônico de ângulo estreito com iridotomia. Usando o Doppler colorido foram avaliados: velocidade sistólica máxima, velocidade diastólica final e índice de resistência das artéria central da retina, artéria ciliar posterior curta temporal e artéria oftálmica. As avaliações foram feitas antes e depois do uso da brimonidina. Resultados: O tartarato de brimonidina a 0,2% aumentou significativamente a velocidade sistólica máxima (28,24 para 34,23 cm/seg) e velocidade diastólica final (6,62 para 8,10 cm/seg) no olho direito e reduziu o índice de resistência (0,75 para 0,71) no olho esquerdo da artéria oftálmica. Conclusão: O tartarato de brimonidina 0,2% 2x/dia aumentou significativamente a velocidade sistólica máxima e velocidade diastólica final e reduziu índice de resistência da artéria oftálmica de pacientes glaucomatosos. Este efeito sugere que a brimonidina pode beneficiar pacientes glaucomatosos com insuficiência vascular na cabeça do nervo óptico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A perfusão total do fígado e suas contribuições relativas, pelo sistema portal e pela artéria hepática, podem estar alteradas por vários processos hepáticos, como doença hepato-celular difusa, neoplasia e shunts intra-hepáticos. O estudo do comportamento do fluxo sangüíneo nos vasos do fígado por meio da ultra-sonografia Doppler tem demonstrado que este é um método viável não-invasivo e de grande auxílio, principalmente na avaliação da hemodinâmica portal. São duas as modalidades de ultra-sonografia Doppler com maior aplicação na rotina para avaliação de fluxo nos vasos abdominais, o Doppler espectral e o Doppler colorido. Na doença hepática crônica, ocorre alteração da complacência hepática devido à fibrose ou à cirrose, as quais acarretam alterações vasculares, levando ao aumento da pressão venosa portal. As principais indicações desse exame são os casos em que há suspeita de hipertensão portal. A hemodinâmica portal é avaliada pela mensuração de sua área, da velocidade média, do volume de fluxo no vaso e do índice de congestão portal. Esta revisão de literatura tem como objetivo descrever os princípios físicos básicos da ultra-sonografia Doppler e sua aplicação na avaliação da hemodinâmica portal nos cães.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a estrutura e função do ventrículo esquerdo (VE) e a rigidez arterial em portadores de diabetes mellitus tipo II. MÉTODOS: Foram estudados 13 doentes diabéticos de ambos os sexos (55±8 anos) sem outras doenças. A estrutura e função do VE foram avaliadas por meio de ecodopplercardiografia associada à monitorização não invasiva da pressão arterial (PA). Os resultados foram comparados aos obtidos em grupo de indivíduos normais de mesma idade (n=12). RESULTADOS: Não houve diferenças entre os grupos quanto a PA diastólica, dimensões das câmaras esquerdas e índices de função sistólica e diastólica. Os pacientes diabéticos apresentaram índice de massa do VE (101±10 vs 80±14g/m²; p<0,001) e índice de rigidez arterial sistêmica (0,86±0,26 vs 0,69±0,19mmHg/mL; p<0,05) significantemente maiores que os controles. CONCLUSÃO: O diabetes mellitus está associado a aumento da rigidez arterial sistêmica e esse fator poderia contribuir para seus efeitos adversos sobre o VE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.