987 resultados para ESR DOSIMETRY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to validate the Geant4 toolkit for dosimetry applications, simulations were performed to calculate conversion coefficients h(10, alpha) from air kerma free-in-air to personal dose equivalent Hp(10, a). The simulations consisted of two parts: the production of X-rays with radiation qualities of narrow and wide spectra, and the interaction of radiation with ICRU tissue-equivalent and ISO water slab phantoms. The half-value layers of the X-ray spectra obtained by simulation were compared with experimental results. Mean energy, spectral resolution, half-value layers and conversion coefficients were compared with ISO reference values. The good agreement between results from simulation and reference data shows that the Geant4 is suitable for dosimetry applications which involve photons with energies in the range of ten to a few hundreds of keV. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the development of the highly sensitive material Al(2)O(3):C, personal dosimetry using optically stimulated luminescence (OSL) has been continuously adopted in place of thermoluminescence dosimeters (TLD) by different countries (e.g. USA and Japan). In order to use a dosimetric system in Brazil it is necessary to develop a protocol and to fulfill performance and type tests in accordance with the accreditation program approved by the responsible governmental committee. This paper presents a proposal for an accreditation program for OSL personal dosimetry using a commercial dosimetric system, including tests that follow the same rules as applied to TLD and film dosimetry. The experimental results are within the reliability interval and in accordance to the expected behavior. A new test concerning re-analysis of exposed badges is also proposed. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of paramagnetic species in the aqueous ring opening metathesis polymerizations of the exo,exo-7-oxabicyclo[2.2.1]hept-5-ene-2,3-dicarboxylic acid monomer with RuCl(3) and K(2)[RuCl(5)H(2)O] compounds was studied using ESR techniques. It was observed that the intensities of the Ru(III) signals in the ESR spectra decrease on the time scale of the induction period so that the ROMP can take place. The intensity of the Ru(III) signal almost disappeared 50 min after reacting with K(2)[RuCl(5)H(2)O] and after 100 mm in the case of RuCl(3). Reactions of the cis-[Ru(NH(3))(4)(H(2)O)(2)](tfms)(3) and [Ru(NH(3))(5)H(2)O](tfms)(3) complexes with the monomer and different organic compounds representing the organic functions in the monomer (furan, norbornene, but-2-ene-1,4-diol and formic, acetic, oxalic and maleic acids) were also monitored by ESR and UV/vis spectra. It was deduced that the organic acids provide the disappearance of the Ru(III) signal. The proton NMR relaxation times of the residual water in D(2)O for reactions with oxalic acid suggested that the presence of paramagnetic ions in the solution decreases along with

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the major advances in PDT is the use of 5-aminolevulinic acid (ALA) to induce the production of an enclogenous photosensitizer inside the cells using intracellular enzymatic pathways. ALA is the first intermediate in heme biosynthesis and a precursor of the protoporphyrin IX (PpIX). When activated by light, this efficient photosensitizer accumulated in the target cells can produce cytotoxicity. The aim of this study was to find the best conditions for cell killing using ALA to temporarily increase the concentration of PpIX in two cell lines. It was shown that a considerable efflux of synthesized PpIX occurs. Since this efflux is time-dependent, it is essential to know the optimum time for irradiation after ALA administration. So, the efflux of PpIX from the cells is an important parameter to be considered for ALA-PDT dosimetry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several chronic bioassays have been conducted in multiple strains of mice in which various concentrations of arsenate or arsenite were administered in the drinking water without a tumorigenic effect. However, one study (Ng et al., 1999) reported a significant increase in tumor incidence in C57Bl/6J mice exposed to arsenic in their drinking water throughout their lifetime, with no tumors reported in controls. A physiologically based pharmacokinetic model for arsenic in the mouse has previously been developed (Gentry et al., 2004) to investigate potential differences in tissue dosimetry of arsenic species across various strains of mice. Initial results indicated no significant differences in blood, liver, or urine dosimetry in B6C3F1 and C57Bl/6 mice for acute or subchronic exposure. The current work was conducted to compare model-predicted estimates of tissue dosimetry to additional kinetic information from the (C57Bl/6 x CBA)F1 and TgAc mouse. The results from the current modeling indicate that the pharmacokinetic parameters derived based on information in the B6C3F1 mouse adequately describe the measured concentrations in the blood/plasma, liver, and urine of both the (C57Bl/6 x CBA)F1 and TgAc mouse, providing further support that the differences in response observed in the chronic bioassays are not related to strain-specific differences in pharmacokinetics. One significant finding was that no increases in skin or lung concentrations of arsenic species in the (C57Bl/6 x CBA)F1 strain were observed following administration of low concentrations (0.2 or 2 mg/L) of arsenate in the drinking water, even though differences in response in the skin were reported. These data suggest that pharmacodynamic changes may be observed following exposure to arsenic compounds without an observable change in tissue dosimetry. These results provided further indirect support for the existence of inducible arsenic efflux in these tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new versatile computer controlled electrochemlcal/ESR data acquisition system has been developed for the Investigation of short-lived radicals with life-times of 20 milliseconds and greater, Different computer programs have been developed to monitor the decay of radicals; over hours or minutes, seconds or milliseconds. Signal averaging and Fourier smoothing is employed in order to improve the signal to noise ratio. Two microcomputers are used to control the system, one home-made computer containing the M6800 chip which controls the magnetic field, and an IBM PC XT which controls the electrochemistry and the data acquisition. The computer programs are written in Fortran and C, and call machine language subroutines, The system functions by having the radical generated by an electrochemical pulse: after or during the pulse the ESR data are collected. Decaying radicals which have half-lives of seconds or greater have their spectra collected in the magnetic field domain, which can be swept as fast as 200 Gauss per second. The decay of the radicals in the millisecond region is monitored by time-resolved ESR: a technique in which data is collected in both the time domain and in the magnetic field domain. Previously, time-resolved ESR has been used (without field modulation) to investigate ultra-short-lived species with life-times in the region of only a few microseconds. The application of the data acquisition system to chemical systems is illustrated. This is the first time a computer controlled system whereby the radical is generated by electrochemical means and subsequently the ESR data collected, has been developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of subfossil material in bottom sediments of Couve Island, Ubatuba region, São Paulo State, is confirmed. The analyzed material consists of a bivalve shell that was dated by the electron spin resonance technique. By the additive irradiation method an archaeological absorbed dose of (25 +/- 5) Gy was obtained and calibration with other dating works in the same area allows the inference of an age of (25 +/- 5) x 10(2) years. The importance of this finding and its paleoecological implications could contribute to elucidating the nature of short-term environmental changes in the Brazilian coastline during the Holocene, as well as becoming an important tool to the understanding of the distribution and biological aspects of the bivalve fauna. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutron dosimetry using natural uranium and thorium thin films makes possible that mineral dating by the fission-track method can be accomplished, even when poor thermalized neutron facilities are employed. In this case, the contributions of the fissions of (235)U, (238)U and (232)Th induced by thermal, epithermal and fast neutrons to the population of tracks produced during irradiation are quantified through the combined use of natural uranium and thorium films.If the Th/U ratio of the sample is known, only one irradiation (where the sample and the films of uranium and thorium are present) is necessary to perform the dating. However, if that ratio is unknown, it can be determined through another irradiation where the mineral to be dated and both films are placed inside a cadmium box.Problems related with film manufacturing and calibration are discussed. Special attention is given to the utilization of thin films having very low uranium content. The problems faced suggest that it may be better to substitute these films by uranium doped standard glasses calibrated with thicker uranium films (thickness greater than 1.5 x 10(13) mu m).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minidosimeters of L-alanine and 2-methylalanine (2MA) were prepared and tested as potential candidates for small radiation field dosimetry. To quantify the free radicals created by radiation a K-Band (24 GHz) EPR spectrometer was used. X-rays provided by a 6 MV clinical linear accelerator were used to irradiate the minidosimeters in the dose range of 0.5-30 Gy. The dose-response curves for both radiation sensitive materials displayed a good linear behavior in the dose range indicated with 2MA being more radiation sensitive than L-alanine. Moreover, 2MA showed a smaller LLD (lower limit detection) value. The proposed system minidosimeter/K-Band spectrometer was able to detect 10 Gy EPR spectra with good signal-to-noise ratio (S/N). The overall uncertainty indicates that this system shows a good performance for the detection of dose values of 20 Gy and above, which are dose values typically used in radiosurgery treatments. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The IRSL and TL responses of three different feldspar crystals have been analysed. TL measurements were taken in the ultraviolet UV (290-370 nm) and the visible VIS (340-610 nm) regions of the spectrum. For the UV region and for a natural sample, peaks were observed at 283, 287 and 310 degrees C for grey, white and pink crystals, respectively. For samples irradiated after prior preheating, it was noted that TL peaks occurred at about 200 degrees C for all the samples; irradiation with high doses above 500 Gy induced the formation of one additional peak at 170 degrees C. The VIS region results were similar to those for the UV. ESR experiments have been developed to verify the influence of radiation and heat treatments on the centres and preliminary results showed great variation in the intensities of [TiO(4)](-), Al-O(-)-Al and Fe(3+) centres. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron spin resonance of Eu(2+) (4f(7), S=7/2) in a La hexaboride (LaB(6)) single crystal shows a single anisotropic Dysonian resonance. From the observed negative g shift of the resonance, it is inferred that the Eu(2+) ions are covalent exchange coupled to the B 2p-like host conduction electrons. From the anisotropy of the spectra (linewidth and field for resonance), we found that the S ground state of Eu(2+) ions experience a cubic crystal field of a negative fourth order crystal field parameter (CFP), b(4)=-11.5(2.0) Oe, in agreement with the negative fourth order CFP, A(4), found for the non-S ground state R hexaborides. These results support covalency as the dominant contribution to the fourth order CFP for the whole R hexaboride family.