986 resultados para ECOGRAFIA DOPPLER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Port-wine stains (PWS) are malformations of capillaries in 0.3% of newborn children. The treatment of choice is by pulsed dye LASER (PDL), and requires several sessions. The efficacy of this treatment is at present evaluated on the basis of clinical inspection and of digital photographs taken throughout the treatment. LASER-Doppler imaging (LDI) is a noninvasive method of imaging the perfusion of the tissues by the microcirculatory system (capillaries). The aim of this paper is to demonstrate that LDI allows a quantitative, numerical evaluation of the efficacy of the PDL treatment of PWS. METHOD: The PDL sessions were organized according to the usual scheme, every other month, from September 1, 2012, to September 30, 2013. LDI imaging was performed at the start and at the conclusion of the PDL treatment, and simultaneously on healthy skin in order to obtain reference values. The results evidenced by LDI were analyzed according to the "Wilcoxon signed-rank" test before and after each session, and in the intervals between the three PDL treatment sessions. RESULTS: Our prospective study is based on 20 new children. On average, the vascularization of the PWS was reduced by 56% after three laser sessions. Compared with healthy skin, initial vascularization of PWS was 62% higher than that of healthy skin at the start of treatment, and 6% higher after three sessions. During the 2 months between two sessions, vascularization of the capillary network increased by 27%. CONCLUSION: This study shows that LDI can demonstrate and measure the efficacy of PDL treatment of PWS in children. The figures obtained when measuring the results by LDI corroborate the clinical assessments and may allow us to refine, and perhaps even modify, our present use of PDL and thus improve the efficacy of the treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä insinöörityössä otettiin käyttöön VTI Technologies Oy:lle hankittu laser Doppler - vibrometri, joka mittaa tärinää perustuen valon Dopplerin siirtymään. Työn tavoitteena oli perehtyä mittauslaitteistoon, muodostaa sille näytteenottolaitteisto ja käytännössä arvioida sen kyvykkyyttä mitata tärinää ja tuottaa uutta informaatiota. Työn teoreettisessa osuudessa perehdytään laser Doppler -vibrometrin teknologiaan ja toimintaperiaatteeseen sekä värähtelevien systeemien dynamiikkaan ja mallintamiseen. Työn käytännön osuuden suorittamiseksi perehdyttiin myös tärinätestauslaitteiston toimintaan, analogiasignaalin näytteenottoon sekä diskreettiin Fourier-muunnokseen perustuvaan signaalin spektrianalyysiin. Työssä käsitellään myös laser-mittauksen kohinalähteitä ja spektrianalyysin virhelähteitä. Työn käytännön osuudessa ohjelmoitiin Labview-mittausohjelmisto näytteenottolaitteistolle. Mittausohjelmistolla voidaan näytteistää vibrometrin mittaussignaalia ja muodostaa sen taajuusspektri. Mittauskohteita tässä työssä olivat kulmakiihtyvyystäryttimen mekaanisen liikkeen mittaus ja elementtikiekkosahan terän värähtelyjen mittaus. Mittaustulokset kulmakiihtyvyystäryttimestä osoittivat sen mekaanisen liikkeen säröytyvän voimakkaasti, johtuen todennäköisesti sen testialustan rakenteesta. Testialustan rakennetta tullaan kehittämään ja mittaukset toistetaan. Mittaustuloksiin elementtikiekkosahasta tuli suhtautua epäillen, koska mittaussignaalin intensiteetti oli erittäin heikko. Mittausten onnistuminen Laser Doppler -vibrometrillä edellyttää riittävää mittauskohteesta takaisinheijastuneen laser-valon intensiteettiä. Mittaustulokset osoittivat laser Doppler -vibrometrin olevan hyödyllinen työkalu tutkivassa tärinämittauksessa. Mittauskohteet, joiden pinta heijastaa huonosti valoa ja joihin ei voi asentaa erityistä heijastavaa teippiä, ovat kuitenkin haaste ja asettavat rajoituksen laser Doppler -vibrometrin käyttömahdollisuuksille. Tämän työn mittaustuloksia voidaan käyttää kulmakiihtyvyystäryttimen uusintamittausten vertailukohtana, kun arvioidaan kehitystyön onnistumista. Tätä työtä voidaan käyttää myös laser Doppler -vibrometrin ohjekirjana tärinämittauksissa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compute the shift in the frequency of the spin resonance in a solid that rotates in the field of a circularly polarized electromagnetic wave. Electron-spin resonance, nuclear magnetic resonance, and ferromagnetic resonance are considered. We show that contrary to the case of the rotating LC circuit, the shift in the frequency of the spin resonance has strong dependence on the symmetry of the receiver. The shift due to rotation occurs only when rotational symmetry is broken by the anisotropy of the gyromagnetic tensor, by the shape of the body or by magnetocrystalline anisotropy. General expressions for the resonance frequency and power absorption are derived and implications for experiment are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ANTECEDENTES: A diversidade de técnicas de mensuração esplênica pelo ultra-som Doppler (US Doppler), a falta de valores biométricos e dopplervelocimétricos dificultam a avaliação deste órgão e de suas características hemodinâmicas. OBJETIVO: Estabelecer padrões biométricos e hemodinâmicos por US-Doppler em indivíduos adultos sadios. MATERIAIS E MÉTODOS: Estudo prospectivo de 44 indivíduos sadios, sendo 19 do sexo masculino e 25 do sexo feminino, na faixa etária de 23 a 60 anos (37,4 ± 9,6). Morfometria (US modo-B): baço: eixos longitudinal (L), transversal (T) e ântero-posterior (AP); diâmetro da artéria esplênica (DAE) e diâmetro da veia esplênica (DVE). Índices morfométricos do baço: uniplanar (IBU), biplanar (IBB) e volume esplênico (VE). Dopplervelocimetria (US Doppler): a) artéria esplênica: velocidade de pico sistólico (VPS), média das velocidades máximas de fluxo (TAMax); índices de impedância vascular: índice de resistividade (IR); índice de pulsatilidade (IP); b) veia esplênica: média das velocidades máximas de fluxo (TAMax). RESULTADOS: Morfometria: L = 9,3 ± 1,3 cm; T= 3,9 ± 0,7 cm; AP = 8,4 ± 1,2 cm; DAE = 0,3 ± 0,07 cm; DVE: 0,5 ± 0,12 cm. Índices morfométricos do baço: IBU = 33,5 ± 9,9; IBB = 36,7 ± 10,3; VE = 164,3 ± 62,9 cm³. Dopplervelocimetria: a) artéria esplênica: VPS = 59,8 ± 23,6 cm/s; TAMax = 40,2 ± 15,9 cm/s; IP = 0,86 ± 0,30; IR = 0,55 ± 0,09; b) veia esplênica: TAMax = 16,8 ± 8,3 cm/s. CONCLUSÃO: Relato de valores biométricos e dopplervelocimétricos do baço em indivíduos sadios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo propôs-se a revisar os aspectos relevantes da anatomia, técnica de exame e achados de imagens, com o objetivo de auxiliar o radiologista no diagnóstico diferencial frente às afecções músculo-tendinosas do ombro. Foram realizadas 34 ultra-sonografias da região do ombro, no período de janeiro a dezembro de 2001. A avaliação foi realizada com transdutores de alta freqüência (7,5-10 MHz). O exame foi normal em 23% dos pacientes (oito casos). Dos 26 casos alterados, observaram-se oito com ruptura total (30%), cinco com ruptura parcial (19%), dez com tendinopatia (38%), um com tendinopatia calcificada (3%), um com tenossinovite bicipital (3%) e um com tendinopatia associada a artrite gotosa (3%). A falta de experiência e de conhecimento das principais alterações que acometem o ombro é um dos principais pontos limitantes do diagnóstico ultra-sonográfico das lesões do ombro. Portanto, o estudo dessas alterações deve ser realizado amplamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ultra-sonografia e o Doppler representaram grande marco no diagnóstico da hipertensão portal. Este fato decorre do aspecto não-invasivo destes métodos, possibilitando o estudo do fígado, do baço e da circulação esplâncnica. Neste artigo os autores discutem alguns aspectos importantes avaliados pela ultra-sonografia e pelo Doppler na avaliação da hipertensão portal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A anastomose portossistêmica intra-hepática transjugular (TIPS) compreende a técnica mais recente e mais popular para o alívio da hipertensão portal sintomática, especialmente para os casos com varizes e hemorragia digestiva alta, e menos comumente para o tratamento da ascite refratária. Os TIPS podem apresentar complicações após sua colocação, como as estenoses e oclusões. A ultra-sonografia e o Doppler permitem o estudo dos TIPS de uma forma não invasiva. Neste artigo os autores relatam os achados recentes à ultra-sonografia e ao Doppler nos casos de funcionamento normal e anormal (estenoses/oclusões) dos TIPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a capacidade da ultra-sonografia com Doppler colorido em caracterizar a vascularização de carcinomas sólidos da mama e em correlacionar padrões de vascularização com o tamanho, estádio e grau histológico destes tumores. MATERIAIS E MÉTODOS: Sessenta e seis carcinomas da mama foram estudados com Doppler colorido. As características morfológicas e fluxométricas foram avaliadas antes da biópsia e correlações com aspectos clínicos, histopatólogicos e estadiamento tumoral foram avaliadas estatisticamente. RESULTADOS: Cinqüenta e dois tumores (79%) apresentaram vasos penetrantes, 63 (95%) mostraram vasos periféricos, 33 (50%) tinham vasos centrais e em dois tumores (3%) não foi observada vascularização. O número médio de vasos nos tumores foi de 11,9 ± 7,7 e na mama contralateral foi de 1,7 ± 2,5. Nenhuma associação foi evidenciada com as características histológicas. A distribuição dos vasos foi diferente em dois grupos de tumores. Não houve diferença na velocidade diastólica, na resistência e no índice de pulsatilidade dos tumores e da mama contralateral. A velocidade sistólica nos tumores foi de 11,74 ± 0,96 e na mama contralateral foi de 9,45 ± 0,55. O número de vasos aumentou com a progressão do estadiamento dos tumores. CONCLUSÃO: O padrão vascular dos carcinomas da mama identificado pelo Doppler colorido deve ser considerado com potencial característica importante na avaliação pré-operatória destes tumores, em conjunto com outros fatores prognósticos como o tamanho tumoral e o estádio da doença.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler"). Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As malformações arteriovenosas do útero são entidades raras. Sua forma de apresentação clínica é muito diversa, devendo o ginecologista e o imaginologista estar atentos para esta possibilidade diagnóstica, para estabelecer o tratamento de forma precisa e rápida. O presente artigo visa mostrar um caso de malformação arteriovenosa uterina adquirida após doença trofoblástica gestacional, cujo diagnóstico foi bem estabelecido por meio da ultra-sonografia com Doppler colorido e correlação com angiorressonância magnética.