919 resultados para Disseminated Intravascular Coagulation
Resumo:
Although reactive hyperemia index (RHI) predicts future coronary events, associations with intravascular ultrasound (IVUS)-assessed coronary plaque structure have not been reported. This study therefore investigated associations between RHI and IVUS-assessed coronary plaques. In 362 patients RHI was measured by noninvasive peripheral arterial tonometry and coronary plaque components (fibrous, fibrofatty, necrotic core, and dense calcium) were identified by IVUS in 594 vessel segments of the left anterior descending, circumflex, and/or right coronary arteries. RHI values <1.67 were considered abnormal. Analysis of variance was used to detect independent associations between RHI and plaque composition. Patients with an abnormal RHI had greater plaque burden (41% vs 39% in patients with normal RHI, p = 0.047). Compared to patients with normal RHI, plaque of patients with abnormal RHI had more necrotic core (21% vs 17%, p <0.001) and dense calcium (19% vs 15%, p <0.001) and less fibrous (49% vs 54%, p <0.001) and fibrofatty (11% vs 14%, p = 0.002) tissue. After adjustment for age, gender, cardiovascular risk factors, and drug therapy, abnormal RHI remained significantly associated with fibrous (F ratio 14.79, p <0.001), fibrofatty (F ratio 5.66, p = 0.018), necrotic core (F ratio 14.47, p <0.001), and dense calcium (F ratio 10.80, p = 0.001) volumes. In conclusion, coronary artery plaques of patients with abnormal RHI had a larger proportion of necrotic core and dense calcium. The association of an abnormal RHI with a plaque structure that is more prone to rupture may explain why these patients exhibit a greater risk of coronary events.
Resumo:
For the examination of psychological stress effects on coagulation, the Dill and Costill correction (DCC) for hemoconcentration effects has been used to adjust for stress-induced plasma volume changes. Although the correction is appropriate for adjusting concentrations of various large blood constituents, it may be inappropriate for time-dependent or functional coagulation assays. Two new plasma reconstitution techniques for correcting hemoconcentration effects on stress-induced changes in coagulation were compared with the DCC.
Resumo:
Background The evaluation of the hepatic parenchyma in patients with chronic liver disease is important to assess the extension, localization and relationship with adjacent anatomical structures of possible lesions. This is usually performed with conventional abdominal ultrasound, CT-scan or magnetic resonance imaging. In this context, the feasibility and the safety of intravascular ultrasound in the liver have not been assessed yet. Methods We tested the safety and performance of an intracardiac echography (ICE) catheter applied by a transjugular approach into the hepatic veins in patients with chronic liver disease undergoing hepatic hemodynamic measurements. Results Five patients were enrolled in this pilot study. The insertion of the ICE catheter was possible into the right and middle, but not into the left hepatic vein. The position of the ICE was followed using fluoroscopy and external conventional ultrasound. Accurate imaging of focal hepatic parenchymal lesions, Doppler ultrasound of surrounding blood vessels and assessment of liver surface and ascites were achieved without complications. Conclusions This study demonstrated that a diagnostic approach using an ICE device inserted in the hepatic veins is feasible, safe and well tolerated. However, it remains for the moment only an experimental investigative tool. Whether ICE adds further information regarding parenchymal lesions and associated vascular alterations as compared to other techniques, needs additional investigation.
Resumo:
New oral anticoagulants promise to overcome essential drawbacks of traditional substances. They have a predictable therapeutic effect, a wide therapeutic window, only limited interaction with food and drugs and can be administered p.o. with a fixed dose. On the other hand, knowledge on the laboratory management of new anticoagulants is limited. In the present article we discuss possible indications and available assays for monitoring of Rivaroxaban, Apixaban and Dabigatran. Furthermore, we discuss interpretation of routine coagulation tests during therapy with these new drugs.
Resumo:
Background Numerous interactions between the coagulation and complement systems have been shown. Recently, links between coagulation and mannan-binding lectin-associated serine protease-1 (MASP-1) of the complement lectin pathway have been proposed. Our aim was to investigate MASP-1 activation of factor XIII (FXIII), fibrinogen, prothrombin, and thrombin-activatable fibrinolysis inhibitor (TAFI) in plasma-based systems, and to analyse effects of MASP-1 on plasma clot formation, structure and lysis. Methodology/Principal Findings We used a FXIII incorporation assay and specific assays to measure the activation products prothrombin fragment F1+2, fibrinopeptide A (FPA), and activated TAFI (TAFIa). Clot formation and lysis were assessed by turbidimetric assay. Clot structure was studied by scanning electron microscopy. MASP-1 activated FXIII and, contrary to thrombin, induced FXIII activity faster in the Val34 than the Leu34 variant. MASP-1-dependent generation of F1+2, FPA and TAFIa showed a dose-dependent response in normal citrated plasma (NCP), albeit MASP-1 was much less efficient than FXa or thrombin. MASP-1 activation of prothrombin and TAFI cleavage were confirmed in purified systems. No FPA generation was observed in prothrombin-depleted plasma. MASP-1 induced clot formation in NCP, affected clot structure, and prolonged clot lysis. Conclusions/Significance We show that MASP-1 interacts with plasma clot formation on different levels and influences fibrin structure. Although MASP-1-induced fibrin formation is thrombin-dependent, MASP-1 directly activates prothrombin, FXIII and TAFI. We suggest that MASP-1, in concerted action with other complement and coagulation proteins, may play a role in fibrin clot formation.
Resumo:
A hypercoagulable state is a potential mechanism linking elevated blood pressure (BP), adiposity and a sedentary lifestyle to development of coronary heart disease (CHD). We examined relationships among aerobic fitness and adiposity in 76 sedentary subjects with elevated BP. Blood levels of plasminogen activator inhibitor-1 (PAI-1), D-dimer, von Willebrand factor (vWF) and thrombomodulin were assessed as biomarkers of coagulation. In individuals with elevated BP, percent body fat and fitness were associated with biomarkers indicative of a hypercoagulable state, even after demographic and metabolic factors were considered. D-dimer was positively associated with percent body fat (beta=0.37, p=0.003). PAI-1 was higher in men than in women (beta=-0.31, p=0.015) and associated with lower VO2peak (beta=-0.35, p=0.024). Thrombomodulin was positively associated with VO2peak (beta=0.56, p< 0.01). vWF was not significantly associated with fitness or adiposity. Our results emphasise that both percent body fat and physical fitness are important in the maintenance of haemostatic balance.
Resumo:
To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.
Resumo:
The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease.
Resumo:
This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS).
Resumo:
To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.