962 resultados para Disease vector control


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Anopheles darlingi is the most important Brazilian malaria vector, with a widespread distribution in the Amazon forest. Effective strategies for vector control could be better developed through knowledge of its genetic structure and gene flow among populations, to assess the vector diversity and competence in transmitting Plasmodium. The aim of this study was to assess the genetic diversity of An. darlingi collected at four locations in Porto Velho, by sequencing a fragment of the ND4 mitochondrial gene. From 218 individual mosquitoes, we obtained 20 different haplotypes with a diversity index of 0.756, equivalent to that found in other neotropical anophelines. The analysis did not demonstrate significant population structure. However, haplotype diversity within some populations seems to be over-represented, suggesting the presence of sub-populations, but the presence of highly represented haplotypes complicates this analysis. There was no clear correlation among genetic and geographical distance and there were differences in relation to seasonality, which is important for malarial epidemiology.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new approach to dengue vector surveillance based on permanent egg-collection using a modified ovitrap and Bacillus thuringiensis israelensis(Bti) was evaluated in different urban landscapes in Recife, Northeast Brazil. From April 2004 to April 2005, 13 egg-collection cycles of four weeks were carried out. Geo-referenced ovitraps containing grass infusion, Bti and three paddles were placed at fixed sampling stations distributed over five selected sites. Continuous egg-collections yielded more than four million eggs laid into 464 sentinel-ovitraps over one year. The overall positive ovitrap index was 98.5% (over 5,616 trap observations). The egg density index ranged from 100 to 2,500 eggs per trap-cycle, indicating a wide spread and high density of Aedes aegypti (Diptera: Culicidae) breeding populations in all sites. Fluctuations in population density over time were observed, particularly a marked increase from January on, or later, according to site. Massive egg-collection carried out at one of the sites prevented such a population outbreak. At intra-site level, egg counts made it possible to identify spots where the vector population is consistently concentrated over the time, pinpointing areas that should be considered high priority for control activities. The results indicate that these could be promising strategies for detecting and preventing Ae. aegypti population outbreaks.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

French Guiana is one of the areas in South America most affected by malaria and where the disease has become a serious public health problem. In spite of this situation, little recent entomological data are available from the main localities where the disease occurs, even though they are crucial for development of an effective vector control strategy. A longitudinal entomological survey was carried out from March 2000-February 2002 in three Amerindian villages, namely Twenké, Taluène and Cayodé, located in the Amazonian forest of the Upper-Maroni area, to assess anopheline mosquitoes and malaria transmission dynamics. Anopheles darlingi (Diptera: Culicidae) was the most abundant mosquito species caught during the study. This efficient American malaria vector was active the entire year, but showed an evident peak of abundance during the main rainfall season, from April-June, with an average human biting rate of 255.5 bites per person per night. Parity rates were homogeneous all year, indicating no significant seasonal variability in female survival rates. Estimated vectorial capacity indices were higher during the rainy season, even though the risk of transmission was present throughout the year (VCI > 1). A total of 14 An. darlingi were found infected with Plasmodium falciparum, Plasmodium vivax or Plasmodium malariae. The annual circumsporozoite indices were 0.15, 0.14 and 0.05, and the entomological inoculation rates were 22.8, 27.4 and 14.4 infected bites per person per year in Twenké, Taluène and Cayodé, respectively. An. darlingiwas endo-exophagic and rather exophilic in these localities. The species was collected throughout the night but was more aggressive between 21:30-03:30 h and after 05:30 h. Parity rates were homogeneous during the entire night. Impregnated hammock and/or bed nets, coupled with the use of mosquito repellents, as well as the early treatment of malarial cases, appear to be the most suitable tools for fighting malaria in these Amerindian villages since the spraying of residual insecticides is inefficient because of vector biology and the housing structure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This article reports the effects of a pour-on formulation of cypermethrin (6% active ingredient) applied to chickens exposed to Triatoma infestans, the main vector of Chagas disease in rural houses of the Gran Chaco Region of South America. This study was designed as a completely random experiment with three experimental groups and five replicates. Third instar nymphs were fed on chickens treated with 0, 1 and 2 cc of the formulation. Nymphs were allowed to feed on the chickens at different time intervals after the insecticide application. Third-instar nymphs fed on treated chickens showed a higher mortality, took less blood during feeding and had a lower moulting rate. The mortality rate was highest seven days after the insecticide solution application and blood intake was affected until 30 days after the application of the solution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Studies have shown that both carbon dioxide (CO2) and octenol (1-octen-3-ol) are effective attractants for mosquitoes. The objective of the present study was to evaluate the attractiveness of 1-octen-3-ol and CO2 for diurnal mosquitoes in the southeastern Atlantic forest. A Latin square experimental design was employed with four treatments: CDC-light trap (CDC-LT), CDC-LT and 1-octen-3-ol, CDC-LT and CO2 and CDC-LT with 1-octen-3-ol and CO2. Results demonstrated that both CDC-CO2 and CDC-CO2-1-octen-3-ol captured a greater number of mosquito species and specimens compared to CDC-1-octen-3-ol; CDC-LT was used as the control. Interestingly, Anopheles (Kerteszia) sp. was generally attracted to 1-octen-3-ol, whereas Aedes serratus was the most abundant species in all Latin square collections. This species was recently shown to be competent to transmit the yellow fever virus and may therefore play a role as a disease vector in rural areas of Brazil.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The association between land use and land cover changes between 1979-2004 in a 2.26-million-hectare area south of the Gran Chaco region and Trypanosoma cruzi infection in rural communities was analysed. The extent of cultural land, open and closed forests and shrubland up to 3,000 m around rural communities in the north, northwest and west of the province of Córdoba was estimated using Landsat satellite imagery. The T. cruzi prevalence was estimated with a cross-sectional serological survey conducted in the rural communities. The land cover showed the same patterns in the 1979, 1999 and 2004 satellite imagery in both the northwest and west regions, with shrinking regions of cultured land and expanding closed forests away from the community. The closed forests and agricultural land coverage in the north region showed the same trend as in the northwest and west regions in 1979 but not in 1999 or 2004. In the latter two years, the coverage remote from the communities was either constant or changed in opposite ways from that of the northwest and west regions. The changes in closed forests and cultured vegetation alone did not have a significant, direct relationship with the occurrence of rural communities with at least one person infected by T. cruzi. This study suggests that the overall decrease in the prevalence of T. cruzi is a consequence of a combined effect of vector control activities and changes in land use and land cover.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The use of chemical insecticides continues to play a major role in the control of disease vector populations, which is leading to the global dissemination of insecticide resistance. A greater capacity to detoxify insecticides, due to an increase in the expression or activity of three major enzyme families, also known as metabolic resistance, is one major resistance mechanisms. The esterase family of enzymes hydrolyse ester bonds, which are present in a wide range of insecticides; therefore, these enzymes may be involved in resistance to the main chemicals employed in control programs. Historically, insecticide resistance has driven research on insect esterases and schemes for their classification. Currently, several different nomenclatures are used to describe the esterases of distinct species and a universal standard classification does not exist. The esterase gene family appears to be rapidly evolving and each insect species has a unique complement of detoxification genes with only a few orthologues across species. The examples listed in this review cover different aspects of their biochemical nature. However, they do not appear to contribute to reliably distinguish among the different resistance mechanisms. Presently, the phylogenetic criterion appears to be the best one for esterase classification. Joint genomic, biochemical and microarray studies will help unravel the classification of this complex gene family.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Because of the development of modern transportation facilities, an ever rising number of individuals including many patients with preexisting diseases visit high-altitude locations (>2500 m). High-altitude exposure triggers a series of physiologic responses intended to maintain an adequate tissue oxygenation. Even in normal subjects, there is enormous interindividual variability in these responses that may be further amplified by environmental factors such as cold temperature, low humidity, exercise, and stress. These adaptive mechanisms, although generally tolerated by most healthy subjects, may induce major problems in patients with preexisting cardiovascular diseases in which the functional reserves are already limited. Preexposure assessment of patients helps to minimize risk and detect contraindications to high-altitude exposure. Moreover, the great variability and nonpredictability of the adaptive response should encourage physicians counseling such patients to adapt a cautionary approach. Here, we will briefly review how high-altitude adjustments may interfere with and aggravate/decompensate preexisting cardiovascular diseases. Moreover, we will provide practical recommendations on how to investigate and counsel patients with cardiovascular disease desiring to travel to high-altitude locations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thedirect torque control (DTC) has become an accepted vector control method besidethe current vector control. The DTC was first applied to asynchronous machines,and has later been applied also to synchronous machines. This thesis analyses the application of the DTC to permanent magnet synchronous machines (PMSM). In order to take the full advantage of the DTC, the PMSM has to be properly dimensioned. Therefore the effect of the motor parameters is analysed taking the control principle into account. Based on the analysis, a parameter selection procedure is presented. The analysis and the selection procedure utilize nonlinear optimization methods. The key element of a direct torque controlled drive is the estimation of the stator flux linkage. Different estimation methods - a combination of current and voltage models and improved integration methods - are analysed. The effect of an incorrect measured rotor angle in the current model is analysed andan error detection and compensation method is presented. The dynamic performance of an earlier presented sensorless flux estimation method is made better by improving the dynamic performance of the low-pass filter used and by adapting the correction of the flux linkage to torque changes. A method for the estimation ofthe initial angle of the rotor is presented. The method is based on measuring the inductance of the machine in several directions and fitting the measurements into a model. The model is nonlinear with respect to the rotor angle and therefore a nonlinear least squares optimization method is needed in the procedure. A commonly used current vector control scheme is the minimum current control. In the DTC the stator flux linkage reference is usually kept constant. Achieving the minimum current requires the control of the reference. An on-line method to perform the minimization of the current by controlling the stator flux linkage reference is presented. Also, the control of the reference above the base speed is considered. A new estimation flux linkage is introduced for the estimation of the parameters of the machine model. In order to utilize the flux linkage estimates in off-line parameter estimation, the integration methods are improved. An adaptive correction is used in the same way as in the estimation of the controller stator flux linkage. The presented parameter estimation methods are then used in aself-commissioning scheme. The proposed methods are tested with a laboratory drive, which consists of a commercial inverter hardware with a modified software and several prototype PMSMs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Direct torque control (DTC) is a new control method for rotating field electrical machines. DTC controls directly the motor stator flux linkage with the stator voltage, and no stator current controllers are used. With the DTC method very good torque dynamics can be achieved. Until now, DTC has been applied to asynchronous motor drives. The purpose of this work is to analyse the applicability of DTC to electrically excited synchronous motor drives. Compared with asynchronous motor drives, electrically excited synchronous motor drives require an additional control for the rotor field current. The field current control is called excitation control in this study. The dependence of the static and dynamic performance of DTC synchronous motor drives on the excitation control has been analysed and a straightforward excitation control method has been developed and tested. In the field weakening range the stator flux linkage modulus must be reduced in order to keep the electro motive force of the synchronous motor smaller than the stator voltage and in order to maintain a sufficient voltage reserve. The dynamic performance of the DTC synchronous motor drive depends on the stator flux linkage modulus. Another important factor for the dynamic performance in the field weakening range is the excitation control. The field weakening analysis considers both dependencies. A modified excitation control method, which maximises the dynamic performance in the field weakening range, has been developed. In synchronous motor drives the load angle must be kept in a stabile working area in order to avoid loss of synchronism. The traditional vector control methods allow to adjust the load angle of the synchronous motor directly by the stator current control. In the DTC synchronous motor drive the load angle is not a directly controllable variable, but it is formed freely according to the motor’s electromagnetic state and load. The load angle can be limited indirectly by limiting the torque reference. This method is however parameter sensitive and requires a safety margin between the theoretical torque maximum and the actual torque limit. The DTC modulation principle allows however a direct load angle adjustment without any current control. In this work a direct load angle control method has been developed. The method keeps the drive stabile and allows the maximal utilisation of the drive without a safety margin in the torque limitation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This master’s thesis mainly focuses on the design requirements of an Electric drive for Hybrid car application and its control strategy to achieve a wide speed range. It also emphasises how the control and performance requirements are transformed into its design variables. A parallel hybrid topology is considered where an IC engine and an electric drive share a common crank shaft. A permanent magnet synchronous machine (PMSM) is used as an electric drive machine. Performance requirements are converted into Machine design variables using the vector model of PMSM. Main dimensions of the machine are arrived using analytical approach and Finite Element Analysis (FEA) is used to verify the design and performance. Vector control algorithm was used to control the machine. The control algorithm was tested in a low power PMSM using an embedded controller. A prototype of 10 kW PMSM was built according to the design values. The prototype was tested in the laboratory using a high power converter. Tests were carried out to verify different operating modes. The results were in agreement with the calculations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCCION. En Colombia y a nivel mundial la vacunación es una estrategia que ha reducido la mortalidad infantil, sin embargo existen bajas coberturas en algunas zonas del país, dentro de las causas de la no vacunación se encuentra el bajo peso al nacer, tema de gran importancia y poco estudiado, encontrándose como una causa controlable y que permitiría a la población acceder a la protección frente a enfermedades inmunoprevenibles. MATERIALES Y METODOS. Se realizó un estudio de tipo observacional de corte trasversal, la muestra fue tomada de la ENDS realizada por Profamilia en el año 2010, se tomó el número total de los encuestados que cumplían con los criterios de inclusión, en total fueron 9694 registros a los que se les realizo; análisis descriptivo, bivariado y multivariado. RESULTADOS. Los niños con bajo peso al nacer tienen menor probabilidad de estar vacunados con el esquema completo con respecto a los niños con peso normal, OR 0762 (IC 95% 0,650; 0,895), se observó que las vacunas en forma individual tienen un comportamiento similar al esquema completo, específicamente en la aplicación en el tiempo indicado para su aplicación, exceptuando triple viral donde no se encontró asociación. CONCLUSION. El bajo peso es un factor determinante en la vacunación a tiempo de los menores y del cumplimiento posterior del esquema, se encontraron variables asociadas al no cumplimiento como el lugar del parto, el índice de pobreza y pertenecer a la etnia afrodescendiente.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A dynamic, deterministic, economic simulation model was developed to estimate the costs and benefits of controlling Mycobacterium avium subsp. paratuberculosis (Johne's disease) in a suckler beef herd. The model is intended as a demonstration tool for veterinarians to use with farmers. The model design process involved user consultation and participation and the model is freely accessible on a dedicated website. The 'user-friendly' model interface allows the input of key assumptions and farm specific parameters enabling model simulations to be tailored to individual farm circumstances. The model simulates the effect of Johne's disease and various measures for its control in terms of herd prevalence and the shedding states of animals within the herd, the financial costs of the disease and of any control measures and the likely benefits of control of Johne's disease for the beef suckler herd over a 10-year period. The model thus helps to make more transparent the 'hidden costs' of Johne's in a herd and the likely benefits to be gained from controlling the disease. The control strategies considered within the model are 'no control', 'testing and culling of diagnosed animals', 'improving management measures' or a dual strategy of 'testing and culling in association with improving management measures'. An example 'run' of the model shows that the strategy 'improving management measures', which reduces infection routes during the early stages, results in a marked fall in herd prevalence and total costs. Testing and culling does little to reduce prevalence and does not reduce total costs over the 10-year period.