929 resultados para Diode-laser


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: This study aimed to investigate the effect of 830 and 670 nm diode laser on the viability of random skin flaps in rats. Background data: Low-level laser therapy (LLLT) has been reported to be successful in stimulating the formation of new blood vessels and reducing the inflammatory process after injury. However, the efficiency of such treatment remains uncertain, and there is also some controversy regarding the efficacy of different wavelengths currently on the market. Materials and methods: Thirty Wistar rats were used and divided into three groups, with 10 rats in each. A random skin flap was raised on the dorsum of each animal. Group 1 was the control group, group 2 received 830 nm laser radiations, and group 3 was submitted to 670 nm laser radiation (power density = 0.5 mW/cm(2)). The animals underwent laser therapy with 36 J/cm(2) energy density (total energy = 2.52 J and 72 sec per session) immediately after surgery and on the 4 subsequent days. The application site of laser radiation was one point at 2.5 cm from the flap's cranial base. The percentage of skin flap necrosis area was calculated on the 7th postoperative day using the paper template method. A skin sample was collected immediately after to determine the vascular endothelial growth factor (VEGF) expression and the epidermal cell proliferation index (KiD67). Results: Statistically significant differences were found among the percentages of necrosis, with higher values observed in group 1 compared with groups 2 and 3. No statistically significant differences were found among these groups using the paper template method. Group 3 presented the highest mean number of blood vessels expressing VEGF and of cells in the proliferative phase when compared with groups 1 and 2. Conclusions: LLLT was effective in increasing random skin flap viability in rats. The 670 nm laser presented more satisfactory results than the 830 nm laser.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: to evaluate the effects of low-level laser therapy for perineal pain and healing after episiotomy. Design: a double-blind, randomised, controlled clinical trial comparing perineal pain scores and episiotomy healing in women treated with low-level laser therapy (LLLT) and with the simulation of the treatment. Setting: the study was conducted in the Birth Centre and rooming-in units of Amparo Maternal, a maternity service located in the city of Sao Paulo, Brazil. Participants: fifty-two postpartum women who had had mediolateral episiotomies during their first normal delivery were randomly divided into two groups of 26: an experimental group and a control group. Intervention: in the experimental group, the women were treated with LLLT. Irradiation was applied at three points directly on the episiotomy after the suture and in three postpartum sessions: up to 2 hrs postpartum, between 20 and 24 hrs postpartum and between 40 and 48 hrs postpartum. The LLLT was performed with diode laser, with a wavelength of 660 nm (red light), spot size of 0.04 cm(2), energy density of 3.8 J/cm(2), radiant power of 15 mW and 10 s per point, which resulted in an energy of 0.15 J per point and a total energy of 0.45 J per session. The control group participants also underwent three treatment sessions, but without the emission of radiation (simulation group), to assess the possible effects of placebo treatment. Main outcomes: perineal pain scores, rated on a scale from 0 to 10, were evaluated before and immediately after the irradiation in the three sessions. The healing process was assessed using the REEDA scale (Redness, Edema, Echymosis, Discharge Aproximation) before each laser therapy session and 15 and 20 days after the women's discharge. Findings: comparing the pain scores before and after the LLLT sessions, the experimental group presented a significant within-group reduction in mean pain scores after the second and third sessions (p=0.003 and p<0.001, respectively), and the control group showed a significant reduction after the first treatment simulation (p=0.043). However, the comparison of the perineal pain scores between the experimental and control groups indicated no statistical difference at any of the evaluated time points. There was no significant difference in perineal healing scores between the groups. All postpartum women approved of the low-level laser therapy. Conclusions: this pilot study showed that LLLT did not accelerate episiotomy healing. Although there was a reduction in perineal pain mean scores in the experimental group, we cannot conclude that the laser relieved perineal pain. This study led to the suggestion of a new research proposal involving another irradiation protocol to evaluate LLLT's effect on perineal pain relief. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Low-level laser irradiation (LLLI) and recombinant human bone morphogenetic protein type 2 (rhBMP-2) have been used to stimulate bone formation. LLLI stimulates proliferation of osteoblast precursor cells and cell differentiation and rhBMP-2 recruits osteoprogenitor cells to the bone healing area. This in vivo study evaluated the effects of LLLI and rhBMP-2 on the bone healing process in rats. Critical bone defects were created in the parietal bone in 42 animals, and the animals were divided into six treatment groups: (1) laser, (2) 7 mu g of rhBMP-2, (3) laser and 7 mu g of rhBMP-2, (4) 7 mu g of rhBMP-2/monoolein gel, (5) laser and 7 mu g rhBMP-2/monoolein gel, and (6) critical bone defect controls. A gallium-aluminum-arsenide diode laser was used (wavelength 780 nm, output power 60 mW, beam area 0.04 cm(2), irradiation time 80 s, energy density 120 J/cm(2), irradiance 1.5 W/cm(2)). After 15 days, the calvarial tissues were removed for histomorphometric analysis. Group 3 defects showed higher amounts of newly formed bone (37.89%) than the defects of all the other groups (P < 0.05). The amounts of new bone in defects of groups 1 and 4 were not significantly different from each other (24.00% and 24.75%, respectively), but were significantly different from the amounts in the other groups (P < 0.05). The amounts of new bone in the defects of groups 2 and 5 were not significantly different from each other (31.42% and 31.96%, respectively), but were significantly different from the amounts in the other groups (P < 0.05). Group 6 defects had 14.10% new bone formation, and this was significantly different from the amounts in the other groups (P < 0.05). It can be concluded that LLLI administered during surgery effectively accelerated healing of critical bone defects filled with pure rhBMP-2, achieving a better result than LLLI alone or the use of rhBMP-2 alone.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this study was to compare retrospectively the effect of three different treatments on the healing outcome of bisphosphonate-related osteonecrosis of the jaws (BRONJ) in cancer patients. Twenty-two cancer patients were treated for BRONJ with one of the following protocols: clinical (pharmacological therapy), surgical (pharmacological plus surgical therapy), or PRP plus LPT (pharmacological plus surgical plus platelet rich plasma (PRP) plus laser phototherapy (LPT). The laser treatment was applied with a continuous diode laser (InGaAlP, 660 nm) using punctual and contact mode, 40 mW, spot size 0.042 cm(2), 6 J/cm(2) (6 s) and total energy of 0.24 J per point. The irradiations were performed on the exposed bone and surrounding soft tissue. The analysis of demographic data and risk factors was performed by gathering the following information: age, gender, primary tumor, bisphosphonate (BP) used, duration of BP intake, history of chemotherapy, use of steroids, and medical history of diabetes. The association between the current state of BRONJ (with or without bone exposure) and other qualitative variables was determined using the chi-square or Fisher's exact test. In all tests, the significance level adopted was 5%. Most BRONJ lesions occurred in the mandible (77%) after tooth extraction (55%) and in women (72%). A significantly higher percentage of patients reached the current state of BRONJ without bone exposure (86%) in the PPR plus LPT group than in the pharmacological (0%) and surgical (40%) groups after 1-month follow-up assessment. These results suggest that the association of pharmacological therapy and surgical therapy with PRP plus LPT significantly improves BRONJ healing in oncologic patients. Although prospective studies with larger sample sizes are still needed, this preliminary study may be used to inform a better-designed future study. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aims and objectives. To evaluate the effectiveness of a low-level laser therapy for pain relief in the perineum following episiotomy during childbirth. Background. Laser irradiation is a painless and non-invasive therapy for perineal pain treatment and its effects have been investigated in several studies, with no clear conclusion on its effectiveness. Design. A double-blind randomised controlled clinical trial. Method. One hundred and fourteen women who underwent right mediolateral episiotomies during vaginal birth in an in-hospital birthing centre in Sao Paulo, Brazil and reported pain =3 on a numeric scale (010) were randomised into three groups of 38 women each: two experimental groups (treated with red and infrared laser) and a control group. The experimental groups were treated with laser applied at three points directly on the episiotomy after suturing in a single session between 656 hours postpartum. We used a diode laser with wavelengths of 660 nm (red laser) and 780 nm (infrared laser). The control group participants underwent all laser procedures, excluding the emission of irradiation. The participants and the pain scores evaluator were blinded to the type of intervention. The perineal pain scores were assessed at three time points: before, immediately after and 30 minutes after low-level laser therapy. Results. The comparison of perineal pain between the three groups showed no significant differences in the three evaluations (p = 0.445), indicating that the results obtained in the groups treated with low-level laser therapy were equivalent to the control group. Conclusions. Low-level laser therapy did not decrease the intensity of perineal pain reported by women who underwent right mediolateral episiotomy. Relevance to clinical practice. The effect of laser in perineal pain relief was not demonstrated in this study. The dosage may not have been sufficient to provide relief from perineal pain after episiotomy during a vaginal birth.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: Laser hair removal is becoming an increasingly popular alternative to traditional methods such as shaving, waxing, among other methods. Semiconductor diode lasers are considered the most efficient light sources available and are especially well suited for clinical applications including hair reduction. The effectiveness of laser hair reduction depends on many variables, including the skin type of the patient. Material and Methods: A patient with Fitzpatrick Skin Type IV was submitted to laser hair removal of the arms with a high-power diode laser system with long pulses with a wavelength of 800 nm, a fluence of 40 J/cm2 and a pulse width of 20 ms. A 12-month follow-up assessment was performed and included photography and questionnaire. Results: Hypopigmentation was observed after a single laser hair removal section. After 6 months with the area totally covered, a gradual suntan with a sun screen lotion with an SPF of 15 was prescribed by the dermatologist. After 12 months of the initial treatment, a complete recovery of the hypopigmentation was achieved. Conclusion: Although a safe procedure, lasers for hair removal may be associated with adverse side effects including undesired pigment alterations. Before starting a laser hair removal treatment, patients seeking the eradication of hair should be informed that temporary, and possibly permanent, pigmentary changes may occur.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives: The objective of this study was to apply low-level laser therapy (LLLT) to accelerate the recovery process of a child patient with Bell's palsy (BP). Design: This was a prospective study. Subject: The subject was a three-year-old boy with a sudden onset of facial asymmetry due to an unknown cause. Materials and methods: The low-level laser source used was a gallium aluminum arsenide semiconductor diode laser device (660nm and 780 nm). No steroids or other medications were given to the child. The laser beam with a 0.04-cm2 spot area, and an aperture with approximately 1-mm diameter, was applied in a continuous emission mode in direct contact with the facial area. The duration of a laser session was between 15 and 30 minutes, depending on the chosen points and the area being treated. Light was applied 10 seconds per point on a maximum number of 80 points, when the entire affected (right) side of the face was irradiated, based on the small laser beam spot size. According to the acupuncture literature, this treatment could also be carried out using 10-20 Chinese acupuncture points, located unilaterally on the face. In this case study, more points were used because the entire affected side of the face (a large area) was irradiated instead of using acupuncture points. Outcome measures: The House-Brackmann grading system was used to monitor the evolution of facial nerve motor function. Photographs were taken after every session, always using the same camera and the same magnitude. The three-year-old boy recovered completely from BP after 11 sessions of LLLT. There were 4 sessions a week for the first 2 weeks, and the total treatment time was 3 weeks. Results: The result of this study was the improvement of facial movement and facial symmetry, with complete reestablishment to normality. Conclusions: LLLT may be an alternative to speed up facial normality in pediatric BP.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The subject of the presented thesis is the accurate measurement of time dilation, aiming at a quantitative test of special relativity. By means of laser spectroscopy, the relativistic Doppler shifts of a clock transition in the metastable triplet spectrum of ^7Li^+ are simultaneously measured with and against the direction of motion of the ions. By employing saturation or optical double resonance spectroscopy, the Doppler broadening as caused by the ions' velocity distribution is eliminated. From these shifts both time dilation as well as the ion velocity can be extracted with high accuracy allowing for a test of the predictions of special relativity. A diode laser and a frequency-doubled titanium sapphire laser were set up for antiparallel and parallel excitation of the ions, respectively. To achieve a robust control of the laser frequencies required for the beam times, a redundant system of frequency standards consisting of a rubidium spectrometer, an iodine spectrometer, and a frequency comb was developed. At the experimental section of the ESR, an automated laser beam guiding system for exact control of polarisation, beam profile, and overlap with the ion beam, as well as a fluorescence detection system were built up. During the first experiments, the production, acceleration and lifetime of the metastable ions at the GSI heavy ion facility were investigated for the first time. The characterisation of the ion beam allowed for the first time to measure its velocity directly via the Doppler effect, which resulted in a new improved calibration of the electron cooler. In the following step the first sub-Doppler spectroscopy signals from an ion beam at 33.8 %c could be recorded. The unprecedented accuracy in such experiments allowed to derive a new upper bound for possible higher-order deviations from special relativity. Moreover future measurements with the experimental setup developed in this thesis have the potential to improve the sensitivity to low-order deviations by at least one order of magnitude compared to previous experiments; and will thus lead to a further contribution to the test of the standard model.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Die kollineare Laserspektroskopie hat sich in den vergangenen drei Jahrzehnten zur Bestimmung der Kernladungsradien mittelschwerer und schwerer kurzlebiger Atomkerne in ausgezeichneter Weise bewährt. Auf die Isotope sehr leichter Elemente konnte sie allerdings erst kürzlich erweitert werden. Dieser Bereich der Nuklidkarte ist von besonderem Interesse, denn die ersten ab-initio Modelle der Kernphysik, die den Aufbau eines Atomkerns basierend auf individuellen Nukleonen und realistischenWechselwirkungspotentialen beschreiben, sind gegenwärtig nur für die leichtesten Elemente anwendbar. Außerdem existiertrnin dieser Region eine besonders exotische Form von Atomkernen, die sogenanntenrnHalokerne. Die Isotopenkette der Berylliumisotope zeichnet sich durch das Auftreten des Ein-Neutronen Halokerns 11Be und des Zwei- oder Vier-Neutronen-Halos 14Be aus. Dem Isotop 12Be kommt durch seine Position zwischen diesen beiden Exoten und den im Schalenmodell erwarteten magischen Schalenabschluss N = 8 eine besondere Bedeutung zu.rnIm Rahmen dieser Arbeit wurden mehrere frequenzstabilisierte Lasersysteme für die kollineare Laserspektroskopie aufgebaut. An TRIGA-SPEC stehen nun unter anderem ein frequenzverdoppeltes Diodenlasersystem mit Trapezverstärker und frequenzkammstabilisierter Titan-Saphirlaser mit Frequenzverdopplungsstufe für die Spektroskopie an refraktären Elementen oberhalb von Molybdän zur Verfügung, die für erste Testexperimente eingesetzt wurden. Außerdem wurde die effiziente Frequenzvervierfachung eines Titan-Saphirlasers demonstriert. An ISOLDE/CERN wurde ein frequenzkammstabilisierter und ein jodstabilisierter Farbstofflaser installiert und für die Laserspektroskopie an 9,10,11,12Be eingesetzt. Durch das verbesserte Lasersystem und den Einsatz eines verzögerten Koinzidenznachweises für Photonen und Ionen gelang es die Empfindlichkeitrnder Berylliumspektroskopie um mehr als zwei Größenordnungen zu steigern und damit die früheren Messungen an 7−11Be erstmals auf das Isotop 12Be auszuweiten. Außerdem wurde die Genauigkeit der absoluten Übergangsfrequenzen und der Isotopieverschiebungen der Isotope 9,10,11Be signifikant verbessert.rnDurch den Vergleich mit Ergebnissen des Fermionic Molecular Dynamics Modells kann der Trend der Ladungsradien der leichteren Isotope durch die ausgeprägte Clusterstruktur der Berylliumkerne erklärt werden. Für 12Be wird ersichtlich, dass der Grundzustand durch eine (sd)2 Konfiguration statt der vom Schalenmodell erwarteten p2 Konfiguration dominiert wird. Dies ist ein klares Indiz für das bereits zuvor beobachtete Verschwinden des N = 8 Schalenabschlusses bei 12Be.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Gynecomastia is the most common breast pathology. Numerous excisions and liposuction techniques have been described to correct bilateral male breast enlargement. Recently, there has been a shift from the open approach to minimally invasive techniques. This article reports a 5-year experience using laser-assisted lipolysis (LAL) to treat gynecomastia, and describes the surgical technique. Between January 2006 and December 2010, a total of 28 patients with bilateral gynecomastia were treated with LAL. Patients had a mean age of 36.5 years (range 24 to 56 years). LAL was performed with a 980-nm diode laser (continuous emission, 15 W power, 8-12 kJ total energy per breast) after tumescent anesthetic infiltration. The breast was evaluated objectively by two physicians who compared chest circumference and photographs. Patients were also asked to score the results using a visual analogue scale: 75 to 100 (very good), 50-74 (good), 25 to 49 (fair) and 0 to 24 (poor). The postoperative period for all patients was incident-free. After 6 months, 18 patients (64.3%) scored the results as "very good", 6 as "good" (21.4%), 3 as "fair" (10.7%) and 1 "poor" (3.6%). Mean chest circumferences pre- and postoperatively were, respectively, 117.4 ± 11.1 cm and 103.3 ± 7.5 cm (p < 0.001), corresponding to a mean difference of 14.1 cm. Physicians scored the photographs as "very good" in 22 patients (78.6%), as "good" in five patients (17.9%), and as "fair" in one patient (3.6%). LAL in gynecomastia is safe and produces significant effects on fatty tissue, with a reduction in breast volume, together with significant skin tightening. Provided an appropriate amount of energy is delivered by an experienced operator, the results are both significant and consistent.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: In this in vitro feasibility study we analyzed tissue fusion using bovine serum albumin (BSA) and Indocyanine green (ICG) doped polycaprolactone (PCL) scaffolds in combination with a diode laser as energy source while focusing on the influence of irradiation power and albumin concentration on the resulting tensile strength and induced tissue damage. MATERIALS AND METHODS: A porous PCL scaffold doped with either 25% or 40% (w/w) of BSA in combination with 0.1% (w/w) ICG was used to fuse rabbit aortas. Soldering energy was delivered through the vessel from the endoluminal side using a continuous wave diode laser at 808 nm via a 400 microm core fiber. Scaffold surface temperatures were analyzed with an infrared camera. Optimum parameters such as irradiation time, radiation power and temperature were determined in view of maximum tensile strength but simultaneously minimum thermally induced tissue damage. Differential scanning calorimetry (DSC) was performed to measure the influence of PCL on the denaturation temperature of BSA. RESULTS: Optimum parameter settings were found to be 60 seconds irradiation time and 1.5 W irradiation power resulting in tensile strengths of around 2,000 mN. Corresponding scaffold surface temperature was 117.4+/- 12 degrees C. Comparison of the two BSA concentration revealed that 40% BSA scaffold resulted in significant higher tensile strength compared to the 25%. At optimum parameter settings, thermal damage was restricted to the adventitia and its interface with the outermost layer of the tunica media. The DSC showed two endothermic peaks in BSA containing samples, both strongly depending on the water content and the presence of PCL and/or ICG. CONCLUSIONS: Diode laser soldering of vascular tissue using BSA-ICG-PCL-scaffolds leads to strong and reproducible tissue bonds, with vessel damage limited to the adventitia. Higher BSA content results in higher tensile strengths. The DSC-measurements showed that BSA denaturation temperature is lowered by addition of water and/or ICG-PCL.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The space-qualified design of a miniaturized laser for pulsed operation at a wavelength of 1064 nm and at repetition rates up to 10 Hz is presented. This laser consists of a pair of diode-laser pumped, actively q-switched Nd:YAG rod oscillators hermetically sealed and encapsulated in an environment of dry synthetic air. The system delivers at least 300 million laser pulses with 50 mJ energy and 5 ns pulse width (FWHM). It will be launched in 2017 aboard European Space Agency’s Mercury Planetary Orbiter as part of the BepiColombo Laser Altimeter, which, after a 6-years cruise, will start recording topographic data from orbital altitudes between 400 and 1500 km above Mercury’s surface.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A high-power high-efficiency laser power transmission system at 100m based on an optimized multi-cell GaAs converter capable of supplying 9.7W of electricity is demonstrated. An I-V testing system integrated with a data acquisition circuit and an analysis software is designed to measure the efficiency and the I-V characteristics of the laser power converter (LPC). The dependencies of the converter’s efficiency with respect to wavelength, laser intensity and temperature are analyzed. A diode laser with 793nm of wavelength and 24W of power is used to test the LPC and the software. The maximum efficiency of the LPC is 48.4% at an input laser power of 8W at room temperature. When the input laser power is 24W (laser intensity of 60000W/m2), the efficiency is 40.4% and the output voltage is 4 V. The overall efficiency from electricity to electricity is 11.6%.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Este estudo investigou os efeitos do laser de baixa intensidade na velocidade da movimentação ortodôntica de caninos submetidos à retração inicial. A amostra constou de 26 caninos superiores e inferiores, submetidos à retração inicial realizada com mola Niti, com força de 150g. Um dos caninos foi irradiado com laser de diodo, seguindo o protocolo de aplicação: 780nm/20mW/5Jcm2/0,2J por ponto/Et=2J, nos dias 0, 3 e 7 pós-ativação, sendo que o contralateral foi considerado placebo. A retração durou em média 4 meses, num total de 9 aplicações de laser. Os modelos de cada mês foram escaneados com scanner 3D (3Shape) e as imagens tridimensionais foram analisadas por meio do Software Geomagic Studio 5, para a mensuração da quantidade de movimentação dos caninos retraídos. Foi empregada a Análise de Variância a três critérios, seguida pelo teste de Tukey (p<0,05). Para verificação da integridade tecidual, foram efetuadas radiografias periapicais iniciais e finais dos caninos retraídos e dos molares, nas quais foram avaliados uma possível reabsorção na crista alveolar, por meio da distância da crista óssea alveolar até a junção cemento-esmalte e os níveis de reabsorção radicular, por meio do índice de Levander e Malmgreen, sendo este último avaliado somente nos caninos retraídos. Para isto, foi empregado o teste não paramétrico de Wilcoxon (p<0,05). Os resultados indicaram que houve um aumento estatisticamente significante na velocidade da movimentação dos caninos irradiados comparados ao seu contralateral, em todos os tempos avaliados, como também a preservação da integridade tecidual. Com isso, concluiu-se que o laser de diodo pode acelerar a movimentação ortodôntica, podendo contribuir para a diminuição do tempo de tratamento.(AU)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Este estudo investigou os efeitos do laser de baixa intensidade na velocidade da movimentação ortodôntica de caninos submetidos à retração inicial. A amostra constou de 26 caninos superiores e inferiores, submetidos à retração inicial realizada com mola Niti, com força de 150g. Um dos caninos foi irradiado com laser de diodo, seguindo o protocolo de aplicação: 780nm/20mW/5Jcm2/0,2J por ponto/Et=2J, nos dias 0, 3 e 7 pós-ativação, sendo que o contralateral foi considerado placebo. A retração durou em média 4 meses, num total de 9 aplicações de laser. Os modelos de cada mês foram escaneados com scanner 3D (3Shape) e as imagens tridimensionais foram analisadas por meio do Software Geomagic Studio 5, para a mensuração da quantidade de movimentação dos caninos retraídos. Foi empregada a Análise de Variância a três critérios, seguida pelo teste de Tukey (p<0,05). Para verificação da integridade tecidual, foram efetuadas radiografias periapicais iniciais e finais dos caninos retraídos e dos molares, nas quais foram avaliados uma possível reabsorção na crista alveolar, por meio da distância da crista óssea alveolar até a junção cemento-esmalte e os níveis de reabsorção radicular, por meio do índice de Levander e Malmgreen, sendo este último avaliado somente nos caninos retraídos. Para isto, foi empregado o teste não paramétrico de Wilcoxon (p<0,05). Os resultados indicaram que houve um aumento estatisticamente significante na velocidade da movimentação dos caninos irradiados comparados ao seu contralateral, em todos os tempos avaliados, como também a preservação da integridade tecidual. Com isso, concluiu-se que o laser de diodo pode acelerar a movimentação ortodôntica, podendo contribuir para a diminuição do tempo de tratamento.(AU)