978 resultados para Digital systems
Resumo:
This paper presents the results of my action research. I was involved in establishing and running a digital library that was founded by the government of South Korea. The process involved understanding the relationship between the national IT infrastructure and the success factors of the digital library. In building, the national IT infrastructure, a digital library system was implemented; it combines all existing digitized university libraries and can provide overseas information, such as foreign journal articles, instantly and freely to every Korean researcher. An empirical survey was made as a part of the action research; the survey determined user satisfaction in the newly established national digital library. After obtaining the survey results, I suggested that the current way of running the nationwide government-owned digital library should be retained. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
This paper proposes a wireless EEG acquisition platform based on Open Multimedia Architecture Platform (OMAP) embedded system. A high-impedance active dry electrode was tested for improving the scalp- electrode interface. It was used the sigma-delta ADS1298 analog-to-digital converter, and developed a “kernelspace” character driver to manage the communications between the converter unit and the OMAP’s ARM core. The acquired EEG signal data is processed by a “userspace” application, which accesses the driver’s memory, saves the data to a SD-card and transmits them through a wireless TCP/IP-socket to a PC. The electrodes were tested through the alpha wave replacement phenomenon. The experimental results presented the expected alpha rhythm (8-13 Hz) reactiveness to the eyes opening task. The driver spends about 725 μs to acquire and store the data samples. The application takes about 244 μs to get the data from the driver and 1.4 ms to save it in the SD-card. A WiFi throughput of 12.8Mbps was measured which results in a transmission time of 5 ms for 512 kb of data. The embedded system consumes about 200 mAh when wireless off and 400 mAh when it is on. The system exhibits a reliable performance to record EEG signals and transmit them wirelessly. Besides the microcontroller-based architectures, the proposed platform demonstrates that powerful ARM processors running embedded operating systems can be programmed with real-time constrains at the kernel level in order to control hardware, while maintaining their parallel processing abilities in high level software applications.
Resumo:
In a Europe increasingly aging, it is now recognized the importance and potential of the service industry for ageing well based on information and communication technologies (ICT), as exemplified by the electronic market of social services and health care, the GuiMarket, proposed by the authors. However, this new range of services requires that individuals have advanced digital skills to fully participate in society. Based on the results of a survey made on a sample of 315 individuals, this paper discusses the importance granted GuiMarket and the intended frequency of use, concluding there is a close relationship between ICT access and use that respondents anticipate making of GuiMarket and alike services.
Resumo:
During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided.
Resumo:
Digital X-ray detector technologies provide several advantages when compared with screen-film (SF) systems: better diagnostic quality of the radiographic image, increased dose efficiency, better dynamic range and possible reduction of radiation exposure to the patient. The transition from traditional SF systems to digital technology-based systems highlights the importance of the discussion around technical factors such as image acquisition, themanagement of patient dose and diagnostic image quality. Radiographers should be aware of these aspects concerning their clinical practice regarding the advantages and limitations of digital detectors. Newdigital technologies require an up-to-date of scientific knowledge concerning their use in projection radiography. This is the second of a two-part review article focused on a technical overview of digital radiography detectors. This article provides a discussion about the issues related to the image acquisition requirements and advantages of digital technologies, the management of patient dose and the diagnostic image quality.
Resumo:
Introdução – A mamografia é o principal método de diagnóstico por imagem utilizado no rastreio e diagnóstico do cancro da mama, sendo a modalidade de imagem recomendada em vários países da Europa e Estados Unidos para utilização em programas de rastreio. A implementação da tecnologia digital causou alterações na prática da mamografia, nomeadamente a necessidade de adaptar os programas de controlo de qualidade. Objetivos – Caracterizar a tecnologia instalada para mamografia em Portugal e as práticas adotadas na sua utilização pelos profissionais de saúde envolvidos. Concluir sobre o nível de harmonização das práticas em mamografia em Portugal e a conformidade com as recomendações internacionais. Identificar oportunidades para otimização que permitam assegurar a utilização eficaz e segura da tecnologia. Metodologia – Pesquisa e recolha de dados sobre a tecnologia instalada, fornecidos por fontes governamentais, prestadores de serviços de mamografia e indústria. Construção de três questionários, orientados ao perfil do médico radiologista, técnico de radiologia com atividade em mamografia digital e técnico de radiologia coordenador. Os questionários foram aplicados em 65 prestadores de serviços de mamografia selecionados com base em critérios de localização geográfica, tipo de tecnologia instalada e perfil da instituição. Resultados – Foram identificados 441 sistemas para mamografia em Portugal. A tecnologia mais frequente (62%) e vulgarmente conhecida por radiografia computorizada (computed radiography) é constituída por um detector (image plate) de material fotoestimulável inserido numa cassete de suporte e por um sistema de processamento ótico. A maioria destes sistemas (78%) está instalada em prestadores privados. Aproximadamente 12% dos equipamentos instalados são sistemas para radiografia digital direta (Direct Digital Radiography – DDR). Os critérios para seleção dos parâmetros técnicos de exposição variam, observando-se que em 65% das instituições são adotadas as recomendações dos fabricantes do equipamento. As ferramentas de pós-processamento mais usadas pelos médicos radiologistas são o ajuste do contraste e brilho e magnificação total e/ou localizada da imagem. Quinze instituições (em 19) têm implementado um programa de controlo de qualidade. Conclusões – Portugal apresenta um parque de equipamentos heterogéneo que inclui tecnologia obsoleta e tecnologia “topo de gama”. As recomendações/guidelines (europeias ou americanas) não são adotadas formalmente na maioria das instituições como guia para fundamentação das práticas em mamografia, dominando as recomendações dos fabricantes do equipamento. Foram identificadas, pelos técnicos de radiologia e médicos radiologistas, carências de formação especializada, nomeadamente nas temáticas da intervenção mamária, otimização da dose e controlo da qualidade. A maioria dos inquiridos concorda com a necessidade de certificação da prática da mamografia em Portugal e participaria num programa voluntário. ABSTRACT - Introduction – Mammography is the gold standard for screening and imaging diagnosis of breast disease. It is the imaging modality recommended by screening programs in various countries in Europe and the United States. The implementation of the digital technology promoted changes in mammography practice and triggered the need to adjust quality control programs. Aims –Characterize the technology for mammography installed in Portugal. Assess practice in use in mammography and its harmonization and compliance to international guidelines. Identify optimization needs to promote an effective and efficient use of digital mammography to full potential. Methodology – Literature review was performed. Data was collected from official sources (governmental bodies, mammography healthcare providers and medical imaging industry) regarding the number and specifications of mammography equipment installed in Portugal. Three questionnaires targeted at radiologists, breast radiographers and the chief-radiographer were designed for data collection on the technical and clinical practices in mammography. The questionnaires were delivered in a sample of 65 mammography providers selected according to geographical criteria, type of technology and institution profile. Results – Results revealed 441 mammography systems installed in Portugal. The most frequent (62%) technology type are computerized systems (CR) mostly installed in the private sector (78%). 12% are direct radiography systems (DDR). The criteria for selection of the exposure parameters differ between the institutions with the majority (65%) following the recommendations from the manufacturers. The use of available tools for post-processing is limited being the most frequently reported tools used the contrast/ brightness and Zoom or Pan Magnification tools. Fifteen participant institutions (out of 19) have implemented a quality control programme. Conclusions – The technology for mammography in Portugal is heterogeneous and includes both obsolete and state of the art equipment. International guidelines (European or American) are not formally implemented and the manufacturer recommendations are the most frequently used guidance. Education and training needs were identified amongst the healthcare professionals (radiologists and radiographers) with focus in the areas of mammography intervention, patient dose optimization and quality control. The majority of the participants agree with the certification of mammography in Portugal.
Resumo:
Developments in digital detector technologies have been taking place and new digital technologies are available for clinical practice. This chapter is intended to give a technical state-of-the-art overview about computed radiography (CR) and digital radiography (DR) detectors. CR systems use storage-phosphor image plates with a separate image readout process and DR technology converts X-rays into electrical charges by means of a readout process using TFT arrays. Digital detectors offer several advantages when compared to analogue detectors. The knowledge about digital detector technology for use in plain radiograph examinations is thus a fundamental topic to be acquired by radiology professionals and students. In this chapter an overview of digital radiography systems (both CR and DR) currently available for clinical practice is provided.
Resumo:
The characterization of physical properties of digital imaging systems requires the determination and measurement of detectors’ physical performance. Those measures such as modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) provide objective evaluations of digital detectors’ performance. To provide an MTF, NPS, and DQE calculation from raw-data images it is necessary to implement a method that is undertaken by two major steps: (1) image acquisition and (2) quantitative measure determination method. In this chapter a comprehensive description about a method to provide the measure of performance of digital radiography detectors is provided.
Resumo:
This chapter addresses technical issues concerning digital technologies. Radiological equipment and technique are briefly introduced together with a discussion about requirements and advantages of digital technologies. Digital technologies offer several advantages when compared to conventional analogical systems, or screen–film (SF) systems. While in clinical practice the practitioners should be aware of technical factors such as image acquisition, management of patient dose, and diagnostic image quality. Thus, digital technologies require an up-to-date scientific knowledge concerning their use in projection radiography. In this chapter, technical considerations concerning digital technologies are provided.
Resumo:
Once in a digital form, a radiographic image may be processed in several ways in order to turn the visualization an act of improved diagnostic value. Practitioners should be aware that, depending on each clinical context, digital image processing techniques are available to help to unveil visual information that is, in fact, carried by the bare digital radiograph and may be otherwise neglected. The range of visual enhancement procedures includes simple techniques that deal with the usual brightness and contrast manipulation up to much more elaborate multi-scale processing that provides customized control over the emphasis given to the relevant finer anatomical details. This chapter is intended to give the reader a practical understanding of image enhancement techniques that might be helpful to improve the visual quality of the digital radiographs and thus to contribute to a more reliable and assertive reporting.
Resumo:
Plain radiography still accounts for the vast majority of imaging studies that are performed at multiple clinical instances. Digital detectors are now prominent in many imaging facilities and they are the main driving force towards filmless environments. There has been a working paradigm shift due to the functional separation of acquisition, visualization, and storage with deep impact in the imaging workflows. Moreover with direct digital detectors images are made available almost immediately. Digital radiology is now completely integrated in Picture Archiving and Communication System (PACS) environments governed by the Digital Imaging and Communications in Medicine (DICOM) standard. In this chapter a brief overview of PACS architectures and components is presented together with a necessarily brief account of the DICOM standard. Special focus is given to the DICOM digital radiology objects and how specific attributes may now be used to improve and increase the metadata repository associated with image data. Regular scrutiny of the metadata repository may serve as a valuable tool for improved, cost-effective, and multidimensional quality control procedures.
Resumo:
Collaborative Work plays an important role in today’s organizations, especially in areas where decisions must be made. However, any decision that involves a collective or group of decision makers is, by itself complex, but is becoming recurrent in recent years. In this work we present the VirtualECare project, an intelligent multi-agent system able to monitor, interact and serve its customers, which are, normally, in need of care services. In last year’s there has been a substantially increase on the number of people needed of intensive care, especially among the elderly, a phenomenon that is related to population ageing. However, this is becoming not exclusive of the elderly, as diseases like obesity, diabetes and blood pressure have been increasing among young adults. This is a new reality that needs to be dealt by the health sector, particularly by the public one. Given this scenarios, the importance of finding new and cost effective ways for health care delivery are of particular importance, especially when we believe they should not to be removed from their natural “habitat”. Following this line of thinking, the VirtualECare project will be presented, like similar ones that preceded it. Recently we have also assisted to a growing interest in combining the advances in information society - computing, telecommunications and presentation – in order to create Group Decision Support Systems (GDSS). Indeed, the new economy, along with increased competition in today’s complex business environments, takes the companies to seek complementarities in order to increase competitiveness and reduce risks. Under these scenarios, planning takes a major role in a company life. However, effective planning depends on the generation and analysis of ideas (innovative or not) and, as a result, the idea generation and management processes are crucial. Our objective is to apply the above presented GDSS to a new area. We believe that the use of GDSS in the healthcare arena will allow professionals to achieve better results in the analysis of one’s Electronically Clinical Profile (ECP). This achievement is vital, regarding the explosion of knowledge and skills, together with the need to use limited resources and get better results.
Resumo:
Mestrado em Relações Internacionais.
Resumo:
Radiotherapy (RT) is one of the most important approaches in the treatment of cancer and its performance can be improved in three different ways: through the optimization of the dose distribution, by the use of different irradiation techniques or through the study of radiobiological initiatives. The first is purely physical because is related to the physical dose distributiuon. The others are purely radiobiological because they increase the differential effect between the tumour and the health tissues. The Treatment Planning Systems (TPS) are used in RT to create dose distributions with the purpose to maximize the tumoral control and minimize the complications in the healthy tissues. The inverse planning uses dose optimization techniques that satisfy the criteria specified by the user, regarding the target and the organs at risk (OAR’s). The dose optimization is possible through the analysis of dose-volume histograms (DVH) and with the use of computed tomography, magnetic resonance and other digital image techniques.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial