980 resultados para Diagnostic imaging services


Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study examines the role of glucose and lactate as energy substrates to sustain synaptic vesicle cycling. Synaptic vesicle turnover was assessed in a quantitative manner by fluorescence microscopy in primary cultures of mouse cortical neurons. An electrode-equipped perfusion chamber was used to stimulate cells both by electrical field and potassium depolarization during image acquisition. An image analysis procedure was elaborated to select in an unbiased manner synaptic boutons loaded with the fluorescent dye N-(3-triethylammoniumpropyl)-4-(4-(dibutylamino)styryl)pyridinium dibromide (FM1-43). Whereas a minority of the sites fully released their dye content following electrical stimulation, others needed subsequent K(+) depolarization to achieve full release. This functional heterogeneity was not significantly altered by the nature of metabolic substrates. Repetitive stimulation sequences of FM1-43 uptake and release were then performed in the absence of any metabolic substrate and showed that the number of active sites dramatically decreased after the first cycle of loading/unloading. The presence of 1 mM glucose or lactate was sufficient to sustain synaptic vesicle cycling under these conditions. Moreover, both substrates were equivalent for recovery of function after a phase of decreased metabolic substrate availability. Thus, lactate appears to be equivalent to glucose for sustaining synaptic vesicle turnover in cultured cortical neurons during activity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Parallel tracks for clinical scientists, basic scientists, and pediatric imagers was the novel approach taken for the highly successful 8th Annual Scientific Sessions of the Society for Cardiovascular Magnetic Resonance, held in San Francisco, California, January 21 to 23, 2005. Attendees were immersed in information on the latest scientific advances in cardiovascular magnetic resonance (CMR) from mice to man and technological advances from systems with field strengths from 0.5 T to 11.7 T. State-of-the-art applications were reviewed, spanning a wide range from molecular imaging to predicting outcome with CMR in large patient populations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The widespread use of abdominal imaging technologies has led to an increase in the incidental finding of liver tumors. Most of these lesions are asymptomatic and will not require any treatment. With the use of contrast-enhanced radiological studies, most of the tumors can be reliably diagnosed by non-invasive means. In case of diagnostic uncertainty, patients should not undergo percutaneous biopsy but rather complete resection of the lesion for an unequivocal diagnosis. Such pathologies must be taken charge of in centers with expertise by interdisciplinary teams.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A precise knowledge of arterial, portal, hepatic and biliary anatomical variations is mandatory when a liver intervention is planned. However, only certain variations must be searched when a precise intervention is planned. The basic liver anatomy as well as the most relevant malformations will be precised.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY/PRINCIPLES: After arterial ischemic stroke (AIS) an early diagnosis helps preserve treatment options that are no longer available later. Paediatric AIS is difficult to diagnose and often the time to diagnosis exceeds the time window of 6 hours defined for thrombolysis in adults. We investigated the delay from the onset of symptoms to AIS diagnosis in children and potential contributing factors. METHODS: We included children with AIS below 16 years from the population-based Swiss Neuropaediatric Stroke Registry (2000-2006). We evaluated the time between initial medical evaluation for stroke signs/symptoms and diagnosis, risk factors, co-morbidities and imaging findings. RESULTS: A total of 91 children (61 boys), with a median age of 5.3 years (range: 0.2-16.2), were included. The time to diagnosis (by neuro-imaging) was <6 hours in 32 (35%), 6-12 hours in 23 (25%), 12-24 hours in 15 (16%) and >24 hours in 21 (23%) children. Of 74 children not hospitalised when the stroke occurred, 42% had adequate outpatient management. Delays in diagnosis were attributed to: parents/caregivers (n = 20), physicians of first referral (n = 5) and tertiary care hospitals (n = 8). A co-morbidity hindered timely diagnosis in eight children. No other factors were associated with delay to diagnosis. A total of 17 children were inpatients at AIS onset. CONCLUSIONS: One-third of children with AIS were diagnosed within six hours. Diagnostic delay was predominately caused by insufficient recognition of stroke symptoms. Increased public and expert awareness and immediate access to diagnostic imaging are essential. The ability of parents/caregivers and health professionals to recognise stroke symptoms in a child needs to be improved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Autosomal dominant polycystic kidney disease is one of the most prevalent genetic diseases and every general practitioner may have to counsel these patients. The follow-up of the patients carrying the trait has changed substantially lately and new treatments have been developed and are close to get approval. We review here the new ultrasound diagnostic criteria, the place of the renal volumetry by MRI in the follow-up, the place of the genetic molecular diagnosis and we discuss the pathogenesis and the future treatment that are in phase III clinical studies and will soon change completely the outcome of the disease.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Crohn's disease (CD) is a chronic progressive destructive disease. Currently available instruments measure disease activity at a specific point in time. An instrument to measure cumulative structural damage to the bowel, which may predict long-term disability, is needed. The aim of this article is to outline the methods to develop an instrument that can measure cumulative bowel damage. The project is being conducted by the International Program to develop New Indexes in Crohn's disease (IPNIC) group. This instrument, called the Crohn's Disease Digestive Damage Score (the Lémann score), should take into account damage location, severity, extent, progression, and reversibility, as measured by diagnostic imaging modalities and the history of surgical resection. It should not be "diagnostic modality driven": for each lesion and location, a modality appropriate for the anatomic site (for example: computed tomography or magnetic resonance imaging enterography, and colonoscopy) will be used. A total of 24 centers from 15 countries will be involved in a cross-sectional study, which will include up to 240 patients with stratification according to disease location and duration. At least 120 additional patients will be included in the study to validate the score. The Lémann score is expected to be able to portray a patient's disease course on a double-axis graph, with time as the x-axis, bowel damage severity as the y-axis, and the slope of the line connecting data points as a measure of disease progression. This instrument could be used to assess the effect of various medical therapies on the progression of bowel damage. (Inflamm Bowel Dis 2011).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We have developed a technetium labeling technology based on a new organometallic chemistry, which involves simple mixing of the novel reagent, a 99m Tc(I)-carbonyl compound, with a His-tagged recombinant protein. This method obviates the labeling of unpaired engineered cysteines, which frequently create problems in large-scale expression and storage of disulfide-containing proteins. In this study, we labeled antibody single-chain Fv fragments to high specific activities (90 mCi/mg), and the label was very stable to serum and all other challenges tested. The pharmacokinetic characteristics were indistinguishable from iodinated scFv fragments, and thus scFV fragments labeled by the new method will be suitable for biodistribution studies. This novel labeling method should be applicable not only to diagnostic imaging with 99mTc, but also to radioimmunotherapy approaches with 186/188 Re, and its use can be easily extended to almost any recombinant protein or synthetic peptide.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study was designed to evaluate the potential of gas-filled microbubbles (MB) to be internalized by antigen-presenting cells (APC). Fluorescently labeled MB were prepared, thus permitting to track binding to, and internalization in, APC. Both human and mouse cells, including monocytes and dendritic cells (DC), prove capable to phagocyte MB in vitro. Observation by confocal laser scanning microscopy showed that interaction between MB and target cells resulted in a rapid internalization in cellular compartments and to a lesser extent in the cytoplasm. Capture of MB by APC resulted in phagolysosomal targeting as verified by double staining with anti-lysosome-associated membrane protein-1 monoclonal antibody and decrease of internalization by phagocytosis inhibitors. Fluorescent MB injected subcutaneously (s.c.) in mice were found to be associated with CD11c(+)DC in lymph nodes draining the injection sites 24 h after administration. Altogether, our study demonstrates that MB can successfully target APC both in vitro and in vivo, and thus may serve as a potent Ag delivery system without requirement for ultrasound-based sonoporation. This adds to the potential of applications of MB already extensively used for diagnostic imaging in humans.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND/AIMS/METHODS During hepatic vein catheterisation, in addition to measurement of hepatic venous pressure gradient (HVPG), iodine wedged retrograde portography can be easily obtained. However, it rarely allows correct visualisation of the portal vein. Recently, CO2 has been suggested to allow better angiographic demonstration of the portal vein than iodine. In this study we investigated the efficacy of CO2 compared with iodinated contrast medium for portal vein imaging and its role in the evaluation of portal hypertension in a series of 100 patients undergoing hepatic vein catheterisation, 71 of whom had liver cirrhosis. RESULTS In the overall series, CO2 venography was markedly superior to iodine, allowing correct visualisation of the different segments of the portal venous system. In addition, CO2, but not iodine, visualised portal-systemic collaterals in 34 patients. In cirrhosis, non-visualisation of the portal vein on CO2 venography occurred in 11 cases; four had portal vein thrombosis and five had communications between different hepatic veins. Among non-cirrhotics, lack of portal vein visualisation had a 90% sensitivity, 88% specificity, 94% negative predictive value, and 83% positive predictive value in the diagnosis of pre-sinusoidal portal hypertension. CONCLUSIONS Visualisation of the venous portal system by CO2 venography is markedly superior to iodine. The use of CO2 wedged portography is a useful and safe complementary procedure during hepatic vein catheterisation which may help to detect portal thrombosis. Also, lack of demonstration of the portal vein in non-cirrhotic patients strongly suggests the presence of pre-sinusoidal portal hypertension.