967 resultados para Detectors.
Resumo:
The most promising concept for low frequency (millihertz to hertz) gravitational wave observatories are laser interferometric detectors in space. It is usually assumed that the noise floor for such a detector is dominated by optical shot noise in the signal readout. For this to be true, a careful balance of mission parameters is crucial to keep all other parasitic disturbances below shot noise. We developed a web application that uses over 30 input parameters and considers many important technical noise sources and noise suppression techniques to derive a realistic position noise budget. It optimizes free parameters automatically and generates a detailed report on all individual noise contributions. Thus one can easily explore the entire parameter space and design a realistic gravitational wave observatory. In this document we describe the different parameters, present all underlying calculations, and compare the final observatory's sensitivity with astrophysical sources of gravitational waves. We use as an example parameters currently assumed to be likely applied to a space mission proposed to be launched in 2034 by the European Space Agency. The web application itself is publicly available on the Internet at http://spacegravity.org/designer. Future versions of the web application will incorporate the frequency dependence of different noise sources and include a more detailed model of the observatory's residual acceleration noise.
Resumo:
2016
Resumo:
Testing of summing electronics and VDC A/D Cards was performed to assure proper functioning and operation within defined parameters. In both the summing modules and the VDC A/D cards, testing for minimum threshold voltage for each channel and crosstalk between neighboring channels was performed. Additionally, the modules were installed in Hall A with input signals from shower detectors arranged to establish a trigger by summing signals together with the use of tested modules. Testing involved utilizing a pulser to mimic PMT signals, a discriminator, an attenuator, a scaler, a level translator, an oscilloscope, a high voltage power supply, and a special apparatus used to power and send signal to the A/D cards. After testing, modules were obtained that meet necessary criteria for use in the APEX experiment, and the A/D cards obtained were determined to have adequate specifications for their utilization, with specific results included in the appendix.
Resumo:
Ionizing radiations are important tools employed every day in the modern society. For example, in medicine they are routinely used for diagnostic and therapy. The large variety of applications leads to the need of novel, more efficient, low-cost ionizing radiation detectors with new functionalities. Personal dosimetry would benefit from wearable detectors able to conform to the body surfaces. Traditional semiconductors used for ionizing radiation direct detectors offer high performance but they are intrinsically stiff, brittle and require high voltages to operate. Hybrid lead-halide perovskites emerged recently as a novel class of materials for ionizing radiation detection. They combine high absorption coefficient, solution processability and high charge transport capability, enabling efficient and low-cost detection. The deposition from solution allows the fabrication of thin-film flexible devices. In this thesis, I studied the detection properties of different types of hybrid perovskites, deposited from solution in thin-film form, and tested under X-rays, gamma-rays and protons beams. I developed the first ultraflexible X-ray detector with exceptional conformability. The effect of coupling organic layers with perovskites was studied at the nanoscale giving a direct demonstration of trap passivation effect at the grain boundaries. Different perovskite formulations were deposited and tested to improve the film stability. I report about the longest aging studies on perovskite X-ray detectors showing that the addition of starch in the precursors’ solution can improve the stability in time with only a 7% decrease in sensitivity after 630 days of storage in ambient conditions. 2D perovskites were also explored as direct detector for X-rays and gamma-rays. Detection of 511 keV photons by a thin-film device is here demonstrated and was validated for monitoring a radiotracer injection. At last, a new approach has been used: a 2D/3Dmixed perovskite thin-film demonstrated to reliably detect 5 MeV protons, envisioning wearable dose monitoring during proton/hadron therapy treatments.
Resumo:
From 2010, the Proton Radius has become one of the most interest value to determine. The first proof of not complete understanding of its internal structure was the measurement of the Lamb Shift using the muonic hydrogen, leading to a value 7σ lower. A new road so was open and the Proton Radius Puzzle epoch begun. FAMU Experiment is a project that tries to give an answer to this Puzzle implementing high precision experimental apparatus. The work of this thesis is based on the study, construction and first characterization of a new detection system. Thanks to the previous experiments and simulations, this apparatus is composed by 17 detectors positioned on a semicircular crown with the related electronic circuit. The detectors' characterization is based on the use of a LabView program controlling a digital potentiometer and on other two analog potentiometers, all three used to set the amplitude of each detector to a predefined value, around 1.2 V, set on the oscilloscope by which is possible to observe the signal. This is the requirement in order to have, in the final measurement, a single high peak given by the sum of all the signals coming from the detectors. Each signal has been acquired for almost half of an hour, but the entire circuit has been maintained active for more time to observe its capacity to work for longer periods. The principal results of this thesis are given by the spectra of 12 detectors and the corresponding values of Voltages, FWHM and Resolution. The outcomes of the acquisitions show also another expected behavior: the strong dependence of the detectors from the temperature, demonstrating that an its change causes fluctuations in the signal. In turn, these fluctuations will affect the spectrum, resulting in a shifting of the curve and a lower Resolution. On the other hand, a measurement performed in stable conditions will lead to accordance between the nominal and experimental measurements, as for the detectors 10, 11 and 12 of our system.
Resumo:
The corpuscular model describes black holes as leaky bound states of gravitons. To account for the role of matter, a coherent state is built and a semiclassical description is given to the gravitational field by connecting the classical source with the quantum state for gravitons. The properties of this state can be analysed with the help of an Unruh-DeWitt detector, coupled to the quantum state of the system. The presence of a detector in general regularises the usual diverging behaviour of the field in the deep ultraviolet region, and will allow us to probe the coherent state structure and the graviton emission. In particular, a Newtonian analogue of the Unruh effect will be discussed and the coherent state will be modified to properly account for the spherical symmetry of the potential at the level of the quantum state. This correction will ensure that vacuum contributions responsible for the Unruh thermal spectrum are present in a coherent state emission process.
Resumo:
The incompatibility between the proton radius values measured in recent years has given rise to what is now called the proton radius puzzle. This discrepancy is nowadays without explanation. In order to find a solution to the proton radius puzzle a new experiment has been proposed. The aim of this experiment, called FAMU, is to obtain a new and more precise measure of the Zemach radius of the proton, ie the quantity that has the highest uncertainty in high precision spectroscopy. If this measurement confirmed the results obtained before 2010, the starting date of the puzzle, then the discrepancy would be caused by procedural errors or ignored corrections. Otherwise, the new value would indicate the presence of new physics still unkown.
Resumo:
A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.
Resumo:
Raman imaging spectroscopy is a highly useful analytical tool that provides spatial and spectral information on a sample. However, CCD detectors used in dispersive instruments present the drawback of being sensitive to cosmic rays, giving rise to spikes in Raman spectra. Spikes influence variance structures and must be removed prior to the use of multivariate techniques. A new algorithm for correction of spikes in Raman imaging was developed using an approach based on comparison of nearest neighbor pixels. The algorithm showed characteristics including simplicity, rapidity, selectivity and high quality in spike removal from hyperspectral images.
Resumo:
Dynamical Chern-Simons gravity is an extension of general relativity in which the gravitational field is coupled to a scalar field through a parity-violating Chern-Simons term. In this framework, we study perturbations of spherically symmetric black hole spacetimes, assuming that the background scalar field vanishes. Our results suggest that these spacetimes are stable, and small perturbations die away as a ringdown. However, in contrast to standard general relativity, the gravitational waveforms are also driven by the scalar field. Thus, the gravitational oscillation modes of black holes carry imprints of the coupling to the scalar field. This is a smoking gun for Chern-Simons theory and could be tested with gravitational-wave detectors, such as LIGO or LISA. For negative values of the coupling constant, ghosts are known to arise, and we explicitly verify their appearance numerically. Our results are validated using both time evolution and frequency domain methods.
Resumo:
The magnetized MINOS Near Detector, at a depth of 225 mwe, is used to measure the atmospheric muon charge ratio. The ratio of observed positive to negative atmospheric muon rates, using 301 days of data, is measured to be 1.266 +/- 0.001(stat)(-0.014)(+0.015)(syst). This measurement is consistent with previous results from other shallow underground detectors and is 0.108 +/- 0.019(stat + syst) lower than the measurement at the functionally identical MINOS Far Detector at a depth of 2070 mwe. This increase in charge ratio as a function of depth is consistent with an increase in the fraction of muons arising from kaon decay for increasing muon surface energies.
Resumo:
A search for depletion of the combined flux of active neutrino species over a 735 km baseline is reported using neutral-current interaction data recorded by the MINOS detectors in the NuMI neutrino beam. Such a depletion is not expected according to conventional interpretations of neutrino oscillation data involving the three known neutrino flavors. A depletion would be a signature of oscillations or decay to postulated noninteracting sterile neutrinos, scenarios not ruled out by existing data. From an exposure of 3.18 x 10(20) protons on target in which neutrinos of energies between similar to 500 MeV and 120 GeV are produced predominantly as nu(mu), the visible energy spectrum of candidate neutral-current reactions in the MINOS far detector is reconstructed. Comparison of this spectrum to that inferred from a similarly selected near-detector sample shows that of the portion of the nu(mu) flux observed to disappear in charged-current interaction data, the fraction that could be converting to a sterile state is less than 52% at 90% confidence level (C. L.). The hypothesis that active neutrinos mix with a single sterile neutrino via oscillations is tested by fitting the data to various models. In the particular four-neutrino models considered, the mixing angles theta(24) and theta(34) are constrained to be less than 11 degrees and 56 degrees at 90% C. L., respectively. The possibility that active neutrinos may decay to sterile neutrinos is also investigated. Pure neutrino decay without oscillations is ruled out at 5.4 standard deviations. For the scenario in which active neutrinos decay into sterile states concurrently with neutrino oscillations, a lower limit is established for the neutrino decay lifetime tau(3)/m(3) > 2.1 x 10(-12) s/eV at 90% C.L.