891 resultados para Design methods


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract: This paper presents the details of a study into the behaviour and moment capacities of cold-formed steel lipped channel beams (LCB) subject to lateral-torsional buckling at elevated temperatures. It was based on a validated numerical model of a simply supported and laterally unrestrained LCB subjected to a uniform moment. The ultimate moment capacities from this study were compared with the predicted values using ambient and fire design methods. This study showed that the lateral torsional buckling capacity is strongly influenced by the level of non-linearity in the stress-strain curves of steel at elevated temperatures. Hence most of the current design methods based on a single buckling curve were not adequate to determine the moment capacities. This paper proposes a new design method for the cold-formed steel LCBs subject lateral-torsional buckling at elevated temperatures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Light gauge cold-formed steel frame (LSF) structures are increasingly used in industrial, commercial and residential buildings because of their non-combustibility, dimensional stability, and ease of installation. A floor-ceiling system is an example of its applications. LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite panel in which an external insulation layer is used between two plasterboards has been developed at QUT to provide a higher fire rating to LSF floors under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Research on LSF floor systems under fire conditions is relatively recent and the behaviour of floor joists and other components in the systems is not fully understood. The present design methods thus require the use of expensive fire protection materials to protect them from excessive heat increase during a fire. This leads to uneconomical and conservative designs. Fire rating of these floor systems is provided simply by adding more plasterboard sheets to the steel joists and such an approach is totally inefficient. Hence a detailed fire research study was undertaken into the structural and thermal performance of LSF floor systems including those protected by the new composite panel system using full scale fire tests and extensive numerical studies. Experimental study included both the conventional and the new steel floor-ceiling systems under structural and fire loads using a gas furnace designed to deliver heat in accordance with the standard time- temperature curve in AS 1530.4 (SA, 2005). Fire tests included the behavioural and deflection characteristics of LSF floor joists until failure as well as related time-temperature measurements across the section and along the length of all the specimens. Full scale fire tests have shown that the structural and thermal performance of externally insulated LSF floor system was superior than traditional LSF floors with or without cavity insulation. Therefore this research recommends the use of the new composite panel system for cold-formed LSF floor-ceiling systems. The numerical analyses of LSF floor joists were undertaken using the finite element program ABAQUS based on the measured time-temperature profiles obtained from fire tests under both steady state and transient state conditions. Mechanical properties at elevated temperatures were considered based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). Finite element models were calibrated using the full scale test results and used to further provide a detailed understanding of the structural fire behaviour of the LSF floor-ceiling systems. The models also confirmed the superior performance of the new composite panel system. The validated model was then used in a detailed parametric study. Fire tests and the numerical studies showed that plasterboards provided sufficient lateral restraint to LSF floor joists until their failure. Hence only the section moment capacity of LSF floor joists subjected to local buckling effects was considered in this research. To predict the section moment capacity at elevated temperatures, the effective section modulus of joists at ambient temperature is generally considered adequate. However, this research has shown that it leads to considerable over- estimation of the local buckling capacity of joist subject to non-uniform temperature distributions under fire conditions. Therefore new simplified fire design rules were proposed for LSF floor joist to determine the section moment capacity at elevated temperature based on AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The accuracy of the proposed fire design rules was verified with finite element analysis results. A spread sheet based design tool was also developed based on these design rules to predict the failure load ratio versus time, moment capacity versus time and temperature for various LSF floor configurations. Idealised time-temperature profiles of LSF floor joists were developed based on fire test measurements. They were used in the detailed parametric study to fully understand the structural and fire behaviour of LSF floor panels. Simple design rules were also proposed to predict both critical average joist temperatures and failure times (fire rating) of LSF floor systems with various floor configurations and structural parameters under any given load ratio. Findings from this research have led to a comprehensive understanding of the structural and fire behaviour of LSF floor systems including those protected by the new composite panel, and simple design methods. These design rules were proposed within the guidelines of the Australian/New Zealand, American and European cold- formed steel structures standard codes of practice. These may also lead to further improvements to fire resistance through suitable modifications to the current composite panel system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: The purpose of this research is to examine School Based Youth Health Nurses experience of a true health promotion approach. Background: The School Based Youth Health Nurse Program is a state-wide school nursing initiative in Queensland, Australia. The program employs more than 120 fulltime and fractional school nurses who provide health services in state high schools. The role incorporates two primary components: individual health consultations and health promotion strategies. Design/Methods: This study is a retrospective inquiry generated from a larger qualitative research project about the experience of school based youth health nursing. The original methodology was phenomenography. In-depth interviews were conducted with sixteen school nurses recruited through purposeful and snowball sampling. This study accesses a specific set of raw data about School Based Youth Health Nurses experience of a true health promotion approach. The Ottawa Charter for Health Promotion (1986) is used as a framework for deductive analysis. Results: The findings indicate school nurses have neither an adverse or affirmative conceptual experience of a true health promotion approach and an adverse operational experience of a true health promotion approach based on the action areas of the Ottawa Charter. Conclusions: The findings of this research are important because they challenge the notion that school nurses are the most appropriate health professionals to undertake a true health promotion approach. If school nurses are the most appropriate health professionals to do a true health promotion approach, there are implications for recruitment and training and qualifications. If school nurses are not, who are the most appropriate health professionals to do school health promotion? Implications for Practice: These findings can be applied to other models of school nursing in Australia which emphasises a true health promotion approach because they relate specifically to school nurses’ experience of a true health promotion approach.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper we introduce the idea of "social contraptions", which are interactive physical devices employed as designerly explorations of social relations as mediated by physical space and artefacts. We present two independent but related design explorations that were situated in fine art and industrial research contexts. We argue that these contraptions open up for exploration some interaction issues related to the theme of ’Embodied Facilitation'. This is particularly in relation to awareness and coordination between interactants as mediated by the spatial and material configuration of the contraptions. These methods, as well as the insights gained from them can contribute to the development of the emerging field of embodied interaction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The well-known power system stabilizer (PSS) is used to generate supplementary control signals for the excitation system of a generator so as to damp low frequency oscillations in the power system concerned. Up to now, various kinds of PSS design methods have been proposed and some of them applied in actual power systems with different degrees. Given this background, the small-disturbance eigenvalue analysis and large-disturbance dynamic simulations in the time domain are carried out to evaluate the performances of four different PSS design methods, including the Conventional PSS (CPSS), Single-Neuron PSS (SNPSS), Adaptive PSS (APSS) and Multi-band PSS (MBPSS). To make the comparisons equitable, the parameters of the four kinds of PSSs are all determined by the steepest descent method. Finally, an 8-unit 24-bus power system is employed to demonstrate the performances of the four kinds of PSSs by the well-established eigenvalue analysis as well as numerous digital simulations, and some useful conclusions obtained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to develop more inclusive products and services, designers need a means of assessing the inclusivity of existing products and new concepts. Following previous research on the development of scales for inclusive design at University of Cambridge, Engineering Design Centre (EDC) [1], this paper presents the latest version of the exclusion audit method. For a specific product interaction, this estimates the proportion of the Great British population who would be excluded from using a product or service, due to the demands the product places on key user capabilities. A critical part of the method involves rating of the level of demand placed by a task on a range of key user capabilities, so the procedure to perform this assessment was operationalised and then its reliability was tested with 31 participants. There was no evidence that participants rated the same demands consistently. The qualitative results from the experiment suggest that the consistency of participants’ demand level ratings could be significantly improved if the audit materials and their instructions better guided the participant through the judgement process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Application of "advanced analysis" methods suitable for non-linear analysis and design of steel frame structures permits direct and accurate determination of ultimate system strengths, without resort to simplified elastic methods of analysis and semi-empirical specification equations. However, the application of advanced analysis methods has previously been restricted to steel frames comprising only compact sections that are not influenced by the effects of local buckling. A refined plastic hinge method suitable for practical advanced analysis of steel frame structures comprising non-compact sections is presented in a companion paper. The method implicitly accounts for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. The accuracy and precision of the method for the analysis of steel frames comprising non-compact sections is established in this paper by comparison with a comprehensive range of analytical benchmark frame solutions. The refined plastic hinge method is shown to be more accurate and precise than the conventional individual member design methods based on elastic analysis and specification equations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Application of `advanced analysis' methods suitable for non-linear analysis and design of steel frame structures permits direct and accurate determination of ultimate system strengths, without resort to simplified elastic methods of analysis and semi-empirical specification equations. However, the application of advanced analysis methods has previously been restricted to steel frames comprising only compact sections that are not influenced by the effects of local buckling. A concentrated plasticity method suitable for practical advanced analysis of steel frame structures comprising non-compact sections is presented in this paper. The pseudo plastic zone method implicitly accounts for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. The accuracy and precision of the method for the analysis of steel frames comprising non-compact sections is established by comparison with a comprehensive range of analytical benchmark frame solutions. The pseudo plastic zone method is shown to be more accurate and precise than the conventional individual member design methods based on elastic analysis and specification equations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims and objectives. To present a novel approach to nurse stress by exploring the demand–control–support model with organisational justice through the lens of relational regulation theory. Background. Nursing is often stressful due to high demands and dissatisfaction with pay, which impacts the mental well-being and productivity of nurses. Design. A cross-sectional design. Methods. A validated questionnaire was sent to the work addresses of all nursing and midwifery staff in a medium-sized general acute hospital in Australia. A total of 190 nurses and midwives returned completed questionnaires for the analyses. Results. The multiple regression analyses demonstrated that the model applies to the prototypical context of a general acute hospital and that job control, supervisor support and outside work support improve the job satisfaction and mental health of nurses. Conclusions. Most importantly, supervisor support was found to buffer the impact of excessive work demands. Fairness of procedures, distribution of resources and the quality and consistency of information are also beneficial. Relational regulation theory is applied to these findings as a novel way to conceptualise the mechanisms of support and fairness in nursing. Relevance to clinical practice. The importance of nurses’ well-being and job satisfaction is a priority for improving clinical outcomes. Practically, this means nurse managers should be encouraging nurses in the pursuit of diverse relational activities both at work and outside work.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a higher-order beam-column formulation that can capture the geometrically non-linear behaviour of steel framed structures which contain a multiplicity of slender members. Despite advances in computational frame software, analyses of large frames can still be problematic from a numerical standpoint and so the intent of the paper is to fulfil a need for versatile, reliable and efficient non-linear analysis of general steel framed structures with very many members. Following a comprehensive review of numerical frame analysis techniques, a fourth-order element is derived and implemented in an updated Lagrangian formulation, and it is able to predict flexural buckling, snap-through buckling and large displacement post-buckling behaviour of typical structures whose responses have been reported by independent researchers. The solutions are shown to be efficacious in terms of a balance of accuracy and computational expediency. The higher-order element forms a basis for augmenting the geometrically non-linear approach with material non-linearity through the refined plastic hinge methodology described in the companion paper.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the companion paper, a fourth-order element formulation in an updated Lagrangian formulation was presented to handle geometric non-linearities. The formulation of the present paper extends this to include material non-linearity by proposing a refined plastic hinge approach to analyse large steel framed structures with many members, for which contemporary algorithms based on the plastic zone approach can be problematic computationally. This concept is an advancement of conventional plastic hinge approaches, as the refined plastic hinge technique allows for gradual yielding, being recognized as distributed plasticity across the element section, a condition of full plasticity, as well as including strain hardening. It is founded on interaction yield surfaces specified analytically in terms of force resultants, and achieves accurate and rapid convergence for large frames for which geometric and material non-linearity are significant. The solutions are shown to be efficacious in terms of a balance of accuracy and computational expediency. In addition to the numerical efficiency, the present versatile approach is able to capture different kinds of material and geometric non-linearities on general applications of steel structures, and thereby it offers an efficacious and accurate means of assessing non-linear behaviour of the structures for engineering practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Detailed procedure for second-order analysis has been coded in the newest Eurocode 3 and the Hong Kong steel code (2005). The effective length method has been noted to be inapplicable to analysis of shallow domes of imperfect members exhibiting snap-through buckling, to portals with leaning columns and others. On the other hand, the advanced analysis is not limited to buckling design of these structures. This paper demonstrates its application to the design of a simple plane sway portal and a three diminsional non-sway steel building. The results by the advanced analysis and the first-order linear analysis are compared and the technique for practical second-order analysis steel structures is described. It is observed that the use of a straight element by itself cannot model the buckling resistance of columns governed by different buckling curves for hot-rolled and cold-formed sections of various shapes like I, H, hollow etc. Also the curvature of the conventional cubic Hermite element is not varied by the external axial force and thus it cannot simulate the response of a buckling column. Thus its use for second-order analysis is basically unacceptable. A technique for additional checking of beams undergoing lateral-torsional buckling is also suggested making the advanced analysis a complete design tool for conventional steel frames.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Terrorists usually target high occupancy iconic and public buildings using vehicle borne incendiary devices in order to claim a maximum number of lives and cause extensive damage to public property. While initial casualties are due to direct shock by the explosion, collapse of structural elements may extensively increase the total figure. Most of these buildings have been or are built without consideration of their vulnerability to such events. Therefore, the vulnerability and residual capacity assessment of buildings to deliberately exploded bombs is important to provide mitigation strategies to protect the buildings' occupants and the property. Explosive loads and their effects on a building have therefore attracted significant attention in the recent past. Comprehensive and economical design strategies must be developed for future construction. This research investigates the response and damage of reinforced concrete (RC) framed buildings together with their load bearing key structural components to a near field blast event. Finite element method (FEM) based analysis was used to investigate the structural framing system and components for global stability, followed by a rigorous analysis of key structural components for damage evaluation using the codes SAP2000 and LS DYNA respectively. The research involved four important areas in structural engineering. They are blast load determination, numerical modelling with FEM techniques, material performance under high strain rate and non-linear dynamic structural analysis. The response and damage of a RC framed building for different blast load scenarios were investigated. The blast influence region for a two dimensional RC frame was investigated for different load conditions and identified the critical region for each loading case. Two types of design methods are recommended for RC columns to provide superior residual capacities. They are RC columns detailing with multi-layer steel reinforcement cages and a composite columns including a central structural steel core. These are to provide post blast gravity load resisting capacity compared to typical RC column against a catastrophic collapse. Overall, this research broadens the current knowledge of blast and residual capacity analysis of RC framed structures and recommends methods to evaluate and mitigate blast impact on key elements of multi-storey buildings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The focus of Cents and Sustainability is to respond to the call by Dr Gro Brundtland in the seminal book Our Common Future to achieve, 'a new era of economic growth - growth that is forceful and at the same time socially and environmentally sustainable'. With the 20th anniversary of Our Common Future in 2007, it is clearly time to re-examine this important work in a modern global context. Using the framework of ‘Decoupling Economic Growth from Environmental Pressures’, Cents and Sustainability investigates a range of new evidence and research in order to develop a deeper understanding of how, and under what conditions, this 'forceful sustainable growth' is possible. With an introduction by Dr Jim MacNeill (former Secretary General to the Brundtland Commission, and former Director, OECD Environment Directorate 1978 -1984), the book will carry forewords from Dr Gro Brundtland (former Chair of the World Commission on Environment and Development), Dr Rajendra Pachauri (Chief, Intergovernmental Panel on Climate Change (IPCC), and joint recipient of the 2007 Nobel Peace Prize on behalf of the IPCC), and Dr Kenneth Ruffing (former Deputy Director and Chief Economist of the OECD Environment Directorate 2000 - 2005). Beginning with a detailed explanation of decoupling theory, along with investigation into a range of issues and barriers to its achievement, the book then focuses on informing national strategies for decoupling. Then putting this into action the book focuses on five key areas of decoupling, namely greenhouse gas emissions, biodiversity, freshwater extraction, waste production, and air pollution, and in each case showing compelling evidence for significant cost effective reductions in environmental pressures. The book concludes with a detailed case study of the groundbreaking application of public interest litigation to combat air pollution in Delhi, India.