960 resultados para Dental implants surface
Resumo:
A myriad of titanium (Ti) surface modifications has been proposed to hasten the osseointegration. In this context, the aim of this study was to perform histomorphometric, cellular, and molecular analyses of the bone tissue grown in close contact with Ti implants treated by anodic spark deposition (ASD-AK). Acid-etched (AE) Ti implants either untreated or submitted to ASD-AK were placed into dog mandibles and retrieved at 3 and 8 weeks. It was noticed that both implants, AE and ASD-AK, were osseointegrated at 3 and 8 weeks. Histomorphometric analysis showed differences between treatments only for bone-to-implant contact, being higher on AE implants. Although not backed by histomorphometric results, gene expression of key bone markers was higher for bone grown in close contact with ASD-AK and for cells harvested from these fragments and cultured until subconfluence. Cell proliferation at days 7 and 10 and alkaline phosphatase activity at day 10 was higher on AE surfaces. No statistical significant difference was noticed for extracellular matrix mineralization at 17 days. Our results have shown that the Ti fixtures treated by ASD-AK allowed in vivo osseointegration and induced higher expression of key markers of osteoblast phenotype, suggesting that this surface treatment could be considered to produce implants for clinical applications. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 100A:30923098, 2012.
Resumo:
The effect of CO2 continuous laser irradiation on the surface properties of veneering porcelains has already been tested. The surface observed after laser irradiation is similar to that achieved by auto-glaze in terms of roughness and color parameters (Sgura R, et al. Dental Materials 2011;27(Suppl. 1):e72–73). The purpose of this study was to analyze the surface porosity of porcelain discs after CO2 laser treatment and compare it to auto-glaze treatment, in furnace. A morphological analysis of the porcelain surface was conducted using atomic force microscopy (AFM) and conventional optical microscopy (OM).
Resumo:
The functional capacity of osseointegrated dental implants to bear load is largely dependent on the quality of the interface between the bone and implant. Sandblasted and acid-etched (SLA) surfaces have been previously shown to enhance bone apposition. In this study, the SLA has been compared with a chemically modified SLA (modSLA) surface. The increased wettability of the modSLA surface in a protein solution was verified by dynamic contact angle analysis. Using a well-established animal model with a split-mouth experimental design, implant removal torque testing was performed to determine the biomechanical properties of the bone-implant interface. All implants had an identical cylindrical shape with a standard thread configuration. Removal torque testing was performed after 2, 4, and 8 weeks of bone healing (n = 9 animals per healing period, three implants per surface type per animal) to evaluate the interfacial shear strength of each surface type. Results showed that the modSLA surface was more effective in enhancing the interfacial shear strength of implants in comparison with the conventional SLA surface during early stages of bone healing. Removal torque values of the modSLA-surfaced implants were 8-21% higher than those of the SLA implants (p = 0.003). The mean removal torque values for the modSLA implants were 1.485 N m at 2 weeks, 1.709 N m at 4 weeks, and 1.345 N m at 8 weeks; and correspondingly, 1.231 N m, 1.585 N m, and 1.143 N m for the SLA implants. The bone-implant interfacial stiffness calculated from the torque-rotation curve was on average 9-14% higher for the modSLA implants when compared with the SLA implants (p = 0.038). It can be concluded that the modSLA surface achieves a better bone anchorage during early stages of bone healing than the SLA surface; chemical modification of the standard SLA surface likely enhances bone apposition and this has a beneficial effect on the interfacial shear strength.
Resumo:
PURPOSE: The aim of the present clinical trial was to evaluate the 12-month success rate of titanium dental implants placed in the posterior mandible and immediately loaded with 3-unit fixed partial dentures. MATERIALS AND METHODS: Patients with missing mandibular premolars and molars were enrolled in this study. To be included in the study, the implants had to show good primary stability. Implant stability was measured with resonance frequency analysis using the Osstell device (Integration Diagnostics). Implants were included in the study when the stability quotient (ISQ) exceeded 62. Clinical measurements, such as width of keratinized tissue, ISQ, and radiographic assessment of peri-implant bone crest levels, were performed at baseline and at the 12-month follow-up. The comparison between the baseline and the 12-month visits was performed with the Student t test for paired data (statistically significant at a level of alpha = 0.05). RESULTS: Forty implants with a sandblasted, large grit, acid-etched (SLA) surface (Straumann) were placed in 20 patients. At 12 months, only 1 implant had been lost because of an acute infection. The remaining 39 implants were successful, resulting in a 1-year success rate of 97.5%. Neither peri-implant bone levels, measured radiographically, nor implant stability changed significantly from baseline to the 12-month follow-up (P > .05). DISCUSSION: The immediate functional loading of implants placed in this case series study resulted in a satisfactory success rate. CONCLUSION: The findings from this clinical study showed that the placement of SLA transmucosal implants in the mandibular area and their immediate loading with 3-unit fixed partial dentures may be a safe and successful procedure.
Resumo:
BACKGROUND: Conventionally, endosseous dental implants have required 3 to 6 months of uninterrupted healing based on observations for dental implants that were characterized by a relatively smooth machined surface. Many studies have since demonstrated that implants with a roughened surface resulted in greater bone apposition, earlier bone contact, and a stronger bond between the implant and the bone, suggesting that implants with roughened surfaces could be loaded earlier than 3 to 6 months. Formal clinical studies confirmed that implants with rough surfaces can have abutments placed and be loaded occlusally as early as 6 weeks postplacement. The purpose of this prospective, human clinical investigation was to evaluate a large number of implants with a specific rough surface (sand-blasted acid-etched [SLA]) placed in everyday practice under routine private-practice conditions. METHODS: A prospective, multicenter, human clinical observational study was initiated with the goal of recruiting a minimum of 500 patients and 800 implants. The implants were to be placed and restored in predominantly private-practice settings around the world. Ninety-two practitioners in 16 countries agreed to participate, and 86 followed the study design. Patients had to be in good health, have sufficient bone to encase the implant, and agree to return for recall appointments. Exclusion criteria included heavy smoking (>10 cigarettes a day) and bone augmentation procedures at the implant site. All implants were two-piece (an abutment was to be placed after 6 weeks of healing) and were characterized by the presence of a transmucosal polished collar. Each implant had an SLA surface. All implants were positioned using a non-submerged (single-stage) surgical technique. Survival and success rates were calculated by life-table analyses. RESULTS: A total of 706 patients were enrolled and 1,406 implants were placed. In the final analyses, 590 patients with 990 implants (70.4% of those enrolled) met all inclusion criteria, including placement of an abutment and provisional restoration within 63 days of surgical placement. The majority of implants were 10 and 12 mm long (78.7%) and were placed in type II and III bone (87%). Seventy-three percent of the implants were placed in the mandible, and 27% were placed in the maxilla. The cumulative survival rate was 99.56% at 3 years and 99.26% at 5 years. The overall success rate was 99.12% at 3 years and 97.38% after 5 years. CONCLUSIONS: Under private-practice conditions, implants with an SLA surface could be placed and restored predictably within 6 to 8 weeks. Data from this prospective, multicenter, human observational study reinforced the results of more formal clinical studies and demonstrated that implants with the SLA surface can be restored in patients in approximately half of the time of conventional healing periods.
Resumo:
OBJECTIVES: The objectives of this systematic review were to assess the survival rate of grafts and implants placed with sinus floor elevation. MATERIAL AND METHODS: An electronic search was conducted to identify studies on sinus floor elevation, with a mean follow-up time of at least 1 year after functional loading. RESULTS: The search provided 839 titles. Full-text analysis was performed for 175 articles resulting in 48 studies that met the inclusion criteria, reporting on 12,020 implants. Meta-analysis indicated an estimated annual failure rate of 3.48% [95% confidence interval (CI): 2.48%-4.88%] translating into a 3-year implant survival of 90.1% (95% CI: 86.4%-92.8%). However, when failure rates was analyzed on the subject level, the estimated annual failure was 6.04% (95% CI: 3.87%-9.43%) translating into 16.6% (95% CI: 10.9%-24.6%) of the subjects experiencing implant loss over 3 years. CONCLUSION: The insertion of dental implants in combination with maxillary sinus floor elevation is a predictable treatment method showing high implant survival rates and low incidences of surgical complications. The best results (98.3% implant survival after 3 years) were obtained using rough surface implants with membrane coverage of the lateral window.
Resumo:
Osseointegration of titanium dental implants into the jaw bone, which is required for maintenance of the implant in the jaw, results in ankylosis. Dental implants are therefore very unlike natural teeth, which exhibit significant movement in response to mechanical forces. The ability to generate periodontal ligament (PDL) tissues onto dental implants would better mimic the functional characteristics of natural teeth, and would likely improve implant duration and function. OBJECTIVES: The objective of this study was to investigate the feasibility of bioengineering PDL tissues onto titanium implant surfaces. METHODS: Bilateral maxillary first and second molars of 8-week old rats were extracted and used to generate single cell suspensions of PDL tissues, which were expanded in culture. Immunohistochemistry and RT-PCR were used to identify putative PDL progenitor/stem cell populations and characterize stem cell properties, including self-renewal, multipotency and stem cell maker expression. Cultured rPDL cells were harvested at third passage, seeded onto Matrigel-coated titanium implants (1.75 mm x 1 mm), and placed into healed M1/M2 extraction sites. Non-cell seeded Matrigel-coated titanium implants served as negative controls. Implants were harvested after 8, 12, or 18 weeks. RESULTS: Cultured rPDL cells expressed the mesenchymal stem-cell marker STRO-1. Under defined culture conditions, PDL cells differentiated into adipogenic, neurogenic and osteogenic lineages. While control implants were largely surrounded by alveolar bone, experimental samples exhibited fibrous PDL-like tissues, and perhaps cementum, on the surface of experimental implants. CONCLUSIONS: PDL contains stem cells that can generate cementum/PDL-like tissue in vivo. Transplantation of these cells might hold promise as a therapeutic approach for the bioengineering of PDL tissues onto titanium implant. Further refinement of this method will likely result in improved dental implant strategies for use of autologous PDL tissue regeneration in humans. This research was supported by CIMIT, and NIH/NIDCR grant DE016132 (PCY), and TEACRS (YL).
Resumo:
BACKGROUND: Although considerable bone fill may occur following treatment of peri-implantitis, re-osseointegration appears to be limited and unpredictable. Objectives: To evaluate the effects of various decontamination techniques and implant surface configurations on re-osseointegration of contaminated dental implants. MATERIAL AND METHODS: Three months after tooth extraction, implants consisting of a basal part and an exchangeable intraosseous implant cylinder (EIIC) were placed in the mandibles of dogs. The EIIC was machined (M), sandblasted and acid-etched (SLA), or titanium plasma sprayed (TPS). Ligature-induced peri-implantitis was initiated 8 weeks post-implantation and lasted until bone loss reached the junction of the two implant parts. Three treatment modalities were applied: (T1) the EIIC was exchanged for a pristine EIIC; (T2) the EIIC was sprayed in situ with saline; and (T3) the EIIC was removed, cleansed outside the mouth by spraying with saline, steam-sterilized, and remounted. A collagen barrier was placed over each fixture, and 3 months later, samples were processed for histology and histomorphometry. RESULTS: T2 revealed the highest bone-to-implant contact (BIC) level (significantly better than T1 and T3). T2 also yielded the highest bone crest level (significantly better than T1), followed by T3 (significantly better than T1). SLA showed the highest BIC level (significantly better than M), followed by TPS. There were no statistically significant differences in bone crest height between implant types. CONCLUSIONS: Both SLA implants and in situ cleansing resulted in the best re-osseointegration and bone fill of previously contaminated implants.
Resumo:
Proteins play an important role in the biological mechanisms controlling hard tissue development, but the details of molecular recognition at inorganic crystal interfaces remain poorly characterized. We have applied a recently developed homonuclear dipolar recoupling solid-state NMR technique, dipolar recoupling with a windowless sequence (DRAWS), to directly probe the conformation of an acidic peptide adsorbed to hydroxyapatite (HAP) crystals. The phosphorylated hexapeptide, DpSpSEEK (N6, where pS denotes phosphorylated serine), was derived from the N terminus of the salivary protein statherin. Constant-composition kinetic characterization demonstrated that, like the native statherin, this peptide inhibits the growth of HAP seed crystals when preadsorbed to the crystal surface. The DRAWS technique was used to measure the internuclear distance between two 13C labels at the carbonyl positions of the adjacent phosphoserine residues. Dipolar dephasing measured at short mixing times yielded a mean separation distance of 3.2 ± 0.1 Å. Data obtained by using longer mixing times suggest a broad distribution of conformations about this average distance. Using a more complex model with discrete α-helical and extended conformations did not yield a better fit to the data and was not consistent with chemical shift analysis. These results suggest that the peptide is predominantly in an extended conformation rather than an α-helical state on the HAP surface. Solid-state NMR approaches can thus be used to determine directly the conformation of biologically relevant peptides on HAP surfaces. A better understanding of peptide and protein conformation on biomineral surfaces may provide design principles useful for the modification of orthopedic and dental implants with coatings and biological growth factors that are designed to enhance biocompatibility with surrounding tissue.
Resumo:
This project aimed at understanding the molecular mechanisms involved in the superior integration of micro-roughened titanium implant surfaces with the surrounding bone, when compared with their smooth surfaces. It involved studying the role of microRNAs and cell signaling pathways in the molecular regulation of bone cells on topographically modified titanium dental implants. The findings suggest a highly regulated microRNA-mediated control of molecular mechanisms during the process of bone formation that may be responsible for the superior osseointegration properties on micro-roughened titanium implant surfaces and indicate the possibility of using microRNA modulators to enhance osseointegration in clinically demanding circumstances.
Resumo:
The genus Actinomyces consists of a heterogeneous group of gram-positive, mainly facultatively anaerobic or microaerobic rods showing various degrees of branching. In the oral cavity, streptococci and Actinomyces form a fundamental component of the indigenous microbiota, being among initial colonizers in polymicrobial biofilms. The significance of the genus Actinomyces is based on the capability of species to adhere to surfaces such as on teeth and to co-aggregate with other bacteria. Identification of Actinomyces species has mainly been based on only a few biochemical characteristics, such as pigmentation and catalase production, or on the use of a single commercial kit. The limited identification of oral Actinomyces isolates to species level has hampered knowledge of their role both in health and disease. In recent years, Actinomyces and related organisms have attracted the attention of clinical microbiologists because of a growing awareness of their presence in clinical specimens and their association with disease. This series of studies aimed to amplify the identification methods for Actinomyces species. With the newly developed identification scheme, the age-related occurrence of Actinomyces in healthy mouths of infants and their distribution in failed dental implants was investigated. Adhesion of Actinomyces species to titanium surfaces processed in various ways was studied in vitro. The results of phenotypic identification methods indicated a relatively low applicability of commercially available test kits for reliable identification within the genus Actinomyces. However, in the study of conventional phenotypic methods, it was possible to develop an identification scheme that resulted in accurate differentiation of Actinomyces and closely related species, using various different test methods. Genotypic methods based on 16S rRNA sequence analysis of Actinomyces proved to be a useful method for genus level identification and further clarified the species level identification with phenotypic methods. The results of the study of infants showed that the isolation frequency of salivary Actinomyces species increased according to age: thirty-one percent of the infants at 2 months but 97% at 2 years of age were positive for Actinomyces. A. odontolyticus was the most prominent Actinomyces colonizer during the study period followed in frequency by A. naeslundii and A. viscosus. In the study of explanted dental implants, Actinomyces was the most prevalent bacterial genus, colonizing 94% of the fixtures. Also in the implants A. odontolyticus was revealed as the most common Actinomyces species. It was present in 84% of Actinomyces -positive fixtures followed in frequency by A. naeslundii, A. viscosus and A. israelii. In an in vitro study of titanium surfaces, different Actinomyces species showed variation regarding their adhesion to titanium. Surface roughness as well as albumin coating of titanium had significant effects on adhesion. The use of improved phenotypic and molecular diagnostic methods increased the accuracy of the identification of the Actinomyces to species level. This facilitated an investigation of their occurrence and distribution in oral specimens in both health and disease.
Resumo:
Nanostructured metals are a promising class of biomaterials for application in orthopedics to improve the mechanical performance and biological response for increasing the life of biomedical implants. Surface mechanical attrition treatment (SMAT) is an efficient way of engineering nanocrystalline surfaces on metal substrates. In this work, 316L stainless steel (SS), a widely used orthopedic biomaterial, was subjected to SMAT to generate a nanocrystalline surface. Surface nanocrystallization modified the nature of the oxide layer present on the surface. It increased the corrosion-fatigue strength in saline by 50%. This increase in strength is attributed to a thicker oxide layer, residual compressive stresses, high strength of the surface layer, and lower propensity for intergranular corrosion in the nanocrystalline layer. Nanocrystallization also enhanced osteoblast attachment and proliferation. Intriguingly, wettability and surface roughness, the key parameters widely acknowledged for controlling the cellular response remained unchanged after nanocrystallization. The observed cellular behavior is explained in terms of the changes in electronic properties of the semiconducting passive oxide film present on the surface of 316L SS. Nanocrystallization increased the charge carrier density of the n-type oxide film likely preventing denaturation of the adsorbed cell-adhesive proteins such as fibronectin. In addition, a net positive charge developed on the otherwise neutral oxide layer, which is known to facilitate cellular adhesion. The role of changes in the electronic properties of the oxide films on metal substrates is thus highlighted in this work. This study demonstrates the advantages of nanocrystalline surface modification by SMAT for processing metallic biomaterials used in orthopedic implants.
Resumo:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária
Resumo:
This case report details the successful rehabilitation of an edentulous patient using a complete upper prosthesis and a lower implant retained overdenture. The provision of care was split between a specialist centre and a primary care setting. This approach reduced inconvenience to the patient. Modern surgical and prosthodontic techniques also reduced the total delivery time. After initial consultation a new set of complete dentures was prescribed with changes in design to the originals. The patient was also planned for placement of two mandibular implants to stabilise and retain the mandibular denture. The first line of treatment involved provision of a new set of dentures constructed by the patient's general dental practitioner. Dental implants were then placed in a specialist centre and the patient returned to the dental practice for attachment of the lower denture to the dental implants. The benefits and success of mandibular implant retained dentures are well documented. With delivery of the overdenture, the patient reported increased satisfaction with his prostheses which allowed him to eat a greater range of foods and enabled him to feel confident when speaking and socialising.
Resumo:
El objetivo de este trabajo es la elaboración de un plan de mercadeo para la empresa Nobel Biocare en el sector de estética dental. Para cumplir este objetivo se realizó un análisis de la situación actual de la empresa, específicamente en Bogotá, siendo la ciudad donde se maneja el 40% de su mercado. Para el presente análisis se evaluó la competencia, reconociendo sus ventajas y desventajas en el mercado. También se clasificaron los tipos de clientes y la importancia que estos tienen para la compañía. Se realizaron encuestas a los clientes de Nobel Biocare, por medio de las cuales se pudo concluir una positiva percepción de la compañía. Asimismo se analizaron las tres líneas de productos principales de Nobel Biocare diseñándose una estrategia para cada uno de estos y su posicionamiento en el mercado.