988 resultados para Dental Implant


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Commercially pure titanium alloys are currently used as metallic biomaterials in implantology. Corrosion phenomena appear to play a decisive role in metallic implant long-term behavior. Thus, the goal of this study was to examine the genotoxic potential of corrosion eluates obtained from dental implants using Chinese ovary hamster cells in vitro by the single-cell gel (comet) assay. This technique detects deoxyribonucleic acid strand breaks in individual cells in alkaline conditions.Materials and Methods: the materials tested included 3 dental implants commercially available. Each of the tested materials was corroded in a solution consisting of equal amounts of acetic acid and sodium chloride (0.1 M) for 1, 3, 7, 14, and 21 days. The Chinese ovary hamster cultures were then exposed to all corrosion eluates obtained from endosseous dental implants for 30 minutes at 37 degrees C.Results: None of the eluates was found to exhibit genotoxicity, regardless of the type of dental implant used.Conclusion: the results suggest that all dental implants tested in this study did not induce deoxyribonucleic acid breakage as depicted by the single-cell gel (comet) assay.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The uses of a new bone spreading technique with simultaneous implant placement are discussed. The spreading system is an alternative technique to Summers' osteotome. Specific screw designs (spreader) served to laterally compress the bone to increase the cancellous density adjacent to the site. The spreader achieved a controlled and standardized dilation of horizontal bone. The advantages, material selection, and the application of this new procedure are detailed. (Implant Dent 2009; 18:119-125)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Currently, there are several techniques for the rehabilitation of atrophic maxillary ridges in literature. The grafting procedure using autogenous bone is considered ideal by many researchers, as it shows osteogenic capability and causes no antigenic reaction. However, this type of bone graft has some shortcomings, mainly the restricted availability of donor sites. In recent years, several alternatives have been investigated to supply the disadvantages of autogenous bone grafts. In such studies, allogeneic bone grafts, which are obtained from individuals with different genetic load, but from the same species, have been extensively used. They can be indicated in cases of arthroplasty, surgical knee reconstruction, large bone defects, and in oral and maxillofacial reconstruction. Besides showing great applicability and biocompatibility, this type of bone is available in unlimited quantities. on the other hand, allogeneic bone may have the disadvantage of transmitting infectious diseases. Atrophic maxillae can be treated with bone grafts followed by osseointegrated implants to obtain aesthetic and functional oral rehabilitation. This study aimed to show the viability of allogeneic bone grafting in an atrophic maxilla, followed by oral rehabilitation with dental implant and protocol-type prosthesis within a 3-year follow-up period by means of a clinical case report.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To identify the trend of authorship in dental implant by exploring the prevalence of coauthored articles and to investigate the collaboration efforts, trends in funding involved in original articles, and their relationships. Materials: Articles published in the Clinical Oral Implants Research, International Journal of Oral & Maxillofacial Implants, Clinical Implant Dentistry and Related Research, Implant Dentistry, and Journal of Oral Implantology from 2005 to 2009 were reviewed. Nonoriginal articles were excluded. For each included articles, number of authors, collaboration efforts, and extramural funding were recorded. Descriptive and analytical statistics (alpha = 0.05), including logistic regression analysis and chi(2) test, were used. Results: From a total of 2085 articles, 1503 met the inclusion criteria. Publications with 5 or more authors increased over time (P = 0.813). The amount of collaboration among different disciplines, institutions, and countries all increased. The greatest increase of collaboration was seen among institutions (P = 0.09). Non-funding studies decreased over time (P = 0.031). There was a strong association between collaboration and funding for the manuscripts during the years studied (OR, 1.5). Conclusion: The number of authors per articles and collaborative studies increased over time in implant-related journals. Collaborative studies were more likely to be funded. (Implant Dent 2011;20:68-75)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigated the effect of an Argon-based atmospheric pressure plasma (APP) surface treatment operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: rough titanium surface (Ti) and rough titanium surface + Argon-based APP (Ti-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received two plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ti, C, and O for the Ti and Ti- Plasma surfaces. Both surfaces presented carbon primarily as hydrocarbon (C?C, C?H) with lower levels of oxidized carbon forms. The Ti-Plasma presented large increase in the Ti (+11%) and O (+16%) elements for the Ti- Plasma group along with a decrease of 23% in surface-adsorbed C content. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC (>300%) and mean BAFO (>30%) were observed for Ti-Plasma treated surfaces. From a morphologic standpoint, improved interaction between connective tissue was observed at 1 week, likely leading to more uniform and higher bone formation at 3 weeks for the Ti-Plasma treated implants was observed. (C) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A 2012.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)