966 resultados para DIODE-ARRAY DETECTION
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Cu(II)/neocuproine (2,9-dimethyl-1,10-phenanthroline) complexes were utilized for spectrophotometric determination of total polyphenol content in beers. This procedure is based on the reduction of Cu(II) by polyphenols in hydroethanolic medium (pH 7.0) in the presence of neocuproine, yielding Cu(I)/complexes with maximum absorption at 454 nm. The sensitivity of the proposed method was compared with the AOAC method using tannic and gallic acid as standards. The average apparent molar absorptivity, in L cm(-1) mol(-1), of tannic acid (3.50 +/- 0.20) x 10(5) and gallic acid (5.12 +/- 0.21) x 10(4), was twice as high for the proposed method. A lower limit of detection (LOD) (2.9 x 10(-1) mg L-1) was found when tannic acid was used in the proposed method. Additionally, less interference from the most common additives in beers was noticed. Total content of polyphenols was analyzed in 17 Brazilian samples. Results ranged from 35.5 to 556 mg L-1 of tannic acid, with higher values for recovery rates (45.4-118%, mean 85.0%) than for gallic acid. Although tannic acid is a mixture of polygalloyl glucoses, the total polyphenol content found in the samples suggests that tannic acid should be used as a standard. This is the first attempt to use this particular copper complex to quantify total polyphenol content in beer samples. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
Styrax camporum Pohl, known in Brazil as estoraque do campo or cuia de brejo, has been used in the treatment of gastrointestinal diseases. The therapeutic action of S. camporum has been attributed to the ethyl acetate fraction, although the chemical composition of this fraction has not yet been analyzed. In this study, a high-performance liquid chromatography photodiode array detection (HPLC-PAD) method for analysis of Brazilian Styrax species has been developed. The compounds egonol (1) and homoegonol (2) were found to be present in all the samples investigated by HPLC. These compounds were isolated by open column chromatography followed by preparative TLC, and were identified by 1H NMR. Compounds 1 and 2 were thus proposed as phytochemical markers for Styrax, owing to their biological properties and presence in other Styrax species. The developed method has been validated and successfully applied for quantification of 1 and 2 in S. camporum dried leaves and crude ethanolic extracts from S. ferrugineus and S. pohlii aerial parts. Copyright (c) 2011 John Wiley & Sons, Ltd.
Resumo:
A fast and sensitive method for the simultaneous determination of Sudan dyes (I, II, III, and IV) in food samples was developed for the first time using partial filling micellar electrokinectic chromatography-mass spectrometry (MEKC-MS). The use of MEKC was essential to achieve the separation of these neutral analytes, while the partial filling technique was necessary to avoid the contamination of the ion source with non-volatile micelles. MEKC separation and MS detection conditions were optimized in order to achieve a fast, efficient, and sensitive separation of the four dyes. Filling 25% of the capillary with an MEKC solution containing 40 mM ammonium bicarbonate, 25 mM SDS, and 32.5% (v/v) acetonitrile, a baseline separation of the four azo-dyes was obtained in 10 min. Tandem MS was investigated in order to improve the sensitivity and selectivity of the analysis. Limits of detection (LOD) values 5, 8, 15, and 29 times better were obtained for Sudan III, I, II, and IV, respectively, using partial filling MEKC-MS/MS instead of partial filling MEKC-MS. Under optimized conditions, LOD from 0.05 to 0.2 mu g/mL were obtained. The suitability of the developed method was demonstrated through the fast and sensitive determination of Sudan I, II, III, and IV in spiked chilli powder samples. This determination could not be achieved by MEKC-UV due to the existence of several interfering compounds from the matrix.
Resumo:
Drug abuse is a major global problem which has a strong impact not only on the single individual but also on the entire society. Among the different strategies that can be used to address this issue an important role is played by identification of abusers and proper medical treatment. This kind of therapy should be carefully monitored in order to discourage improper use of the medication and to tailor the dose according to the specific needs of the patient. Hence, reliable analytical methods are needed to reveal drug intake and to support physicians in the pharmacological management of drug dependence. In the present Ph.D. thesis original analytical methods for the determination of drugs with a potential for abuse and of substances used in the pharmacological treatment of drug addiction are presented. In particular, the work has been focused on the analysis of ketamine, naloxone and long-acting opioids (buprenorphine and methadone), oxycodone, disulfiram and bupropion in human plasma and in dried blood spots. The developed methods are based on the use of high performance liquid chromatography (HPLC) coupled to various kinds of detectors (mass spectrometer, coulometric detector, diode array detector). For biological sample pre-treatment different techniques have been exploited, namely solid phase extraction and microextraction by packed sorbent. All the presented methods have been validated according to official guidelines with good results and some of these have been successfully applied to the therapeutic drug monitoring of patients under treatment for drug abuse.
Resumo:
An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN).
Resumo:
To ensure the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical institutions, and many devices and action levels are used. Since the acceptance criteria determines if the dosimetric tools’ output passes the patient plan, it is important to see how these parameters influence the performance of the QA device. While analyzing the results of IMRT QA, it is important to understand the variability in the measurements. Due to the different form factors of the many QA methods, this reproducibility can be device dependent. These questions of patient-specific IMRT QA reproducibility and performance were investigated across five dosimeter systems: a helical diode array, radiographic film, ion chamber, diode array (AP field-by-field, AP composite, and rotational composite), and an in-house designed multiple ion chamber phantom. The reproducibility was gauged for each device by comparing the coefficients of variation (CV) across six patient plans. The performance of each device was determined by comparing each one’s ability to accurately label a plan as acceptable or unacceptable compared to a gold standard. All methods demonstrated a CV of less than 4%. Film proved to have the highest variability in QA measurement, likely due to the high level of user involvement in the readout and analysis. This is further shown by how the setup contributed more variation than the readout and analysis for all of the methods, except film. When evaluated for ability to correctly label acceptable and unacceptable plans, two distinct performance groups emerged with the helical diode array, AP composite diode array, film, and ion chamber in the better group; and the rotational composite and AP field-by-field diode array in the poorer group. Additionally, optimal threshold cutoffs were determined for each of the dosimetry systems. These findings, combined with practical considerations for factors such as labor and cost, can aid a clinic in its choice of an effective and safe patient-specific IMRT QA implementation.
Resumo:
The purpose of this work was to compare and optimise different selective and differential media to aid in isolating spoilage yeasts belonging to the Brettanomyces/Dekkera genera. Growth media containing selective and differential factors were employed. These were inoculated with strains of yeast representing Spanish oenological microbiota. Lastly, some of these isolation media were successfully applied in 24 types of wine with a high ethylphenol content, all of which were from the Haro Oenological Station (La Rioja, Spain). p-coumaric acid was determined using High performance liquid chromatography-photodiode-array detection-electrospray ionization mass spectrometry (HPLC-DAD-ESI/MS); 4-ethylphenol by using Solid phase micro extraction-gas chromatography-mass spectrometry (SPME-GC-MS); and the rest of the analysis was carried out using official OIV methodology. Actidione is the most effective selective factor for isolating Brettanomyces/Dekkera yeast genera. Other secondary selective factors (selective carbon sources, sorbic acid and ethanol as a microbicide agent) may be used successfully to eliminate potential false positivities; however, they slow growth and delay the time to obtain results.
Resumo:
In this manuscript, a study of the effect of microwave radiation on the high-performance liquid chromatography separation of tocopherols and vitamin K1 was conducted. The novelty of the application was the use of a relatively low polarity mobile phase in which the dielectric heating effect was minimized to evaluate the nonthermal effect of the microwave radiation over the separation process. Results obtained show that microwave-assisted high-performance liquid chromatography had a shorter analysis time from 31.5 to 13.3 min when the lowest microwave power was used. Moreover, narrower peaks were obtained; hence the separation was more efficient maintaining or even increasing the resolution between the peaks. This result confirms that the increase in mobile phase temperature is not the only variable for improving the separation process but also other nonthermal processes must intervene. Fluorescence detection demonstrated better signal-to-noise compared to photodiode arrayed detection mainly due to the independent effect of microwave pulses on the baseline noise, but photodiode array detection was finally chosen as it allowed a simultaneous detection of nonfluorescent compounds. Finally, a determination of the content of the vitamin E homologs was carried out in different vegetable oils. Results were coherent with those found in the literature.
Resumo:
As part of a 4-year project to study phenolic compounds in tea shoots over the growing seasons and during black tea processing in Australia, an HPLC method was developed and optimised for the identification and quantification of phenolic compounds, mainly flavanols and phenolic acids, in fresh tea shoots. Methanol proved to be the most suitable solvent for extracting the phenolic compounds, compared with chloroform, ethyl acetate and water. Immediate analysis, by HPLC, of the methanol extract showed higher separation efficiency than analyses after being dried and redissolved. This method exhibited good repeatability (CV 3-9%) and recovery rate (88-116%). Epigallocatechin gallate alone constituted up to 115 mg/g, on a dry basis, in the single sample of Australian fresh tea shoots examined. Four catechins (catechin, gallocatechin, epicatechin and epigallocatechin) and six catechin gallates (epigallocatechin gallate, catechin gallate, epicatechin gallate, gallocatechin gallate, epicatechin digallate and epigallocatechin digallate) have been identified and quantified by this HPLC method. In addition, two major tea alkaloids, caffeine and theobromine, have been quantified, while five flavonol glycosides and six phenolic acids, including quinic acids and esters, were identified and quantified. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Vaccinium myrtillus or bilberry fruit is a commonly used herbal product. The usual method of determining the anthocyanin content is a single-wavelength spectrophotometric assay. Using this method, anthocyanin levels of two extracts were found to be 25% as claimed by the manufacturers. When high-performance liquid chromatography (HPLC) was used, however, one extract was found to contain 9% anthocyanins probably not derived from V. myrtillus but from an adulterant. This adulterant was subsequently identified, using HPLC, mass spectroscopy, and nuclear magnetic resonance, as amaranth, that is, 3-hydroxy-4-[(4-sulfo-1-naphthalenyl)azo]-2,7-naphthalenedisulfonic acid trisodium saltsa synthetic dark red sulfonic acid based naphthylazo dye. As described in this study, if deliberate adulteration occurs in an extract, a single-wavelength spectrophotometric assay is inadequate to accurately determine the levels of compounds such as anthocyanins. Detection of deliberate adulteration in commercial samples thus requires the use of alternative, more sophisticated, methods of analysis such as HPLC with photodiode array detection as a minimum.
Resumo:
Hancornia speciosa Gomes (Apocynaceae), popularly known as ‘mangabeira’, has been used in folk medicine to treat inflammatory disorders, hypertension, dermatitis, diabetes, liver diseases and stomach disorders. Regarding the Hancornia speciosa fruits, the ethnobotany indicates its use especially for treating inflammation and tuberculosis. However, no study has been done so far to prove such biological activities. The objective was evaluation anti-inflammatory activity from the fruits of Hancornia speciosa Gomes (mangabeira). Aqueous extract was prepared by decoction, subsequently submitted the liquid-liquid fractionation. The secondary metabolites were identified by high performance liquid chromatography coupled with detector diode array (HPLC-DAD) and liquid chromatography diode array detector coupled with mass spectrometry (LC-DAD-MS). The anti-inflammatory properties of the aqueous extract, dichloromethane (CH2Cl2), ethyl acetate (EtOAc) and n-butanol (n-BuOH) fractions of the fruits from H. speciosa, as well as rutin and chlorogenic acid were investigated using in vitro and in vivo models. In vivo tests comprised the xylene-induced ear edema that was measured the formation of edema, carrageenan-induced peritonitis was evaluated the total leukocytes at 4h and zymosan-induced air pouch was measured the total leukocytes and differential cell count at 6, 24 and 48 hours, whereas in vitro tests were evaluated levels of cytokines IL-1β, IL-6, IL-12 and TNF-α using ELISA obtained of carrageenan-induced peritonitis model. The results showed the presence of rutin and chlorogenic acid were detected in the aqueous extract from H. speciosa fruits by HPLC-DAD and LC-DAD-ME. Furthermore, the aqueous extracts and fractions, as well as rutin and chlorogenic acid significantly inhibited the xilol-induced ear edema and reduced cell migration in the animal models such as carrageenan-induced peritonitis and zymosan-induced air pouch. In addition, reduced levels of cytokines IL-1β, IL-6, IL-12 and TNF-α were observed. This is the first study that demonstrated the anti-inflammatory effect of aqueous extract from Hancornia speciosa fruits against different inflammatory agents in animal models, suggesting that their bioactive molecules, especially rutin and chlorogenic acid contributing, at least in part, to the anti-inflammatory effect of aqueous extract. These findings support the widespread use of Hancornia speciosa in popular medicine and demonstrate that this aqueous extract has therapeutic potential for the development of a herbal drugs with anti-inflammatory properties.
Resumo:
We quantified pigment biomarkers by high performance liquid chromatography (HPLC) to obtain a broad taxonomic classification of microphytobenthos (MPB) (i.e. identification of dominant taxa). Three replicate sediment cores were collected at 0, 50 and 100 m along transects 5-9 in Heron Reef lagoon (n=15) (Fig. 1). Transects 1-4 could not be processed because the means to have the samples analysed by HPLC were not available at the time of field data collection. Cores were stored frozen and scrapes taken from the top of each one and placed in cryovials immersed in dry ice. Samples were sent to the laboratory (CSIRO Marine and Atmospheric Research, Hobart, Australia) where pigments were extracted with 100% acetone during fifteen hours at 4°C after vortex mixing (30 seconds) and sonication (15 minutes). Samples were then centrifuged and filtered prior to the analysis of pigment composition with a Waters - Alliance HPLC system equipped with a photo-diode array detector. Pigments were separated using a Zorbax Eclipse XDB-C8 stainless steel 150 mm x 4.6 mm ID column with 3.5 µm particle size (Agilent Technologies) and a binary gradient system with an elevated column temperature following a modified version of the Van Heukelem and Thomas (2001) method. The separated pigments were detected at 436 nm and identified against standard spectra using Waters Empower software. Standards for HPLC system calibration were obtained from Sigma (USA) and DHI (Denmark).