440 resultados para DENTURES
Resumo:
STATEMENT OF PROBLEM: Wear of methacrylate artificial teeth resulting in vertical loss is a problem for both dentists and patients. PURPOSE: The purpose of this study was to quantify wear of artificial teeth in vivo and to relate it to subject and tooth variables. MATERIAL AND METHODS: Twenty-eight subjects treated with complete dentures received 2 artificial tooth materials (polymethyl methacrylate (PMMA)/double-cross linked PMMA fillers; 35%/59% (SR Antaris DCL, SR Postaris DCL); experimental 48%/46%). At baseline and after 12 months, impressions of the dentures were poured with improved stone. After laser scanning, the casts were superimposed and matched. Maximal vertical loss (mm) and volumetric loss (mm(3)) were calculated for each tooth and log-transformed to reduce variability. Volumetric loss was related to the occlusally active surface area. Linear mixed models were used to study the influence of the factors jaw, tooth, and material on adjusted (residual) wear values (alpha=.05). RESULTS: Due to drop outs (n=5) and unmatchable casts (n=3), 69% of all teeth were analyzed. Volumetric loss had a strong linear relationship to surface area (P<.001); this was less pronounced for vertical loss (P=.004). The factor showing the highest influence was the subject. Wear was tooth dependent (increasing from incisors to molars). However, these differences diminished once the wear rates were adjusted for occlusal area, and only a few remained significant (anterior versus posterior maxillary teeth). Another influencing factor was the age of the subject. CONCLUSIONS: Clinical wear of artificial teeth is higher than previously measured or expected. The presented method of analyzing wear of artificial teeth using a laser-scanning device seemed suitable.
Resumo:
OBJECTIVE: When we examined a previously published prospective multi-center clinical trial in which complete denture-wearers were followed over a period of 2 years, we found that about 30% of the variability in the clinical wear data of denture teeth was due to unknown characteristics of the subjects. In the second part of the study, we try to identify which patient- and therapy-related factors may explain some of this variability. METHODS: The clinical wear data of denture teeth at different recall times (6, 12, 18, 24 months) in 89 subjects (at baseline) were correlated with the following parameters, which may all have an influence on the wear of denture teeth: age, gender, bruxism as reported by the subjects, number of prostheses used so far, time since last extraction, smoking, fit of dentures as judged by the subject and the clinician, average denture wearing time and wearing of denture during the night. To evaluate the influence of the different patient- and therapy-related variables, both a univariate analysis (one extra factor to the model) and a multivariate analysis were carried out using linear mixed models with the variable Log mean as the outcome. RESULTS: None of the patient- and therapy-related parameters showed a statistically significant effect on the wear of denture teeth. There was, however, a trend for women to show less wear compared to men and a trend of decreasing wear with increasing age. SIGNIFICANCE: Further research is required to identify the factors which are responsible for the high variability observed between the subjects regarding clinical wear data.
Resumo:
The aim of the study was to determine whether there is any relationship between the presence of removable dentures and squamous cell carcinoma of the anterior two thirds of the tongue in a Portuguese population. A retrospective cross-sectional study was conducted on patients with a biopsy-proven diagnosis of squamous cell carcinoma of the tongue, who were seen and treated at the Department of Head and Neck Surgery of the Portuguese Institute of Oncology 'Francisco Gentil', Lisbon, Portugal, during a 3-year period. Several factors were examined: gender, use of removable dentures, age, location of the lesion, and alcohol and tobacco consumption. One hundred and six cases were selected from the initial 151 cases, with a male:female ratio of 3:1 and the lateral borders being the most commonly affected site. The prevalence in both genders was between the sixth and seventh decade of life. Men were more likely to consume alcohol and tobacco than women, and no relationship was observed between denture use and presence of carcinoma of the tongue. In light of the data obtained, it may be considered that female use of a denture plays an important role, but it cannot be identified as a remarkable etiologic factor.
Resumo:
OBJECTIVE: (1) To quantify wear of two different denture tooth materials in vivo with two study designs, (2) to relate tooth variables to vertical loss. METHODS: Two different denture tooth materials had been used (experimental material=test; DCL=control). In study 1 (split-mouth, 6 test centers) 60 subjects received complete dentures, in study 2 (two-arm, 1 test center) 29 subjects. In study 1 the mandibular dentures were supported by implants in 33% of the subjects, in study 2 only in 3% of the subjects. Impressions of the dentures were taken and poured with improved stone at baseline and after 6, 12, 18 and 24 months. Each operator evaluated the wear subjectively. Wear analysis was carried out with a laser scanning device. Maximal vertical loss of the attrition zones was calculated for each tooth cusp and tooth. A mixed linear model was used to statistically analyse the logarithmically transformed wear data. RESULTS: Due to drop-outs and unmatchable casts, only 47 subjects of study 1 and 14 of study 2 completed the 2-year recall. Overall, 75% of all teeth present could be analysed. There was no statistically difference in the overall wear between the test and control material for either study 1 or study 2. The relative increase in wear over time was similar in both study designs. However, a strong subject effect and center effect were observed. The fixed factors included in the model (time, tooth, center, etc.) accounted for 43% of the variability, whereas the random subject effect accounted for another 30% of the variability, leaving about 28% of unexplained variability. More wear was consistently recorded in the maxillary teeth compared to the mandibular teeth and in the first molar teeth compared to the premolar teeth and the second molars. Likewise, the supporting cusps showed more wear than the non-supporting cusps. The amount of wear did not depend on whether or not the lower dentures were supported by implants. The subjective wear was correct in about 67% of the cases if it is postulated that a wear difference of 100μm should be subjectively detectable. SIGNIFICANCE: The clinical wear of denture teeth is highly variable with a strong patient effect. More wear can be expected in maxillary denture teeth compared to mandibular teeth, first molars compared to premolars and supported cusps compared to non-supported cusps. Laboratory data on the wear of denture tooth materials may not be confirmed in well-structured clinical trials probably due to the large inter-individual variability.
Resumo:
Purpose: The aim of this review was to systematically evaluate and compare the frequency of veneer chipping and core fracture of zirconia fixed dental prostheses (FOPS) and porcelain-fused-to-metal (PFM) FDPs and determine possible influencing factors. Materials and Methods: The SCOPUS database and International Association of Dental Research abstracts were searched for clinical studies involving zirconia and PFM FDPs. Furthermore, studies that were integrated into systematic reviews on PFM FDPs were also evaluated. The principle investigators of any clinical studies on zirconia FDPs were contacted to provide additional information. Based on the available information for each FOP, a data file was constructed. Veneer chipping was divided into three grades (grade 1 = polishing, grade 2 = repair, grade 3 = replacement). To assess the frequency of veneer chipping and possible influencing factors, a piecewise exponential model was used to adjust for a study effect. Results: None of the studies on PFM FDPs (reviews and additional searching) sufficiently satisfied the criteria of this review to be included. Thirteen clinical studies on zirconia FDPs and two studies that investigated both zirconia and PFM FDPs were identified. These studies involved 664 zirconia and 134 PFM FDPs at baseline. Follow-up data were available for 595 zirconia and 127 PFM FDPs. The mean observation period was approximately 3 years for both groups. The frequency of core fracture was less than 1% in the zirconia group and 0% in the PFM group. When all studies were included, 142 veneer chippings were recorded for zirconia FDPs (24%) and 43 for PFM FDPs (34%). However, the studies differed extensively with regard to veneer chipping of zirconia: 85% of all chippings occurred in 4 studies, and 43% of all chippings included zirconia FDPs. If only studies that evaluated both types of core materials were included, the frequency of chipping was 54% for the zirconia-supported FDPs and 34% for PFM FDPs. When adjusting the survival rate for the study effect, the difference between zirconia and PFM FDPs was statistically significant for all grades of chippings (P = .001), as well as for chipping grade 3 (P = .02). If all grades of veneer chippings were taken into account, the survival of PFM FDPs was 97%, while the survival rate of the zirconia FDPs was 90% after 3 years for a typical study. For both PFM and zirconia FDPs, the frequency of grades 1 and 2 veneer chippings was considerably higher than grade 3. Veneer chipping was significantly less frequent in pressed materials than in hand-layered materials, both for zirconia and PFM FDPs (P = .04). Conclusions: Since the frequency of veneer chipping was significantly higher in the zirconia FDPs than PFM FDPs, and as refined processing procedures have started to yield better results in the laboratory, new clinical studies with these new procedures must confirm whether the frequency of veneer chipping can be reduced to the level of PFM. Int J Prosthodont 2010;23:493-502
Resumo:
AIMS: There is no standard test to determine the fatigue resistance of denture teeth. With the increasing number of patients with implant-retained dentures the mechanical strength of the denture teeth requires more attention and valid laboratory test set-ups. The purpose of the present study was to determine the fatigue resistance of various denture teeth using a dynamic load testing machine. METHODS: Four denture teeth were used: Bonartic II (Candulor), Physiodens (Vita), SR Phonares II (Ivoclar Vivadent) and Trubyte (Dentsply). For dynamic load testing, first upper molars with a similar shape and cusp inclination were selected. The molar teeth were embedded in cylindrical steel molds with denture base material (ProBase, Ivoclar Vivadent). Dynamic fatigue loading was carried out on the mesio-buccal cusp at a 45° angle using dynamic testing machines and 2,000,000 cycles at 2Hz in water (37°C). Three specimens per group and load were submitted to decreasing load levels (at least 4) until all the three specimens no longer showed any failures. All the specimens were evaluated under a stereo microscope (20× magnification). The number of cycles reached before observing a failure, and its dependence on the load and on the material, has been modeled using a parametric survival regression model with a lognormal distribution. This allowed to estimate the fatigue resistance for a given material as the maximal load for which one would observe less than 1% failure after 2,000,000 cycles. RESULTS: The failure pattern was similar for all denture teeth, showing a large chipping of the loaded mesio-buccal cusp. In our regression model, there were statistically significant differences among the different materials, with SR Phonares II and Bonartic II showing a higher resistance than Physiodens and Trubyte, the fatigue resistance being estimated at around 110N for the former two, and at about 60N for the latter two materials. CONCLUSION: The fatigue resistance may be a useful parameter to assess and to compare the clinical risk of chipping and fracture of denture tooth materials.
Resumo:
Dilutions of methylmetacrylate ranging between 1 and 50 ppm were obtained from a stock solution of 1 ml of monomer in 100 ml of deionised water, and were analyzed by an absorption spectrophotometer in the UV-visible. Absorbance values were used to develop a calibration model based on the PLS, with the aim to determine new sample concentrations. The number of latent variables used was 6, with the standard errors of calibration and prediction found to be 0,048 ml/100 ml and 0,058 ml/100 ml. The calibration model was successfully used to calculate the concentration of monomer released in water, where complete dentures were kept for one hour after polymerization.
Resumo:
The development of load-bearing osseous implant with desired mechanical and surface properties in order to promote incorporation with bone and to eliminate risk of bone resorption and implant failure is a very challenging task. Bone formation and resoption processes depend on the mechanical environment. Certain stress/strain conditions are required to promote new bone growth and to prevent bone mass loss. Conventional metallic implants with high stiffness carry most of the load and the surrounding bone becomes virtually unloaded and inactive. Fibre-reinforced composites offer an interesting alternative to metallic implants, because their mechanical properties can be tailored to be equal to those of bone, by the careful selection of matrix polymer, type of fibres, fibre volume fraction, orientation and length. Successful load transfer at bone-implant interface requires proper fixation between the bone and implant. One promising method to promote fixation is to prepare implants with porous surface. Bone ingrowth into porous surface structure stabilises the system and improves clinical success of the implant. The experimental part of this work was focused on polymethyl methacrylate (PMMA) -based composites with dense load-bearing core and porous surface. Three-dimensionally randomly orientated chopped glass fibres were used to reinforce the composite. A method to fabricate those composites was developed by a solvent treatment technique and some characterisations concerning the functionality of the surface structure were made in vitro and in vivo. Scanning electron microscope observations revealed that the pore size and interconnective porous architecture of the surface layer of the fibre-reinforced composite (FRC) could be optimal for bone ingrowth. Microhardness measurements showed that the solvent treatment did not have an effect on the mechanical properties of the load-bearing core. A push-out test, using dental stone as a bone model material, revealed that short glass fibre-reinforced porous surface layer is strong enough to carry load. Unreacted monomers can cause the chemical necrosis of the tissue, but the levels of leachable resisidual monomers were considerably lower than those found in chemically cured fibre-reinforced dentures and in modified acrylic bone cements. Animal experiments proved that surface porous FRC implant can enhance fixation between bone and FRC. New bone ingrowth into the pores was detected and strong interlocking between bone and the implant was achieved.
Resumo:
The purpose of this investigation was to evaluate the possibility to enhance certain qualities of facial prostheses. Polymethyl methacrylate is still being used as base mate¬rial or clip carrier material, but it is hard and heavy, and debonding of the silicone from the acrylic base material is a frequent problem. This thesis aims to evaluate the use of fiber-reinforced composite (FRC) as framework material for maxillofacial silicone prostheses. FRC has been used as reinforcement in removable and fixed partial dentures since the 1990s. This material is lightweight and can be fabricated to compress the margins of the prosthesis slightly, to keep it tightly against the skin during jaw movements and facial expressions. Additionally, the use of a thermochromic pigment, colorless in room temperature and red in a cold environment, was studied in order to evaluate the possibility of using this color changing pigment in facial prostheses to mimic the color change of facial skin in cold weather. The tensile bond strength between pre-impregnated, unidirectional FRC and maxillofacial silicone elastomer was studied. Three different bonding agents or primers were compared. Bond strength was improved by one of the primers and by roughening the surface. The effect of a skin compressing glass fiber-reinforced composite framework on facial skin blood flow was studied by using a face mask, constructed with a compression pad corresponding to the outer margin of a glass fiber-reinforced framework beam of a facial prosthesis. The skin blood flow of ten healthy volunteers, aged 23-25 years, was measured during touch, light, and moderate compression of the skin, by using laser Doppler imaging technique. None of the compressions showed any marked effects on local skin blood flow. There were no significant differences between blood flow during compression and at baseline. Maxillofacial silicone elastomer was colored intrinsically with conventional color pigments: a control group containing only conventional pigments was compared to two test groups with 0.2 wt% and 0.6 wt% thermochromic pigment added. The color of the material was measured with a spectrophotometer in room temperature and after storage in a freezer. The color stability of the maxillofacial silicone elastomer colored with thermo¬chromic pigment was evaluated by artificial aging. The color dif¬ference of the L* (lightness) and a* values (redness), comparing color after the samples were stored at room temperature and in a freezer (-19°C), was statistically significant for both 0.2 wt% and 0.6 wt% thermo¬chromic pigment groups. The differences in the b* values (yellowness) were statistically significant for the 0.6 wt% group. Exposure to ultraviolet (UV) radiation led to visually noticeable and statistically signifi¬cant color changes (ΔE) in all color values in both test groups. The specimens containing thermochromic pigment were very sensitive to UV radiation. In conclusion, a framework of fiber-reinforced composite can successfully be bonded to maxillofacial silicone elastomer, and a framework beam, compressing the facial skin, did not remarkably alter the skin blood flow on healthy, young adults. The thermochromic pigment showed color change in maxillofacial silicone elastomer. However, artificial aging showed that it was too sensitive to UV radiation to be used, as such, in maxillofacial prostheses.
Resumo:
Au Canada, la proportion de la population âgée de 65 ans et plus a augmenté depuis 1980. Bien que la dénutrition ne soit pas inévitable avec le vieillissement, certains changements et facteurs physiopathologiques, environnementaux et psycho socio-économiques peuvent entraîner une détérioration des choix alimentaires et donc, de la qualité de vie des aînés [1]. Plusieurs études font le lien entre l’état nutritionnel et la morbidité ainsi qu’avec les capacités fonctionnelles [2]. Ces observations expliquent l'intérêt de la prévention et du traitement de la dénutrition afin d’optimiser la prise alimentaire et un meilleur état de santé de cette population. Objectifs :1) Explorer les barrières individuelles et socio-environnementales, réelles et perçues, qui peuvent mener à la détérioration des choix et de la qualité alimentaires et entraîner une dénutrition chez les personnes âgées vivant à domicile. 2) Examiner la distribution de ces facteurs dans la population à l’étude. 3) Étudier la relation entre ces facteurs afin de dresser un portrait plus éclairé des déterminants négatifs de l’alimentation chez les adultes âgés pour mieux comprendre les barrières à la prise alimentaire saine. Méthodologie : Il s'agit d'une analyse secondaire réalisée à partir des données recueillies auprès des participants (n=1 602), âgés entre 67 et 84 ans,de l’Étude longitudinale québécoise sur la nutrition et le vieillissement réussi (NuAge) débutée en 2003 et dont le suivi était prévu sur cinq ans [3]. Le but principal de NuAge était de déterminer le rôle de la nutrition dans l’accomplissement d’un vieillissement réussi. Les données comprennent des mesures socio-démographiques, nutritionnelles, fonctionnelles, sociales de même que biologiques et médicales. À partir d'un modèle théorique des déterminants de la prise alimentaire chez la population âgée, ces données ont été mises en lien avec la qualité alimentaire. Cette dernière a été déterminée selon l’adaptation canadienne de l’indice d’alimentation saine (C-HEI), calculé à partir des données alimentaires et nutritionnelles obtenues par le questionnaire de fréquence alimentaire administré aux participants au T1, soit à leur entrée dans l'étude. Résultats : Les barrières qui pourraient freiner la qualité alimentaire des femmes incluent un statut affectif fragile et un fonctionnement social limité. Ce qui ressort, comme étant des barrières au C-HEI chez les hommes, est un revenu perçu comme étant insuffisant pour satisfaire les besoins, le port de prothèses dentaires et le fait de manger souvent au restaurant. Étonnamment, le nombre d’attitudes positives relatives à l’alimentation et un score plus élevé de la composante mentale du SF-36 prédisent un C-HEI plus faible. La nature des réponses auto rapportées pourrait expliquer ces résultats. Conclusion : Les résultats de cette recherche permettent de mieux comprendre les barrières d’une saine alimentation au sein d’une population bien-portante. Il est souhaité que les résultats contribueront au développement d’interventions efficaces ciblant les personnes âgées pour favoriser un apport nutritionnel et un état de santé optimal.
Resumo:
Problématique : La satisfaction des patients et la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) sont deux mesures de résultats fréquemment utilisées durant les études cliniques. Néanmoins, chez les patients totalement édentés, les évidences scientifiques relatives au niveau de relation entre ces deux mesures sont faibles. De plus, on ignore toujours quels éléments de la satisfaction des patients relativement à leurs prothèses partagent la meilleure relation avec la OHRQoL. Objectifs : Déterminer, chez les patients totalement édentés, s’il existe un lien entre leur satisfaction de leurs prothèses et leur OHRQoL et identifier les déterminants de satisfaction qui démontrent le meilleur niveau de relation avec la OHRQoL. Méthodologie : Les données provenant de 255 patients totalement édentés qui ont participé à une étude randomisée et contrôlée ont été utilisées. La OHRQoL a été évaluée à l’aide du questionnaire Oral Health Impact Profile (OHIP-20). Le McGill Denture Satisfaction Instrument a été utilisé pour estimer la satisfaction des patients. Ces mesures ont été prises au temps initial, à 6 mois et à 12 mois suivants la mise en bouche des prothèses. Des analyses statistiques de régression linéaire simples et multiples ont été utilisées afin d’évaluer la relation entre les deux mesures. Résultats : Une relation positive et considérable existe entre la satisfaction des patients totalement édentés et leur OHRQoL. La difficulté masticatoire (P = .005) et la condition buccale (P = .002) sont les éléments de la satisfaction qui possèdent le meilleur lien avec la OHRQoL. Ces deux facteurs expliquent 46.4% (P = .0001) de la variance dans l’amélioration d’OHIP suivant un traitement prosthodontique. La relation décrite est dépendante du temps, mais pas du type de traitement ni des variables sociodémographiques. Conclusions : Dans les limites de l’étude, il est conclu qu’une relation positive existe entre la satisfaction des patients et leur OHRQoL. La difficulté masticatoire et la condition buccale sont les deux éléments de la satisfaction les plus importants.
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
Introduction: La stomatite prothétique est une condition inflammatoire chronique de la muqueuse buccale recouverte par une prothèse. Cette maladie est considérée comme la lésion buccale la plus fréquente chez les porteurs de prothèses amovibles. Des études récentes sur l'étiologie de la stomatite prothétique suggèrent que des traitements basés sur la réduction de l'inflammation seraient efficaces dans le traitement de cette maladie. Objectifs: Évaluer l'efficacité du brossage du palais dans le traitement de la stomatite prothétique. Méthodes: Quarante-huit participants (âge moyen : 66,0 ± 11,2 ans) avec un diagnostic de stomatite prothétique, ont été sélectionnés à partir d’un examen préalable de 143 individus, afin de participer à cet essai clinique de phase I à deux centres, réalisé selon un devis de type pré-test/post-test à un seul groupe. L'intervention a consisté en un brossage du palais avec une brosse manuelle après chaque repas et avant le coucher. Des examens cliniques et microbiologiques ont été effectués avant le traitement, et à 1 mois et 3 mois de suivi. Des données supplémentaires ont été obtenues par l'utilisation d'un questionnaire validé. Les résultats primaires et secondaires étaient, respectivement, la rémission de stomatite prothétique et la diminution du nombre de colonies de Candida. Des tests statistiques descriptifs et non paramétriques ont été menés pour analyser les données. Résultats: À 3 mois de suivi, 10,4 % des participants ont été guéris et 70,8 % ont eu une amélioration clinique de la stomatite prothétique grâce au brossage du palais. Une réduction statistiquement significative de la surface et de l’intensité de l’inflammation après 3 mois de brossage du palais a été démontrée (p < 0,0001). L’ampleur de l’effet a varié d’un effet modéré à important (0,34 à 0,54) selon la classification utilisée pour le diagnostique de la stomatite prothétique. De plus, le nombre de colonies de Candida, recueillies par sonication des prothèses et par échantillonnage du palais, a diminué de manière statistiquement significative après 3 mois de brossage (p ≤ 0,05). Conclusion: Les résultats de cette étude suggèrent que le brossage du palais est efficace comme traitement de la stomatite prothétique.
Resumo:
Problématique : L’édentement et les troubles du sommeil sont des affections chroniques fréquentes chez les personnes âgées et qui peuvent avoir des conséquences défavorables sur le bien-être de ces personnes, ainsi que sur leur qualité de vie. L’édentement pourrait perturber le sommeil par la modification de la structure crânio-faciale et des tissus mous environnants. Cependant, cette relation n'est pas suffisamment documenté. Objectifs : Le but de cette étude pilote était de préparer la mise en œuvre d’une étude clinique randomisée contrôlée concernant l’effet du port nocturne des prothèses complètes sur la qualité du sommeil. Méthodologie : Treize aînés édentés ont participé à cette étude clinique randomisée contrôlée de type croisé. L’intervention consistait à dormir avec ou sans les prothèses durant la nuit. Les participants à l'étude ont été assignés à porter et ne pas porter leurs prothèses dans des ordres alternatifs pour des périodes de 30 jours. La qualité du sommeil a été évaluée par la polysomnographie portable et le questionnaire Pittburgh Sleep Quality Index (PSQI). Les données supplémentaires incluent la somnolence diurne, évaluée par le questionnaire Epworth Sleepiness Scale (ESS), et la qualité de vie liée à la santé buccodentaire, évaluée par le questionnaire Oral Health Impact Profile 20 (OHIP-20). De plus, à travers les examens cliniques et radiologiques, les données des caractéristiques sociodémographiques, de la morphologie oropharyngée, des caractéristiques buccodentaires et des prothèses ont été recueillies. Les modèles de régression linéaire pour les mesures répétées ont été utilisés pour analyser les résultats. Résultats : L’étude de faisabilité a atteint un taux de recrutement à l’étude de 59,1% et un taux de suivi de 100%. Le port nocturne des prothèses dentaires augmentait l’index d'apnée-hypopnée (IAH) et le score PSQI par rapport au non port nocturne des prothèses : (IAH : Médiane = 20,9 (1,3 - 84,7) versus 11,2 (1,9 - 69,6), p = 0,237; le score PSQI : Médiane = 6,0 (3,0 - 11,0) versus 5,0 (1,0 - 11,0), p = 0,248). Cependant, ces différences n'étaient pas statistiquement significatives, sauf que pour le temps moyen d’apnée (plus long avec des prothèses) (p < 0,005) et le temps de ronflement relatif (moins élevé avec des prothèses) (p < 0,05). La somnolence diurne excessive et la qualité de vie liée à la santé buccodentaire étaient semblables pour les deux interventions (le score ESS : Médiane = 4,0 (3,0-10,0) versus 5,0 (2,0-10,0), p = 0,746; le score OHIP-20: Médiane = 31,0 (20,0-64,0) versus 27,0 (20,0-49,0), p = 0,670). L’impact néfaste du port nocturne des prothèses complètes sur le sommeil a été statistiquement significatif chez les personnes souffrant de l’apnée-hypopnée moyenne à sévère (p < 0,005). Conclusion : L’essai clinique pilote a montré que le port nocturne des prothèses complètes a un impact négatif sur la qualité du sommeil des gens âgés édentés, surtout chez les personnes avec l’apnée obstructive du sommeil modérée à sévère. Les résultats doivent être confirmés par l’étude clinique randomisée contrôlée de phase II.
Resumo:
L’objectiu d’aquest projecte és integrar a la plataforma Starviewer ( plataforma informàtica de processament i visualització d’imatges mèdiques creada fruit de la col•laboració del Laboratori de Gràfics i Imatge (GILab) de la Universitat de Girona i l’Institut de Diagnòstic per la Imatge (IDI) de l’hospital Dr. Josep Trueta de Girona) per donar suport al diagnòstic un entorn de suport a la inserció de pròtesis, que permeti automatitzar al màxim les operacions que actualment es realitzen de forma manual. Hem de tenir en compte que, tot i que, la imatge més usada pel radiòleg es la radiografia (Rx) també treballa amb tomografia computada (TAC). El TAC dona una visió 3D de l’organisme, mentre que la Rx és 2D