926 resultados para Control-flow


Relevância:

40.00% 40.00%

Publicador:

Resumo:

To determine how changes in lipids, liver enzymes, and inflammatory and glycemia markers intercorrelate during prolonged dietary intervention in obese participants with or without type 2 diabetes (T2D).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Chair of Transportation and Ware-housing at the University of Dortmund together with its industrial partner has developed and implemented a decentralized control system based on embedded technology and Internet standards. This innovative, highly flexible system uses autonomous software modules to control the flow of unit loads in real-time. The system is integrated into Chair’s test facility consisting of a wide range of conveying and sorting equipment. It is built for proof of concept purposes and will be used for further research in the fields of decentralized automation and embedded controls. This presentation describes the implementation of this decentralized control system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Today’s material flow systems for mass customization or dynamic productions are usually realized with manual transportation systems. However new concepts in the domain of material flow and device control like function-oriented modularization and intelligent multi-agent-systems offer the possibility to employ changeable and automated material flow systems in dynamic production structures. These systems need the ability to react on unplanned and unexpected events autonomously.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION The appearance of end-diastolic flow velocities (EDF) in the umbilical artery (UA), usually between 10 and 14 weeks of gestation, has been associated with the opening of the spiral arteries and consequently of the intervillous space. OBJECTIVES The aim of our study was to compare first trimester UA pulsatility index (PI) and EDF between women who developed preeclampsia (cases) and controls. METHODS Our database was searched for cases who had UA Doppler between 10-14 weeks. UA PI and EDF were compared between cases and two gestational age (GA) matched controls. RESULTS 15 cases with severe preeclampsia (PE) were matched to 30 controls. GA with negative EDF was lower than with positive EDF (12.1±0.79 vs. 12.8±0.34; p=0.001). UA PI in cases was higher than in controls, although not significant (cases: 2.18±0.6 vs. CONTROLS 1.92±0.48; p=0.12). However, comparing groups with negative EDF, the difference became significant (PI cases: 2.45±0.57 vs. PI controls: 1.94±0.56; p=0.038), while no difference was found comparing groups with positive EDF. CONCLUSION First trimester UA PI is significantly higher in women which will develop PE than in controls. Interestingly, the timing of screening for PE by UA Doppler seems to play an important issue.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Literature on agency problems arising between controlling and minority owners claim that separation of cash flow and control rights allows controllers to expropriate listed firms, and further that separation emerges when dual class shares or pyramiding corporate structures exist. Dual class share and pyramiding coexisted in listed companies of China until discriminated share reform was implemented in 2005. This paper presents a model of controller to expropriate behavior as well as empirical tests of expropriation via particular accounting items and pyramiding generated expropriation. Results show that expropriation is apparent for state controlled listed companies. While reforms have weakened the power to expropriate, separation remains and still generates expropriation. Size of expropriation is estimated to be 7 to 8 per cent of total asset at mean. If the "one share, one vote" principle were to be realized, asset inflation could be reduced by 13 percent.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In pressure irrigation-water distribution networks, pressure regulating devices for controlling the discharged flow rate by irrigation units are needed due to the variability of flow rate. In addition, applied water volume is used controlled operating the valve during a calculated time interval, and assuming constant flow rate. In general, a pressure regulating valve PRV is the commonly used pressure regulating device in a hydrant, which, also, executes the open and close function. A hydrant feeds several irrigation units, requiring a wide range in flow rate. In addition, some flow meters are also available, one as a component of the hydrant and the rest are placed downstream. Every land owner has one flow meter for each group of field plots downstream the hydrant. Its lecture could be used for refining the water balance but its accuracy must be taken into account. Ideal PRV performance would maintain a constant downstream pressure. However, the true performance depends on both upstream pressure and the discharged flow rate. The objective of this work is to asses the influence of the performance on the applied volume during the whole irrigation events in a year. The results of the study have been obtained introducing the flow rate into a PRV model. Variations on flow rate are simulated by taking into account the consequences of variations on climate conditions and also decisions in irrigation operation, such us duration and frequency application. The model comprises continuity, dynamic and energy equations of the components of the PRV.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Control of linear flow instabilities has been demonstrated to be an effective theoretical flow control methodology, capable of modifying transitional flows on canonical geometries such as the plane channel and the flat-plate boundary layer. Extending the well-developed theoretical flow control techniques to flows over or through complex geometries requires addressing the issue of efficient capturing of the leading members of the global eigenspectrum pertinent to such flows. The present contribution describes state-of-the-art modal global instability analysis methodologies recently developed in our group, based on matrix formation and time-stepping, respectively. The relative performance of these algorithms is assessed on the recovery of BiGlobal and TriGlobal eigenspectra in the spanwise periodic and the cubic lid-driven cavity, respectively; the adjoint eigenspectrum in the latter flow is recovered for the first time. For three-dimensional flows without any homogeneous spatial direction, the time-stepping methodology was found to outperform the matrix-forming approach and permit recovering the leading TriGlobal eigenmodes in an three-dimensional open cavity of aspect ratio L : D : W = 5 : 1 : 1; theoretical flow control of this configuration is underway.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Control of linear flow instabilities has been demonstrated to be an effective theoretical flow control methodology, capable of modifying transitional flow on canonical geometries such as the plane channel and the flat-plate boundary layer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The three-dimensional wall-bounded open cavity may be considered as a simplified geometry found in industrial applications such as leading gear or slotted flats on the airplane. Understanding the three-dimensional complex flow structure that surrounds this particular geometry is therefore of major industrial interest. At the light of the remarkable former investigations in this kind of flows, enough evidences suggest that the lateral walls have a great influence on the flow features and hence on their instability modes. Nevertheless, even though there is a large body of literature on cavity flows, most of them are based on the assumption that the flow is two-dimensional and spanwise-periodic. The flow over realistic open cavity should be considered. This thesis presents an investigation of three-dimensional wall-bounded open cavity with geometric ratio 6:2:1. To this aim, three-dimensional Direct Numerical Simulation (DNS) and global linear instability have been performed. Linear instability analysis reveals that the onset of the first instability in this open cavity is around Recr 1080. The three-dimensional shear layer mode with a complex structure is shown to be the most unstable mode. I t is noteworthy that the flow pattern of this high-frequency shear layer mode is similar to the observed unstable oscillations in supercritical unstable case. DNS of the cavity flow carried out at different Reynolds number from steady state until a nonlinear saturated state is obtained. The comparison of time histories of kinetic energy presents a clearly dominant energetic mode which shifts between low-frequency and highfrequency oscillation. A complete flow patterns from subcritical cases to supercritical case has been put in evidence. The flow structure at the supercritical case Re=1100 resembles typical wake-shedding instability oscillations with a lateral motion existed in the subcritical cases. Also, This flow pattern is similar to the observations in experiments. In order to validate the linear instability analysis results, the topology of the composite flow fields reconstructed by linear superposition of a three-dimensional base flow and its leading three-dimensional global eigenmodes has been studied. The instantaneous wall streamlines of those composited flows display distinguish influence region of each eigenmode. Attention has been focused on the leading high-frequency shear layer mode; the composite flow fields have been fully recognized with respect to the downstream wave shedding. The three-dimensional shear layer mode is shown to give rise to a typical wake-shedding instability with a lateral motions occurring downstream which is in good agreement with the experiment results. Moreover, the spanwise-periodic, open cavity with the same length to depth ratio has been also studied. The most unstable linear mode is different from the real three-dimensional cavity flow, because of the existence of the side walls. Structure sensitivity of the unstable global mode is analyzed in the flow control context. The adjoint-based sensitivity analysis has been employed to localized the receptivity region, where the flow is more sensible to momentum forcing and mass injection. Because of the non-normality of the linearized Navier-Stokes equations, the direct and adjoint field has a large spatial separation. The strongest sensitivity region is locate in the upstream lip of the three-dimensional cavity. This numerical finding is in agreement with experimental observations. Finally, a prototype of passive flow control strategy is applied.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Final report, January 1979.