983 resultados para Complex Programmable Logic Device (CPLD)
Resumo:
This article extends Defeasible Logic to deal with the contextual deliberation process of cognitive agents. First, we introduce meta-rules to reason with rules. Meta-rules are rules that have as a consequent rules for motivational components, such as obligations, intentions and desires. In other words, they include nested rules. Second, we introduce explicit preferences among rules. They deal with complex structures where nested rules can be involved.
Resumo:
Described in this article is a novel device that facilitates study of the cross-sectional anatomy of the human head. In designing our device, we aimed to protect sections of the head from the destructive action of handling during anatomy laboratory while also ensuring excellent visualization of the anatomic structures. We used an electric saw to create 15-mm sections of three cadaver heads in the three traditional anatomic planes and inserted each section into a thin, perforated display box made of transparent acrylic material. The thin display boxes with head sections are kept in anatomical order in a larger transparent acrylic storage box containing formaldehyde solution, which preserves the specimens but also permits direct observation of the structures and their anatomic relationships to each other. This box-within-box design allows students to easily view sections of a head in its anatomical position as well as to examine internal structures by manipulating individual display boxes without altering the integrity of the preparations. This methodology for demonstrating cross-section anatomy allows efficient use of cadaveric material and technician time while also giving learners the best possible handling and visualization of complex anatomic structures. Our approach to teaching cross-sectional anatomy of the head can be applied to any part of human body, and the value of our device design will only increase as more complicated understandings of cross-sectional anatomy are required by advances and proliferation of imaging technology. Anat Sci Educ 3: 141-143, 2010. (C) 2010 American Association of Anatomists.
Resumo:
One of the most difficult problems that face researchers experimenting with complex systems in real world applications is the Facility Layout Design Problem. It relies with the design and location of production lines, machinery and equipment, inventory storage and shipping facilities. In this work it is intended to address this problem through the use of Constraint Logic Programming (CLP) technology. The use of Genetic Algorithms (GA) as optimisation technique in CLP environment is also an issue addressed. The approach aims the implementation of genetic algorithm operators following the CLP paradigm.
Resumo:
The foot and the ankle are small structures commonly affected by disorders, and their complex anatomy represent significant diagnostic challenges. SPECT/CT Image fusion can provide missing anatomical and bone structure information to functional imaging, which is particularly useful to increase diagnosis certainty of bone pathology. However, due to SPECT acquisition duration, patient’s involuntary movements may lead to misalignment between SPECT and CT images. Patient motion can be reduced using a dedicated patient support. We aimed at designing an ankle and foot immobilizing device and measuring its efficacy at improving image fusion. Methods: We enrolled 20 patients undergoing distal lower-limb SPECT/CT of the ankle and the foot with and without a foot holder. The misalignment between SPECT and CT images was computed by manually measuring 14 fiducial markers chosen among anatomical landmarks also visible on bone scintigraphy. Analysis of variance was performed for statistical analysis. Results: The obtained absolute average difference without and with support was 5.1±5.2 mm (mean±SD) and 3.1±2.7 mm, respectively, which is significant (p<0.001). Conclusion: The introduction of the foot holder significantly decreases misalignment between SPECT and CT images, which may have clinical influence in the precise localization of foot and ankle pathology.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e Computadores
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia de Eletrónica e Computadores
Resumo:
Experimental optoelectronic characterization of a p-i'(a-SiC:H)-n/pi(a-Si:H)-n heterostructure with low conductivity doped layers shows the feasibility of tailoring channel bandwidth and wavelength by optical bias through back and front side illumination. Front background enhances light-to-dark sensitivity of the long and medium wavelength range, and strongly quenches the others. Back violet background enhances the magnitude in short wavelength range and reduces the others. Experiments have three distinct programmed time slots: control, hibernation and data. Throughout the control time slot steady light wavelengths illuminate either or both sides of the device, followed by the hibernation without any background illumination. The third time slot allows a programmable sequence of different wavelengths with an impulse frequency of 6000Hz to shine upon the sensor. Results show that the control time slot illumination has an influence on the data time slot which is used as a volatile memory with the set, reset logical functions. © IFIP International Federation for Information Processing 2015.
Resumo:
Dissertation presented to obtain the PhD degree in Electrical and Computer Engineering - Electronics
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
The amorphous silicon photo-sensor studied in this thesis, is a double pin structure (p(a-SiC:H)-i’(a-SiC:H)-n(a-SiC:H)-p(a-SiC:H)-i(a-Si:H)-n(a-Si:H)) sandwiched between two transparent contacts deposited over transparent glass thus with the possibility of illumination on both sides, responding to wave-lengths from the ultra-violet, visible to the near infrared range. The frontal il-lumination surface, glass side, is used for light signal inputs. Both surfaces are used for optical bias, which changes the dynamic characteristics of the photo-sensor resulting in different outputs for the same input. Experimental studies were made with the photo-sensor to evaluate its applicability in multiplexing and demultiplexing several data communication channels. The digital light sig-nal was defined to implement simple logical operations like the NOT, AND, OR, and complex like the XOR, MAJ, full-adder and memory effect. A pro-grammable pattern emission system was built and also those for the validation and recovery of the obtained signals. This photo-sensor has applications in op-tical communications with several wavelengths, as a wavelength detector and to execute directly logical operations over digital light input signals.
Resumo:
Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.
Resumo:
Aortic access problems due to diseased or small peripheral vessels are a major issue in endovascular aneurysm repair (EVAR). In the emergency setting, like aortic rupture after blunt trauma, or in patients with a hostile abdomen, a more proximal access to the aorta is not a pleasant perspective. We developed in situ introducer sheath dilatation as a bail-out technique for patients with difficult aortic access under various circumstances including EVAR, intra-aortic balloon pump insertion and cannulation for perfusion. The method described allows to increase the access vessel diameter by 50% (from 6 to 9 mm) or the luminal circumference from 18 to 27 F. We have used this technique in five patients without complication, very much in contrast to the traditionally practiced 'forced device insertion'.
Resumo:
Actualment un típic embedded system (ex. telèfon mòbil) requereix alta qualitat per portar a terme tasques com codificar/descodificar a temps real; han de consumir poc energia per funcionar hores o dies utilitzant bateries lleugeres; han de ser el suficientment flexibles per integrar múltiples aplicacions i estàndards en un sol aparell; han de ser dissenyats i verificats en un període de temps curt tot i l’augment de la complexitat. Els dissenyadors lluiten contra aquestes adversitats, que demanen noves innovacions en arquitectures i metodologies de disseny. Coarse-grained reconfigurable architectures (CGRAs) estan emergent com a candidats potencials per superar totes aquestes dificultats. Diferents tipus d’arquitectures han estat presentades en els últims anys. L’alta granularitat redueix molt el retard, l’àrea, el consum i el temps de configuració comparant amb les FPGAs. D’altra banda, en comparació amb els tradicionals processadors coarse-grained programables, els alts recursos computacionals els permet d’assolir un alt nivell de paral•lelisme i eficiència. No obstant, els CGRAs existents no estant sent aplicats principalment per les grans dificultats en la programació per arquitectures complexes. ADRES és una nova CGRA dissenyada per I’Interuniversity Micro-Electronics Center (IMEC). Combina un processador very-long instruction word (VLIW) i un coarse-grained array per tenir dues opcions diferents en un mateix dispositiu físic. Entre els seus avantatges destaquen l’alta qualitat, poca redundància en les comunicacions i la facilitat de programació. Finalment ADRES és un patró enlloc d’una arquitectura concreta. Amb l’ajuda del compilador DRESC (Dynamically Reconfigurable Embedded System Compile), és possible trobar millors arquitectures o arquitectures específiques segons l’aplicació. Aquest treball presenta la implementació d’un codificador MPEG-4 per l’ADRES. Mostra l’evolució del codi per obtenir una bona implementació per una arquitectura donada. També es presenten les característiques principals d’ADRES i el seu compilador (DRESC). Els objectius són de reduir al màxim el nombre de cicles (temps) per implementar el codificador de MPEG-4 i veure les diferents dificultats de treballar en l’entorn ADRES. Els resultats mostren que els cícles es redueixen en un 67% comparant el codi inicial i final en el mode VLIW i un 84% comparant el codi inicial en VLIW i el final en mode CGA.
Resumo:
Background: Complex wounds pose a major challenge in reconstructive and trauma surgery. Several approaches to increase the healing process have been proposed in the last decades. In this study we study the mechanism of action of the Vacuum Assisted Closure device in diabetic wounds. Methods: Full-thickness wounds were excised in diabetic mice and treated with the VAC device or its isolated components: an occlusive dressing (OD) alone, subathmospheric pressure at 125 mm Hg (Suction), and a polyurethane foam without (Foam) and with (Foamc) downward compression of approximately 125 mm Hg. The last goups were treated with either the complete VAC device (VAC) or with a silicne interface that alows fluid removel (Mepithel-VAC). The effects of the treatment modes on the wound surface were quantified by a two-dimensional immunohistochemical staging system based on vasculature, as defined by blood vessel density (CD31) and cell proliferation (defined by ki67 positivity), 7 days post wounding. Finite element modelling was used to predict wound surface deformation under dressing modes and cross sections of in situ fixed tissues were used to measure actual microstrain. Results: The foam-wound interface of the Vacuum Assisted Closure device causes significant wound stains (60%) causing a deformation of the single cell level leading to a profound upregulation of cell proliferation (4-fold) and angiogenisis (2.2-fold) compared to OD treated wounds. Polyurethane foam exposure itself causes a frather unspecific angiogenic response (Foamc, 2 - fold, Foam, 2.2 - fold) without changes of the cell proliferation rate of the wound bed. Suction alone without a specific interface does not have an effect on meassured parameters, showing similar results to untreated wounds. A perforated silicone interface caused a significant lower microdeforamtion of the wound bed correlating to changes of the wound tissues. Conclusion: The Vacuum Assisted Closure device induce significanttissue growth in diabetic wounds. The wound foam interface under suction causes profound macrodeformation that stimulates tissue growth by angiogenesis and cell proliferation. It needs to be taken in consideration that in the clinical setting different wound types may profit from different elements of this suction device.