930 resultados para Chemistry Techniques, Analytical


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Publisher varies: 1961-68, Interscience Publishers; 1971- Wiley-Interscience and Wiley (an Interscience publication).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Latest issue consulted: T. 42, vyp. 12 (dek. 1987).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Translation of Zhurnal analiticheskoĭ khimii.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Contains "A bibliography of analytical chemistry... 1886-92," by H.C. Bolton.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An analysis of thermal degradation products evolved during the melt processing of organo-layered silicates (OLS) was carried out via the use of a solid phase microextraction (SPME) technique. Two commerical OLSs and one produced in-house were prepared for comparision. The solid phase microextraction technique proved to be a very effective technique for investigating the degradation of the OLS at a specific processing temperature. The results showed that most available OLSs will degrade under typical conditions required for the melt processing of many polymers, including thermoplastic polyurethanes. It is suggested that these degradation products may lead to changes in the structure and properties of the final polymer, particularly in thermoplastic polyurethanes, which seem significantly succeptable to the presence of these products. It is also suggested that many commercially available OLSs are produced in such a way that results in an excess of unbound organic modifier, giving rise to a greater quantity of degradation products. All OLSs where compared and characterised by TGA and GC-MS. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Microtome sections of proton exchange membrane cells produce a wide range of information ranging from macroscopic distribution of components through specimens in which the detailed distribution of catalyst particles can be observed. Using modern data management practices it is possible to combine information at different scales and correlate processing and performance data. Analytical electron microscopy reveals the compositional variations across used cells at the electrolyte/electrode interface. In particular analytical techniques indicate that sulphur concentrations are likely to diminish at the interface Nafion/anode interface. © 2006 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: The use of PHMB as a disinfectant in contact lens multipurpose solutions has been at the centre of much debate in recent times, particularly in relation to the issue of solution induced corneal staining. Clinical studies have been carried out which suggest different effects with individual contact lens materials used in combination with specific PHMB containing care regimes. There does not appear to be, however, a reliable analytical technique that would detect and quantify with any degree of accuracy the specific levels of PHMB that are taken up and released from individual solutions by the various contact lens materials. Methods: PHMB is a mixture of positively charged polymer units of varying molecular weight that has maximum absorbance wavelength of 236 nm. On the basis of these properties a range of assays including capillary electrophoresis, HPLC, a nickelnioxime colorimetric technique, mass spectrophotometry, UV spectroscopy and ion chromatography were assessed paying particular attention to each of their constraints and detection levels. Particular interest was focused on the relative advantage of contactless conductivity compared to UV and mass spectrometry detection in capillary electrophoresis (CE). This study provides an overview of the comparative performance of these techniques. Results: The UV absorbance of PHMB solutions, ranging from 0.0625 to 50 ppm was measured at 236 nm. Within this range the calibration curve appears to be linear however, absorption values below 1 ppm (0.0001%) were extremely difficult to reproduce. The concentration of PHMB in solutions is in the range of 0.0002–0.00005% and our investigations suggest that levels of PHMB below 0.0001% (levels encountered in uptake and release studies) can not be accurately estimated, in particular when analysing complex lens care solutions which can contain competitively absorbing, and thus interfering, species in the solution. The use of separative methodologies, such as CE using UV detection alone is similarly limited. Alternative techniques including contactless conductivity detection offer greater discrimination in complex solutions together with the opportunity for dual channel detection. Preliminary results achieved by TraceDec1 contactless conductivity detection, (Gain 150%, Offset 150) in conjunction with the Agilent capillary electrophoresis system using a bare fused silica capillary (extended light path, 50 mid, total length 64.5 cm, effective length 56 cm) and a cationic buffer at pH 3.2, exhibit great potential with reproducible PHMB split peaks. Conclusions: PHMB-based solutions are commonly associated with the potential to invoke corneal staining in combination with certain contact lens materials. However this terminology ‘PHMBbased solution’ is used primarily because PHMB itself has yet to be adequately implicated as the causative agent of the staining and compromised corneal cell integrity. The lack of well characterised adequately sensitive assays, coupled with the range of additional components that characterise individual care solutions pose a major barrier to the investigation of PHMB interactions in the lenswearing eye.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A thorough investigation of the recommended colorimetric method for the determination of malathion (an organophosphorus pesticide) has led to the identification of the major cause of all the problems with which the method suffers. The method, which involves the extraction of the copper (II) complex or the hydrolysis product of malathion from aqueous solution into immiscible organic solvents, has many drawbacks. For example, the colour of the organic extract fades very quickly and a slight increase in the contact time of the hydrolysis product and the copper reagent within the aqueous solution, results in a decrease in the ab-solute absorbance. Also, the presence of any reducing agents can be a significant source of error. In the present work, it has been shown that the basic cause of all these problems is the ability of copper (II) ion to be reduced to copper (I) ion. It has further been shown that these problems can be resolved by re-placing copper (II) by bismuth (III). This has led to the development of a modified colorimetric method for the determination. of malathion, which has distinct advantages over all other existing methods in terms of reagents required, ease in application, avoidance of interferences and stability of colour for extended periods of time. The modified colorimetric method described above has been further improved by making use of a ligand exchange reaction involving dithizone. The resulting final organic extract in this case is bright orange in colour, the absorbance of which can be measured even with simple photometers. The usefulness of the modified colorimetric method has been demonstrated by determining malathion in technical products, and in aqueous solution containing the compound down to sub ppm levels. The scope and applicability of atomic absorption spectrophotometry has been extended by demonstrating for the first time that the technique can be used for the indirect determination of malathion. Almost all of the work described above has been accepted for publication by international journals and considerable interest in the work has been shown by chemists working in the field of pesticide analysis and research.