943 resultados para CT images subject-specific design
Resumo:
PURPOSE To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. MATERIALS AND METHODS Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. RESULTS Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. CONCLUSION AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.
Resumo:
OBJECTIVE To compare the accuracy of radiography and computed tomography (CT) in predicting implant position in relation to the vertebral canal in the cervical and thoracolumbar vertebral column. STUDY DESIGN In vitro imaging and anatomic study. ANIMALS Medium-sized canine cadaver vertebral columns (n=12). METHODS Steinmann pins were inserted into cervical and thoracolumbar vertebrae based on established landmarks but without predetermination of vertebral canal violation. Radiographs and CT images were obtained and evaluated by 6 individuals. A random subset of pins was evaluated for ability to distinguish left from right pins on radiographs. The ability to correctly identify vertebral canal penetration for all pins was assessed both on radiographs and CT. Spines were then anatomically prepared and visual examination of pin penetration into the canal served as the gold standard. RESULTS Left/right accuracy was 93.1%. Overall sensitivity of radiographs and CT to detect vertebral canal penetration by an implant were significantly different and estimated as 50.7% and 93.4%, respectively (P<.0001). Sensitivity was significantly higher for complete versus partial penetration and for radiologists compared with nonradiologists for both imaging modalities. Overall specificity of radiographs and CT to detect vertebral canal penetration was 82.9% and 86.4%, respectively (P=.049). CONCLUSIONS CT was superior to radiographic assessment and is the recommended imaging modality to assess penetration into the vertebral canal. CLINICAL RELEVANCE CT is significantly more accurate in identifying vertebral canal violation by Steinmann pins and should be performed postoperatively to assess implant position.
Resumo:
The investigator conducted an action-oriented investigation of pregnancy and birth among the women of Mesa los Hornos, an urban squatter slum in Mexico City. Three aims guided the project: (1) To obtain information for improving prenatal and maternity service utilization; (2) To examine the utility of rapid ethnographic and epidemiologic assessment methodologies; (3) To cultivate community involvement in health development.^ Viewing service utilization as a culturally-bound decision, the study included a qualitative phase to explore women's cognition of pregnancy and birth, their perceived needs during pregnancy, and their criteria of service acceptability. A probability-based community survey delineated parameters of service utilization and pregnancy health events, and probed reasons for decisions to use medical services, lay midwives, or other sources of prenatal and labor and delivery assistance. Qualitative survey of service providers at relevant clinics, hospitals, and practices contributed information on service availability and access, and on coordination among private, social security, and public assistance health service sectors. The ethnographic approach to exploring the rationale for use or non-use of services provided a necessary complement to conventional barrier-based assessment, to inform planning of culturally appropriate interventions.^ Information collection and interpretation was conducted under the aegis of an advisory committee of community residents and service agency representatives; the residents' committee formulated recommendations for action based on findings, and forwarded the mandate to governmental social and urban development offices. Recommendations were designed to inform and develop community participation in health care decision-making.^ Rapid research methods are powerful tools for achieving community-based empowerment toward investigation and resolution of local health problems. But while ethnography works well in synergy with quantitative assessment approaches to strengthen the validity and richness of short-term field work, the author strongly urges caution in application of Rapid Ethnographic Assessments. An ethnographic sensibility is essential to the research enterprise for the development of an active and cooperative community base, the design and use of quantitative instruments, the appropriate use of qualitative techniques, and the interpretation of culturally-oriented information. However, prescribed and standardized Rapid Ethnographic Assessment techniques are counter-productive if used as research short-cuts before locale- and subject-specific cultural understanding is achieved. ^
Resumo:
Radiomics is the high-throughput extraction and analysis of quantitative image features. For non-small cell lung cancer (NSCLC) patients, radiomics can be applied to standard of care computed tomography (CT) images to improve tumor diagnosis, staging, and response assessment. The first objective of this work was to show that CT image features extracted from pre-treatment NSCLC tumors could be used to predict tumor shrinkage in response to therapy. This is important since tumor shrinkage is an important cancer treatment endpoint that is correlated with probability of disease progression and overall survival. Accurate prediction of tumor shrinkage could also lead to individually customized treatment plans. To accomplish this objective, 64 stage NSCLC patients with similar treatments were all imaged using the same CT scanner and protocol. Quantitative image features were extracted and principal component regression with simulated annealing subset selection was used to predict shrinkage. Cross validation and permutation tests were used to validate the results. The optimal model gave a strong correlation between the observed and predicted shrinkages with . The second objective of this work was to identify sets of NSCLC CT image features that are reproducible, non-redundant, and informative across multiple machines. Feature sets with these qualities are needed for NSCLC radiomics models to be robust to machine variation and spurious correlation. To accomplish this objective, test-retest CT image pairs were obtained from 56 NSCLC patients imaged on three CT machines from two institutions. For each machine, quantitative image features with concordance correlation coefficient values greater than 0.90 were considered reproducible. Multi-machine reproducible feature sets were created by taking the intersection of individual machine reproducible feature sets. Redundant features were removed through hierarchical clustering. The findings showed that image feature reproducibility and redundancy depended on both the CT machine and the CT image type (average cine 4D-CT imaging vs. end-exhale cine 4D-CT imaging vs. helical inspiratory breath-hold 3D CT). For each image type, a set of cross-machine reproducible, non-redundant, and informative image features was identified. Compared to end-exhale 4D-CT and breath-hold 3D-CT, average 4D-CT derived image features showed superior multi-machine reproducibility and are the best candidates for clinical correlation.
Resumo:
Purpose: Accurate delineation of the rectum is of high importance in off-line adaptive radiation therapy since it is a major dose-limiting organ in prostate cancer radiotherapy. The intensity-based deformable image registration (DIR) methods cannot create a correct spatial transformation if there is no correspondence between the template and the target images. The variation of rectal filling, gas, or feces, creates a noncorrespondence in image intensities that becomes a great obstacle for intensity-based DIR. Methods: In this study the authors have designed and implemented a semiautomatic method to create a rectum mask in pelvic computed tomography (CT) images. The method, that includes a DIR based on the demons algorithm, has been tested in 13 prostate cancer cases, each comprising of two CT scans, for a total of 26 CT scans. Results: The use of the manual segmentation in the planning image and the proposed rectum mask method (RMM) method in the daily image leads to an improvement in the DIR performance in pelvic CT images, obtaining a mean value of overlap volume index = 0.89, close to the values obtained using the manual segmentations in both images. Conclusions: The application of the RMM method in the daily image and the manual segmentations in the planning image during prostate cancer treatments increases the performance of the registration in presence of rectal fillings, obtaining very good agreement with a physician's manual contours.
Resumo:
Purpose: Accurate delineation of the rectum is of high importance in off-line adaptive radiation therapy since it is a major dose-limiting organ in prostate cancer radiotherapy. The intensity-based deformable image registration (DIR) methods cannot create a correct spatial transformation if there is no correspondence between the template and the target images. The variation of rectal filling, gas, or feces, creates a noncorrespondence in image intensities that becomes a great obstacle for intensity-based DIR. Methods: In this study the authors have designed and implemented a semiautomatic method to create a rectum mask in pelvic computed tomography (CT) images. The method, that includes a DIR based on the demons algorithm, has been tested in 13 prostate cancer cases, each comprising of two CT scans, for a total of 26 CT scans. Results: The use of the manual segmentation in the planning image and the proposed rectum mask method (RMM) method in the daily image leads to an improvement in the DIR performance in pelvic CT images, obtaining a mean value of overlap volume index = 0.89, close to the values obtained using the manual segmentations in both images. Conclusions: The application of the RMM method in the daily image and the manual segmentations in the planning image during prostate cancer treatments increases the performance of the registration in presence of rectal fillings, obtaining very good agreement with a physician's manual contours.
Resumo:
The satellite remote sensing missions are essential for long-term research around the condition of the earth resources and environment. On the other hand, in recent years the application of microsatellites is of interest in many space programs for their less cost and response time. In microsatellite remote sensing missions there are tight interrelations between different requirements such as orbital altitude, revisit time, mission life and spatial resolution. Also, all of these requirements can affect the whole system level design characteristics. In this work, the remote sensing microsatellite sizing process is divided into three major design disciplines; a) orbit design, b) payload sizing and c) bus sizing. Finally, some specific design cases are investigated inside the design space for evaluating the effect of different design variables on the satellite total mass. Considering the results of the work, it is concluded that applying a systematic approach at the initial design phase of such projects provides a good insight to the not clearly seen interactions inside their highly extended design space
Resumo:
Desde hace tiempo ha habido mucho interés en la automatización de todo tipo de tareas en las que la intervención humana es esencial para que sean completadas con éxito. Esto es de especial interés si además se ciertas tareas que pueden ser perfectamente reproducibles y, o bien requieren mucha formación, o bien consumen mucho tiempo. Este proyecto está dirigido a la búsqueda de métodos para automatizar la anotación de imágenes médicas. En concreto, se centra en el apartado de delimitación de las regiones de interés (ROIs) en imágenes de tipo PET siendo éstas usadas con frecuencia junto con las imágenes de tipo CT en el campo de oncología para delinear volúmenes afectados por cáncer. Se pretende con esto ayudar a los hospitales a organizar y estructurar las imágenes de sus pacientes y relacionarlas con las notas clínicas. Esto es lo que llamaremos el proceso de anotación de imágenes y la integración con la anotación de notas clínicas respectivamente. En este documento nos vamos a centrar en describir cuáles eran los objetivos iniciales, los pasos dados para su consecución y las dificultades encontradas durante el proceso. De todas las técnicas existentes en la literatura, se han elegido 4 técnicas de segmentación, 2 de ellas probadas en pacientes reales y las otras 2 probadas solo en phantoms según la literatura. En nuestro caso, las pruebas, se han realizado en imágenes PET de 6 pacientes reales diagnosticados de cáncer. Los resultados han sido analizados y presentados. ---ABSTRACT---For a long period of time, there has been an increasing interest in automation of tasks where human intervention is needed in order to succeed. This interest is even greater if those tasks must be solved by qualifed specialists in the area and the task is reproducible or if the task is too time consuming. The main objective of this project is to find methods which can help to automate medical image annotation processes. In our specific case, we are willing to delineate regions of interest (ROIs) in PET images which are frequently used simultaneaously ith CT images in oncology to determine those volumes that are afected by cancer. With this process we want to help hospitals organize and have from their patient studies and to relate these images to the corpus annotations. We may call this the image annotation process and the integration with the corpus annotation respectively. In this document we are going to concentrate in the description of the initial objectives, the steps we had to go through and the di�culties we had to face during this process. From all existing techniques in the literature, 4 segmentation techniques have been chosen, 2 of them were tested in real patients and the other 2 were tested using phantoms according to the literature. In our case, the tests have been done using PET images from 6 real patients diagnosed with cancer. The results have been analyzed and presented.
Resumo:
Support for molecular biology researchers has been limited to traditional library resources and services in most academic health sciences libraries. The University of Washington Health Sciences Libraries have been providing specialized services to this user community since 1995. The library recruited a Ph.D. biologist to assess the molecular biological information needs of researchers and design strategies to enhance library resources and services. A survey of laboratory research groups identified areas of greatest need and led to the development of a three-pronged program: consultation, education, and resource development. Outcomes of this program include bioinformatics consultation services, library-based and graduate level courses, networking of sequence analysis tools, and a biological research Web site. Bioinformatics clients are drawn from diverse departments and include clinical researchers in need of tools that are not readily available outside of basic sciences laboratories. Evaluation and usage statistics indicate that researchers, regardless of departmental affiliation or position, require support to access molecular biology and genetics resources. Centralizing such services in the library is a natural synergy of interests and enhances the provision of traditional library resources. Successful implementation of a library-based bioinformatics program requires both subject-specific and library and information technology expertise.
Resumo:
A presença da Medicina Nuclear como modalidade de obtenção de imagens médicas é um dos principais procedimentos utilizados hoje nos centros de saúde, tendo como grande vantagem a capacidade de analisar o comportamento metabólico do paciente, traduzindo-se em diagnósticos precoces. Entretanto, sabe-se que a quantificação em Medicina Nuclear é dificultada por diversos fatores, entre os quais estão a correção de atenuação, espalhamento, algoritmos de reconstrução e modelos assumidos. Neste contexto, o principal objetivo deste projeto foi melhorar a acurácia e a precisão na análise de imagens de PET/CT via processos realísticos e bem controlados. Para esse fim, foi proposta a elaboração de uma estrutura modular, a qual está composta por um conjunto de passos consecutivamente interligados começando com a simulação de phantoms antropomórficos 3D para posteriormente gerar as projeções realísticas PET/CT usando a plataforma GATE (com simulação de Monte Carlo), em seguida é aplicada uma etapa de reconstrução de imagens 3D, na sequência as imagens são filtradas (por meio do filtro de Anscombe/Wiener para a redução de ruído Poisson caraterístico deste tipo de imagens) e, segmentadas (baseados na teoria Fuzzy Connectedness). Uma vez definida a região de interesse (ROI) foram produzidas as Curvas de Atividade de Entrada e Resultante requeridas no processo de análise da dinâmica de compartimentos com o qual foi obtida a quantificação do metabolismo do órgão ou estrutura de estudo. Finalmente, de uma maneira semelhante imagens PET/CT reais fornecidas pelo Instituto do Coração (InCor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP) foram analisadas. Portanto, concluiu-se que a etapa de filtragem tridimensional usando o filtro Anscombe/Wiener foi relevante e de alto impacto no processo de quantificação metabólica e em outras etapas importantes do projeto em geral.
Resumo:
Produtos com um tempo considerável de utilização podem ser objeto de um processo de manutenção mais amplo e profundo, que visa prolongar a sua vida útil. O termo recuperação é aplicado a este tipo de manutenção, que visa à substituição de peças defeituosas, desgastadas, e/ou com a vida útil encerrada. O surgimento de novos paradigmas e de um novo conjunto de doutrinas operacionais pode mudar as expectativas e necessidades das partes interessadas de modo que o produto pode ser proposto para uma modernização. Assim, o produto pode ser reengenheirado durante a sua recuperação. Para realizar um projeto de recuperação e modernização, propõe-se uma abordagem em seis passos centrada numa decisão baseada no risco para classificar os componentes de acordo com a ação a ser realizada. A análise do produto é desenvolvida com base em técnicas de desmontagem e uma análise da fase operacional é realizada para as tomadas de decisões. Deste modo, um componente pode sofrer manutenção, ser modernizado, ser excluído, ser inserido ou permanecer fora do escopo dos trabalhos. O processo da gestão baseada em risco também inclui duas fases de monitoramento de risco continuado: durante a produção e na fase de operação. As decisões podem ser revistas pelo uso da análise bayesiana. Um estudo de caso é proposto para ilustrar o modelo num programa de recuperação e modernização de veículos blindados realizada numa unidade do Exército Brasileiro. A aplicação da metodologia permitiu a seleção de uma alternativa de modernização, considerando riscos e benefícios. O desdobramento das análises no projeto detalhado permitiu a definição final do escopo de recuperação e modernização, observando efeitos de propagação de alterações de engenharia. A principal contribuição deste trabalho é a formalização de um estudo da recuperação e modernização como projeto específico, descrevendo suas características de uma forma a permitir a aplicação de um modelo baseado em risco.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
Study Design. Survey of intraobserver and interobserver measurement variability. Objective. To assess the use of reformatted computerized tomography (CT) images for manual measurement of coronal Cobb angles in idiopathic scoliosis. Summary of Background Data. Cobb angle measurements in idiopathic scoliosis are traditionally made from standing radiographs, whereas CT is often used for assessment of vertebral rotation. Correlating Cobb angles from standing radiographs with vertebral rotations from supine CT is problematic because the geometry of the spine changes significantly from standing to supine positions, and 2 different imaging methods are involved. Methods. We assessed the use of reformatted thoracolumbar CT images for Cobb angle measurement. Preoperative CT of 12 patients with idiopathic scoliosis were used to generate reformatted coronal images. Five observers measured coronal Cobb angles on 3 occasions from each of the images. Intraobserver and interobserver variability associated with Cobb measurement from reformatted CT scans was assessed and compared with previous studies of measurement variability using plain radiographs. Results. For major curves, 95% confidence intervals for intraobserver and interobserver variability were +/- 6.6 degrees and +/- 7.7 degrees, respectively. For minor curves, the intervals were +/- 7.5 degrees and +/- 8.2 degrees, respectively. Intraobserver and interobserver technical error of measurement was 2.4 degrees and 2.7 degrees, with reliability coefficients of 88% and 84%, respectively. There was no correlation between measurement variability and curve severity. Conclusions. Reformatted CT images may be used for manual measurement of coronal Cobb angles in idiopathic scoliosis with similar variability to manual measurement of plain radiographs.
Resumo:
This paper describes a methodology: 'decision rules for analyzing manufacturing activities', which is designed to be a practical system of enquiry linking a strategic analysis to the design of production systems. The paper describes the development of the system, an industry specific design methodology, into DRAMA II which is a model that serves as an analytical tool for studying decision processes and implementation of production systems.
Resumo:
Mock circulation loops are used to evaluate the performance of cardiac assist devices prior to animal and clinical testing. A compressible, translucent silicone ventricle chamber that mimics the exact size, shape and motion of a failing heart is desired to assist in flow visualization studies around inflow cannulae during VAD support. The aim of this study was therefore to design and construct a naturally shaped flexible left ventricle and evaluate its performance in a mock circulation loop. The ventricle shape was constructed by the use of CT images taken from a patient experiencing cardiomyopathic heart failure and used to create a 3D image and subsequent mould to produce a silicone ventricle. Different cardiac conditions were successfully simulated to validate the ventricle performance, including rest, left heart failure and VAD support.